Loading...
HomeMy WebLinkAboutProduct Approval 9 rpJll ©Ii$'8'A��i. Before Installing... � Please take the time to read through the ENTIRE instructions prior to starting any work. 3 Ar 2' ✓�� ��` s1{� + i' o o art 1. Ensure normal safety precautions are taken >~ Caulking Gun U Screwdriver when using tools and walking on roofs. :- Marking Pencil ri, Stud Finder 2. Do not cut any structural members in the house. = Measuring Tape 1 String 3. Measure twice and cut once. = Reciprocating Saw Utility Knife L., Safety Goggles if Ladder- s - a> When determining location of the unit, try to place the solar attic fan on the south side of the..roof,-.also.cons-Wer potential problems such as objects shading the unit during certain times of the-day.. The unit should also.be centered on the roof and the center of the unit should be about 2 feet down from the roof ridge.. N MEL Note: Exploded view for illustrative purposes. Unit comes pre-assembled. "`---- C A. (2) Self-Tapping Screws B. Custom Solar Panel C. Wire Lead E D. Adjustable Solar Panel Bracket E. Aluminum Shroud F. Custom 36V DC Motor G. Motor Isolation at on Br acket Hii �o H. Air Driven Precision Pitch 5 Blade Fan H I. 3.25" x 48" Stainless Steel Wire Mesh p. (4) .09"Aluminum Shroud Support Bracket K. (6) #10 x 1.5" Stainless Steel Phillips Head Screws L. Aluminum Flashing , M. Caulk K T - .lY):yy:F�.i�7.S�y.�S.;+ 'n'1•,i Gt. Y7/ Roof rafters are generally 16" or 24" on center. On 16" on center construction, the installer can either cut a 14" hole between the rafters or cut a 19" hole with the roof rafter running through the cut hole. On 24" on center construction, cut a 19" hole between the roof rafters. Follow the steps for the opening size needed for your specific application. �°'-=" ry. �`E'� r,'•` �t4''�K'.4-'�-~�rZ7� "t,-.W,'C. '.�r�,�ez i�t"�y�7�k i, ^'' v__._.... _ .. .. �..�..- - -- - Choose location for solar attic fan,south exposure is best. If a southern exposure i .. is not feasible for your installation,the fan can be installed on any other exposure and the solar panel adjusted to capture maximum sunlight. DETERMINE SIZE OF HOLE NEEDED FOR YOUR INSTALLATION:: On 24" on center construction, center the fan between the rafters and cut a 19"hole.On On 16"on center construction,the installer can either cut a 14"hole between the rafters or cut a 19" hole with the roof rafter running through the hole (see t illustration below in step 4). I Hammer a nail at the center of the location chosen between rafters for the solar-attic fan.The center of the unit should be about 2 feet down from the ridge. _ '+" i,43�rwit«a1 'i1� � say... /•'•4 fj,x' 19" HOLE:Attach a string to the nail. Measure 9.5"of string and at- tach a marking pen to the string, see diagram. Scribe a 19" circle onto. the roof shingles. 14" HOLE: Attach a string to the nail.Measure 7"of string and attach a marking pen d +' to the string, see diagram. Scribe a 14"circle onto the roof shingles. htt 1C t'•1� t1.d � 11.t'= .,7.•: :.- I �_ ,�r With a reciprocating saw, cut the diameter of the hole. NEVER CUT THROUGH j ANY ROOF RAFTERS. LEAVE ALL FRAMING MEMBERS IN PLACE. ; IMPORTANT: The solar attic fan must be installed between the roof rafters OR over a roof rafter. DO NOT CUT THROUGH ANY FRAMING MEMBER. Only - ,7d.�S r+ka.,r�rx_•i..r r,:ti,-:i remove roof sheathing. RECOMMENDED: 51 �J HOLE CUT µi j j BETWEEN RAFTERS J! i � t OPTION: 16"ON CENTER i WITH 19"HOLE ..._X17- 1'JS•.h _._'��fi�T:�._ if�uStt 4rN_r_.,,,_,j �'2�'�b'f..H'tD it 5•+'�iu':t,'�a•.axrivr�.��T ;n ter/� 19" HOLE: With a razor knife, cut a four inch slit through the 19"HOLE shingles and tar paper at the three and nine o'clock position of the I flashing. This allows for the foot print of the flashing to be inserted under the shingles. 14" HOLE: Additional shingles may also need to be removed on the high side towards the ridge to allow the flashing to slide over the hole(see inset). 1 14" HOLE �iCJlkl7J- y „c.. . ,. 5�•�1 w'}a':1 Wj _'(I f IS Insert the reciprocating saw blade sideways at the 3:00 o'clock position and commence cutting the roofing nails up and around to the 9:00 o'clock position. This process removes the nails that will prevent the flashing footprint from sliding up underneath the shingles. "y lj 1 1 I I r �isx� y rsress�>fss m�.7iniE=•y,YS -. Caulk the underside of the flashing with the provided caulking material (M). Two concentric rings of caulking material is sufficient. ' 5 \ E'• NOTE: Installation on the roofs will require' the use of a tile skirt.To download the Tile Roof Installation, please visit: www_solaratticfan-com/customer-service/brochure-installs.html s l f -. •�T'd'2'�Y�..r'�v :!mow �R�!6?p/.. 4� "Y}. F. , - I� Taking care not to smear caulk on the exposed shingles,slide flashing under tar paper and shingles and force flashing up until the shingles come in E , contact with the raised portion of the flashing. The bottom side of the j flashing will be on top of the shingles. Secure flashing with provided (6) Phillips } j head screws (K) through the predrilled holes on the flashing footprint. ► NOTE: Local Building Code requirements may specify anchoring that requires ' 7 MMM MM additional screws installed in the flashing. For Florida and Texas installations inMMM MMMMMMs High Velocity Hurricane Zones, please refer to Natural Light's Solar Attic Fan Product Evaluation installation instructions on their websites. f ! WMWMMM j Florida Dept. of Community Affairs: FL13509; http://www.floridabuilding.org/pr/pr app_srch.as x l � MUNN Texas Dept. of Insurance: http://www.tdi.state.tx.us/wind/prod/indexrv.htmi I �MMM!! �i Caulk over the screw heads that are exposed to the weather. Useremainingcaulk to seal the areas where the 4" slits were made and around the area where the " ,_• I shingles meet with the raised area of the flashing. j if . , -,'�•'��IC •.4 .yr f1 —4 NENN�RR55R, is �c hc;:. vl' t.-°r,,;�i���1.�• a^t�- 'tom. c�'r�i Adjust the solar panel to the position it will collect the most sunlight throughout the day (the panel can be left in the down position). To adjust the solar panel, ' remove the(2)self-tapping screws on either side of the bracket. Lift up the solar panel and line up the pre-drilled hole on the bracket arm to one of the two pre-drilled holes on the "L" bracket attached to the housing. �� Re-attach the(2)self tapping screws on both sides. IMPORTANT. Prior to an anticipated hurricane or high wind event, f �'S ;'- •��:� . the solar panel must be secured with screws in the flat position. �� �,E:.>.�., �. ��,�;Q` • NOTE: Some 10 watt panels may have a clip/screw assembly. To adjust panel on these units,loosen,but do not remove, the assembly located on each side of the solar panel bracket.Adjust the solar panel to desired position and tighten screws (see inset). n�s. _� t} •o.�k,.�;k.'L,'1":,ft..PS�� %-_:'r_;r..t'j•J-Yara?:-�?3ksS+.d.t 1:4�X�}4st}7�t xi�rt!SJ.{-.:''.'#":S*Y'•��t`�4rr5r^,.�r L..�.Y'�:r�"ri+✓!t�'d�riIitvs'!ve��""'._'•{-`F":....<.FiIFr"rt'r:fr..i.^.».:.yjvf{:w*�`x�'.�'�f},r,i'-„S��Il,-'rt+";^1-"j6f.}.wcF`�;'^.'^r!'..t.;C+—5 r x ui.^iL yS`r-z,. ,,"yL.�;�:",sr�j'cy��_.s"i,e.<-°iy.`'�^.'y�J^,.`�{+�`r.t.a;"`'f.:°?{4Py)a''{y4n•?�. 4.�'FV'-+r:��'7�-'+�rS•'"e".''..f��.�..'��;.f�,.4SY52 vr . .��?l�•ti,�9��••�c`sfi•'-^s`'�•}.t-'+y, .S J. y�'•vF.?�,•*-... .a?. .. S}-�P'•�`?#' r l .'{ : >,.�� �b "- s r� v.L-t #,r�} 'S.�LVS i^'7f't�i ,�"t-L �'a•�Y'S �'� �i'`. 3+R 1� '��" r.' � �{. s,r�.;-m n}, +u-r'a 1 t g.s r .y�:+•.�,) �, • r.�v. s ca� ;.�'''="�.{�d e11=��';,t a� %rra:,, 'R}3�'�r" �t.z.=i Je—,�: a�� _ Natural Legh \'= _ I-p This Natural.dight,Solarttic Fan has a 25 year warranty j on the housing, the solar panel and the motor. IMPORTANT: PLEASE COMPLETE AND MAIL THE CARD BELOW AS SOON AS YOUR SOLAR ATTIC FAN IS INSTALLED.This card will serve as proof of your purchase, should you misplace your original invoice. - The manufacturer warrants this product to be free from defects in material and manufacturer's workmanship for a period of 25 years on the motor, the solar `4} panel and the housing,from the date of installation.This warranty is subject to proper installation of the unit in accordance with the manufacturer's written ' 4. installation instructions.The manufacturer will not be liable for any'special, incidental =� or consequential - dama es in an way related o r arising late t o a sin out of defects.ts.in e c 9 Y Y r P 9 or damage ama a to the solar attic fan. This warranty gives you specific legal rights, and you may have other rights which vary from state to state concerning exclusion or limitation of incidental or consequential damages. ' 1 Please fill but the form below and mail it to. Natural Light Energy Systems 10821 North 23rd Avenue *'Phoenix,AZ 85029 ------------ '----------------------------------------------------------------------------------------------- a Natural Light Solar Attic Fan Installer: Customer Name: Date of Purchase: Address: City: State: Zip: Phone: Email: Customer Survey Are you satisfied with the performance? Y N What made you choose our product? Were you satisfied with the installation job? Comments: � ► o • \4f ► .