Loading...
HomeMy WebLinkAboutProduct Approval v CC , i n^ .• ` �', 33! M a Y$YUF g B u^•��a.• d 611 ". "4� 2 eas Home i lug In ' User rbgistrAUon ? Hat Topics ! Submit Surcharge Stats&Fads publications i Contact Us SCIS Site htap ' Unks i Search 'Fl`orida .. • �! , 1u Product cUser l a USER:Public User P14dud AnRroyel Menu>Product or Aoollcation Search>ARvliutean List>Application Detail ' �r �r PL# FL17678-Rfi •! 1;'`"'� '' Application Type Revision Code Version 2017 Application Status Approved FILE Copj-'. Cemments Archived Product Manufacturer Drexel Metals;Inc. Address/Phone/Ercall 204 Railroad Drive Ivyiand,PA 18974 (502)303-1511 ,ash umate@d rexmet.com Authorized Signature Jason Shumate jehumateCodrexmet.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Ercall Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R.Priest Evaluation Report Florida L€cense PE-74021 Quality Assurance Entity Architectural Testing,Inc.,an Intertek Company Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden RE. Validation Checklist-Hardcopy Received Certificate of Independence EU77678 R6 COI DRXl 00 .6 2017 FBC Eyaluation Report NonHVHZ final.Ddf Referenced Standard and Year(of Standard) Standard veer ASTM B 117 2016 ASTM G 155 2005 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 580 2006 UL1897 ���� ®��2012 Equivalence of Product Standards • CertifiedifiedBy Sections from the Code �E1� p® ® COME COMOPLIANIGE Product Approval Method Method 1 Option D ST. L CI COUno 6 I� a Date Submitted 10/09/2018 B0C C Date Validated 10/09/2018 Date Pending FBC Approval 10/21/2018 t Date Approved 12/11/2018 Summary of Products FL# Model,Number or Name Description 17678.1 Drexel Metal Roofing Systems DMC 100NS,DMC 150SL,DMC 1505S,DMC 1755,UMC 2005,RMC 450, DMC 5V&DMC Corrugated Limits of use Installation Instructions Approved for use in HVHZ:No X7678 R6I DRXLSQO+Q FBG Ey�uatIon ReROrt NonHVHZ Approved for use outside HVHZ;Yes flilLRsal` Impact Resistant:N/A Verifled By:Zachary R.Priest PE-74021 _ Design Pressure:+0/-180 Created by Independent Third Party:Yes Other:See evaluation report for limits of use Evaluation Reports Fl 17678 R6 AE DFIX15001 6 2017 FBC Evaluation Report NonHVHZ i Created by Independent Third Party:Yes If:'r :vt:%t Contact v:2601 Blair Srana RFoad�.Taiflahassae FL 32399 Pane:850487-182b The State of Florida is an AAJEEO employer.S,vjight 2007-2013 Stale of Florlde.::2jdg2 lament::8, i v man:::Refund 5 at m nt Under Florida law,email addresses are public records.It you do not want your e-mail address released in response to a pubue-records request,do not send aledronic mall to this entity.instead, contact the ou'tce by phone or by traditional man.If you have any questions,please contact$50.487.139S.'pursuant to Seaton 455,27StI1,Florida Sta lutes,effective October 1,2012,licensees licensed under Chapter 45S,F5,must provide the Department with an email address if they have one.The emana provided may be used for official CommunlCatloA With the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address Which can be made avallable to the public.Ta determine If you are a licensee under Chapter 455,F S.,please dict JIM. Product Approval Accaptet Credit Card Sate Certificate of Authorization No.29824 CAW CREEK 17520 Edinburgh Dr 01 Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6'"EDITION(2017) Manufacturer: DREXEL METALS, INC. issued October 9, 2098 1234 Gardiner Lane Louisville, KY 40213 (502)716-7143 www.drexmet.com Manufacturing: Drexel Metals Association of Regional Manufacturers(DM-ARM) Quality Assurance: Architectural Testing, Inc.(QUA1844) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES En& Report No. Standard Year Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995 Architectural Testing(TST1558) 58389.01-12244 UL 580 2006 Architectural Testing(TST1558) 58459.01-122-44 UL 580 2006 Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003 Architectural Testing(TST1558) 82776.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing(TST1558) 82784.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing(TST1558) 83296.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing,Inc(an Intertek Company)(TST1527) H3245.01450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.02-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.01-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) 13391.01-450-44 UL 580 2006 Force Engineering&Testing(TST5328) 178-0054T-12 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 178-0055T-12 UL 580 2006 UL 1897 2012 Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003 PRI Construction Materials Technologies(TST5878) VLS-005-02-01 ASTM B 117 2016 TAS 110 2000 PRI Construction Materials Technologies(TST5878) VLS-004-02-01 ASTM G 155 2005a TAS 110 2000 PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-017-02-01 Rev 1 UL 580 2006 UL 1897 2012 DRX15001.6 FL17678-R6 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. .i CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC Enti Report No. Standard Year PRI Construction Materials Technologies(TST5878) DMC-018-02-01 UL 580 2006 • UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-024-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-033-02-01.1 UL 580 2006 • UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-037-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-037-02-02 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-038-02-01 UL 580 2006 UL 1897 2012 PRODUCT DESCRIPTION DMC 100NS Profile: 1 in.snap lock seam;Max.16 in.coverage Description: Non-structural,snap lock standing seam roof panel with integral perorated nail strip _ Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90;Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 16° Y6I"aa� DMC 150SL Profile: 1.5 in.snap lock seam; Max. 16 in.coverage Description: Non-structural,snap lock standing seam roof panel Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90; F =min.50 ksi; Shall conform with FBC Section 1507.4.3 T_— �2 L— DRX15001.6 FL17678-R6 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. � CREEK DREXEL METALS,INC. Metal Roofing CAL SERVICES,LLC DMC 150SS Profile: 1.5 in. mechanical seam; Max. 16 in.coverage _ Description: Non-structural,mechanical lock standing seam roof panel Material: Min.0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min. 16 ksi; Shall conform with FBC Section 1507.4.3 Min.24 ga.Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90;Fy=min. 50 ksi; Shall conform with FBC Section 1507.4.3 r z 9. ,2, -F 16" Material: Min.0.027 in.Zinc; Fy=min. 16 ksi; Shall conform with FBC Section 1507.4.3 I 15.T' DMC 175S Profile: 1.75 in.snap lock seam; Max. 18 in.coverage Description: Non-structural,snap lock standing seam roof panel Material: Min.0.032 in. Fluropon®coated ASTM B209 aluminum; Fy=min.24 ksi; Shall conform with FBC Section 1507.4.3 Min.0.040-inch Fluropon®coated ASTM 8209 aluminum(Fy=min.20 ksi); Shall conform with FBC Section 1507.4.3 Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90; F min.50 ksi; Shall conform with FBC Section 1507.4.3 18" DMC 200S Profile: 2 in.mechanical seam; Max. 16 in.coverage Description. Non-structural, mechanical lock standing seam roof panel Material: Min.0.040 in.Fluropon®coated ASTM 8209 aluminum;Fy=min.20 ksi; Shall conform with FBC Section 1507.4.3 Min.24 ga. Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 1„ � 2 2" 2" 1 I 16, I DRX15001.6 FL17678-R6 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. JCREEK DREXELMETALS,INC. Metal Roofing TECHNICAL SERVICES, LLC DMC 450 Profile: 1.5 in.snap lock seam; Max. 16 in.coverage Description: Non-structural,snap lock standing seam roof panel with concealed clip Material: Min.24 ga.ASTM A792 or ASTM A653; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 Min.0.032 in.Fluropon@ coated ASTM 8209 aluminum; Fy=min.24 ksi; Shall conform with FBC Section 1507.4.3 :1 2 Al I 16" DMC 5V I Profile: 3/8 in.ribs; Min.21 in.,Max.24 in.coverage Description: Non-structural,through fastened roof panel _ Material:wy Min.26 ga.Fluropon@ coated ASTM A792 or ASTM A653 G90;Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 Min.0.032 in.Fluropon@ coated ASTM B209 aluminum; Fy=min.23 ksi; Shall conform with FBC Section 1507.4.3 21"up to 24"Coverage i i3 DMC Profile: 1/2 in. corrugation;21 in.coverage _ Corrugated Description: Non-structural,through fastened roof panel Material: Min.26 ga. Fluropon@ coated ASTM A792 or ASTM A653 G90 ; Fy=min.40 ksi; Shall conform with FBC Section 1507.4.3 Min.0.032 in.Fluropon@ coated ASTM 8209 aluminum; Fy=min. 19 ksi; Shall conform with FBC Section 1507.4.3 25" 8 ill 7 1 2,_1 7 „ TZ DRX15001.6 FL17678-R6 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC LIMITATIONS 1. Fire classification is not within the scope of this evaluation. 2. This report is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be in accordance with FBC Section 1511. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6t'Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. •. ....... ....... 2018.10.09 _ 11 .21 .46 No 74021 � • �- -0400' 3' STATE OF O'• <v: ��'�• ••< O P••\�.� Zachary R.Priest P.E. i��Fss fO N AL �.�`%1:' Organization No.i n No.71021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest In any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A—Installation(12 pages) 2) APPENDIX B—Approved Roof Systems(8 pages) 3) APPENDIX C—Design Wind Loads (4 pages) DRX15001.6 FL17678-R6 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A INSTALLATION Note-Refer to the APPRovED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product- Installation Detail #9-15 HWH wood screw with sealing washer #10-14 HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion #10-15 HWH wood resistant in accordance with FBC section 1507.4.4. Fasteners screws with dual threads and sealing washer #10-13 PH wood screw #10-16 DP3 PH self- drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be #14-13 DP1 PH self- corrosion resistant in accordance with FBC section 1507.4.4. drilling screw f'— 3" Bearing Plates 18 ga.Bearing Plate 3� 24 ga.in-seam clip yy DMC 150SL Clip Clips 24 ga.SS in-seam clip tTu 16 �- L 24 ga.DMC 150SS Clip 3.. T S o -} o DRX15001.6 FL17678-R6 Page 1 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. DREXEL METALS,INC. C R E E K Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Installation Detail 24 ga.in-seam clip 1 / 24 ga.DMC 150SS Fixed 9 T Clip a o � o 26 ga.in-seam clip 26 ga.DMC 150SS Fixed Clip J� o 22 ga.SS in-seam clip y Bq 1$ Clips(Cont'd) 22 ga.DMC 150SS Clip LU i o e 0 �-.