Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Buidling Permit
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 10/31/2019 Permit Number: COUNT- F L n a-., Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Building Permit Application Commercial Residential X PERMIT TYPE: Electrical PROPOSED IMPROVEMENT LOCATION: Address: 192 Nettles BLVD Property Tax ID #: 4502-501-0378-000-1 Site Plan Name: Bergevin Project Name: Bergevin DETAILED DESCRIPTION OF WORK: — Hooked up water heater to two existing dedicated circuits. CONSTRUCTION INFORMATION: Additional work to be performed under this permit –check all that apply: _,Mechanical _ Gas Tank _ Cas Piping — Shutters C?- Electric —Plumbing —Sprinklers Total Sq. Ft of Construction: Cost of Construction: $ 700.85 — Generator Sq. Ft. of First Floor: Lot No. Block No. Windows/Doors Roof Pitch Utilities: — Sewer _ Septic Building Height: OWNER/LESSEE; Name Elizabeth Bergevin Address: 192 Nettles Blvd City:. Jensen Beach State: C ii Zip Code: 34957 Fax: Phone No. 518-569-5606 E -Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) CONTRACTOR: Name:John Pankraz Company: Elite Electric and Air Address:1691 SW S Macedo Blvd City: Port Saint Lucie State: FL _ Zip Code: 34984 Fax: 772-340-3702 Phone No 772-340-3797 E -Mail permit@eliteelectricandair.com State or County License CAC1 816433 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW fNFQRMATIO DESIGNER/ENGINFt`t�. N. Name: - - r IMUI Applicable Address: City - Zip: phone State: FEE SIMPLE TITLE HOLDER: Name:Not Applicable Address: City:— Zip: Phone: MORTGAGE COMPANY: 111 Name:at Applicable Address: City: Zip: —�� Phone: State: BONDING COMPANY: Name: Not Applicable Address: City. — Zip: �� Phone: OWNER/ CONTRACTOR AFFiDViT: Application is hereby made to obtain a permit to do the work and install i certify that no work or installation has commenced prior to the issuance of a permit. 5t. Lucie Coun p anon as indicated. makes an representation Ho that is granting a Permit will authorize the permit holder to build the subject structure which is in con lict with any applicable Nome Owners Association rules, bylaws or and covenants that may restrict or structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of #his requested permit, I do hereby agree that I will, in all respects, perform the yy, prohibit such in accordance with thea y approved plans, the Florida Building Codes and St. Lucie County Amendments. work The following building permit applications are exempt from undergoing a full concurrency review: room additions accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TU TWICE FOR RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN IMPROYEMEIIiTg TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. iF YOU INTEND TO OBTAIN FiNANC NGUR PAYING WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE Of_COMIItVNrr"CWu n CONSULT l� j signature o r/Lessee/Contractor as Agant fnr Owner STATE OF FLORIDA COUNTY OF Sr' LU Et r The forgoing instrument was acknowledged before me this %I day of try 2D ids- by Name of person making statement. Personally KnownX1 OR Produced Identification Type of Identification Produced - _ _ _ W ,,; KOWLENAE'DEWITT ?, ye = Notary Public — State of Florida • 'Commission # GG 166915 y� " :'.My Comm. Expires Dec 10, 2021 of Notary Commission No. } w L� Cj l {Seal} REVIEWS FRONT ZONING DATE COUNTER