HomeMy WebLinkAboutWind Load Calculation 500 SW 12th Ave
S M .. _ � _T IGHT Deerfleid Beach, FL 33442
WINDO S Fax5569929263662
Property Information F Building Information
Owner: BROWN,MIKE&JUDIE Wind Zone: 170 MPH.
Address: 7410 SANTA ROSA PKWY Exposure Category: C
FORT PIERCE,FL 34951 Minimum Building Dimension: 22 ft.
Mean Roof Height: 16 ft.
At Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 73.75 38.00 7 36.7 -39.9
2 Int 25.50 25.00 7 38.3 -41.6
3 Int 35.88 37.25 7 38.3 -41.6
4 Int 25.50 24.63 7 38.3 -41.6
5 Int 36.00 37.25 7 38.3 -41.6
6 Int 36.00 37.25 7 38.3 -41.6
7 Int 36.00 37.25 7 38.3 -41.6
8 Int 72.88 49.50 7 36.0 -39.3
9 Int 73.13 49.50 7 36.0 -39.3
10 End 73.13 49.50 7 36.0 -46.7
11 Int 73.00 49.50 7 36.0 -39.3
NO
07
G4% -9
County. PC'rrh/(•('ln ;
9
�c
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.