+y _9P 3. a 7 22 ga.in-seam clip 8p 18' 22 ga.DMC 150SS Fixed —f Clip o i o �`.1 O 61" 22 ga.base;24 ga.butterfly In-seam clip r rl,J` DMC 150SS Butterfly Clip r�:,..<�r :;,� ;�-: •. DRX15001.6 FL17678-R6 Page 2 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component Product Installation Detail ° 22 ga.base;24 ga.butterfly in-seam clip DMC 150SS Continuous Butterfly Clip 26 ga.in-seam clip DMC 150SS Utility Floating Clip Clips(Confd) 18 ga.in-seam clip DMC 175S UL Clip , / o r j 22 ga.SS in-seam clip 1 2g' DMC 200S Clip 2' T O 0 0 18 �, / 3n DRX15001.6 FL17678-R6 Page 3 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attifibutes that are not specifically addressed herein. CR E E K DREXEL METALS,INC. j� Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component- Product Installation Detail 18 ga.base;22 ga.butterfly in-seam clip;4.5 in.length : DMC 200S Butterfly Clip 0 e� 18 ga.base;22 ga.butterfly in-seam clip;120 in.length;top slider 12 in.o.c. DMC 200S Continuous '`=✓-''"'` _,� Butterfly Clip Clips(Cont'd) :-`f✓-" -' s' 24 ga.in-seam clip DMC 450 Clip e 24 ga.SS in-seam clip DMC 450SS Clip Sealants Bostik 70-05A Shall be applied in continuous beads along the seam Bostik Chem-Calk 915 Fastening Details Nomenclature Attachment DMC 10ONS 10 - 13 PHW - -- DMC 10ONS Standard 1 J DRX15001.6 FL17678-R6 Page 4 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. C. CREEK DREXELM Roofing ng MetaltalRoofing TECHNICAL SERVICES,LLC APPENDIX A Component Product Installation Detail .,.;------DMC 10ONS PANEL _- BOSTIK 70-05A (2 3/16" BEADS) DMC 10ONS Enhanced - #10 13.PHW , DMC 150SL PANEL----, DMC 150SL CLIP-- #10-13PHW(2Per Clip)- UNDERIAYMENT--11 1 DMC 150SL Standard l �, 1 DMC 150SS PANEL�� DMC 1508S CONTINUOUS BUTTERFLY CLIP (2)010-13 PHW UNDERLAYMENT DMC 15OSS Continuous SUBSTRATE— Butterfly DMC 15OSS PANEL DMC 150SS BUTTERFLY CLIP (2)#10-13 PHW UNDERLAYMENT DMC 15OSS Butterfly SUBSTRATE t✓ d DRX15001.6 FL17678-R6 Page 5 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component Product Tinstallation Detail DMC 1509S PANEL--\ DMC 15OSS BUTTERFLY CLIP— (2)#14-13 PHDD UNDERLAYMENTV X 3x3-18GA BEARING PLATE���� ISO INSULATION METAL DECK DMC 15OSS#14 Butterfly I DMC 15OSS PANEL-------- 24 ANEL24 GA DMC 1508S FIXED CLIP \ (2)#10-13 PHW UNDERLAYMENT DMC 15OSS Fixed-90 SUBSTRATE .118'BEAD BOSTIK CHEM-CALK 916' APPLIED TO BOTH SIDES OF CUP �DG1C/BOSS PANEL 24 CA DMC 16855 FDIEO CLIP 114-BEAD BOSTIK CHEM.LK 9' -APPUED TOSOTH SIDE OF CUP DMC 15OSS#14 Fixed- 90 y 2 #14-13 DP1,PH Screws per clip;Clip installed over 18 ga.bearing late DMC 15OSS PANEL 24 GA DMC 150SS CLIP (2)#10-13 PHW UNDERLAYMENT DMC 15OSS Standard(At) .SUBSTRATE DRX15001.6 FL17678-R6 Page 6 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. a K DREXEL METALS,INC. Metal Roofing C RE im TECHNICAL SERVICES,LLC APPENDIX A Component_ Product Installation Detail • 1/4"BEAD BOSTIK70-05A—� DMC 150SS PANEL-----t 22 GA DMC 1508S FIXED CLIP---- DMC 150SS Fixed (2)#10-13 PHW Enhanced-90 UNDERLAYMENT SUBSTRATE 1 ANEL2DMC 150SS PANEL-------- 22 2 GA DMC 150SS FIXED CLIP , \ (2)#10-13 PHW UNDERLAYMENT DMC 150SS Fixed SUBSTRATE Enhanced-180 ` I IA"BEAD BOSTIK 70-05A DMC 150SS PANEL 22 GA DMC 150SS CLIP (2)#10 13 PHW DMC 150SS Enhanced(Al) UNDERLAYMENT SUBSTRATE �T DRX15001.6 FL17678-R6 Page 7 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. _ CREEK DREXELM o ng MetaltalRoofing TECHNICAL SERVICES, LLC APPENDIX A Component- Product TInstallation Detail • : DMC 15OSS PANEL -- ----- --� DMC 15OSS CLIP -- (2)#10-13 PH Screws UNDERLAYMENT---- DMC 15OSS Zinc SUBSTRATE— � I I . DMC 175S Panel--— , OMC 1755 UL (10.13 PN Screw�\ (2)per clip \\� DMC 175S#10 Standard DMC 1755 Panel DtdG 1755 UL Clip �'�-.,` 610-13 PH Screw- 12)per clip 114-BEAD BOSTK CHEM=CALK ... �' 915 MALE LEG AND BOTH SIDES •4'•+---.•�� OF CLIP 118-BEAD BOSTIK CHEM-CALK -- DMC 175S#10 Enhanced 915 ON FEMALE LEG t `; L DRX15001.6 FL17678-R6 Page 8 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. METALS,INC. CREEK DREXEL Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component: Product Tinstallation Detail DMC 1755 PANEL�\\ DMC 1755 ULCLIP�\ 014-13 DPI PHDDaPar Clip) \ 3X3-1GGA BEARING PLATE \ METAL DECK- 186 ECK 190 WSULATI04- DMC 175S#14 Standard DMC 200S PANEL DMC 200S BUTTERFLY CLIP--� (2)#10-13 PHW---� UNDERLAYMENT SUBSTRATE DMC 200S Butterfly �l Y DIVIC 200S PANEL--\ DMC 200S BUTTERFLY CLIP #10 - 16 DP3 PHD:LQ\ UNDERLAYMENT `\ METAL DECK \\ DMC 200S Butterfly(Steel) Use 18 ga.bearing plate over polyisocyanurate insulation DRX15001.6 FL17678-R6 Page 9 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. C. DREXELM CREEK Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component Product Finstallation Detail DMC 200S PANEL DMC 200S,CONTIN®US BiJTTERLY CLIP #10 - 16 DP3 PHD ' UNDERLAYMENT DMC 200S Continuous METAL DECK- l Butterfly(Steel) Use 18 ga.bearing late over polyisocyanurate insulation DMC 200S PANEL DMC 206S CLIP (2)#10-13 PHW— UNDERLAYMENT SUBSTRATE— DMC UBSTRATE-DMC 200S Fixed 1/4"BEAD BOSTIK 7b-05A DMC 200S PANEL DMC 200S CLIP (2)#10-13 PHW ~ DMC 200S Fixed Enhanced UNDERLAYMENT SUBSTRATE— DRX15001.6 FL17678-R6 Page 10 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX A Component= Product Installation Detail DMC 450 PANEL�� DMC450 CLIP ;910- 13 PHW(2 Per Clip) DMC 450 