-,.�F� .fii,liti� d�{1�5 j.'h���ft�'�k'Yi 4N��fi t AµY Y��h +{`1�(i .+^ a�ax\ bye a �..•---'"` 5, OT s ec e . an irnp°ttant e{�}c�enth°m s, ,�A. }c venting�s e `thy enet9 Coo{e#endl og �� t ta�n�ng h the d f ma}n �eot�°J 000\00drduces ;��e�t�t��3 ; ptopet �a�V% an stern.P powered the fn . cond�t�or�h a�G}<cv\aT} 'this s\eek Jj opt a� esItes t ene g and ;-r"..`; y incteas §tee s°,a compact a\so te�y b`I s both m the c°mOe nt vent i tight{tO � d e{f}cue etat}ona� e\ecttica watt\yM- an 'Flim 0\, with n° evjvX}P 12 4v aUs eas 'l et pow {t.tvp �vp it Inst s not fotg 269 sa• p sq- • �_ jai 4 pnd het t vp to to 2,14 to ;: . .s can{v�\y v 4 w�` v�,t vp watt unit v west cCn's),a Zc�tns)and a$�{tns) ovtane�,has to A,33g � �vp tO 1'emote soar o�vp �� ,625 s4• watt t ac�tY `'� �ou5 2 with a 69 vent%ng caps cfh`s)� `, '1 �,`� on the otov n, a ch d 99 �, f' .q eaCS rd,M � n vnm t eit wp to�' , i r, .2- it. to3,25'sA /.• 0 '1 {v 5okar 1 co co Fqi 4 • • • e 12 Watt 24 Watt 36 Watt ' y � J� -- ••� 20.125'=�; - : •y 26.5" ` •22.625' 21.25" / 25.75" 60 watt remote pppCCC b® solar panel-installed separately from housing 4"• ® CURB MOUNTED SOLAR ATTIC FAN NOTE:Exploded view of Solar Attic Fan is for illustrative 23.375" purposes only. Unit comes fully assembled. ® 1. Custom Solar Panel (12, 24, 36, or 60 watt available)* 2. (2)Adjustable Solar Panel Bracket 3. (2)#8 x.75"Self-Tapping Screws 4. 18 Gauge Tinned Copper Wire Lead ° ® 5. 1100 Series, Commercial Pure Grade Aluminum Hood 6. Custom DC Motor 7. Motor Bracket Assembly 8. Precision Pitch 5 Blade Fan 12 9. 3.25"x 48"Stainless Steel Wire Mesh = 9 10. (4) Rugged 14 Gauge Hood Support Bracket . . Pp . . 11. 1100 Series, Commercial Pure Grade Aluminum Flashing • 12. (6)#6 x 1.5"Stainless SteeLPhillips Head Screws *solar'panel dimensions may vary slightly 00 _____________ OPTIONAL ACCESSORY: Thermal Snap Switch available to automatically turns off unit ® 5.75" during colder months. 3" VENTING CAPACITY 12 watts—up to 1,260 sf up to 893 CFMs ?� 22.25" 24 watts—up to 2,100 sf up to 1,339 CFMs 36 watts—up to 2,625 sf up to 1,628 CFMs 60 watts—up to 3,255 sf up to 1,995 CFMs �R!�.'� Made in USA Product Evaluation Report Rule 61G20-3 F'A.C. I Report No. ACE-2017-128 1 9/30/17 1-Page 1 of 2 Product Manufacturer: - Product Name, Model;'-Series and/or Description Natural Light Energy Systems Solar-Attic Fan 10821 N. 23rd:Ave. Powered by Photo Voltaic Panel Phoenix,AZ 85029 Code: Current Edition of the Florida Building Code including the following codes issues. :0 5th Edition(2014)Florida Building Code 61'Edition(2017)-Florida Building Code Compliance Method: 61G20-3.005(1)(d)—Product Evaluation Report by a Licensed Professional Engineer Product.Testing: a Architectural Testing Inc.Test Report No.A8071.01-301-18,dated 3/21/11,ASTM E330-02 tested,Self-Flashing. Roof Mounted Attic Ventilation Fan,Series/Model:Solar Attic Fan with 40-Watt Solar Panel for Natural Light_ Energy Systems. o Architectural Testing Inc.Test Report No.A8071.02-301-18,dated 8/24/11,TAS 202 tested,Self-Flashing Roof Mounted Attic Ventilation Fan,Series/Model:Solar Attic Fan with 40-Watt Solar Panel for Natural Light Energy Systems-Signed and sealed.by Tyler L.Westerling,P.E.,Florida PE License No.72012. o -P,.RI.Construction-Materials.Technologies Test Report No.NLES-001-02-02,dated 12/30/09,Performance Test Report;:Natural Light Systems-Solar Attic Fan for Asphalt Shingle Roofs—TAS 100(A)-95.Signed and sealed by Duc . T.Nguyen;P.E., Florida PE License.No.65034. c VRI.Construction'Materials Technologies Test Report No.NLES-002-02-02;dated'06/26/17,Performance Test Report;°Natural Light Systems—Solar Attic Fan for Corrugated Tile Roofs—TAS'1b0(A)-95.Signed and sealed by Duc T.Nguyen,P.E.,Florida PE License No.65034. Product Installation Instructions: o :Drawing No. NLES-100,dated 9/30/17,signed and sealed by Robert J.Amoruso,P.E., FL No.49752 Engineering-Analysis: The following engineering and/or rational analysis/calculations have been performed. e Anchorage has been verified by calculation prepared by RobertJ.Amoruso, P.E.in accordance with the current edition of the Florida Building Code. Performance Testing: o ASTM E330-02 o' TAS-202-94,2010 FBC o TAS 100(A)-95,2007 FBC o TAS-100(A)-95,2014/2017 FBC ',Code.Codformance.and Design Pressure Limitations: 0 R_equire-ments for roof ventilators contained in Chapter 15'of the FBC have been met.This includes- ...o ' Testing to TAS 10i1(A): o .:Safety Factor of 2 applied to Structural Test Results to arrive at final-Design.Pressure.. Miami-DadeProduct Control Division,checklists for HVHZ conformance have been reviewed and met.They include: :. o Checklist No.0463 Rooftop Mechanical Equipment(Exhaust Fans&Ventilators Robert J. Amoruso, P.E., 12472 Lake Underhill Rd., No. 148, Orlando, FL 32828 robert.amorusoCcomcast.net I FBPE FL P.E. No. 49752 Product Evaluation Report Rule 61G20-3 F.A.C. I Report No. ACE-2017-128 1 9/30/17 ( Page 2 of 2 o Checklist No.0155 Roof Ventilators,Turbines and Ridge Vents Limitations Et Conditions of Use: ;o This product has been evaluated for use inside the HVHZ(High Velocity Hurricane Zone) o This product has not been evaluated for Impact Resistance. o Refer to Product Installation Instructions noted above for: o Maximum allowable wind loads at related maximum allowable size(s). o Overall dimensions and material/grade of main product components,accessories,etc. o Illustrated diagrams of the attachment of the product to the structure. o Anchor type(s),size(s),substrate(s), embedment,edge distance,and spacing/locations. Site.wind pressures shall be determined by a licensed professional engineer in accordance with the current edition of the Florida Building Code and/or ASCE 7-10 for components and cladding based on allowable stress design. o, Site conditions not covered in this product evaluation document are subject to additional engineering analysis by a licensed•professioh6l engineer or registered architect as required by the authority having jurisdiction. o : Adequacy of the existing structural substrates as a main wind force resisting system capable of withstanding and transferring applied product loads to the foundation is the responsibility of the licensed professional engineer or registered architect acting as the design professional of record for the project.bf installation. Certificate of Independence per Product Approval Digitally Signed Rule 61 G20-3.009 ,�,oe,l"SNMES "i'". Robert J.Amoruso,P.E.does not have,nor will acquire,any ��nGE�SF'.. _,tt. by Robert J financial interest in the company manufacturing or 49752 6:`ro p A[1110@'19S0 distributing product(s)covered by this Product Evaluation Report. STAE O7 F :Q/ Date: :O: Qft Robert J.Amoruso,P.E.does not have,nor will acquire any ��'°e°�5 ��R��PC�����e 20.1 71.0,1.6 financial interest in an other entity involved in the Y Y ace000�oa0� 20:19:21 .-04'00' • .'.approval process or testing of the product(s)covered by - this Product Evaluation Report. Evaluated by: Robert J.-Amoruso, P.E. FL P.E. License No. 49752 Robert J. Amoruso, P.E., 12472 Lake Underhill Rd., No. 148, Orlando, FL 32828 robert.amorusoCcomcast.net FBPE FL P.E. No. 49752 _ Equivalency Evaluation Report Rule 61G20-3 F.A.C. I Report No. ACE-2017-128 1 9/30117 1 Page 1 of 2 Product Manufacturer Product Name, Model,Series and/or Description Natural Light Energy Systems 5o|er/N±icFan 1OQ�1N. Z3 �Ave. Powered _'P dbvPhoto VokeicPanel Phoenix,AZ85U29 | Code: Current Edition of the Florida Building Code including the following codes issues. " SmEdition(2D14)Florida Building Code " 6th Edition(217) Florida Building Code Compliance Method: Product Approval Rule 61G20-3.015(4)(d)-Equivalency of Standards Product Testing: * Architectural Testing Inc.Test Report No.AOU71.DI-3D1-18,dated 3/ZI/I1,ASTM E33O-U2tested,Self-Flashing Roof Mounted Attic Ventilation Fan,6edes/N1ode|:Solar Attic Fan with 4O-WattSolar Panel for Natural Light Energy Systems. 