HomeMy WebLinkAboutproduct approval Certificate of Authorization No. 29824
.�, CREA..K 17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC
(813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: TAM KO BUILDING PRODUCTS, INC. Issued October 19, 2017
P.O. Box 1404
Joplin, MO 64802
(417)624-6644
hftr)://www.tamko.com
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKOO ASTM Slate ASTM D 6380, Class M,Type 11 underlayment constructed from organic felt saturated
Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKOO ASTM Tile ASTM D 6380, Class M,Type 11 underlayment constructed from an organic felt saturated
Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKOO Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated
Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKOO Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
Guard@ with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKOO No. 15 ASTM, ASTM D 226, Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO No.15 UL ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO No.30 ASTM ASTM D 226,Type II underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO No.30 UL ASTM D 226, Type 11 underlayment constructed from a non-perforated organic felt that is
Asphalt Saturated saturated with asphalt.
Organic Felt
TAMKOO TW Metal and Self-adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side.
TAMKOO TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
Underlayment polymer film on the surface and a removable release film on the adhesive side.
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS,INC.
CREEKTAMKO Underlayments
TECHNICAL SERVICES,LLC
TAMKO®TAM-FELT Alternate to ASTM D 226,Type I and Type II underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, 'the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
I` checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKOO TW Metal and Tile Underlayment and TAMKO@ TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO@ Moisture Guard@ shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKOO ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKOO TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverings:
Metal Roof Mineral Wood ."
Asphalt `' Paneis and Surfaced Roll Shingles and Slate Clay and
Underla inent .Shm less ' Shin les 'Roofin Shakes . Shingles . Concrete Tile
TAMKOO ASTM Slate Y N N N N Y
Surfaced Roll Roofing
TAMKOO ASTM Tile N N N N N Y
Underlayment
TAMKOO Master Smooth Y' N N N N N
TAMKOO Moisture Guard@) Y N N N N N
TAMKOO No.15 ASTM
Asphalt Saturated Organic Y Y Y YZ N N
Felt
TAMKOO No.15 UL Asphalt Y Y Y Y2 Y N
Saturated Organic Felt
TAMKOO No.30 ASTM
Asphalt Saturated Organic Y Y Y Y Y Y
Felt
TAMKOO No.30 UL Asphalt Y Y Y N Y N
Saturated Organic Felt
TAMKOO TW Metal and Tile Y Y N N N Y
Underlayment
TAMKO@)TW Underlayment Y Y N N N N
TAMKOO TAM-FELT Y N N N N N
Notes: 1)Open valley applications per 1507.2.9.2
2)Wood shingles only
TBP14001.4 FL12328-R8 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK !
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS,INC.
L77",
CREEKTAMKO Underlayments
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2)._Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
I
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. _
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies(TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
i PRI Construction Materials Technologies(TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies(TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC(TST9628) 13CA12269 ASTM D 226 2009
I
TBP14001.4 FL12328-R8 Page 3 of
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. !
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not.
specifically addressed herein. i
TAMKO BUILDING PRODCUTS,INC.
CREEKTAMKO Underlayments
TECHNICAL SERVICES,LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the-Florida Building
Code; 6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
tj't I u u u'r..��
EN*" -. 2017.10.19
12:15:5 8
o 74021 N
1- 21 5��
-04'00'
��•: STATE OFF
P '��: Zachary R. Priest, P.E.
• 0 R
�s ,4'••C?��`` Florida Registration No.74021
I ���•,S ONA� ���, Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
TBP14001.4 FL12328-R8 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
I _f