HomeMy WebLinkAboutProduct Approval (2) CBUCK Engineering
IN
SpPclaltly Structural Englnpprinq CBUCK,Inc.Certificate of Authorization#8064
Evaluation Report
"Peel & SealT""'
Roof Underlayment REVIEWE FCR
CO®E COMPLIANCE
Manufacturer: ST. LUCIE COUNTY
MFM Building Products Corp. B®CC
525 Orange Street
Coshocton, Ohio 43812
(740) 622-2645
for Ale copy
Florida Product Approval
# FL 11842.2 R4
Florida Building Code 6th Edition (2017)
Method: 1 - D
Category: Roofing
Sub - Category: Underlayment
Product: "Peel &SealT"^"
Description: Self-Adhered Underlayment
Facsimile of digital copy signed by
Prepared by: James L.Buckner,P.E.
James L. Buckner, P.E., SECB Electronically signed and sealed documents shal
comply with the provisions of FAC Rule 61G15-23
Florida Professional Engineer#31242
Florida Evaluation ANE ID: 1916 • sL BUc���,,�
Project Manager: Diana Galloway ���Q ••' ��CENS�c''•.cgp
Report No. 17-131-P&S-ER * No 31242 * '_
(Revises 15-115-P&S-ER,FL11842.1 r3)
Date: 07/09/17 �?� = LU
0 ". STATE OF 14/
T
'•."LORIDP •' G� �
Contents: S/ONA`��
Evaluation Report Pages 1—5
CBUCK,Inc.dba CBUCK Engineering 2017.08.18 11:42:11 -04'00'
Phone:(561)491-9927•Email:cbuck@cbuckinc.net-Website:www.cbuckinc.net
Business:1374 Community Dr.,Jupiter,FL 33458•Corp/Mailing:2637 E.Atlantic Blvd,#34069,Pompano Beach,FL 33062
FL#: FL 11842.2 R4
Date: 07/09/17
CSUCK Engine=L=rinq Page rt No.: 2 -51-P&S-ER
. N
Speclalry Structural Englneerinq CBUCK,Inc.Certificate of Authorization#8064
Manufacturer: MFM Building Products Corp.
525 Orange Street
Coshocton,Ohio 43812
(740) 622-2645
http://www.mfmbp.com/
Product Name: "Peel &SeaITM"
Product Category: Roofing
Product Sub-Category Underlayment
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product Description: 45-mils thick (nominally), self-adhering, foil-faced, non-reinforced membrane
with rubberized asphalt, and a release liner.
Roll size: 36" wide x various lengths
Surface colors:Aluminum,Almond, Granite Gray&White
Product Material/ Material Type: Styrene Butadiene Styrene (SBS)
Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 6th Edition
(2017),Chapter 15.
Substrate(s): Plywood Deck
(Design of support is outside the scope of this evaluation)
Installation: General Installation Instructions:
• Product to be applied directly to a clean dry surface.
• Dust, dirt, oil, grease, moisture, debris and other loose materials or
contaminants must be removed prior to application.
• Check that all nails in deck are not protruding and re-fasten any loose
decking panels.
• Prime Substrate with asphalt base primer.
• Cut the membrane to appropriate length.
• Peel back the release sheet, align the membrane and press into place onto
roof deck.
• Apply with selvedge on upward slope.
• Overlap end laps a minimum of 6".Side laps must be a minimum of 3".
• Apply membrane perpendicular to roof slope on slopes 5 3:12 and parallel on
slopes>3:12•.
• After installation roll entire surface with a heavy weighted roller. Roll all side
and end laps.
• Store product in the carton in a dry place until ready to use. Keep product
out of direct sunlight.
0 Protect membrane from damage during construction.
• Apply membrane only in fair weather when the air, surface. and
membrane are at a minimum temperature of: 55` F
FL#: FL 11842.2 R4
Date: 07/09/17
ICE3UCK Engineering Page rt No.:3 of 5131-P&S-ER
SPL Clalty Structiural Enginserinq CBUCK,Inc.Certificate of Authorization/#8064
Installation shall comply with this report, applicable code sections of FBC 6th
Edition (2017) (subject to the Limitations and Conditions of Use .listed in this
Evaluation Report) and manufacturer's installation instructions as a
supplemental guide for attachment.
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM D 1970-15a — Specification Self-adhering Polymer Modified
Bituminous Sheet Materials Used as Steep Roof Underloyment for Ice Dam
Protection
Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the
prescribed standards in ASTM D 1970-15a standard version adopted by the
Florida Building Code 6th Edition (2017)for use as evaluated in this report.
Code Compliance: The product(s) described herein have demonstrated compliance with the
performance standards listed above as referenced in the current Florida
Building Code.
Evaluation Report Scope: This product has been evaluated in compliance with the building envelope
requirements of the Florida Building Code, as related to the scope section to
Florida Product Approval Rule 61G20-3.001.
Product Limitations and . Deck shall be in compliance with applicable building code.
Conditions of Use: • Installation is limited to use with approved roof coverings that are
mechanically fastened through the underlayment and is attached to the
sheathing or rafters.
• Minimum slope shall be 2:12 or greater.
• Not to be applied over EPDM rubber or urethane or urethane composite
insulations.
General Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under"Optional Statewide Approval".
• Option for application outside"Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others.
• This report is a building code product evaluation per FLPE rule (FAC) 61G15-36
to comply with Florida product approval rule (FAC) 61G20-3. This evaluation
report is part of the Florida Building Commission approval for the listed code
FL#: FL 11842.2 R4
Date: 07/09/17
CBUCK Engineering RepoPage rt No.:4 17-13
51-P&S-ER
Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
related criteria. This report by James Buckner, P.E. and CBUCK Engineering is
not .a design certification of code compliance construction submittal
documentation, per FBC section 107, for any individual structure, site specific
or permit design.
9 Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade&Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity through Keystone Certifications, Inc.
Referenced Data: 1. ASTM D 1970-01 Test
By PRI Construction Materials Technologies, Inc.
(FBC Organization ID#TST 1556)
Report No. MFM-005-02-01, Date: 8/29/05
2. ASTM D 1970-01 Test
By PRI Construction Materials Technologies, Inc.
(FBC Organization ID#TST 1556)
Report No. MFM-006-02-01, Date: 8/29/05
3. Equivalency of Test Standard Certification
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
4. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID#QUA 1824)
MFM Building Products Corp. Licensee#335
S. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
FL M FL 11842.2 R4
t Date: 07/09/17
CSUCK EnQlneerinPage rt No.:5 of 51-P&5-ER
SpL ctalfiy Structural Engtneprinq ceucK,Inc.Certificate of Authorization#8064
MFM Building Products Corp.
Product Illustrations
F+-
f I F.t
u
Peel & SealTM
y
lechnical Information
MFM Building Products Corp.manufactures a wide range of .♦♦ PREMIUM HT
innovative waterproofing products for the building industry.With more than
57 years of field experience,MFM products are engineered for superior TILE & METAL
performance and ease of installation.
DESCRIPTION PRODUCT DATA
Premium HT Tile&Metal"m is a self-adhering roof underlayment composed Installation Temperature Range >50"F<250°F .
of a high-grade,reinforced polyester fabric laminated to high-temperature
asphalt adhesive system rated to 250°F.It also features a fiberglass- Material Color White
reinforced core.A release liner protects the adhesive and is removed Roll Size/Rolls per Carton 36"x 67 ft-1 Roll per Carton
during installation.Product features.a 3"selvedge edge to ensure a secure,
monolithic seal.The surface fabric offers excellent traction for good footing Carton Weight 66 lbs
and for stacking tiles during construction.
Gross Area per Carton 200 ftz
USES Cartons per Pallet 30
Premium HT is intended to be used as a whole-roof underlayment.It will
withstand the high temperatures created by metal roofing and bonds well TECHNICAL SPECIFICATIONS
with foam adhesive systems and traditional nail-down tile roofs.It may also Property Test Method Result
be used underneath cedar shakes,and synthetic and asphalt shingles.
Material Thickness ASTM D 5147 60 Mils nom.
INSTALLATION Maximum Load MD ASTM D 2523/1970 >60 Ibffin-w
Premium HT installs directly to wood,OSB,metal or insulated roof deck,
where allowed by code.The roof deck surface must be clean and dry.It Maximum Load CMD ASTM D 523/1970 >40 Ibffin-w
will adhere best to a surface primed with an MFM-approved primer.
Corroded metal,OSB and masonry must be primed.See website for Low Temperature Flexibility ASTM D 1970 Pass
approved primers. Thermal Stability ASTM D1204/1970 Pass
• Install in a shingle-like manner so that water flows over the seams Dimensional Stability TAS 103 Pass
• Starting at the eave,unroll horizontally with the selvedge edge at the top Tear Strength MD ASTM D4073/1970 >90 Ibf
• Remove 12"-18"of the protective release liner,align and stick in place Tear Strength CMD ASTM D4073/16970 >55 Ibf
• Continue removing the release liner by pulling from underneath the roll Vapor Permeance ASTM E 96 50.1 perms
and press Premium HT into place as you go
• Position the next course of Premium HT so that it will cover the selvedge Nail Sealability ASTM D 970/7349 Pass
edge on the first course and install membrane Elongation MD ASTM D,2523/1970 >20%
• All edge laps must be a minimum of 3"or cover the selvedge edge and Elongation CMD ASTM D 2523/1970 >25%
6"for end laps
• Roll entire membrane with a large push roller,paying special attention Adhesion.to Plywood @ 75°F ASTM D 903/1970 z12 Ibf/ft-w
to all overlaps and seams Adhesion to Plywood @ 40"F ASTM D 903/1970 22 Ibf/ft-w
• Cover within 180 days
■ Metal drip edge,valley and wall flashings should be installed under the Accelerated Aging TAS 103 Pass
Premium HT membrane Ultraviolet Resistance TAS 103 Pass
• For vertical surfaces,it should extend up the wall a minimum of 3"and Puncture Resistance TAS 103 Pass
the exposed edge protected by metal flashing—Premium HT may also
be installed vertically on roofs with a.very steep pitch Wind Uplift TAS 103 Pass
• Depending upon the pitch,roll membrane either from the ridge or eave Tile Slippage Resistance TAS 103 Pass
• Minimum slope is 3:12 pitch unless limited by local codes 'Some results listed may be the test method criteria and not actual test results.
• For valleys,roll Premium HT the entire length of the valley—lap the
field Premium HT over the valley membrane a minimum of 3"prior to PRODUCT NUMBER I UPC CODE
the installation of the valley metal or self-adhering flashing
36"-47201 7 25799 47201 1
RE-ROOFING OVER PREMIUM HT TILE&METAL
Premium HT does not have to be removed for re-roofing.Make sure (jPremium
ROVALS
the original membrane is clean and smooth.If recovering with a self- HT Tile&:Building
l =Code
uire=Miami-DadeCounty
adhering product,prime the entire roof with an MFM-approved primer 103-95,Florid42 abefore applying new membrane.Mechanically-attached underlayments roved.Product realua
may be installed directly over the existing Premium HT membrane.
WARNINGS ull�
• Premium HT must be installed in accordance with local building codes
• When loading roof tiles,do not exceed a maximum stack of 8 tiles on 30-YEAR LIMITED WARRANTY
a 6:12 pitch—loading boards may be used on top of underlayment MFM Building Products Corp.(MFM)warrants materials to be free from
• Premium HT is a vapor barrier—allow for proper roof ventilation leaks caused by defects in material or manufacturing for a period of thirty
(30)years from the date of purchase when applied according to directions.
• DO NOT install over EPDM or TPO rubber roofing
■ DO NOT install over silicone caulking,or uncured solvents For the most current Installation Instructions,Warranties,Technical
or sealants Specifications and Approvals,visit www.mfmbp.com.
• Installer is responsible for compatibility with all caulks,sealants _
and primers M. M.eu��reiaedoou'cTs'coaPl
525 Orange Street,PO Box 340,Coshocton,Ohio 43812•Tel 800-882-7663•Fax 740-622-6161•www.mhnbp.com
TDS-Premium HT 07/19