REVIEW RECEIVED DATE COMPLETFn Signature of Bolder STATE OF FLORIDA COUNTY OF The forgoing instrument was acknowledged before me this :31 day of 4�G{UL,F r 20 ! c1 by Name of person making statement. Personally Known _ X OR Produced Identification Type of Identification Produced �+v:'�`Fi1JANNILENAEDEWIFT Notary Public — State o1 Rorida Commission # GG 166915 My Camm. ExpiresDec 10, 2021 [signature of Notary pu Commission No. (Seal) :REVIEW ERVISOR PLANS VEGETATION REVIEW SEA TURTLE MANGROVE REVIEW REVIEW REVIEW fv, A G �, -Z, C, 6z� Sup len �Juqw B�,A J-P-OA.IA Guw, � � 00 Tr ` I 0 0 IJ .lob (2448x3264) TI— V/ https://go-servicetitan-com/Attach/job?name=Attaches%2F76569630-7cd-1-4de5-8fO7-fced3d35aaal_cdv—photo-001-bt!)yy2u72we.]'Pg 1I2 Elite Electric & Air, Inc. Load Calculations Phone #: Email address: Customer Name: ,� Location : Existing Service Feeder Size: J 10 Existing Panel Size: Main Breaker Size: oD 6M Number of Breakers: xistingy Loads _1281' Sq. Ft. X 3 watts per sq. ft . . ........... • • Q 1 watts 9 Minimum 2 Appliance cir. @1500 watts each...... woo watts Laundry cir. @ 1500 watts each ...................... i� watts —'Range @ S kw.......... ....................................... watts Dishwasher and disposal @ 1500 watts each ...... 3 )tDu watts Wall mounted Microwave @ 2000 watts........,. 00 watts Water heater @ 4.5 kw ................................ watts Dryer @ 5 kw ............... . ................ o watts Extra refrigerator @1500 watts..... ...... I I ......... I C00 watts Sprinkler Pump ........................................ watts ---L—Other 1aoOL)Q&S kA/ctil- 1-6v '........ watts 4 Other &�� "S b o ti r r1,� , ...... I watts Other ........... New i.nadc watts Subtotal $ 2 I 'Watts Pool pump............ ... watts Pool light ................... watts Heat pump ................. watts Chlorine generator ................... watts Air blower ........................ ............... watts Boatiift ............... watts Other ................ wads Other ............ watts Other ................ watts 4"'0( First 10 kw @ 100% ................................ .. .... ..... r©� ou watts Total Watts. �_ l 1 Remainder @ 40% ....................— p� _._S q 0 watts 101 .A/C @100% vs. heat @ 65% ........................ .. watts Total watts 1a,104 -'4o Divided by 240 volts = 1 —Amps P Prepared by; ��' Date: eo /30/)0-, HomeAdvantage ti"M For Single Point -of --Use or Muftiple Applications Applications • Water -Saver Shower Head 1.5 GPM • Standard Shower Head 2.0 GPM • Standard Hand Sink 0.5 GPM • Kitchen Sink • Bath Tub 1 to 2 GAM • Dishwasher —> 4 GPM • Washing Machine 1 to 2 GPM A19y90 rxufons 1 �r �firnrt� iGPhC. UasaQ rrt 2f310 rium6irtu S�1ard; 1 to 1.5 GPM Performance Features • Instant, consistent and endless hot water • Compact, resistant and stylish with digital temperature control in increments of 1' ranging from 807 to 140°F • Copper immersion heating elements with brass top increases durability and are threaded for easy replacement • Simple Installation • Digital temperature display • External controls to adjust temperature Special Design Service Inquiries for units for unique applications are welcome. Cali our Technical Service department at 1-800-543-6163. Suggested Specification Tankless water heater shall be an Eemax HomeAdvantago 11 model number HA Unit shall have copper clad immersion heating