HomeMy WebLinkAboutProduct Approval E
_67 Ly
REVIEWED i.
MIAMI•DADE CODE COMPLf�<-,,, NIIAtrII-DARE COUNTY
TPRODUCT
26sreo8aU IE COUN9l SwtetRm 20
DEPARTMENT OF REGULATORY AND ECONO + CCES(RER) (( l Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISIO v 6T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE O RECEIVED www•miamidade.gov/econom
.Tames Hardie Building Product,Inc. OCT 3 0 - 0119
10901 Elm Avenue �,�� CopyFontana,CA.92337 ST. Lucie County, Permuting
,SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perforin in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Reveal®Finer Cement Siding Panels
APPROVAL DOCUMENT: Drawing No.REVEAL NOA,titled"Reveal®Panel Installation", sheets 1
thru 3 of 3, dated 07/21/2017 and 07/17/2017,prepared by James Hardie Building Product,Inc., signed and
sealed by R.1. Ogawa,P.E.,bearing the Miami-Dade County Product Control approval stamp with the Notice
of Acceptance number and approval date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING:Large and Small Missile Impact Resistant
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city, state,
model/series and following statements: "ASTM C1186,Type A compliant"and"Miami-Dade County
Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TER'VIINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of
any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NTOA is displayed,then
it shall be done in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of this page 1 and evidence page E-1, as well as approval document mentioned above.
The submitted documentation was reviewed by Carlos M.Utrera,P.E.
ria r�s•r�a of cflurvry NOA No. 17-0406.07
Expiration Date:December 7,2022
1�/2 J7 Approval Date:December 7,2017
( Page 1
i 1
4�
James Hardie Building Products,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No.REVEAL NOA,titled"Reveal®Panel Installation",sheets 1 thru 3 of 3,dated
07/21/2017 and 07/17/2017,prepared by James Hardie Building Product,Inc., signed and
sealed by R. I. Ogawa,P.E.
B. TESTS
1. Test reports on 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94
2)Cyclic Wind Pressure Loading per FBC,TAS 203-94
along with marked-up drawings and installation diagram of James Hardie Building Products,
Inc. Artisan Bevel Channel Fiber Cement Siding, prepared by Intertek, Test Report No.
102761825COQ-005, dated 12/19/2016,with revision dated 08/16/2017, signed and sealed by
Gary T. Hartman,P.E.
2. Test report on Standard Specification for Discrete Non-Asbestos Fiber-Cement interior
Substrate Sheets per ASTM C1288-99 and Standard Specification for Flat Fiber-Cement
Sheets per ASTM C1 186-08 of HardieReveal2.Um Panels,prepared by Intertek,Test Report
No. 101505709COQ-002, dated 07/30/2014, signed by Chris Chang.
3. Test report on Surface Burning Characteristics per ASTM E84-13a of Hardie Revea12.0xM
Panels,prepared by Intertek,Test Report No. 101505709COQ-003, dated 06/20/2014, signed
and sealed by Greg Philp.
4. Test report on Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at
750°C of James Hardie Building Products Artisan D4 Siding,per ASTM E136-04,prepared
by Ramtech Laboratories,Test Report No.3733.16-04(B),dated 05/18/2016,signed by
Steven Berggren.
C. CALCULATIONS
1. Anchoring verification calculations prepared by R.I.Ogawa&Associates,Inc.,dated
07/29/2017, signed and sealed by R. I. Ogawa,P.E.
D. QUALITY ASSURANCE.
I. Miami-Dade Department of Regulatory and Economic Resources(RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 5'Edition (2014)and 6th Edition(2017)FBC
issued by R.I. Ogawa&Associates,Inc, dated 07/29/2017,signed and sealed by R.1. Ogawa,
P.E.
2. Statement letter of no financial interest issued by R.I. Ogawa&Associates,Inc,dated
07/29/2017,signed and sealed by R.I. Ogawa,P.E.
All Z'71VII
Carlos M. Utrera,P.E.
Product Control Examiner
NOA No.17-0406.07
Expiration Date:December 7,2022
Approval Date:December 7,2017
E-1
PRODUCT DESCRIPTION REVEAL PANEL INSTALLATION DETAILS
Reveal®Panel Siding materials are non-abestos fiber Gement panel products
comply with ASTM C1186 Grade Il,Type A and meet the requirements of 0 All Installation shall be done In conformance with this Notice of Acceptance,
Florida Building Code. the manufacturers's installation recommendations,and the applicable
sections of the Florida Building Code.
PRODUCT DIMENSIONS • Wood or steel frames where RevealO Panel will be installed shall be
Width:4 ft.;Length:8 ft.;Thlokness:%e In. designed by an Engineer or Architect per the Florida building Code and the
PANEL FASTENINGCONFIGURATION 41{Design Pressure= .70 psf) requirement of this N.0 A.