Standard DMC 450 PANEL DMC 450 SS CLIP _`- 010- 13 PHW(2 Per Clip) DMC 450SS Standard \ 99-05 HWH WOOD SCREW W" �SEALItJG WASHER DMC 5V Standard #10-14 DREXMET WOODSCREW DMC 5V PANEL -- METSHIELD HT UNDERLAYMENT ---� DMC 5V#10 Standard PLYWOOD �t t DRX15001.6 FL17678-R6 Page 11 of 12 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CRK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A Component Product Installation Detail DMC 5V PANEL —'- #10-14 DREXMET WOODSCREW- --- , UNDERLAYMENT --, 7/16°OSB MIN: \ DMC 5V Pan Fastening +. '. -- ONLY REQUIRED AT PANEL ENDS I It V-9" COVERAGE 10-15 HWH WOODSCREW(DUAL THREAD) 12"o.c. to 36"o.c. MAX. ROW SPACING DMC Corrugated UNDERLAYMENT 15/32" VIN. PLYWOOD DRX15001.6 FL17678-R6 Page 12 of 12 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B APPROVED ROOF SYSTEMS The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system. 5. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga(Fy=min.33 ksi)Wide Rib Deck(Type WR) conforming to ANSI/SDI-RDI.0&FBC. 6. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood sheathing at maximum 24-inch span. Roof System Numbers and Definitions 100NS-W# DMC ICONS over Wood Deck New or Existing) 150SL-W# DMC 150SL over Wood Deck(New or Existing) 150SS-S# DMC 150SS over Steel Deck New or Existing) 150SS-W# DMC 150SS over Wood Deck New or Existing) 175S-S# DMC 175S over Steel Deck New or Existing) 175S-W# DMC 175S over Wood Deck new or Existing) 200S-S# DMC 200S over Steel Deck New or Existing) 200S-W# DMC 200S over Wood Deck New or Existing) 450-W# DMC 450 over Wood Deck New or Existing) 5V-W# DMC 5V over Wood Deck New or Existing) COR-W# DMC Corrugated over Wood Deck New or Existing) Approved Systems for DMC 100NS over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment - Roof Panel Panel Attachment MDP No. (Psf) 100NS-W1 Min.15/32 OPTIONAL As required per FBC 24 ga. DMC 100NS DMC 100NS Standard attachment -97.5 CDX plywood Versashield Solo Max.16-Inch wide with fastener spaced 10.5 in.o.c. 100NS-W2 Min.15/32 OPTIONAL As required per FBC 24 ga.DMC 100NS DMC 100NS Standard attachment -120 CDX plywood Versashield Solo Max.16-inch wide with fasteners spaced 5.25 in.o.c. 100NS-W3 Min.15/32 OPTIONAL As required per FBC 24 ga.DMC 100NS DMC 100NS Enhanced attachment -135 CDX plywood Versashield Solo Max.16-inch wide with fasteners spaced 5.25 in.o.c. DRX15001.6 FL17678-R6 Page 1 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. D DREXEL METALS,INC. R V Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 150SL over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (Psfl Min.15132 OPTIONAL 24 ga.DMC 150SL DMC 150SL Standard attachment 150SL-W1 Min. plywood Versashieid Solo As required per FBC Max.16-inch wide with clips spaced 16 in.o.c. X2.5 Approved Systems for DMC 150SS over Steel Deck New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min.22 ga. Min.1 in.Approved 24 ga. DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S1 Type B, As required polyisocyanurate As required per FBC Max. 16-inch wide with clips spaced 36 in.o.c. -41.7 Grade 80 Steel insulation board Min.22 ga. Min.1 in.Approved Approved ASTM D 24 ga.DMC 150SS DMC 15OSS#14 Fixed-90 attachment 150SS-S2 Type B, As required polyisocyanurate -71 Grade 80 Steel insulation board 1970 underlayment Max.16-inch wide with clips spaced 16 in.o.c. Min.22 ga. Min. 1 in.Approved 24 ga.DMC 15OSS DMC 15OSS#14 Butterfly attachment 150SS-S3 Type B, As required polyisocyanurate As required per FBC Max.16-inch wide with clips spaced 24 in.o.c. -92.4 Grade 80 Steel insulation board Min.22 ga. Min.1 in.Approved 24 ga.DMC 15OSS DMC 15OSS#14 Butterfly attachment 150SS-S4 Type B, As required polyisocyanurate As required per FBC Max.16 inch wide with clips spaced 18 in.o.c. -117.8 Grade 80 Steel Insulation board Min.22 ga. Min.1 in.Approved 24 ga.DMC 15OSS DMC 15OSS#14 Butterfly attachment 150SS-S5 Type B, As required polyisocyanurate As required per FBC Max.16-inch wide with clips spaced 12 in.o.c. -143.1 Grade 80 Steel insulation board Min.22 ga. Min.1 in.Approved 24 ga.DMC 150SS DMC 150SS#14 Butterfly attachment 150SS-S6 Type B, As required polyisocyanurate As required peJFBC Max.16-inch wide with clips spaced 6 in.o.attachment -168.5 Grade 80 Steel insulation board DRX15001.6 FL17678-R6 Page 2 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. DREXEL METALS,INC. CREEK Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for DMC 150SS over,Wood Dock(New or Existing) System Deck, Fire Barrier Underlayment Rod'f Panel' Panel A#f�6 rrient MDP No: ;(psi . 