Loading...
HomeMy WebLinkAboutProduct Approval aor i ` 1 s � a Business aProfessibnatRegulation ` OR SCIS Home i Log In i User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map I Links I Search Florida En 1141 Product Approval f0.ka4zz dd M — USER:Public User &frar�P�tm Product Approval Menu>Product or Application Search>Application List>Application Hlstory>Application Detail OFFICE OF THE' FL# FL20468-R2 Application Type Revision Code Version 2017 Application Status Approved RECEIVED Comments OCT 3 ® 2Q,g Archived l— ST. Lucie County, Permitting Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton,OH 43517 (419)298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email I it Quality Assurance Representative Address/Phone/Email ^. Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer I] Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F.Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J.King, P.E. L✓l Validation Checklist-Hardcopy Received Certificate of Independence FL20468_132 COI (b)Certificate of Independence.pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2005 ASTM E1886 2005 ASTM E1886 2002 ASTM E1996 2009 ASTM E1996 2006 ASTM E1996 2002 ASTM E1996 2005 ASTM E330 2002 TAS 202 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL20468_R2_Equiv EQUIVALENCY OF STANDARDS.pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/06/2017 Date Validated 12/14/201.7 Date Pending FBC Approval 12/18/2017 Date Approved 02/13/2018 Date Revised 10/09/2018 Summary of Products FL# Model,Number or Name Description 20468.1 a.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL20468 R2 il_(dJ Inst 20468.1.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.1 for Design Pressure Ratings,any FL20468 R2 AE (c)Eval 20468.1.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.2 b.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R2 11 (d Inst 20468.2.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.2 for Design Pressure Ratings,any FL20468_R2_AE_(d)Eva]20468.2.pAf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.3 c.Therma-Tru Fiber-Classic and Nominal 68"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL20468 R2 IA (d)Inst 20468.3.pddf, Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.3 for Design Pressure Ratings,any FL20468 R2 AE_W) Eval 20468.3.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.4 d.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468R2J1_(d)Inst 20468.4.g_df Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.4 for Design Pressure Ratings,any FL20468_R2_AE_(p)Eval 20468.4.p�f additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.5 e.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R2 II_(d)Inst 20468.5.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.5 for Design Pressure Ratings,any FL20468 R2 AE (d)Eva[20468.5.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.6 f.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R2_II_(d)_In920468.6.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Parry:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.6 for Design Pressure Ratings,any FL20468_R2_AE_(d)Eva]20468.6.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.7 g.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Single Smooth-Star Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468 R2 II (d)Inst 20468.7.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.7 for Design Pressure Ratings,any FL20468_R2_AE_(d) Eva[20468.7.pdf additional use limitations,installation instructions and product Created by Independent Third Parry:Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.8 h.Therma-Tru Fiber-Classic and Nominal 68"Impact"Glazed Composite Edge Fiberglass Single Smooth-Star Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL20468_R2 II_(d)Inst 20468.8.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.8 for Design Pressure Ratings,any FL20468 R2 AE_(d)Eval 20468.8.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.9 i.Therma-Tru Fiber-Classic and Nominal 68"Impact"Glazed Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing;XX or I, OXXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL20468_62 II_(d) Inst 20468.9.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.9 for Design Pressure Ratings,any FL20468_R2 AE (d)Eval 20468.9.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.10 j.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Single Smooth-Star Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL20468_R2 11 (d) Inst 20468.10.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.10 for Design Pressure Ratings,any FL20468_R2 AE_(d)Eval 20468.10.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door panels, this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.11 k.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Single Smooth-Star Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ:No FL20468_R2II_(d)Inst 20468.11.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.11 for Design Pressure Ratings,any FL20468 R2 AE (d)Eva[20468.11.Ddf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) 20468.12 I.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL20468_R2 11 (d)Inst 20468.12.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 20468.12 for Design Pressure Ratings,any FL20468_R2 AE (d Eval 20468.12.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars.(For Fiber-Classic and Smooth-Star Door and Sidelite panels,this product approval requires the use of"J"part numbers for these doors,which have been stained or painted within six months of installation.) Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Cogyright 2007.2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address„please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: RW R W Building Consultants,Inc. BConsulting and Engineering Services for the Building Industry. C P.O.Box 230 Valdco,FL 33595 Phone 813.659.9197 Florida Board orProfmional Engineers certificate of Authorization No.9813 Pi-oduct Evahlatioll 'II l' . I / 2017 Product Category Sub Category Manufacturer Product Name Swinging Therma Tru Corporation Fiber-Classic and Smooth-Star Exterior Exterior Door 118 Industrial Drive Composite Edge Opaque Fiberglass Single Door Doors Assemblies Edgerton,OH 43517 Inswing/Outswing Phone 419.298.1740 "Impacr, Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E.for Therma Tru Corporation based on Rule Chapter No.61 G20-3,Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1.This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). 2.Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3.When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5.Site conditions that deviate from the details of drawing FL-20468.1 require further engineering analysis by a licensed engineer or registered architect. 6.Fiber-Classic&Smooth-Star Door panels require the use of"J"part numbers and must be stained or painted within six months of installation 7.See drawing FL-20468.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by ETC 01-741-10700.0 TAS 202-94 ETC Laboratories Wendell W.Haney,P.E. ETC 01-741-10702.0 TAS 202-94 ETC Laboratories Wendell W.Haney,P.E. TEL 01461612 ASTM E1886-05,E1996-09,E330-02 Testing Evaluation Leb.,lnc. V.K.Wright TEL 01460145 ASTM E1886-02,E1996-02,E330-02 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt,P.E. 2. Drawing No. Prepared by Signed&Sealed by No.FL-20468.1 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 3. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 4. Quality Assurance p�QBa@BOilg;gr�o Certificate of Management Institute,� e,certifying that Tru Corporations eeee,ion issued by National Accreditation and `eb%,-.- ............ v%C E N S'- manufacturing products within a quality assurance program that compiles with ISO/IEC 17020 and Guide 53. +* No 43409 v OF 'U�e e ......R —'* =o Lyndon F.Schmidt,P.E. SsfdA�Eye°� 12/5/2017 FL PE No.43409 Sheet 1 of 1