Loading...
HomeMy WebLinkAboutProduct Approval MIAMI MIAMI-DADE COUNTY # PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv CertainTeed Corporation 18 Moores Road ' Malvern,PA 19355 FILE COP SCOPE: 7 -' rn i+ This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Flintlastic Self-Adhered Roofing Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NDA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Floridldfg1lowed by� the expiration date may be displayed in advertising literature. If any portion of the NOAR n it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manuf c r or its rdistrib s and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#15-0108.03 and consists of pages 1 through 19. The submitted documentation was reviewed by Alex Tigera. CODE COMPLIANCE ST. LUCIE COUIT � r � 0 A'QO.: 15-06622.21 MIAM4DADECOUNfY E� Expiration Date: 04/13/20 JAPPROVED1 Approval Date: 08/20/15 Page 1 of 19 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Modified Bitumen Material: SBS Deck Type: Wood Maximum Design Pressure -127.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Spec Description Flintlastic SA NailBase 39 3/8"x 66'6"; Roll ASTM D 4601,Type Fiberglass reinforced, SBS modified weight: 82 lbs. II bitumen base sheet. (2 squares) All Weather/Empire Base 393/8"x 65'10"; ASTM D 4601 Type Asphalt coated, fiberglass reinforced base Sheet Roll weight: 70 lbs. II sheet. (2 squares) UL Type G2 Yosemite Venting Base 393/8"x 32'10"; Roll ASTM D 3909 Mineral Surfaced fiberglass reinforced Sheet weight: 85 lbs. ASTM D 4897,Type buffer sheet. (1 square) II UL Type G3 Flexiglas Base Sheet 39 3/8" x 98'9"; Roll ASTM D 4601,Type Modified Bitumen coated fiberglass base weight: 90 lbs. II sheet. (3 squares) UL Type G2 Flintlastic Poly SMS Base 39'/8"x 64'3"; Roll ASTM D 4601, Modified Bitumen coated polyester base Sheet weight: 90 lbs. Grade S,Type II sheet. (2 squares) UL Type G2 Glasbase Base Sheet 39'/8" x 98'9"; Roll ASTM D 4601 Type Asphalt coated,fiberglass base sheet. weight: 75 lbs. II (3 squares) UL Type G2 Flintlastic Ultra Poly 393/8" x 32' 10"; Roll ASTM D 6164, Smooth surfaced SBS Modified Bitumen SMS Base Sheet weight: 90 lbs. Grade S, Type I Membrane with non-woven polyester mat (1 square) reinforcement for mop applications. Flintlastic SA P1yBase 393/8"x 66'6"; Roll ASTM D 1970 Self-adhering,fiberglass reinforced, SBS weight: 86 lbs. modified bitumen base/ply sheet. (2 squares) Flintlastic SA Mid Ply 393/8"x 32'1"; ASTM D 6163, Self-adhering,polyester reinforced, SBS Roll weight: 62 lbs. Grade S,Type I modified bitumen ply sheet. (1 square) NOA No.: 15-0622.21 MIAMFDADECOUNTY Expiration Date: 04/13/20 APPROVED Approval Date: 08/20/15 Page 2 of 19 I TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE I Product Dimensions Spec Description Flintlastic SA Cap FR 39 3/8"x 32'11"; Roll ASTM D 6163, Self-adhering, fiberglass reinforced, SBS weight: 88 lbs. Grade G,Type I modified bitumen cap sheet. (1 square) Flintlastic SA Cap FR 393/8"x 32'11"; Roll ASTM D 6163, Self-adhering, fiberglass reinforced, SBS CoolStar weight: 90 lbs. Grade G,Type I modified bitumen cap sheet with (1 square) reflective coating. lklintlastic SA Cap 393/8"x 32'l 1"; Roll ASTM D 6164, Self-adhering, polyester reinforced, SBS weight: 95 lbs. Grade G,Type I modified bitumen cap sheet. (1 square) Flintlastic SA Cap 39 3/8"x 32'11"; Roll ASTM D 6164, Self-adhering, polyester reinforced, SBS CoolStar weight: 98 lbs. Grade G,Type I modified bitumen cap sheet with (1 square) reflective coating. FlintPrime Asphalt 1, 3 or 5 gal pail ASTM D 41 Asphalt primer FlintPrime SA 1, 3 or 5 gal pail Proprietary Water-based,polymer modified primer. APPROVED INSULATIONS: TABLE 2 Product Product Description Manufacturer (with current NOA) F1intBoard ISO, F1intBoard ISOx Polyisocyanurate insulation CertainTeed Corp. ACFoam-II Polyisocyanurate insulation Atlas Roofing Corp. ENRGY 3 Polyisocyanurate insulation Johns Manville Corp. H-Shield Polyisocyanurate insulation Hunter Panels, LLC. Multi-Max FA-3 Polyisocyanurate insulation Rmax Operating, LLC. DensDeck, DensDeck Prime Gypsum coverboard Georgia Pacific Gypsum LLC. SECUROCK Gypsum-Fiber Roof Board homogenous fiber reinforced USG Corp. NOA No.: 15-0622.21 togMtu�►neeouN7Y Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 3 of 19 APPROVED FASTENERS: TABLE 3 Fastener Manufacturer Number Product Name Product Description (with current NOA) 1. Dekfast 14 Roofing screw SFS Intec,Inc. 2. Trufast#14 HD Fastener Roofing screw Altenloh, Brinck&Co. U.S., Inc. 3. #14 Roogrip Roofing screw OMG Inc. 4. OMG Heavy Duty Roofing screw OMG Inc. S. FlintFast#14 Fastener Roofing screw CertainTeed Corp. 6. Dekfast 12 Roofing screw SFS Intec,Inc. 7. #12 Standard Roofgrip Insulation fastener OMG,Inc. 8. 