HomeMy WebLinkAboutProduct Approval 4 YOLTERS ENGINEERING ENGINEERING, DRAFTING,CONSULTING 15211 971h Road N West Palm Beach,FL 33412 Ph/Fx:(561)225-1982 PRODUCT EVALUATION PRODUCT: DYNAMIC 1" NAILSTRIP 24 GAUGE STEEL ROOF PANEL (FLPA#21388.1) MANUFACTURER: DYNAMIC METALS, LLC [-RECIEIVED 340 PIKE ROAD WEST PALM BEACH, FL 33411 NOV 04 ?01`9 ST. Lucie Country, Permitrting To all concerned, - The Dynamic 1" Nailstrip 24 Ga. Steel Roof Panel, manufactured by Dynamic Metals LLC, is a non- structural galvalume coated steel roof panel (50 ksi min) that meets the requirements of Section 1507.4.3 of the 6th Edition (2017) Florida Building Code. The panel has been tested per UL580-06 by Intertek-ATI, with results shown in test report G1195,06-450-44. Technical Documentation: 1. Drawing "NSS16"dated 6/18/18 , signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Charles Anderson, PE. 3. Supplemental Calculations to support"NSS16"drawing, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, for use outside of the HVHZ. R ��F Limitations: This panel is approved for use outside of the HVHZ. CODE CO/p��fl.. PL�IANCE p� Overall Limitations: Maximum Panel Width: 16 (naw a Fastener spacing across panels: 16"O.C. (at nailstrip) (Panels overlap with male/female snap fit) Maximum Design Pressure: 206 psf. Max. Fastener Spacing: 6"from ends, 6" max. O.C. Min. Panel Fastener: #10-9x1" Panclip MTW fastener 91ECIALIZING IN IMPACT M515TANT CUF\fAINVV&l,5, 5TOUPONT5, & WINPOW5 Underlayment: 1 layer of 30 Ib.organic felt paper with 4"overlaps (or) Any underlayment with a valid FLPA or Miami-Dade NOA Fire Barrier: 1 layer of VersaShield with 4"overlaps (or) Any fire barrier with a valid FLPA or Miami-Dade NOA Minimum Substrate: %' (15/32" min)4-ply CDX Plywood, nailed to 2x rafters spaced 24"max. O.C. with 8d ring-shank nails spaced 4"O.C. Other Limitations: Roof slope must meet requirements of FBC Section 1507.4.2. Fire classification is not a part of this evaluation. Shear diaphragm values are not a part of this evaluation. Design of substrate is by others and is not a part of this evaluation. If you have any questions or need more information concerning this approval please contact me. Thank you, o *cott FL PE# 62354 JUN 19 2018 .. �� 0NA4 5ITCKIZING IN IMPACT F�515TA !f CUFf'AINW&I,5, %OPERONT5, &WINMIV5 r C' 1 I I � II I � a � c � 0 0 DO CLr 0 0 li I r '` DYNAMIC METALS SCOTT WOLTERS - - - fi• -1'�� a FL PE/62354 - - - PALTERS tl1CINEQtINb• 340 PIKE ROAD www.d nomicmetoLnet (COAA 27194) =�Q y 15211 97TH ROAD N+T.) _ r m / WEST PALM BEACH,FL 33782 FAX:(561)629-7291 wmT pALN 6EAcH,FI.3341.i,''.;.uU 19 1014:' 157 SUBMITTAL H p I PH:(561)629-7288 EMAIL:info@dynamicmetotnet (561)225-19ti2 �. Ct h?:�',:'�C~-� PRINTS ISSUED FOR REVA DATE