Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
t T i ,i Business & Professional Regulation OW Home i Log In f User ftistratton i Hot Topics i Submit Surcharge ( Stats&Facts ( Publications i Contact us ( aciS Site WAP; Lints ( Search 3 xProduct Approval p Q USPublic User Product Appn"j Menu>Product or Aooltcatlon Search>Aooncatlon Wt>Application Detall FL# FL1654-R22 Application Type Revision RECEIVES i Code Version 2017 I Application Status Approved OCT tf Comments Archived ❑ ST. Lucie County, Permitting Product Manufacturer POLYGLASS USA Address/Phone/Emall 1111 W.Newport Center Drive Deerfield Beach,FL 33442 7 (954)233-1330 Ext 242 malpert@polyglass.com t Authorized Signature Maury Alpert malpert@p Ygless-com REVIEWED F O CODE Technical Representative Maury Alpert CODE C O M P L IA N d E Address/Phone/Emall 1111 W.Newport Center DdvaC%''�` /'A Deerfield Beach,FL 33442 %7/ ■ L U C i E V®Q U E ry,dr (912)429-8610 ®II 1$ MAipeit@patygiass.trom BOC C Quality Assurance Representative Ariel Lender I�44JJ Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (954)233-1230 ALender@polygtass.com s Fe Com: Category Roofing h�t Subcategory Modified Bitumen Roof System t/ GI. Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W.Kne2evlch,PE © Validation Checklist-Hardcopy Received Certificate of independence FL1654 R2.2 COI 2017 01 COI Nleminen.odE i Referenced Standard and Year(of Standard) Standard rear ASTM D6262 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM 06222 2011 ASTM D6509 2009 FM 4470 2012 FM 4474 2011 UL 1897 2012 I I 1 j 1 i Ii I Equivalence of Product standards Certified By Sections from the Code Product Approval Method Method i Option D Date Submitted 09/14/2017 Date Validated 09/15/2017 Date Pending FBC Approval 09/22/2017 Date Approved 12/12/2017 Date Revised 10/06/2018 Summarv,of Products FL# Model,Number or Name Description 1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems Bitumen Roof Systems Limits of Use Installation Instructions Approved for use In IIVHZ:No F'L1654 R22 U 2017 09 FINAL Ai ER POLYGLASS MODBiT FLI654- Approved for use outside HVHZ:Yes 822.odf Impact Resistant:N/A Verified By:Robert Nleminen PE-59166 Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes Other:1.)The design pressure in this application Evaluation Reports relates to one particular assembly over concrete FL1654 654 R 2 AE 2017 09 FINAL ER POLYGLASS MODQ BIT FL 1654- deck.Refer to the ER Appendix for other systems R22,od and deck types 2.)Refer to ER,Section 5 for other Created by Independent Third Party:Yes Limits of Use. seek RQ Contact Us::2601 Blair Stand peed.Tallahassee FL 32399 Phone:SSd«187-•!924 i The state of Fw wo is an AMM employer,Copyright 2007-2912 State of Flarfda.'1:0lvaev Statement::AcatisIbIlIty Statement::Refund Statement Under fla tda law,dmad addresses ore public records.it you do riot want your a-mall address ral"Wil In response to a Public records request,do not send electronic mail to this entity,instead,contact the office by phone or by troditionai MAIL if you have any questions,via=contact 850.487.1395.-Pursuant to Seaton 455.275(1), Florida Statutes,effective October 1,2012,licences licensed under Chapter 455,F.S.mat provide the Department with an small address It they have one,The emAus provided may be used for*facial communication whh the licensee.However email addresses ore public record.If you do mat wish to supply a personal address,please pmvWe the Department with an emall address which ion be made available to the public To determine if you are a licensee under Chapter 455,F.S.,please dirk ham,, i t product Approval Rccapta: Credit Card Safe I I I , r� ,JTRINITY ERD - - -- TABLE IF-2 W000DECKS NEY4i CONSTRUCTION;REROOF(TEAR OFF)aR REcolr4t SYSTEMTYPEE NON-INSULATED,MEGHANICALLYATTA;CHEQBASESHfeET(SCREWS&PLATFs',BONDEDROOFCOVER System Dedc(Note 1) Base Sheet Roof Cover(Note i5) MOP No. Type Fasten Attach Base Ply Cep (Psf) SELF-AOHEIIING BAEPLYt. - W-136 Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast H14 12-Inch o.c.in 4-Inch lap and 12-Inch ox-In two SBS-SA SBS-SA,APP-SA,SBS- -5250 Inch plywood (poly-film top) orTrufast 3"Metal Insulation Plate WthTrufast HD (2),equally spaced,staggered center rows TA,APP-TA W-237 Min.19/32- Elastobase,Elastobase P Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14 12-Inch o.c.in 4-Inch lap and 124nch o.c.in two Polyfiex SA Base APP TA -52.50 Inch plywood (poly-film top) erTrufast 3"Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows W-138 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrip#12 12-Inch o.c.in 4-inch lap and 12-Inch o.c.In two SRS-SA SBS-SA,APP-SA,SBS- -60.0• Inch plywood (poly-film top) (2),equally spaced,staggered center rows TA,APP-TA W-139 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrlp 812 124nch o.c.in 44nch lap and 12-Inch o.c.In two PolyfiexSA Base APP TA -60.04 Inch plywood (poly-film tap) (2),equally spaced,staggered center rows .._. .•, . ...,•,_,. ..:, • . ;. � •.. • TABLE iG:WOOA DECKS=NEW��ON57RUCTiON on REROOF(Ttt�a-aFF) ': . SYSfERh`FYPEF NQN-INSULg7ED,BOND�DROOFCOV System Deck(Note 1) Primer Roof Cover(Note 35) MDP(Psf) No. lointTreatment Base Ply Pty tap Pty W-140 Min.15/32- None None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -90.0 Inch plywood TA,APPTA TA,APP-TA W-141 Mia.IS/32 (optional)1,6100 None PolyflexSABase (Optlonal)APP-TA APP-TA -90.0 Inch plywood W-142 Min.15/32- PG200 None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS 97.5 Inch plywood TA,APPTA TA,APP-TA Min.15/32- Plywood)oims are covered with 44nch wide strips of ElastcflexSA V Plus,rolled Into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- -97.5 W-143 inch plywood (Optional)PG300 place to create continuous bond. Elestofiex SA V FR Base TA,APP-TA TA,APP-TA W-144 I MIn.15/32- WB-3000 None SBS-SA (Optional) SBS-SA,APP-SA,SBS- -105.0 Inch plywood I TA,APP-TA Min.15132- Plywood Joints are covered with 44nch wide strips of ElastoflexSA V Plus,rolled into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- 5BS-SA,APP-SA,SBS- -135.0 W-145 inch plywood (Optional)PG100 place to create continuous bond. ElastoRex SA V Plus FR TA,APP-TA TA,APP TA Min.15/32- Plywood Joints are covered with 4-Inch wide strips of ElastoflexSA V Plus,rolled into Polyflex SA Base (Optional)APP-TA APP TA -135.0 W-146 inch plywood (Optional)PG100 place to create continuous band. Exterior Research and Design,U.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-11120 for FL3654-R22 Certificate of Authorization N9503 19"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/12/2017 Prepared by:Robert Nleminen,PE-59166 Polyglass Modified Bitumen Roof Systems,(570)384-1230 Appendix 1,Page 22 of 58 J TRINITY i ERD -- - APL?EHDIX 15ATTAOHME.Ni REQUIREMENTS FOR WIND UPLIFT RESISTANCE ' `'' ' Table Deck Application Type Description Page 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 IB-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5-9 18-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 10-11 1C Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 11 ID Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 12-13 1E Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 14-15 1F-1 Wood New or Reroof(Tear-Off) E Non-Insulated Mech.Attached Base Sheet(nails),Banded Roof Cover 16-18 IF-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 19-21 16 Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 21 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 22-24 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 25-28 20- Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 29-31 3A Structural concrete Now or Reroof(Tear-Off) A-1 Banded Insulation,Bonded Roof Cover 32-40 3B Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 40 4A LWIC New or Reroof(fear-Oft) A-1 Banded Insulation,Banded Roof Cover 4142 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 43 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 4446 SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 47 5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 48 5C CWF New,Reroof(Tear-Oft)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 49 51) CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 49 SE CWF New,Reroof(Tear-Oft)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 49 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 50-52 613 Gypsum Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 52 6C Gypsum Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 53 613 Gypsum Reroof(Tear-Off)or Recover E Non-Insulated Mech.Attached Base Sheet,Bonded_Roof Cover 53 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 54-58 78 Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 58 The followine notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shag be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: D Wood: Minimum 0.75-Inch penetration. Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. D Structural concrete: Minimum i-Inch embedment Into pilot hole in accordance with fastener manufacturer's published Installation instructions. 3. Unless otherwise noted,Insulation may be any one layer or combination of polylsocyanurate,polystyrene,wood fiberboard,perlite,gypsum-based roof board or mineral-wool roof board that meets the CIA requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. Exterior Research and Design,U.C.d/b/a Trinity ERD Evaluation Report P9290.02.08-1120 for FU654-RZZ Certificate of Authorization 89503 6Tx EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20,.09/12/2017 Prepared by: Robert Nleminen,PE-59166 Polyglass Modified Bitumen Roof Systems;(570)384-1230 Appendix 1,Page 1 of 5B ` TRINITY j ERS 15. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. TAB�EI..POLYGIASS.iIOOF GONERS., Reference Layer Material Application BP-AA Base Ply One or more plies Polyglass G2 Base FBC Approved ASTM D4601,Type II Hot Asphalt at 20-40 (Base and Ply sheets,Asphalt- Ply One or more plies Polyglass Ply IV,Polyglass PI VI,FBC Approved ASTM D2178,Type IV or VI lbs/square Applied) Note: Asphalt-opplied sheets or Insulation shall not be qpp4d to poly-film surfaced membranes. Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 Type iI,Polyglass HT Base 650 PG350 at 1.5-2.0 SBS-CAI Cap Plygal/square /q Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type 11,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshleld I s uare resTS-G FR,Pot ko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 Type 11 Polyplus 35 at 1.5-2.0 SBS-CA2 Cap Ply Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type II,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield gal/square TS-G FR,Polyfresko,G SBS(sand-backed),Polyfresko G SBS FR sand-backed) Base Ply or Ply One or more plies Elastobase(sand/sand or poly/sand),Elastobase P.(sand/sand or poly/sand),Elastoflex V,Elastoflex S6,Elastoflex SBS AA S6 Type 11,Polyglass HT Base 650 Hot Asphalt at 20.40 (SBS,Asphalt-Applied) Cap Ply Elastoflex V,Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex 56 Type II,Elastoflex S6 G,Elastoflex 56 G FR,Elastoshield TS-G, lbs/square Elastoshleld TS-G FR,Polyfresko G SBS sand-backed),Polyfresko G SBS FR(sand-backed) Note: As halt lied sheets or Insulation shall not be applied too fi m surfaced membranes. Base Ply or Ply rt or more plies Elastobase(sand/poly),Elastobase(poly/poly),Elastoflex V,Elastoflex S6,Elastoflex S6 Type 11,Polyglass HT Base SBS-TA (SRS,Torch-Applied) Elastoflex V,ElastoflexVG,Elastoflex VG FR,ElastoflexS6,ElastoflexS6 Type 11,ElastoflexS6 G.ElastoflexS6 G FR,Elastoshield TS-G, Torch-Apptled CaP Ply Elastoishield TS-G FR,Polyfresko G SBS(poly-film backed),Polyfresko G SBS FR(poly-film backed) Base Ply One or more piles Elastaflex SA V Base,Elastoflex SA V FR Base,Elastoflex SA V Plus,Elastoflex SA V Plus FR SBS-SA Cap Ply Elastoflex SA P,Elastoflex SA P FR,Pol reflect Self-Adhering (SBS,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates for SBS-SA are limited to the SBS-SA Rase Ply options herein, Elostobase(poly/samt)orElostabase (poly/poly), PG350 at M-2.0 APP-CA1 Cap Ply PolyflexG FR gal/square APP-TA Base PI or Ply One or more plies Polyglass APP Base,Polyflex,Polybond Torch-Apptled (APP,Torch-Applied) Cap Ply PoIlLflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR APP-SA Cap Ply Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool (APP,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates for APP-SA are limited to the SBS-SA Base Ply options herein, Self-Adhering Efastobase of sand or Elostoboseof ly. 16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. P6200 Non Flbered Roof Coating; D PG300 Fibered Roof Coating; PG600 Non-Fibered Aluminum Roof Coating; Y PG650 Fibered Aluminum RoofCoating; Y PG700 High Quality Elastomerlc Roof Coating or KM Acryl25; Y P6700QS(Quick Set)High Quality Elastomeric Roof Coating or KM Acryl 25-QS(for granule-surfaced APP or SOS Only); PG800 Asphalt Emulsion Roof Coating; 9 Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; D Polyplus 65 Premium Fibered Aluminum Roof Coating; D Polybrite 70 Premum Grade Elaslomeric Roof Coating or KM Acryl 15; D Polyhrite 713QS(Quick Set)Premium Grade Elastomedc Roof Coating or KM Acryl 15-QS(for granule-surfaced APP or SOS anly); D Polybrite 90 High Solids Siiicone Roof Coating or Polybrite 95 SU[cone Roof Coating. Exterlor Research and Design,LIC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-R20 for FU654-R22 Certificate of Authorization#9503 hie EDITION(2017)FBC NON-HVHZ EVALUATION Revision 20:09/12/2017 Prepared by:Robert Nieminen,PE-59166 Polyglass Modified Bitumen Roof Systems,(570)384-1230 Appendix 1,Page 3 of 58