15/32 OPTIONAL Approved ASTM D 0.027"(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment Min 150SS-W1 CDX plywood Versashield Solo Approved underlayment Max. 15.7-inch wide with DMC 150SS Utility Floating Clips -78.5 180°seam spaced 18 in.o.c. Approved ASTM D 0.027'(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment Min.15/32 OPTIONAL 150SS-W2 CDX plywood Versashield Solo Approved underlayment Max. 15.7-inch wide with DMC 150SS Utility Floating Clips -86 180°seam spaced 6 in.o.c. Approved ASTM D 0.027"(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment Min.15/32 OPTIONAL 150SS-W3 CDX plywood Versashield Solo App underlayment Max. 15.7-inch wide with 26 ga. DMC 150SS Fixed Clips spaced -86 180°seam 18 in.o.c. 150SS-W4 Min. OPTIONAL DMC 150SS Standard attachment CDX plywood As required per FBC Max. 16-inch wide 0.032"Al DMC 150SS od Versashield Solo with clips spaced 1 16 6 in.o.c. -90 180°seam 150SS-W5 Min.plywood 24 ga.DMC 150SS OPTIONAL As required per FBC Max.16-inch wide DMC 150SS Fixed-90 attachment -90 CDX pllywood Versashield Solo 90°seam with clips spaced 16 in.o.c. DMC 150SS Min.15/32 OPTIONAL 24 ga. DMC 150SS Butterfly attachment 150SS-W6 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide with clips spaced 16 in.o.c. -99.25 180°seam Min. 15/32 OPTIONAL Approved ASTM D 0.027"(0.7mm)Zinc DMC 150SS DMC150SS Zinc attachment 150SS-W7 CDX plywood Versashield Solo 1970 underlayment Max.15.7-inch wide with 26 ga.DMC 150SS Fixed Clips spaced -108.5 180°seam 9 in.o.c. DMC 150SS Min. 15/32 OPTIONAL 24 ga. DMC 150SS Continuous Butterfly 150SS WS As required per FBC Max. 16-inch wide 114.25 CDX plywood Versashield Solo 180°seam attachment with fasteners spaced 12 in.o.c. Min.15/32 OPTIONAL 24 ga. DMC 150SS DMC 150SS Fixed Enhanced-90 150SS-W9 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide attachment -150 Min.90°seam with clips spaced 12 in.o.c. Min.15/32 OPTIONAL 24 ga. DMC 150SS DMC 150SS Fixed Enhanced-180 150SS-Wl0 CDX plywood Versashield Solo As required per FBC Max.16-inch wide attachment -165 Min. 180°seam with clips spaced 8 in.o.c. DRX15001.6 FL17678-R6 Page 3 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. �- GD E E K DREXEL METALS,INC. j"t Metal Roofing MIIII TECHNICAL SERVICES,LLC APPENDIX B Approved Systems for DMC 150SS over Wood Deck(New or Existing) System Deck Fire Barrier _Underlayment Roof Panel Panel Attachment MDP No. (pso 0.032"AI DMC 150SS Min. 15/32 OPTIONAL DMC 150SS Enhanced(Al)attachment 150SS-W11 CDX plywood Versashield Solo As required per FBC Max.16-inch wide with clips spaced 8 in.o.c. -180 180°seam Approved Systems for DMC 175S over Steel Deck New or Existing) System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP No. (psf) Min. 1 in.Approved Min.22 ga. 24 ga.DMC 175S DMC 175S#14 Standard attachment 175S-S1 Type B Steel As required polyisocyanurate As required per FBC Max.18-inch wide with clips spaced 36 in.o.c. -60 insulation board Min. 1 In.Approved 175S-S2 Min.22 ga. As required polyisocyanurate As required per FBC Max. AI DMC 175S DMC 1755#14 Standard attachment -88 Type B Steel insulation board Max.17.5-inch wide with clips spaced 18 in.O.C. Min.22 ga. Min.1 in.Approved 24 ga.DMC 175S DMC 175S#14 Standard attachment 175S-S3 As required polyisocyanurate As required per FBC -105 Type B Steel insulation board Max.18 inch wide with clips spaced 6 in.O.C. Min.1 in.Approved Min.22 ga. 0.040"AI DMC 175S DMC 175S#14 Standard attachment 175S-S4 Type B Steel As required polyisocyanurate As required per FBC Max.17.5-inch wide with clips spaced 12 in.o.c. -129.25 insulation board Approved Systems for DMC 175S over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (pso Min.15/32 OPTIONAL 0.032°AI DMC 175S DMC 175S#10 Standard attachment 175S-Wi CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 24 in.o.c. -52.5 Solo Min.15/32 OPTIONAL 0.032'AI DMC 175S DMC 175S#10 Standard attachment 175S-W2 CDX plywood Versashield As required Solo per FBC Max.18-inch wide with clips spaced 18 in.o.c. X9'4 DRX15001.6 FL17678-R6 Page 4 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. -��o AG R K DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved,Systems for DMC 175S over Wood Deck(New or Existing) SystemMDP No. I Deck Fire Barrier, Underlayment Roof.Panel Panel Attachment' �ps� Min.15/32 OPTIONAL 0.032°AI DMC 175S DMC 175S#10 Standard attachment 175S-W3 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 12 in.o.c. -66.4 Solo Min.15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment 175S-W4 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 8 in.o.c. -71 Solo Min.15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Enhanced attachment 175S-W5 CDX plywood Versashield Approved ASTM D 1970 underlayment Max.18-inch wide with clips spaced 12 in.o.c. -71 Solo ASTM D 226,Type II roofing felt attached per Min.15/32 1518.2.1 with nails and tin caps per 1517.5 0.032°AI DMC 175S DMC 175S#10 Standard attachment 175S-W6 CDX plywood followed by Metshield High-Temp Max.18-inch wide with clips spaced 24 in.o.c. 74.75 Underlayment self-adhered to felt Min.15/32 OPTIONAL 0.032"AI DMC 175S DMC 175S#10 Standard attachment 175S-W7 CDX plywood Versashield As required per FBC Max. 14-inch wide with clips spaced 12 in.o.c. -82.5 Solo Min.15/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment 175S-W8 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 16 in.o.c. -84.25 Solo Min.19/32 OPTIONAL 24 ga.DMC 175S OMC 175S#10 Standard attachment 175S-W9 CDX plywood Versashield As required per FBC Max.16-Inch wide with clips spaced 25 In.o.c. -97.5 Solo Min.15/32 OPTIONAL 0.040°AI DMC 175S DMC 175S#10 Standard attachment 175S-W10 CDX plywood Versashield As required per FBC Max.17.5-inch wide with clips spaced 18 in.o.c. -106.75 Solo Min.15/32 OPTIONAL 24 ga.DMC 175S DMC 175S#10 Standard attachment 175S-W11 CDX plywood Versashield As required per FBC Max.18-inch wide with clips spaced 8 in.o.c. -121.75 Solo ASTM D 226,Type II roofing felt attached per 175S-W12 Min.15/32 1518.2.1 with