Loading...
HomeMy WebLinkAboutDrawing 'Opening Size P J 1.`Accordion Shutter- ;914x84 (Lanai Area) 2,,'Accordion Shutter" - 113'x 84 i.`." (Lana!Area) 3."Accordion Shutter 108 x 82 (Lanai Area) 2 1 el 3 ILL t� -0 aj t > N Cf) �. CL COPYRIGHT E-TEMPE9T.CON SCALE: NOT TO SCALE DATE: Nov 05,2019 PAGE DESCRIPTION: Site Plan PAGE: OF� Property Information Building Information Owner: Schachel Wind Zone: 160 MPH. Address: 7 Rio Verde Way Exposure Category: B Port St Lucie,F134952 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: H Design Pressure Calculations Opening Location Device Device Device IF Max Positive Max Negative Number Zone I Width(in) F Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 114 84 7 28.5 -31.2 2 End 113 84 7 28.5 -35.5 3 End 108 82 7 28.6 -35.8 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Pagel of 1