Loading...
HomeMy WebLinkAboutProduct Approval RECEIVED NOV 062019 MIAMI•DiADE ST, Lucie County.,Permitting MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidadg.gov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone. DESCRIPTION: GAF WeatherSideTM Fiber Cement Siding APPROVAL DOCUMENT: Drawing No. 2010.G33560CT, titled "GAF WeatherSide Profile 12, Purity Straight, Purity Thatched, Purity Wavy and Profile 9", sheets 1 through 3 of 3, dated 08/14/2013, with revision 03 dated 01/05/2018, prepared by Nemo etc., signed and scaled by Robert Nieminen, P.E., bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/ series and the following statements: "ASTM C 1186, Type A compliant" and "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA # 15-0128.01 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation w sqeTIM� M.Utrera,P.E.b NOA No.18-0327.09 rtivrttionne counrr t-WE: Expiration Date: October 31,2023 CODE F Approval Date: May 24,20e P ge18 1 m� ST. LUCIE C 7V OCC GAF . NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOAs A. DRAWINGS "Submitted under NOA #15-0128.01" 1. Drawing No. 2010.G33560CT, titled "GAF WeatherSide Profile 12, Purity Straight, Purity Thatched, Purity Wavy and Profile 9", sheets 1 through 3 of 3, dated 08/14/2013, with revision 02 dated 04/10/2015, prepared by Trinity ERD, signed-and sealed by Robert Nieminen, P.E. B. TESTS."Submitted under NOA #13-0604.07" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings of GAF-ELK WeatherSide Profile 12 Fiber Cement Siding, prepared by Farabaugh Engineering and Testing, Inc., Test Report No. T135- 11, dated 02/18/2011, signed and sealed by Daniel G. Farabaugh,P.E. C. CALCULATIONS "Submitted under NOA #13-0604.07" 1. Anchor verification calculations.prepared by Trinity ERD, dated 02/18/2011, signed and sealed by Robert Nieminen,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS "Submitted under NOA #15-0:128.01" 1. Test report on fiber cement physical and mechanical properties per ASTM C1185 and C1186 of GAF WeatherSide Fiber Cement,prepared by Trinity ERD, Test Report No. 30200.01.10,dated 01/08/2010, signed by Robert Nieminen,P.E. 2. Test report on Surface Burning Characteristics per UL 723 of GAF mineral and fiberboards,Test Report No. R19185, dated 10/27/1999,signed by James F. Smith. 3. Test report on Behavior of Materials in a Vertical Tube Furnace per ASTM E136 of GAF exterior wall siding materials, Test Report No. SV18097, Project 10CA32578, dated 07/21/2010, signed by R.K. Laymon. F. STATEMENTS "Submitted under NOA #15-0128.01" 1. Statement letter of code conformance to 2010 and 5t`edition(2014)FBC and no financial interest issued by Trinity ERD, dated 04/10/2015, signed and sealed by Robert Nieminen,P.E. i ' ny t Y Carlos M.threra,P.E. Product Control Examiner NOA No. 18-0327.09 Expiration Date: October 31,2023 Approval Date: May 24,2018 E-1 GAF' NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 2010.G33560CT, titled "GAF WeatherSide Profile 12, Purity Straight, Purity Thatched, Purity Wavy and Profile 9",. sheets 1 through 3 of 3, dated 08/14/2013, with revision 03 dated 01/05/2018, prepared by Nemol etc., signed and sealed by Robert Nieminen, P.E. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to the 6t'Edition(2017)FBC issued by Nemol etc.,dated 01/02/2018, signed and sealed by Robert Nieminen, P.E. Carlos M.Utrera,P.E. Product Control Examiner NOA No. 18-0327.09 Expiration Date: October 31,2023 Approval Date: May 24,2018 E-2 &' NOMINAL . N EMOIetC. DIAMETERI TYP 0+�.o:,In.uu,elnmwtlee„�w 3S3Ox rd,C 0 478 Unkall 1 Oxford,cr o6ae 0 0 0 TEL•201262 9215 FAX 203 262 9241 RING'SHANK .iv YYWW.NEMOETC.COM NAILI TYP I I I I I 1 'P.E R- 1-0 0 0 • I . I .I I I i 0�eN1EM%Nr���,� 13. 1 ?;•vN5 166 0 0 cc o ::W: W r 8 $ a !SS P, ;2: FASTENING PATTERN I '.9o�•F�.oF!�°�a � 0 0 0 0 �'�•.;�S310NP;�.�. 24' W X 12' H WALL SHINGLEI TYP •12 GA 1-3/4' LONG v RING SHANK NAILS D—IngN— PROFILE 12 SIDING I 0 0 0 } 'WATER RESISTIVE BARRIER GAF PER FBC 14042 Weatherside PRODUCT DESCRIPTION �— a 19/32'-PLYWOOD - GAF WEATHERSIDE PROFILE 12 FIBER CEMENT SIDING w FASTENED W/ BD - 24' WIDE X 12' HIGH X 3/16' THICK (NOMINAL) Profile 12 RING SHANK NAILS - TESTED IN ACCORDANCE WITH TAS 202,'2031 AND Elevation&Details o e o o p e 6'. O.C. 8 EDGES MEETING THE REQUIREMENTS OF THE FLOR4DA BUILDING CODE AND INTERMEDIATE - INSTALLED OVER WRB ON.19/32' PLYWOOD FASTENED STUDS, PER FBC• TO WOOD STUDS _ 2322.3(2) - DESIGN PRESSURE RATING = -66,3 PSF - — INSTALLATION NOTES 2X4 WOOD STUDS - ALL INSTALLATION SHALL BE DONE IN ACCORDANCE WITH.THIS 0 0 B 16' O.C. NOTICE OF ACCEPTANCE,THE.MANUFACTURER'S INSTALLATION RECOMMENDATIONS, AND THE REQUIREMENTS OF THE FLORIDA Milt _ BUILDING CODE - WOOD STUD WALL ON WHICH DESCRIBEDI PRODUCT WILL BE Rev DWG File#I Date INSTALLED SHALL BE DESIGNED BY A PROCESSIONAL ENGINEER 03 01.05.18 i OR A LICENSED ARCHITECT PER THE F.B,C;AND THE REQUIREMENTS r OF THIS N.O.A. 02 04.10.15 THE DESCRIBED PRODUCT SHALL BE INSTALLED HORIZONTALLY, 8 •+v COMMENCING'FROM THE BOTTOM COURSE OF 01 09.1 .13 A WALL. GAF Weatherslde 09.1 .1 NOTES Project Name: . 1�' TYP SECTION 3 Weatherslde GAP PRODUCT RENEWED I Campus Drive ELEVATION (:D'� DETAILS as complying with thoFlorida Parsippany,NJ 07054 1 Building Codo 1 1/2'=1'-0' NOA-No. 18-0327.09 973.628.3000 6cpirotlon Dao 10131121123 Sheet: tGE3316OCTrnrduetrol O I a' NOMINAL DIAMETERI TYP e B• .. NEMOIetc. �� e.coxwin,w,rz�Tmxm�.ur�rnrtrtr 3si Christian Street,Unit 013 _ Oxford,CT 06470 TEV 1071629245 00 FAX:20)262 9243 1 WNlW.NEMOETEMOETC.COM 0 0 0 0 • �.�—i —�-_ L r.E Review RING SHANK NAILI TYP 13, 1�, , tpUuutiry . NIEM1N.,�� WALL SHINGLEI FASTENING PATTERN Nnbg s��'•* o o _ o ° TYP SOL/ ' S pTE OF W' — —o— � 12 GA 1-3/4' LONG � ��`'F�OR��P�\=� RING SHANK NAILS PROFILE 9 SIDING 4 t77 ttttttt WATER RESISTIVE BARRIER D-1.1N— ° o 0 o PER FBC 1404.2 19/32' PLYWOOD } FASTENED W/ 8D 1 GAF RING SHANK NAILS PRODUCT DESCRIPTION{ o 0 o o R 6' O.C.'8 EDGES - GAF WEATHERSIDE PROFILE 9 I Weatherside AND INTERMEDIATE '- 32' WIDE X 9' HIGH X 3/16' THICK (NOMINAL) ' STUDS, PER FBC - TESTED IN ACCORDANCE WITH TAS 202, 2031 AND profile 9 2322.3(2) MEETING THE REQUIREMENTS OF THE FLORIDA BUILDING CODE o - INSTALLED OVER WRB ON 19/32' PLYWO D FASTENED Elevation&Details 0 0 0 0 2X4 WOOD STUDS TO WOOD STUDS 16' O.C. - DESIGN PRESSURE RATING = -66.3 PSF• INSTALLATION NOTES, - ALL INSTALLATION SHALL BE DONE IN ACCORDANCE WITH THIS o o o ° NOTICE OF ACCEPTANCE, THE MANUFACTUREg'S INSTALLATION ` RECOMMENDATIONS, AND THE REQUIREMENTS OF THE FLORIDA SECTION BUILDING CODE - WOOD STUD WALL ON WHICH DESCRIBED PRODUCT WILL BE INSTALLED SHALL BE DESIGNED BY A PROF FSSIONAL ENGINEER rRev DWG FIIe# � Date OR A LICENSED ARCHITECT PER THE F.B.C.;AND THE REQUIREMENTS 03 01.05.1 OF THIS N.O.A. _ - THE DESCRIBED PRODUCT SHALL BE INSTALLED HORIZONTALLY, 02 04.10.15 CL COMMENCING FROM THE BOTTOM COURSE OF A WALL F 01 09.16.13 o o 0 o GAF Weathers1d. 081313 ' I — —°— — — NOTES - - 3 Project Name: 18' TYP Weatherside GAF PRODUCT RENEWED I Campus Drive ELEVATION as complying with the Florida Parsippany, 1 DETAILS Buliding Code NJ 07D54 2 NOA-No. 18-0327.09 973.628.3000 Expiration D e 1013712023 �,R 2010.G33560GT Sheet: By o 3 .Of 39 r4lomF-D Product Control 01/05/2016 AS NOTED a- NOMINAL �� DIAMETERI TYP NEMOIetC. 2' " a. 351 Chrirtim 3tmat,Unit p13 Onlord,CT 06470 ' 0 0 0 0 .TEL•101 3629165 N I I I I 1 FAX:203162 9213 RING SHANK WWW.NEMOETC•COM —� NAILI TYP - F.E.Redmv o o o I I I I I — I 1�• - - 1 ' I ,gyp 1<j1E2M....41 %P N S 6 ra- o.• s'l/d 2, Nw — FASTENING PATTERN *I:otif �OF Iz • 4'Q•'•.FLOP,:��.` 0 0 0 0 24' W X 12' H 12 GA 1-3/4' LONG WALL SHINGLE! TYP RING SHANK NAILS — �- PURITY STRAIGHT/ .OrawingWma THATCHED/WAVY SIDING o o 0 0 0. ~ WATER RESISTIVE BARRIER I GAF PER FHC 1404.2' PRODUCT DESCRIPTIOW Weatherside a 19/32' PLYWOOD - GAF WEATHERSIDE PURITY STRAIGHT, PURITY THATCHED, AND FASTENED W/ 8D PURITY WAVY FIBER CEMENT SIDING j RING SHANK NAILS - 24' WI➢E X 12' HIGH X 3/16' THICK (NOMINAL) Purity Straight o 0 0 o ❑ e 6'.O.C. a EDGES - TESTED IN ACCORDANCE WITH TAS 202, 2031 AND Purity Thatched AND INTERMEDIATE MEETING THE REQUIREMENTS OF THE FLORIDA BUILDING CODE Puri Wavy STUDS, PER FBC - INSTALLED OVER WRB ON 19/32' PLYWOOD FASTENED Purity ^ 2322,3(2) TO WOOD STUDS Elevation&Details _ - DESIGN PRESSURE RATING = -66.3 PSF. 2X4 WOOD STUDS INSTALLATION NOTES: o a o e 16. O.C. - ALL INSTALLATION SHALL HE DONE IN ACCORDANCE WITH THIS NOTICE.OF ACCEPTANCE, THE MANUFACTURER'S INSTALLATION AV RECOMMENDATIONS, AND THE REQUIREMENTS OF THE FLORIDA �- BUILDING CODEj ev DWG File# Date - WOOD STUD WALL ON WHICH DESCRIBED PRODUCT WILL BE o. INSTALLED SHALL HE DESIGNED BY A PROFESSIONAL ENGINEER 03 01.05.1 r OR A LICENSED ARCHITECT PER THE F.B.C.IAND THE REQUIREMENTS 0 0' o o OF THIS N.O.A. 02 04.10.15 THE DESCRIBED PRODUCT SHALL BE INSTALLED HORIZONTALLY, 01 •09:18.13 COMMENCING FROM THE BOTTOM COURSE Ori A WALL GAF Weatherslde 081313 - - � - - -�- SECTION NOTES • 1�' TYP $ Project Name: Weathersfde GAF PRODUCT RENEWED I Campus Drive ELEVATI❑N . DETAILS asoomptyIngwiththeFlorida Parsippany,NJ 07054 1 BUltdtng Code 973.628.3000 1/2'=1r-0' NDA-No. 18-0327.09 Fxpiratlon D o 10131!2023 a.vm Sheet 2010.G3356OCT r Mlamf-Dad Product Control 01/05/20162 01 3 AS NOTED