HomeMy WebLinkAboutDrawing1. ,Accordion -Shutter "�.74
(Front Window)
2. Arcordion,Shutter..,-
:. 96482'. ,
-(Back Slfding Glass'Door)
3: Accordion Shutter
, ` 72 x 82
(Back.Sliding Glass Door)
4. Accordion Shutter "
74 x 63r,
- (6ack Window)
y
I,
„+
4
N
� 00
t)
Cu ;t
"E5 C)
O FL
L -0
Q CD
V 1-
N
O 0-
CD
LL
"TOSCALE
Information
Owner: Carney
Address: 6007 Adonidia PI
Ft Pierce, F134982
Building Information
Wind Zone: 160 MPH.
Exposure Category: B
Minimum Building Dimension: 24 ff.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening
Number
Location
Zone JL
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)IF
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1
End
74 63 7
30.0
-38.5
2
Int
— .—_.......... __-- ---
96 82 7
------
28.9
-31.6
3
Int
72 82 7
29.5
-32.3
4
End
74 63 7
30.0
-38.5
in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 61h Edition (2017) Florida Building Code.
Page 1 of I