nails and tin caps per 1517.5 0.032°AI DMC 175S DMC 1755#10 Standard attachment -131 CDX plywood followed by Metshield High-Temp Max.18-inch wide with clips spaced 6 in.o.c. Underlayment self-adhered to felt OPTIONAL 175S-W13 Min.19/32 Versashield As required per FBC 24 ga.DMC 175S DMC 175S#10 Standard attachment _135 CDX plywood Solo Max.16-inch wide with clips spaced 8 in.o.c. DRX15001.6 FL17678-R6 Page 5 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. C R E F.K DREXEL Metal Roofing fing Metal Roofing i TECHNICAL SERVICES, LLC APPENDIX B Approved Systeins for DMC 200S over Steel Deck New or Existing System Deck Fire Barrier Insulation„ Underlayment Roof Panel Panel Attachment MDP No. (pso Min.1 in.Approved 24 ga.DMC 200S 200S-S1 Min.22 ga. As required polyisocyanurate As required per FBC Max.16-inch wide DMC wButterfly(Steel)attachment with -88 Type B Steel insulation board 180°seam with clips spaced 24 in.o.c. Min.22 ga. 24 ga.DMC 200S DMC 200S Butterfly(Steel)attachment 200S-S2 Type B Steel As required None As required per FBC Max.16-inch wide with clips spaced 24 in.o.c. -91.75 180°seam Min.22 ga. Min.1 in.Approved 24 ga.DMC 200S DMC 200S Continuous Butterfly(Steel) 200S-S3 As required pclyisocyanurate As required per FBC Max.16-inch wide -121.75 Type B Steel insulation board 180°seam attachment with clips spaced 12 in.o.c. Min.22 ga. 24 ga.DMC 200S DMC 200S Continuous Butterfly(Steel) 200S-S4 Type B Steel As required None As required per FBC Max.16-inch wide attachment with clips spaced 12 in.o.c. -151.75 180°seam Approved Systems for DMC 200S over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (psf i DMC 200Sa. Min.15/32 OPTIONAL 24 gDMC 200S Butterfly attachment 200S-W1 CDXI ood Versashield Solo As required per FBC Max.16-inch wide -67.5 p 180°seam with clips spaced 24 in.o.c. 040"Al DMC 200S Min.15/32 OPTIONAL 0. DMC 200S Butterfly attachment 200S-W2 CDX plywood Versashield Solo As required per FBC Max.16-inch wide with clips spaced 24 in.o.c. -75 180°seam 0.040°AI DMC 200S 200S-W3 Min. OPTIONAL As required per FBC Max. 16-inch wide DMC Fixed attachment _105 CDX plywood Versashield Solo 180°seam with cllipsips spaced 16 in.o.c. 040°AI DMC 200S Min.19/32 OPTIONAL 0. DMC 200S Fixed Enhanced attachment 200S-W4 CDX plywood Versashield Solo As required per FBC Max.16-inch wide with clips spaced 8 in.o.c. -180 180°seam DRX15001.6 FL17678-R6 Page 6 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. GREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B Approved Systems for DMC 450 over Wood Deck(New or Existing) System . Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No:, (Psfl 450-W1 Min.19/32 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment -30 CDX plywood Versashield Solo Max.16-inch wide with clips spaced 24 In.o.c. Min.15/32 OPTIONAL 0.032"AI DMC 450 DMC 450SS Standard attachment 450-W2 CDX plywood Versashield Solo As required per FBC Max.16-Inch wide with clips spaced 16 in.o.c. 45 450-W3 Min.19/32 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment -67.5 CDX plywood Versashield Solo Max.16-inch wide with clips spaced 15.5 in.o.c. 450-W4 Min.15/32 OPTIONAL As required per FBC 0.032"AI DMC 450 DMC 45OSS Standard attachment -75 CDX plywood Versashield Solo Max.16-inch wide with clips spaced 6 in.o.c. 450-W5 Min.19/32 OPTIONAL As required per FBC 24 ga.DMC 450 DMC 450 Standard attachment -82.5 CDX plywood Versashield Solo Max.16-inch wide with clips spaced 6 in.o.c. Approved Systems for DMC 5V over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (psf) OPTIONAL ASTM D 226,Type If roofing felt attached per 0.032"AI DMC 5V DMC 5V#10 Standard attachment Min.15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to 5V-W1 CDX plywood Approved fire barrier followed by Metshield High-Temp Max.24-inch with ling washers HWH wood screws with -56 or insulation Underlayment self-adhered to felt coverage sealing washers spaced 18 in.o.c. 26 ga.DMC 5V OPTIONAL DMC 5V Standard attachment Min.15/32 Min.21-inch to 5V-W2 Approved fire barrier As required per FBC with#9-15 HWH wood screws with -60 CDX plywood or insulation Max.24-inch sealing washers spaced 16 in.o.c. coverage OPTIONAL ASTM D 226,Type II roofing felt attached per 26 ga.DMC 5V DMC 5V#10 Standard attachment Min.15/32 1518.2.1 with nails and tin caps per 1517.5 Min.21-inch to 5V-W3 CDX plywood Approvedins fire barrier followed by Metshield High-Temp Max.24-inch with ling washers HWH wood screws with -71 or insulation Underlayment self-adhered to felt coverage sealing washers spaced 24 in.o.c. DRX15001.6 FL17678-R6 Page 7 of 8 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. METALS,INC. CREEK DREXEL Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B Approved Systems for DMC 5V over Wood Deck(New or Existing) System Fire Barrier/ MDP -:Deck Underlayment Roof Panel Panel Attachment No. Insulation Deck 26 ga.DMC 5V OPTIONAL � DMC 5V Pan Fastening attachment 5V-W4 Min.7/16 OSB Approved fire barrier As required per FBC Min.21-inch to with#10-14 HWH wood screws with -75 plywood or insulation Max.24-inch sealing washers spaced 16 in.o.c. coverage OPTIONAL 26 ga.DMC 5V DMC 5V Pan Fastening attachment Min.7/16 OSB Min.21-inch to 5V-W5 plywood Approved fire barrier As required per FBC -Ih with#10-14 HWH wood screws with -112.5 Max.. nc or insulation sealing washers spaced 8 in.o.c. coverage 26 ga.DMC 5V OPTIONAL DMC 5V Standard attachment Min.15/32 Min.21-inch to 5V-W6 CDX plywood Approved fire barrier As required per FBC -inch with#9-15 HWH wood screws with -121.75 Max.. or insulation sealing washers spaced B in.o.c. coverage ASTM D 226,Type II roofing felt attached per 26 ga.DMC 5V or Min.15/32 1518.2.1 with nails and tin caps per 1517.5 OPTIONAL 0.032"Al DMC 5V DMC 5V#10 Standard attachment 5V-W7 Approved fire barrier Min.21-inch to with#10-14 HWH wood screws with -206 CDX plywood or insulation followed by nself ad High-Temp to felt Max.24-inch sealing washers spaced 6 in.o.c. Underlaymet self-adhered coverage Approved Systems for DMC Corrugated over Wood Deck(New or Existing) System Fire Barrier/ MDP Deck Underlayment Roof Panel Panel Attachment No. Insulation - (psf) Min.15/32 OPTIONAL 0.032"Al DMC Corrugated DMC 5V Corrugated attachment COR-W1 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -60 or insulation and sealing washer spaced 36 in.o.c. Min.15/32 OPTIONAL 26 ga.DMC Corrugated DMC 5V Corrugated attachment COR-W2 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -60 or insulation and sealing washer spaced 36 in.o.c. Min.15/32 OPTIONAL 0.032"Al DMC Corrugated DMC 5V Corrugated attachment COR-W3 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -135 or insulation and sealing washer spaced 12 in.o.c. Min.15/32 OPTIONAL 26 ga.DMC Corrugated DMC 5V Corrugated attachment COR-W4 CDX plywood Approved fire barrier As required per FBC Max.21-inch coverage with#10-15 HWH wood screws with dual threads -150 or insulation and sealing washer spaced 12 in.o.c. DRX15001.6 FL17678-R6. Page 8 of 8 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. �" DREXEL METALS,INC. l:.y Metal Roofing TECHNICAL,SERVICES,LLC APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-10 under the following provisions: 1. For Hip roofs between 2:12 and 5.6:12,Zone 3 shall be treated as Zone 2. 2. Wind speeds for risk category I, ll, III,and IV buildings shall be as defined in Section 1609 of the FBC. 3. Exposure B,C,and D shall be as defined in section 1609 of the FBC. 4. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 5. All calculations are based on an effective wind area of 10-fe or less. 6. Topographic factors such as escarpments or hills have been excluded from the analysis 7. Overhangs have been excluded from the analysis. 8. Wind directionality factor,Kd=0.85 9. Vu t is shown in the tables below.Design wind loads are calculated using V.gd=V„iA.6 per 1609.3.1. 10. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 11. Zones 1,2,and 3 shall be defined as shown below. Dimension"a°shall be 10%of the least horizontal dimension or(0.4 x Mean Roof Height),whichever is smaller,but not less than either 4%of the least horizontal dimension or 3ft Gable Hip a\ a _ 3 2 3 3 2 3 a �3 2 3 a 2 1 2 2 1 2 2 1 2 2 1 2 _ 1 3 2 3 3 2 3 a 3 2 3 a lal laIal la lal lal DRX15001.6 FL17678-R6 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEKDREXEL Metal l Roofing TECHNICAL,SERVICES,LLC APPENDIX C Gable/Hi Roofs in Exposure B Roof slope between 2:12 and 6.1:12 Building Mean Basic Wind Speed mph) ' Type Zone ,. Roof -20 130. 140 150 160 AM '180 190 `' 200 . Hei ht ft 20 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 -32.0 -35.6 39.5 25 -14.2 -16.7 -19.3 -22.2 -25.3 28.5 -32.0 -35.6 -39.5 1 30 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 -32.0 -35.6 -39.5 40 -15.4 -18.1 -21.0 -24.1 -27.4 -31.0 -34.7 -38.7 -42.9 50 -16.5 -19.3 -22.4 -25.7 -29.2 -33.0 -37.0 -41.2 -45.7 60 -17.3 -20.3 -23.5 -27.0 -30.7 -34.6 -38.8 -43.3 -47.9 20 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7 25 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7 Enclosed 2 30 -24.7 -29.0 -33.7 -38.7 -44.0 -49.7 -55.7 -62.0 -68.7 40 -26.9 -31.5 -36.6 -42.0 -47.8 -53.9 -60.4 -67.3 -74.6 50 -28.6 -33.6 -39.0 -44.7 -50.9 -57.5 -64.4 -71.8 -79.5 60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5 20 -36.6 -42.9 -49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6 25 -36.6 -42.9 -49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6 3 30 -36.6 -42.9 -49.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6 40 -39.7 -46.6 -54.1 -62.1 -70.6 -79.7 -89.4 -99.6 -110.3 50 -42.3 -49.7 -57.6 -66.2 -75.3 -85.0 -95.3 -106.1 -117.6 60 -44.4 -52.1 -60.5 -69.4 -79.0 -89.2 -100.0 -111.4 -123.4 20 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 -53.0 25 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 -53.0 1 30 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.8 -53.0 40 -20.7 -24.3 -28.2 -32.4 -36.8 -41.6 -46.6 -51.9 -57.6 50 -22.1 -25.9 -30.1 -34.5 -39.3 -44.3 -49.7 -55.4 -61.3 60 -23.2 -27.2 -31.5 -36.2 -41.2 -46.5 -52.1 -58.1 -64.4 20 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3 25 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3 Partially 30 -29.6 -34.8 -40.3 -46.3 -52.6 -59.4 -66.6 -74.2 -82.3 Enclosed 2 40 -32.2 -37.7 -43.8 -50.2 -57.2 -64.5 -72.3 -80.6 -89.3 50 -34.3 -40.2 -46.6 -53.5 -60.9 -68.8 -77.1 -85.9 -95.2 60 -36.0 -42.2 -48.9 -56.2 -63.9 -72.2 -80.9 -90.1 -99.9 20 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 25 -41.5 48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 3 30 -41.5 48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 40 45.0 -52.8 -61.3 -70.3 -80.0 -90.3 -101.3 -112.8 -125.0 50 -48.0 -56.3 -65.3 -75.0 -85.3 -96.3 -107.9 -120.3 -133.3 60 -50.3 -59.1 -68.5 -78.7 -89.5 -101.0 -113.3 -126.2 -139.8 DRX15001.6 FL17678-R6 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXELMETALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX C Gable/Hip Roofs in Exposure C Roof slope between 2:12 and 6.1:12 Building Mean Basi cWind S eed m h Zone Roof Type . , 120 1'30 .140 150 160 170 180 190 . 