element{s) with brass terminations for increased durability. External temperature control and display adjustable in I' increments with a range Of 80°-140T Display shall be capable of displaying setpoint temperature in Celsius or Fahrenheit temperature scales. Unit shall utilize a flow meter with a 0.3 GPM activation point and manage Power based on actual flow rate and inlet temperature. Values should be processed 60 times per second. Unit shall be WQq certified lead tree, certified to UL499 and CSA -022.2 No. 64. Eemax Inline Flow Regulator PART NUMBER EEMA,X GPM N CF INSERTS PRCADEO CONNEC710N SIZE IFR 1-2 3.0, i ,5, 2.0 112" NPT HAO08240/HA01124(VHA013240 specifications Flectric Tankiess Water Heater aw HApi M HAO36240 Oaktedsn4c'-s PM-- 'In5"d nY 6rav 011ainsL—,s. lnSertek P25", k:d lint rr i :}iF:ArL- „ Eemax Inline Flow Regulator Suggested Sizing Guide- Inlet Water Temperature NA008240 IFR 1-2 1.0 1.0 HA011240 iFR 1-2 10 1.0 1.5 lFR 3-4 2,0.3-0,4.0,5.0 3/4° NPT HA413241) IFR 1-2 1.0 1.5 HAO18240 IFR 3-4 2.0 2.0 2.0 3.o • Enhanced outlet temperature control HAO24249 IFR 3-4 2.0 • Install on the outlet side of the heater 2.0 30 4•p tlAa2�24a IFR �-4 2.0 a.a 4.0 5.0 • Limit maximum volume to the specified flow, rate to ensure HAO36240 IFR 3-4 3.0 4.0 exiting temperature is within an acceptable range 5 0 5.0 • Flow Regulators for Y2" and 3/4" plumbing connections 1"ra�ir"t o�ranreandan� tia:ea, 105—, Restriction range: 1.0 to 5.0 gallons per minute v' hhx�ration and PrnrJuc sl ��fi:25[ma arb fined 1 h6 3 daann""' are s:,secl to Gti7r€r vrihxg 10 e. REV 201ap? HameAdvantage 11 For Single Point -of -Use or Multiple Applications TEMPERATURE RISE °F Specifications FlecU is Tankless Water Heater MODEL NUMGE}i kW AMPS .. VWIRE SIZE {75° C/Cl!) TURN ON {GPM) MAXX FLO FLOW 0.5 1.0 i .5 1.5 2.0 2.5 3.0 4.0 5.0 6.0 . 240V units ran he V%d an 2084 MOB phase with 25% reduced r r GPM GPM Gl'M GPM GPM GPM GPM GPM temperature eulput. Please note C HA008240 8.0 33[ix40) BAWD e.3 4.8 109" 55° pet UL standards the rating Pete andinsalatloninStuctionswill311 C HA.IX18240:deralad 2084 ee p�.amar�el 5.8 28 - 6A'NG 0.3 36° 27° 22° 18° 14° - - be according to a 240V applied C BA011240 11.0 46{1x50) 8AWG q8 79° 40° 26' 20° 16° '3° l0` - _ voltage. CheckwihIn lotfr oats C HA011240,delaPedm+ti .208Vpertoricel ULO SAWG 0.5 4.8t 75' 50' 38° 30° - 251 19° - - prlDrtoda'a3a iheo g iscAical in6astnicture, C Win 13.0 54(1xCn'1) 6AWG 0.3 0.3 t,8 %,322° $ 56° 37° 28° 22° 19° 14° hzmicaYy f Temperature elecvaned C HA013240 ideraled 268V pedormaicel 10,1 49(3x60) 5 AVVG f 89° 59° 44° 30° 3Cr selling on ajrrstablgjiedi M611824018.0 0.3 4.8on T 59' 4S' 34" 28° 23' 17 - f101 Mi 750M) 8AWG 0.3 7.9 fi 7 82` fit° a9° 41° - "C"indaales eva;irfiin and C HAOlB240,awed 208Vpertarm5lcel 19.3 ri4i2x'32) SAWG 0:3 7.0 31° 26' 20 camplancelaeither Unoewdters C HA029240 24,0 100[3.r331 BAN,�G t 9-,- 61- 45° 3'S" X. 23° 16" 15° LaboraMos (W or inlenek C HAD2424D derdted208Vperarmanee) 17.5 8L(3x28) 8AWG 0.3 7.0 t1119° S2° E6° 55" 41° 33° 27' IEMLinderCA1VlCSA-C22.2No. 64fIVo.88. C HAOM40 27.0 113(3x37) SAWG D.3 0.3 7.0 $ i 8D° 60° 48° 401 30- 24' 20` C HA62724 ACreled208Vper.'ormenoei 20.0 96 (3x32 1 8l1W0 D.3 7.0 7.0 f f k 92° 74° 51' 46° 37° 31" RA036240 36.0 150(4x38) 8AWG 0.3 t 91° 6E" 55' 46° 3-=° 23° HA036240,nerelcd208Vperf0rmancel 25.6 127(4x32: BAWD 0.3 8.0 8.D j f - f f Q° 98` 82° 61' 49` 41° 1- 73° fit° 45° 35° 30° Product Specifications (ail models) Dynamic Operating Pressure: 25 PSI min„ 150 PSI max. Certifications: EfL Listed to UL 499 and CSA Adj. Temperature Range: 80'F -140°F Temperature Accuracy: /-14 at steady stake HAOGU401HAO1124011 13240 Size: 11,5°H 8"W x 3,75"D Weight: 8 kw: 4.75 lb, 11 kW/13 kw, 7 Ib Unique Features: Welded exchanger, 112" Compression fitCl'ngs wM 1/2" NPT adapters induded HAO18240 Size: 17°H x 14"W x 3.75"0 Weight: 11.25 Ib Unique Features: Welded exchanger, 3/4" NPT fitfinas 4.1 9.9 3.4 7.9 3.4 139- &0 11.4 e.0 12.2 17.0 15.1 1.5 9 1.6 li HAO24240/HAO2724d1 HA036240 Size: 17"H x 1 T'W x 3.75'D Size: 17"H x 21"'W x 3,75_"D Weight: 13.75 Ib Weight: 17,4 Ib Unique Features: Welded exchanger, 3/4" NPT ffings Unique Features: Welded exchanger, 314° NPT ftings 1.4 2.6 3.4 17.0 d�l.s 3.2 lrramtatun and eroduc4 spectral''ans emlanen in Ori documem are subject he GUe without nui REV 2019-02 Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 192 NETTLES Parcel ID: 4502-501-0378- Account #: 119966 BLVD Sec/Town/Range: 02/37Sf41E 000-1 Map ID: 45/02G Zoning: Hutch Isla Use Type: 0100 Jurisdiction: Saint Lucie County Ownership Legal Description Elizabeth A Bergevin (TR) NETTLES ISLAND INC, A CONDO -SECTION 11 PARCEL 192 192 Nettles BLVD AND PRO -RATA SHARE IN COMMON ELEMENTS Jensen Beach, FL 34957 current Values Just/Market: $177,200 Assessed: Exemptions: $50,500 Taxable: Date Book/Page 11-06-2018 4218/2841 03-29-2013 3509/0664 12-27-1996 1055/0991 View: Year Built: 2014 Primary Wall: CB Stucco Bedrooms: 3 Full Baths: 2 Half Baths: 0 Sale History Sale Code Deed Grantor 0130 WD Bergeviu Elizabeth A 0001 WD Rood Jack A XXOI WD Jack A Rood Primary Building Information Finished Area of this building: 902 SF Gross Sketched Area: 1,046 SF Roof Cover: Metal Frame: Story Height: I Story AIC %: 100% Heated %: 100% Sprinkled %: N/A% Exterior Data Roof Structure: Hip Grade: ISHH No. Units: 1 Interior Data Electric: MAXIMUM 1M Heat Type: FrcdHotAir Heat Fuel: ELEC Total Areas Price $100 $55,000 $100 Building Type: ISHI Effective Year: 2014 Secondary Wall: Primary Int Wall: Avg Hgt/Floor: 0 Primary Floors: Tile -Ceramic Finished/Under Air Historical Values 3 -year (SF): $177,200 Year Just/Market Assessed Exemptions Taxable $126,700 2019 $177,200 2018 $186,100 $177,200 $50,500 $151,734 $126,700 2017 $180,200 $0 $137,940 $0 $151,734 $137,940 Sale History Sale Code Deed Grantor 0130 WD Bergeviu Elizabeth A 0001 WD Rood Jack A XXOI WD Jack A Rood Primary Building Information Finished Area of this building: 902 SF Gross Sketched Area: 1,046 SF Roof Cover: Metal Frame: Story Height: I Story AIC %: 100% Heated %: 100% Sprinkled %: N/A% Exterior Data Roof Structure: Hip Grade: ISHH No. Units: 1 Interior Data Electric: MAXIMUM 1M Heat Type: FrcdHotAir Heat Fuel: ELEC Total Areas Price $100 $55,000 $100 Building Type: ISHI Effective Year: 2014 Secondary Wall: Primary Int Wall: Avg Hgt/Floor: 0 Primary Floors: Tile -Ceramic Finished/Under Air 902 (SF): Gross Sketched Area 1,046 (SF): Land Size (acres): 0.04 Land Size (SF): 1,587 Total Building Count: 1 Special Features and Yard Items Type Qty Units Year Blt All information is believed to be correct at flus time, but is subject to change and is provided without any warranty. 0 Copyright 2019 Saint Lucie County Property Appraiser. Ail rights reserved.