0 Architectural Testing Inc.Test Report No.A8071.02-301-18,dated 8/24/11,TAS Z0Ztested,Self-Flashing Roof Mounted Attic Ventilation Fan,Series/Model:Solar Attic Fan with 40-Watt Solar Panel for Natural Light Energy | Systems.Signed and sealed by Tyler L.Westerling, P.E.,Florida PE License No.72012. � w PRI Construction Materials Technologies Test Report No. NLES-001-02-02,dated 12/30/09, Performance Test Report;Natural Light Systems-Solar Attic Fan for Asphalt Shihgle Roofs-TAS 100(A)-95.Signed and sealed by Duc TNguyen, P.E,Florida PELicense No.65D34. " PRI Construction Materials Technologies Test Report No.mLES-002'Oz-oz,dated 0G/Zh/17,Performance Test Report;Natural Light Systems-Solar Attic Fan for Corrugated Tile Roofs-TAS 100(A)-95.Signed and sealed by Duc'[Nguyen, P.E,.FbridaPELicense No.65034. Performance Testing: " ASTM E330-02 ^ TAS 1VUA)-85,IUU7FB[ " TAS ZO2-94,2D1DFgC ' * lAS-100(A)-95,2014/2017F8C Equivalency Evaluation: * Testing tuTAS 282'94,ZOlUF8Cand TAS 1OO(A)'95 2OU7FBC&2014/2U17FBChave been reviewed against the requirements inTAS 202-94,ZD14FBC&IOI7F8Cand TAS 1DO(A)-95,2U14FBCand 2O17FBCand found that no changes exist that would have necessitated re-testing of the product.Therefore,the current testing is in conformance. - ° ASTM E33D'O2islisted inthe 2O14FBCand ZU27FBC. »n»««v Digitally signed by Roberti Certificate of Independence per Product Approval ^^� "" ~^ ~ ~ � Rule 61G2O 0U9 3 ' ' morUSo Robert J.Amuruuo, P.E.does not have,nor will acquire,any Date: �nanda|interestinthecompanymanufactuhngor �'��� dischbubngpnoduc�s>covered bythis Product�a|va�on '�/�17r1 16 Report Robert Amo,uso P.E.does nor' ' ' ' ' -w*=' ����^� x�^Kl�� -����'����' acquire any Mnonda|intere�inany other enthyinvo�edin / ' ��~^^ " - ^~~= = " "= the approval process urtesting ofthe pro6uct(s)covered - Evaluated by: bythis Product Evaluation Report. Robert J. Arnoruso' P.E' | FLP'E' License No. 49752 Robert J. Anooruso, P.E', 12472 Lake Underhill Rd', No. 148, Or(ando, FL 32828 robert,annorVso@}corncast'net I F8PEFLP'E. No. 49752 zNc�§ ,�,t r i apt <;� KY - J .5. i"t X A"�S E.���e"�.�`ls dJ I p P�''1+�•.� Q� s ..cry.'N __.._ BCIS Home j Log In i User Registration Hot Topics i Submit Surcharge Stats&Facts Publications ? FBC Staff iY BCIS Site Map Links Search i0!iG? Product Approval gg uuu p K �" SYO1t USHR:Public User .. Product Aoorovai Menu>Product or Anpfication Searcts>AAn riicallon List>Application Retail FL# FL13509-R5 Application Type Revision Code Version 2017 Application Status Approved Comments Archived — Product Manufacturer NATURAL LIGHT ENERGY SYSTEMS Address/Phone/Email 10821 N.23rd Ave. PHOENIX,AZ 85029 (602)485-5984 kelly@nitubular.com Authorized Signature Kelly Soya keliy@nitubular.com Technical Representative Gregg Vincent Address/Phone/Email 10821 N.23rd Ave. Phoenix,AZ 85029 (602)485-5984 gvincent@nitubular.com Quality Assurance Representative Mark Orszulak Address/Phone/Email 10821 N.23rd.Ave. Phoenix,AZ 85029 (602)485-5984 Mark@nitubular.com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert].Amoruso,P.E. the Evaluation Report Florida License PE-49752 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Steven M.Urich,PE '2. Validation Checklist-Hardcopy Received Certificate of Independence FL13509 R5 COI PER ACE-2017-12$ RevO NLES-RoafVent sdf Referenced Standard and Year(of Standard) Standard Year ASTM E330 2002 TAS 100A 1995 TAS 202• 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect X13509 RS Eauiv ESR ACE-2017-I2$ R v0 P?L 5_I2ooNen}__Ys, Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/16/2017 Date Validated 10/19/2017 Date Pending FBC Approval 10/25/2017 Date Approved 12/12/2017 Summary of Products _ FL# Model,Number or Name Description 13509.1 SOLAR ATTIC FAN SOLAR ATTIC FAN POWERED BY PHOTO VOLTAIC PANELS Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL13SO9 RS II NLES-100 RevO SolarAtticFan ss.i d! Approved for use outside HVHZ:Yes Verified By: Robert 1.Amoruso,PE FL PE No.49752 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+86.5/-175 Evaluation Reports Other: FL13509 R5 AE PER ACE-2017-128 R2V0 NLES- Rool'Vent ss.Ddf Created by Independent Third Party:Yes Sack Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The entails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: rM z�MOR icr:.c Credit Card Safe REW90RS NATURAL SLIGHT ENERGY SYSTEMS SOLA�AT7T.CFAN-POHER .D J YPHO TO VOL-TAICP NEL MsTAL.Aaa®NANCHO 4GE RETAaS GENERAL NOTES: * TIE PRODUCTANCHORACE SHOWN HEREIN ISnMOPED To COMPLYVRHWe CURREMEDOION OF THEFLORICA BUILDING AND RESMENRAL. INSTALLATION NOTES: CODESIICLUDINO THE HIGH V£LOC/TY HURAICPNE2DNE DMIZ)AT THE DESIGNPRESSURESSTATEDHUMPR t.ONE it)MSTALUOFDfl AHCHORISREOUO3EDATEACNANCNORLOCAiiDNSNOWN. L TNEPRODUCTOETApSCOMAMEDNER¢INAREB"MtYPOPISIGNEDANDSMLW"FOLLOWS: 1N 21. AT17FSTREPORTHO.ATITESTFt P RTA807t.01401-1O,DATCD03MI111,ASTMp30d2iE.5TED. 1E NUMBER OFINSFALIATOtiY NIWCNORS DEPICTED OF tOANCNORS)AR£THE MINIM"NUMBER OF ANQIORS up USED FOR 2.11. SAFETYFACTORCF2APPUMMSRNICTURALTESTRESULWYWWSDE31pt PNES3URE Of•86'•U473 FSF PRODUCfINETALLATIONASFOLLOWS: M. ATI TESTREPORTNO.ATI TEST REP00.i Afl0TL02J01•f0.DAlE0 OHQYti.TA5202dNTF.STED. 21, 2UTWUoO FRWLHO OPTION 2.2t. SAFETY FACTOR OF 2 APPUED TO STRUCFURALTESTRESULIS YIELDS DESIGN PRESSURROF•OESI-46M - 2.1.1. AMONMUMOFTEH Rtl)ANCNORG SHALL HE USED. 22. PM CONSTRUCTIptt MATERVUST,J:NNOtQGT'FEET REPORT Nt,ESdDSO2d2,GATED f2J3G99,115-100(A}93TESSEOUSSNGSN1HGiED R00F 2J. pSHAHD PLYWOOD R00F5HE+TNDtOOSR10N.TNEGREATEROF COVEFDNG. 2.2t. AtJRUMUMOFTEN(taj ANCHORS SHALLBEUSED,OR 2.1.1. TIIEPRODUCTHASTESTWFORWMDdRNENRAIli RE51STANCEPERTAS•1001A)45,SECRDN10,3AIIDFOUNOTOOEWCONFORNANCEVM 2L2- AS REQUIRED NYTHE WSTALLATOH ANCNOASCHEOVLE ON SHEETS CHAPTER 1S OF THE FBG SUBSEQUENT STRV W URAL T ESTIN G FOR INCREASED WINDE PEED RESISTANCE FOR VFJITS PER SECTION IVA OF TAS-N(A)AS WAS PERFURMEDTOTASZaZd MOM.AN OWAtLAMONH13GHTNOTTO ETC£fERFEETZAPPUCASM 2.ANCHORTYPEARDSQ£: L4 PIU CONST aUC170 MATERIALSIECHNOtOGTTFSFPEPORT NLESdO2d2-01,DATED A=TT.TASt00(WOSTESFEO UM-NIGH PROFILE 11, FORMSTALLATIONINFO WOOD FRANWG,USEOIOWUOD SCREWS ORMO SELF•TAPPfNrdSELP-OWILI-i SCREWSOFSURIGtENF[ENOIN SIMPEO COHCRETERCOF TIRES, TOACME.VE t tNMCH MROMWAEMeEDMENFIM0S2 WOODSTRVG/URALSUB.yTIULTC.MIHOWM EDGEORTANCELSSf4 WCf1E5ANO 2,4.1. THE PRODUCTHAS TESTED FDRLNNODRWElNRARi RE3N5TANCEPERTA'YtaOjA}85.5ECT20N tOJANDFOURETO DEIN CONFORNAi10ETYRN NINfMUN END 015TAHCE63161NCNE5. CHAPTERISOFTISFBC.ANWSTAL"MCNIMIGMNGTTOMCeM75r=tSAPPUCXUAIL 2T. FOR INSTALLATION INTOWALL OR ROOF SHEATHING,USE NO SIaF-TAPPINGSELF4RRJJNGSGR OPSUFFICIENFLENGRITO ACHEVE PUMTNREAD ENDEDMFItI'IMO STRUCTUA/LL SIIDSTRATE SELF•TAPPMGSELf•ORIlL1NGSCR£WS(4k.A.5NEETMETALSCREVFSIARE 3. FDRROOFMOUNTWG:ADEOVACY OF THE CXISNRGSFRUCTURAL RDD,SHFATMNOANDSUPPNNNGI2 FRAMMGASAMAMYRND FORCE TFlREAQ@THE FVLLLFNGRt AFM REOVIREDTO ENSURE KtNiItIiEADENGCyaENttNTOSNEATRWG. RESISTING SYSTEM CAPABLE CFWRHSTANOWGANOIRA}iSFEPWNDAPPLIED PRODUCTLOADSTOTNE FOUNDATION IS THE RESFONSIARIFf OF 2S ANGNORSPECDICATIONS T MGINCMORMCMME OFMCOMFORTIEPROJECFOFMSTAUAMM. 521 WOOD SCREM%ILL DE NO.tO PAN NFJIDWOOD SCREW.MEETING ANS101&41,CARBON OR STAVOXS55TEELCORItOS10N RESiSTAM eY COAT MG OR NATERibi,. d. FORVIMOUHTW6 ATOADLES:At)MMCYOFTICODSUNOSTRUCTURALWALLSNEA7MHGNIDSUPPORTING2XF AIROASAMAIN"ND 3]3 TAPDMG SCREWSSNALLOEN0.t01YPE AOPJW HFADTl1PPMGSGitiv MEENIGASMFJAN5101284 CARAOM OR STAWIEI3`+iIEEL A FORCE RESISTING SYSTEM CAPABLE OF VATNS7ANDING AND TRANSFERRIN-APPLIED PRCOUCTtOADSTO THEFOUNDANON ISTNERESPONSIBILIIY COmOSIONRESISTAMGYCOATINDOAMATEMAL OFTNE OlMNEFR ORARCINftECS OFAECOAD FORTiNEPRGNECi OF WSTALLANOR MDAMUMENBEDNIMTANO EOGEOISTANDE£SDiVOEROOFMGFVi6ttE5.WCLtlmlippUFNDTLLXJFFDTO ROOFQIiIiilRl+G.ROOFTRE. S. THE INSTALLATION DETAIS DESCM/ED HEREINARE GENEOCAND MAYNCTREPLECFACTUAL CONIMMORS FOR A SPECIFIC SITE IFS(FE S"'LE.UNDERLAYMENTS,ETC. DONORIONS CAUSE INSTALIA710NTO OFNATE FlIOAI THEREQWIENEIOS DETAILED HEAEW ANCENSED ENWNEER Oq ARCHRECTSHALL PREPARESRC SPECiFlC UOCUMENTH POR S USEWD"n 000UMENF. t3MRALtA1tONANCNORCAPACtiIESPOAPRO0UCP531ERONAREDASEO pN SUBSTRAIEMATEAV3SnTTN iNEFQttDVANGPROPIXt�S: St. 2SYWOODF NG(FORM(WOOOFRAMINGMSTAON LLNOPTION) C, HOOD&FLASHING MATERUAL- 060 ALWJIIUtI 5.1-t. MORMOMSPECRIC GRATn`CFOAZO=MEHM¢ SIM FaNiMUM SP£4DiGGRkYiITtJF OS5MSIDEXYN2 i. PRIORTOAHURRICAHEORANRCMATED MGHWHO EVEN{TAE SOLARPANELOURLBE PLACEDIN THE REFRACTED POSTOONWHEAE S2. PLYWOOD-SPECIES- WI.2.O.4ORS(APAVOLUMARYPRODUGFSTANDAROPSN. APPLICABLE 521. PLYWOODSPIR ES GROUPGROTIIELCLAMTICANONSA5 REONPCO BYTNEFLpMDA BWLDUNGCOOEYAU.BE MEF. SS DSB.SHEATHINGGRADEMRpIYPTRNOEOUCOFtlS0TAAN Y. SOLAR ATN*FANMODW: ,L GSHGLA&4RCAROHS4=ADDUA1LRGtiMPO5C2}O OEKTLLBE NET. A.L. SOLAR ATTIC FANWTM PUSTRONABLEPNOTOVOLIMC PANEL ISHEET2)WOMASOWATT FAN MOTOR WASTESTED.THIS SOLARATTIC FAIT IS ALSO AVAILABLE IN 1224,34 AND eOWATTSIIESALLS-UCTURM.MC1XIGAHDANCH0WNGAREW NNCALFCR ALLSOLORPANELSDES fi ADDRIONALDOWALLAAONUMRATIONS FAN 512£REtdAt!lSCOH515T£HT.ONtY WATTACEVAAtFS. At PROOUCTS—NGT REMSTALLEb AT AH II£VATtONIXCEEMRCTS FEET 02 SOLAR AMC FAR WITHFIlEO HOW;ROFTLEFHOTOVpLTl11t PANEL(5NE£TOj WRIIA24TYATTFAN MOTOR WASIESTEO. fit PRODUGTSHALL NOTBEINSTALLED ONWALLOR ROOFSHEATNMG LESS THAN BIB'IN TMCHE330RABLINRED BYTHEFLOMDA BUIIDMG COOL a SQNRATSIC FANMAY eE MSFAFi®ASFOLLDiYS: 83 PROOUCTCNi8E W5TALt,ED ON ROGFSURiIDHG SMNGLFS,TBES ORREMBiNHE.4 P.1. ON RAOFSVlIFH SLOPES FROM 9 DEGREES(T RREOVER 1T RW!)1045 DEGREES IRISE EQUATE RUN). - 9S. ONWALLS A7 GABLE ENDS. TO.TMSPRODDGr EVALUATION OGpUMENTAOORESSESTIIE STRUCTURALATTACHMENTOFTHE R00FVENT MINE ROOF SHEATHING ONLY. ROgERYJ,AMORUSQ PREPARATIONOFTH£ROOFSREATHINGMUMOPCOVEMNGIS)TORECEIVETINUROOFWWSHALt.BOPERTREM FACFUREASINSTRUCNONS AHDM=WftDANCELTIRt MtAPTER150FTNEFLOMOASUODOIGCODEAHDCHAMR9OFn4a FLCWDAMIDFNTIALCODL FLP1E-N0.477S2 11.TMSAPPROYALIS FORiHE SFRINCtURALAHO LWDi-0RIVEHSWNPERFORAWICEONLY.IMPACT'RESLSFANCE WAS NOTTESiFD.RRFAIOR Digitally MEp1A MWORELECT =R URYAREOVTSNETHESCOPEOFTNISPRODUCTAPPROVALDOCUMEM. signed by TABLE OF CONTENTS "�d•w RoberEJ SHEET DESCRIPTION DESIGN PRESSURE RATING(PSF) ``" = i�4=---r-@Amoroso 1 GENERAL AND INSTALLATION NOTES NATURAL LIGHT ENERGY SYSTEMS Tat�,.. �JE:Date: tOB21 N. 23rd AVE. ..z 2 ISOMETRIC VIEW-POSITIONASLE PHOTO VOLTAIC PANEL LOADING DIRECTION DPLLURATioNLPSFI PHOENIX, A2 85029 {2017.10.16 20:1154 3 ISOMETRIC VIEW-FIXED LOWPROFILE PHOTO VOLTAIC PANEL SOLAR ATTIC FAN -"W Posnre a(OO RiWARQ1 86.5 PSF POWERED BY PHOTO VOLTAIC PANELS 4 2X WOOD FRAMING INSTALLATION OPTION GENERAL NOTES 12472 LAKE 5 NEGATIVE(UPWARD) 175 ASF UNDEWRU.RD SHEATNiNG INSTALLATION OPftON-ANCHORAGE DETAILS ORAAY: owG Np my NO.148 SHEATHING N.'STACCATION OPTION-ANCHORAGE SCHEOULEB R.1A NLES-100 — ORLANDO.Fl.3782a 6 NOTES scR.E NTS 1°^1E 09/30/2017 5H-1 OF 6 °°mmSfHI+mt P'_NAONS ASI ,060.M16x .1 G_ KM10'r£0 ISOMETRIC VIEW LL�� POSITIONABLE PHOTO VOLTAIC PANEL PEKSPECTIVE VIED' NOTTOSC3LE ROSERTJ.AMORUSO l : { R—P.E.R0.4 M i Digitally signed b,Rob-aJ 4' :I yr.� Amoroso LEFT@TEIF NATURAL LIGHT ENERGY SYSTEMS r 10821 N. 23rd AVE. - ' Datc PHOENIX, A2 85029 �20:11:12-04W r„ SOLAR ATTIC FAN POWERED BY PHOTO VOLTAIC PANELS TOP V1Gi\" ISOMETRIC VIEW 12472 LAKE MOTTO SCAF.E mu�wr: oav xo. Pn UCiOERW48 RD RJA NLES-100 _ ORLANDO,FL 32828 Rs NTS GT'09/30/2017 —2 OF 6 --met II PEN9CNP PEY oEsoaaP"ron wre nPwrt� 0 x ISOMETRIC VIEW FIXED LOW-PROFILE PHOTO VOLTAIC PANEL ISOMETRIC TOR VIES"! TOP VIES"! 4 FRONT VIEW ROBERT J.AMORUSO FL P.E.NO.49752 Digitally ISOMETRIC BOTTOM VIEV! signed by o RobertJ NATURAL LIGHT ENERGY SYSTEMS !:,1, s�-f��3 Amoruso 10821 N. 23rd AVE. Date: PHOENIX, AZ 85029 ~� 2017.10.16 SOLAR ATTIC FAN 20'11.31 POWERED BY PHOTO VOLTAIC PANELS -0400 ISOMETRIC VIEW12472 LAKE UNOERHLLLRD rsuwn: pxc ero, re• NO.148 RJA NLES-100 _ ORIANDO.FL3282a sv+[ roe NTS —09/30/2017 —3 OF 6 1 com PLYWOOD OR OSB tlVLUROOySHE9gpNG INSTALLATION OPTION F.EN90.Y5 atv mscmPmx wh .vcarnm SOLAR PANEL ROOF SHEATHING COVERINGS ALLOWED. #8 X 314' PHSMS TYP. 1. ROOFING SHINGLES(SHOWN) ALLOWED. MEMBRANE ROOFING MATERIALS ALLOWED BASED 3116'ALUMINUM #BX 112• ON SHINGLE TESTING RESULTS. RIVETS TYP. PHSMS TYR 2, TILE(FLAT OR CORRUGATED) #10 SCREW(TYP.) ROOFING MATERIALS ALLOWED. SEE INSTALLATION NOTE 3. \\ 3. TYPICAL WALL COVERING S.,O.C. P `#10 SCREW(rYP.) ETC.MAT)RAi OIALSWEEOUCCO, SIDING. T�z SEE INSTALLATION NOTE 3. TK uPLYWOOD OR OSB SHEATHING.SEE INSTALLATION NOTE 5,SHEET 1 AND A ANCHOR SCHEDULE,SHEET S. #ta SCREW(TYP') SEE INSTALLATION NOTE 3. ELEVATION 27-itr 0 FLASHING SOLAR PANEL #8 X 314' 98 x 1/2' PHSMS TYP. PHSMS(TYP.) ALUMINUM 3116'ALUMINUM #8 X 112• q SUPPORT BRACKETS RIVETS TYP. PHSMS TYP. #10 SCREW(TYP.) SEE INSTALLATION NOTE 3. ROOF MOUNTED SOLAR =SCREW(TYP.) AMC FAN SEE INSTALLATION NOTE 3. ANCHOR LOCATION DETAIL LYWOOD OR OSB SHEATHING.SEE INSTALLATION NOTE S,SHEET 1 AND ANCHOR SCHEDULE,SHEET 5. RO8ERT J.AMORUSO NOTES: FL P.£NO.49T52 i. SEE SHEET 5 FOR INSTALLATION ANCHOR SCHEDULE SECTION A-A Digitally AND REQUIRED ANCHOR QUANTITIES, signed by 2. SEE INSTALLATION NOTES ON SHEET 1 FOR MATERIAL REQUIREMENTS AND SHEATHING �, ,, RObertJ THICKNESS. NATURAL LIGHT ENERGY SYSTEMS Z-�,„ti Amoroso 2.1. FOR THICKNESSES OTHER THAN THAT SHOWN 10821 N. 23rd AYE. _ Date: ON SHEET S.USE THE NEXT THINNER THICKNESS. PHOENIX, AZ 85029 2017.10.16 SOLAR ATTIC FAN 20:11:04 SHEATHING INSTALLATION OPTION SHOWN FOR ROOF INSTALLATION USING POWERED BY PHOTO VOLTAIC PANELS -000' POSITIONABLE SOLAR PANEL ATTIC FAN.INSTALLATION ALSO APPLICABLE PLYWOOD/OSB SHEATHING INSTALL. OPTION 12472 LAKE DNOERNtD.RO TO FIXED LOW-PROFILE SOLAR PANEL A171C FAN.SHEATHING OPTION CAN11.401 OwMN: OUG N0. N0..8.32828148 ALSO BE USED FOR GABLE END WALL INSTALLATION WITH EITHER ATTIC FRN. RJA NL£s-100 — 0�n.�m g"J NTS 09/30/2017 s" T5 OF 6 mmiasinM �1 II l Ii n�uwaNs PLYWOOD OR OSB WALU ROOF SHEATHING INSTALLATION OPTION Fkv OrsoeaneN r r neanmrn SUBSTRATE QUANTITY OF INSTALLATION ANCHORS AT VARIOUS DESiNG PRESSURES(psf) Type Thickness 42 Psf 48 psf 49 psf 50 psf 58 psf 63 psf 68 psi 70 psl 78 psf 82 psf 92 psf 2X FRAMING 14 ZO 10 10 10 10 10 10 10 10 10 WALLA200FSHFATHINGOPTIONINSTALtATtONANCHOR SCHEDULEAND 318" 10 10 10 t0 12 13 14 14 16 16 18 INSTALLATION NOTES: T116" 10 10 10 t0 to 10 10 10 11 12 13 1. SEE SHEET I.INSTALLATION NOTES FOR ANCHOR SEM,TYPE AND OSB 15132" 10 10 10 10 10 10 10 !0 10 11 12 EMBEDMENT REQUIREMENTS. 112" 10 30 10 10 10 10 10 10 10 10 11 2. TABLE AT LEFT SHOWS QUANTITY OF ANCHORS REQUIRED FOR THE 518" 10 10 10 10 10 10 10 10 10 10 10 FOLLOWING: 316" 10 10 70 10 10 10 10 10 10 10 10 2./. VARIOUS DESIGN PRESSUES(DP)IN POUNDS PER SQUARE FOOT 71161' 10 10F00 10 10 10 10 10 10 10 10 (PSF)" Plywood 1 15132" 10 30 10 10 10 40 10 10 10 10 22- PLYWOOD(SPECIES GROUPS 1 THROUGH 5- SEE INSTALLATION NOTE 52 ON SHEET 1). 112" 10 10 10 10 10 10 10 10 10 10 2.3. OSS(SHEATHING GRADE-SEE INSTALLATION NOTE 5.3 ON SHEET 1) 518" 10 10 10 10 t0 10 10 1Q 10 30 3. USETHIS TABLE AS FOLLOWS: 318" 10 10 10 10 11 12 12 13 14 15 3.1. DETERMINE THICKNESS AND TYPE OF WALL OR ROOF SHEATHING. Tt16" !0 30 10 !0 t0 t0 SO 79 T2 t3 32 DETERMINE REQUIRED NEGATIVE(UPLIFT)DESIGN PRESSURE FGR PROJECTS PHYSICAL LOCATION. Plywood 15132" 10 10 10 10 10 10 10 11 11 13 3.3. ENTERTABLETO DETERMINE QUANTITY OF ANCHORS 1/2" 10 10 t0 10 10 10 10 10 11 12 (SELF-TAPPING SCREWS REQUIRED FOR SHEATHING ONLY WHERE 510"' 10 10 1 10 10 10 10 10 10 10 10 ANCHORS WILL NOT ENGAGE IN 2X FRAMING). 318" 10 11 1t 11 13 14 15 15 j 17 M1416 4. QUANTITY OFANCHORS SHALL NEVER BE LESS THAN TEN(10). 7116" 10 10 10 10 11 12 12 13 14 S. SPACING SHOWN ON SHEETS 4 8 5 BASED ON THE FOLLOWING. Plywood 3, 5.1. QUANTITY OFANCHORS TEN(11)), 4,5 15132" 10 10 10 10 70 1 t t2 12 to S.Z ANCHORS LOCATED IN CTRCt1LAR MANNER tN A PERB.tETE3T CIRCLE 112" 10 70 10 10 10 10 17 11 13 OF 25.1/T DIAMETER.578" 10 10 10 10 10 10 !0 10 10 5.3. TEN(10 ANCHORS)SPACED EVENLY ON 25-1t2'DIAMETER ARE SPACED 8-ON CENTER(O.C.). 6.4_ SPACING MAY BE LESS BUT CANNOT EXCEED B'O.C. SUBSTRATE QUANTITY OF INSTALLATION ANCHORS AT VARIOUS DESING PRESSURES(psf) 55. SPACING Wil BE LESS WHEN ANCHOR QUANTITY EXCEEDS TEN Type f Thickness 96 psf 108 psf 115 psf 120 psf 130 psf 140 psf 150 psf 160 psf 170 psf 175 psf (to)ANCHORS. 2X FRAMING 10 10 10 10 10 10 11 12 13 13 318" 19 21 23 24 26 27 29 31 33 34 7116" 14 16 17 17 19 20 21 23 24 25 OSB 15132" 12 14 15 15 16 18 19 20 21 22 118' 11 13 13 14 15 16 17 18 20 20 5181" 10 10 10 10 11 11 12 13 14 14 318" 10 11 12 12 13 14 15 16 17 to 7116" 10 10 10 11 11 12 13 14 15 15 ROBERT J.AMORUSO Plywood 1 75f32" 10 10 10 10 31 11 12 13 14 14 Ft_P.E.NO.49M 112" 10 10 10 10 10 11 12 12 13 13 Digitally 51a" 10 t0 10 10 10 i0 11 12 13 t3 signed by 318" 16 18 79 20 22 23 25 26 28 29 jJ%e:�2 RobertJ 7116'" 14 16 17 17 19 20 21 23 24 25f-at,Amonuo Plywood 2 15132" 13 15 16 16 17 19 20 21 23 23 NATURAL LIGHT ENERGY SYSTEMS ^,.d,r 'Date: 8' 12 S4 t5 15 16 t8 19 20 21 22 10821 N. 23rd AVE. ,;./2017.30.16 !t PHOENIX, AZ 55429 �� 20:30:48 518" 10 11 12 12 13 14 15 16 17 18 318" 21 24 25 26 28 30 32 35 37 41 SOLAR ATTIC FAN -04'Op' POWERED INS BY PHOTO VOLTAIC PANELS 7/16" 17 20 21 22 23 25 27 29 30 31 724TZ LAKE PI vood 3, SHEATHING INSTALL OPTIONS — SCHEDULE & NOTES Yv 15132" 1T i9 2D 21 22 24 26 27 29 30 UNDERHILL RD NO.140 4,5 112" 16 17 18 19 21 22 24 25 27 28 nuwN: vee N0. ten• _N0.748 518" 13 14 15 16 17 18 19 21 22 23 RJA NLES-100 — Ombee"—n—@ sc'tc NTS °"TE 09/30/2017 A=6 OF 6 S41"a' 1