200 Height ft 20 -18.3 -21.4 -24.9 -28.6 -32.5 -36.7 -41.1 -45.8 -50.8 25 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 -42.9 -47.9 -53.0 1 30 -19.9 -23.4 -27.1 -31.1 -35.4 -39.9 -44.8 -49.9 -55.3 40 -21.1 -24.8 -28.7 -33.0 -37.5 -42.4 -47.5 -52.9 -58.7 50 -22.1 -26.0 -30.1 -34.6 -39.4 -44.4 -49.8 -55.5 -61.5 60 -22.9 -26.9 -31.2 -35.9 -40.8 -46.1 -51.6 -57.5 -63.7 20 -31.8 -37.3 -43.3 -49.7 -56.6 -63.8 -71.6 -79.8 -88.4 25 -33.2 -39.0 -45.2 -51.9 -59.1 -66.7 -74.8 -83.3 -92.3 Enclosed 2 30 -34.6 -40.7 -47.2 -54.1 -61.6 -69.5 -77.9 -86.8 -96.2 40 -36.8 -43.1 -50.0 -57.4 -65.4 -73.8 -82.7 -92.2 -102.1 50 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0 60 -39.9 -46.9 -54.4 -62.4 -71.0 -80.2 -89.9 -100.1 -111.0 20 -47.0 -55.2 -64.0 -73.5 -83.6 -94.4 -105.8 -117.9 -130.7 25 -49.1 -57.7 -66.9 -76.8 -87.3 -98.6 -110.5 -123.2 -136.5 3 30 -51.2 -60.1 -69.7 -80.0 -91.1 -102.8 -115.3 -128.4 -142.3 40 -54.4 -63.8 -74.0 -84.9 -96.6 -109.1 -122.3 -136.3 -151.0 50 -57.0 -66.9 -77.5 -89.0 -101.3 -114.3 -128.2 -142.8 -158.3 60 -59.1 -69.3 -80.4 -92.3 -105.0 -118.5 -132.9 -148.1 -164.1 20 -24.5 -28.8 -33.4 -38.3 -43.6 -49.2 -55.2 -61.5 -68.2 25 -25.6 -30.1 -34.9 -40.0 -45.6 -51.4 -57.7 -64.2 -71.2 1 30 -26.7 -31.4 -36.4 -41.7 -47.5 -53.6 -60.1 -67.0 -74.2 40 -28.4 -33.3 -38.6 -44.3 -50.4 -56.9 -63.8 -71.1 -78.8 50 -29.7 -34.9 -40.5 -46.4 -52.8 -59.6 -66.9 -74.5 -82.5 60 -30.8 -36.2 -41.9 -48.1 -54.8 -61.8 -69.3 -77.2 -85.6 20 -38.1 -44.7 -51.8 -59.5 -67.7 -76.4 -85.7 -95.4 -105.8 25 -39.8 -46.7 -54.1 -62.1 -70.7 -79.8 -89.5 -99.7 -110.5 Partially 30 -41.5 -48.7 -56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 Enclosed 2 40 -44.0 -51.6 -59.9 -68.7 -78.2 -88.3 -99.0 -110.3 -122.2 50 -46.1 -54.1 -62.8 -72.0 -82.0 -92.5 -103.8 -115.6 -128.1 60 -47.8 -56.1 -65.1 -74.7 -85.0 -95.9 -107.6 -119.8 -132.8 20 -53.3 -62.6 -72.6 -83.3 -94.8 -107.0 -119.9 -133.6 -148.1 25 -55.7 -65.3 -75.8 -87.0 -99.0 -111.7 -125.3 -139.6 -154.6 3 30 -58.0 -68.1 -79.0 -90.7 -103.2 -116.5 -130.6 -145.5 -161.2 40 -61.6 -72.3 -83.8 -96.2 -109.5 -123.6 -138.6 -154.4 -171.1 50 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.2 -161.8 -179.3 60 -66.9 -78.5 -91.1 -104.6 -119.0 -134.3 -150.6 t -167.8 -185.9 DRX15001.6 FL17678-R6 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. `µ CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL,SERVICES,LLC APPENDIX C Gable/Hip Roofs in Exposure D Roof slope between 2:12 and 6.1:12 Building Mean 'Basic Wind Speed mph) Type Zone Roof 120: 130 „ 140 Height 150 160:;. 170 180 190 . 200 ft. ;.. . 20 -21.9 -25.7 -29.9 -34.3 -39.0 -44.0 -49.3 -55.0 -60.9 25 -22.7 -26.7 -31.0 -35.5 -40.4 -45.6 -51.2 -57.0 -63.2 1 30 -23.6 -27.6 -32.1 -36.8 -41.9 -47.3 -53.0 -59.1 -65.4 40 -24.8 -29.1 -33.7 -38.7 -44.0 -49.7 -55.7 -62.1 -68.8 50 -25.8 -30.3 -35.1 -40.3 -45.9 -51.8 -58.0 -64.6 -71.6 60 -26.6 -31.2 -36.2 -41.6 -47.3 -53.4 -59.9 -66.7 -73.9 20 -38.2 -44.8 -52.0 -59.7 -67.9 -76.6 -85.9 -95.7 -106.0 25 -39.6 46.5 -53.9 -61.9 -70.4 -79.5 -89.1 -99.2 -110.0 Enclosed 2 30 -41.0 -48.1 -55.8 -64.1 -72.9 -82.3 -92.3 -102.8 -113.9 40 43.1 -50.6 -58.7 -67.4 -76.7 -86.5 -97.0 -108.1 -119.8 50 -44.9 -52.7 -61.1 -70.1 -79.8 -90.1 -101.0 -112.5 -124.7 60 -46.3 -54.3 -63.0 -72.4 -82.3 -92.9 -104.2 -116.1 -128.6 20 -56.5 -66.3 -76.8 -88.2 -100.4 -113.3 -127.0 -141.5 -156.8 25 -58.5 -68.7 -79.7 -91.5 -104.1 -117.5 -131.7 -146.8 -162.6 3 30 -60.6 -71.2 -82.5 -94.7 -107.8 -121.7 -136.4 -152.0 -168.4 40 -63.8 -74.8 -86.8 -99.6 -113.4 -128.0 -143.5 -159.9 -177.1 50 -66.4 -77.9 -90.4 -103.7 -118.0 -133.2 -149.4 -166.4 -184.4 60 -68.5 -80.4 -93.2 -107.0 -121.7 -137.4 -154.1 -171.7 -190.2 20 -29.4 -34.6 40.1 -46.0 -52.3 -59.1 -66.3 -73.8 -81.8 25 -30.5 -35.8 41.6 47.7 -54.3 -61.3 -68.7 -76.5 -84.8 1 30 -31.6 -37.1 43.0 -49.4 -56.2 -63.5 -71.2 -79.3 -87.8 40 -33.3 -39.0 -45.3 -52.0 -59.1 -66.8 -74.8 -83.4 -92.4 50 -34.6 -40.6 -47.1 -54.1 -61.6 -69.5 -77.9 -86.8 -96.2 60 -35.7 -41.9 -48.6 -55.8 -63.5 -71.7 -80.4 -89.5 -99.2 20 -45.7 -53.6 -62.2 -71.4 -81.2 -91.7 -102.8 -114.5 -126.9 25 -47.4 -55.6 -64.5 -74.0 -84.2 -95.1 -106.6 -118.8 -131.6 Partially 30 -49.1 -57.6 -66.8 -76.7 -87.2 -98.5 -110.4 -123.0 -136.3 Enclosed 2 40 -51.6 -60.6 -70.2 -80.6 -91.8 -103.6 -116.1 -129.4 -143.4 50 -53.7 -63.1 -73.1 -83.9 -95.5 -107.8 -120.9 -134.7 -149.2 60 -55.4 -65.0 -75.4 -86.6 -98.5 -111.2 -124.7 -138.9 -153.9 20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7 25 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.3 3 30 -68.7 -80.6 -93.5 -107.3 -122.1 -137.9 -154.6 -172.2 -190.8 40 -72.3 -84.8 -98.3 -112.9 -128.5 -145.0 -162.6 -181.1 -200.7 50 -75.2 -88.3 -102.4 -117.5 -133.7 -151.0 -169.2 -188.6 -208.9 60 -77.6 -91.1 -105.6 -121.2 -137.9 -155.7 -174.6 -194.5 -215.5 DRX15001.6 FL17678-R6 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein.