Loading...
HomeMy WebLinkAboutCertification for Design Load Compliance ALL AMERICAN SHUTTERS & GLASS 1638 Donna Ruad, `rbst Palm Beach, FL 3 409 (561) 712-988 . ti%tvA%r.altamericans:hullers.cum Property Information Building Information Owner: WALTER CAMILLA S Wind Zone: 170 MPH. Address: 1868 WILDCAT COVE DR Exposure Category: B FT PIERCE,FL 34949 Minimum Building Dimension: 41 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations 11 Opening Location Device Device Device Max Positive EMax Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 41 79.5 7 29.5 -38.4 2 Int 57 79.5 7 28.8 -31.5 3 Int 41 79.5 7 29.5 -32.2 4 Int 75 99 7 27.8 -30.5 5 Int 48 53 7 30.0 -32.7 6 Int 7 30.0 -32.7 7 Int 48 65 7 29.6 -32.2 8 Int 48 28 7 31.2 -33.8 9 Int 48 53 7 30.0 -32.7 10 End 48 74 7 29.3 -38.1 11 End 48 74 7 29.3 -38.1 12 Int 34.5 74 7 30.0 -32.6 13 Int 48 74 7 29.3 -32.0 14 Int 212 119 7 25.4 -28.0 15 End 163 119 7 25.9 -31.2 16 End 110 119 7 26.7 -32.8 17 Int 27 53 7 31.2 -33.8 18 Int 27 53 7 31.2 -33.8 19 Int 34.5 41 7 31.2 -33.8 20 Int 48 65 7 29.6 -32.2 21 Int 34.5 99 7 29.4 -32.1 22 End 27 41 7 31.2 -41.7 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1