• #8 bugle head screws by 1.625"long by 0.390"head diameter • INote 11 b/"thick 5-ply APA rated plywood sheathing shall be attached to
+ • Countersunk installation with fastener head to be 1-1.5 mm below the panel the wood framing members In accordance with Florida Building Code
] surface, Section 2322.3.
j • Installed at 12"O.C.to furring,which is 16"O.C. • [Note 211x4 SAF wood furring at 16"spacing and attached to wood
s
I framing members by#10 x 2-1/4"screws at 6"o.c_Alternative fastening
} PANEL FASTENING CONFIGURATION#2(Design Pressure= .103 psf) schedule or furring material be designed by an Engineer or Architect per the
( • #10-12 button head screws by 1.5"long by 0.472"head diameter requirement of Florida Building Code,
I • installed with exposed head at 12"O.C.to furring;which is 16"O.C. . [Note 31 Choices of two fasteners attached to furring at 12"x 16"o.c,In
i IMPACT RESISTANT accordance with Configurations#1 and#2.
jPanel Installed over s/"thick 5-play APA rated plywood sheathing supported by • Fasteners shall have a minimum edge distance of 3/"and a minimum
1 2x wood studs or 2x618ga.metal studs.at 16"o.c, clearance of 2"from comers,
• The provisions for diaphragm action and 9j?v yk> je not part of this
WALL FRAMING approval(must be provide alternativ p otN ).
• Nominal 2x4 SPF(S,G.=0.42)wood studs or 2x618 ga.(Grade 33)metal tit �`. . �.�e�t,Ads
`+
studs at 16"O.C. _ " '
• The wall frame shall be designed by the architect or engineer of record in
compliance with the Florida Building Code. PRODUCT APPROVED
as complying with the Florida2�
Building Code w
S14EATHING NOA-No. 17-0406.07
• Nominal W thick 5-ply APA rated plywood sheathing fastened to wood Approval Dat 12/07/20'C 7 5T 0 ;�•r�,
framing members In accordance with Florida Building Code Section 2322.3.
FURRING Miami- Product BY ... .....
• Nominal 1x4 wood furring spaced vertically at 16'o,c,Wood furring shall be
preservative treated per AWPA.
• Wood furring shall be attached to framing members by#10 screw at 6"o.c, Created by Checked by Approved by-date, Filename Date Scaie
For wood framing,use screws with minimum length of 2-1/4",For steel Pingsheng Zhu "lf 21,20117
framing,screws must penetrate the steel members by at least 3 threads. ---- —
• Alternative fastening schedule or furring material shall be designed by the James Hardie Building Products Reveal®Panel Installation
architect or engineer of record in compliance with the Florida Building Code. 10901 elm Avenue,rantana,CA!92337 DWG No, Rev Sheet
REVEAL NC)A-1 1 1 of 3
`l •
r+—^B
Wali frame,2x
® ® #C SPF wood stud
or 2x6 1 s ga.
metal stud at 16"
•"'% 5' n.C,
i3
Water resistiver.s
?z barrier per FBC
sf
Section 1404,2
6-ply plywoo
kx sheathing[Notes) PRODUCT APPROVED
a m ® ® x
as complying with the Florida,
F Building Code
r`rY: NOMNo, 17-0406.07
Approval Date 12107/2017
7z By
96 �'
MiaMPDre Produ&t Control
Ian
x4 SPF woad
furring spaced at 16 es Detail A
X
�! o.c.attached to
t framing members
S Wth#1b x 2-1/4" 10 f1001/sr,,o4�A
® y a © p ® screws ata"o.c, iipi``•OGAVV'q
3 fit' ••.
12fYP or#10screws 1�®®p.G. •.
fastened to furring d
l ' at 12'5X16"ac. ! 1+
jConttgutatfons#1
and#2] ti
I 16"Typr b
fj e+rea10 Panel � �.�
{`} B 96 L� siding B-13 ����remrre��i3�0p
Created by Checked by Approved by.-date Filename Date state
r Pingsheng Zhu I I July 47,2017
1 James Hardie Building Products Reveals Panel Installation
10901 Ehn Avenue,Fontana,CA 92337 DWG No, REVEAL NOA-2 Rev Sheet
Water resistive barderCountersunk or-exposed
per FBC Section 1404.2 screw attached to furring
[Configuratictrls#1 
Ix.
IA
I ,/X.
IZf jI
Ir M
'i. PRODUCT APPROVED
5-ply APA rated pi ood_'.' I Reved Panel as Igin
Code with the Florida
/X e
sheathing attached frame X' Building17-0406.07
per Florida Build' g Code NOA-No.
_21.1yXI
[Note 1]
Approval Dae '12107120'17
>
conro
/4" Mia am,- a ro U roU
I
Wood furring a shed to
framing members wi h#10 x 'X
X Y
2-1/4"screws 6"O.C.
X,
Oil
OGA
Drainage Ai .. ........
flashing or trim
STNVF- OF
Wall frame:2x4
SPF wood stud or
x4 SPF Wood
2x6 18 ga. metal
stud at 16"oc. Detail A Furring[Note 21
Creatadtry Checked by Approvedby-data Eftename Date Scale
Pingsheng Zhu July 77,2017
James Hardie Building Products Reveal®Panel installation
10901 Elm Avenue,Fontana,CA 923371Rav Sheat
OWGND' REVEALN4A-3
CV
U
w
o �
J
M
r�
?13