HomeMy WebLinkAboutDrawing 'Opening Size
P J
1.`Accordion Shutter- ;914x84
(Lanai Area)
2,,'Accordion Shutter" - 113'x 84 i.`."
(Lana!Area)
3."Accordion Shutter 108 x 82
(Lanai Area)
2 1
el 3
ILL
t� -0 aj
t >
N Cf)
�. CL
COPYRIGHT E-TEMPE9T.CON
SCALE:
NOT TO SCALE
DATE:
Nov 05,2019
PAGE DESCRIPTION:
Site Plan
PAGE: OF�
Property Information Building Information
Owner: Schachel Wind Zone: 160 MPH.
Address: 7 Rio Verde Way Exposure Category: B
Port St Lucie,F134952 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: H
Design Pressure Calculations
Opening Location Device Device Device IF Max Positive Max Negative
Number Zone I Width(in) F Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 114 84 7 28.5 -31.2
2 End 113 84 7 28.5 -35.5
3 End 108 82 7 28.6 -35.8
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Pagel of 1