3 in. Round Metal Plate 3"round galvalume AZ50 OMG, Inc. steel plate 9. Trufast#12 DP Fastener Roofing screw Altenloh, Brinck&Co. U.S., Inc. 10. FlintFast#12 Fastener Roofing screw CertainTeed Corp. 11. Dekfast Hex Plate hexagonal steel plate SFS Intec,Inc. 12. Flat Bottom Metal Plate 3"square steel plate OMG, Inc. 13. Trufast 3"Metal Insulation 3"round steel plate Altenloh, Brinck&Co. U.S., Inc. Plate 14. FlintFast 3"Metal 3"round steel plate CertainTeed Corp. Insulation Plate CNOA No.: 15-0622.21 MAMIDADECOUNTY AM IFT.W.•Mie Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 4of-19 APPROVED SURFACING/COATING OPTIONS: TABLE 4 . Chosen components must be applied according to manufacturer's application instructions.Any coating,listed below, used as a surfacing, must be listed within a current NOA. System Manufacturer Application Number 1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 300 lbs/sq.,adhered with flood coat of asphalt at 60 lbs/sq. 3. Karnak Corp. Karnak(#97 AF)Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 4. CertainTeed Corp. FlintCoat A-150 applied at an application rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. 6. Gardner Asphalt Corp. APOC#400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 15-0622.21 MI AMbDADECOUNTY Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 5 of 19 EVIDENCE SUBMITTED: Test Asency Test Identifier Description Date Underwriters Laboratories R11656 UL790 Annually Momentum Technologies, Inc. DX08C4A Physical Properties 03/22/04 DX20E3A Physical Properties 03/22/04 Factory Mutual Research 3009610 FM 4450 10/15/01 2D5A9.AM FM 4450 06/22/99 3014751 FM 4450 08/12/03 3014692 FM 4450 08/05/03 3012321 FM 4450 07/29/02 3008869 FM 4470 03/19/01 3037127 FM 4470 01/11/10 3039046 FM 4470 06/15/10 3048520 FM 4470 09/19/13 3025766 FM 4470 11/13/06 Trinity ERD 3518.12.03 TAS 114-F/G/I 12/01/03 C3519.12.03-R1 TAS 114-D/J &TAS 117(B) 04/15/11 03515.07.03-1-R1 TAS 114-J &TAS 117(B) 06/27/12 3521.07.04 TAS 114-J &TAS 117(B) 07/28/04 3522.07.04 TAS 114-D 07/28/04 C31410.06.10 ASTM D 5147/4798 06/03/10 C7290.01.08 ASTM D 4601/1970 01/16/08 C8370.08.08-R1 TAS 114-H/J&TAS 117(13) 10/05/09 C8500SC.I 1.07-R1 ASTM D 6862/TAS 117(B) 08/07/09 C30310.12.09 TAS 114/TAS 117 12/17/09 C10080.09.08-R4 ASTM D 5147/6163/6164 03/25/10 ASTM D 6222/3909 C10080.09.10-R1 ASTMD 5147 &6163 11/18/10 C30560.06.10 TAS 114/TAS 117 06/10/10 C32830.07.10 FM 4470/TAS 114 07/20/10 C32970.09.10 ASTM D 6163 09/16/10 3513.08.02-R1 TAS 114/TAS 117 03/17/11 C32970.04.11 ASTM D 6164 04/01/11 C35500.02.11 TAS 117(13) 02/09/11 C35460.05.11 ASTM D1876 06/16/11 C45620.03.14 ASTM D1876,TAS 114 (H), 03/27/14 FM 4474 C47350.50.14 FM 4470 05/22/14 C44580.07.13 ASTM D 1876, 07/25/13 TAS 114,FM 4474 C42110.08.12 TAS 114& TAS 117 08/13/12 PRI Construction Materials CTC-034-02-01 REV ASTM D 6163 11/24/08 Technologies CTC-032-02-01 ASTM D6163 01/22/08 CTC-066-02-01 ASTM D6163 08/09/11 CTC-070-02-01 ASTM D6222 08/09/11 NOA No.: 15-0622.21 nExpiration Date: 04/13/20 JAPPROYEDI Approval Date: 08/20/15 Page 6 of 19 EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date CTC-093-02-01 ASTM D6164/4798 08/09/11 CTC-122-02-01 ASTM D2178 03/13/12 CTC-123-02-01 ASTM D2178 03/13/12 CTC-127-02-01 ASTM D4601 03/13/12 CTC-128-02-01 ASTM D6163 06/11/12 CTC-129-02-01 ASTM D6163 06/11/12 CTC-132-02-01 ASTM D6164 06/11/12 CTC-162-02-01 ASTM D6164 05/09/13 CTC-161-02-01 ASTM D6164 05/09/13 CTC-183-02-01 ASTM D6162 10/02/13 CTC-190-02-01 ASTM D6164 12/02/13 CTC-199-02-01 ASTM D 1970 01/22/14 NOA No.: 15-0622.21 raarunanecouNrr Expiration Date: 04/13/20 JAPPROVEDI Approval Date: 08/20/15 Page 7 of 19 APPROVED ASSEMBLIES: Membrane Type: APP/SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood, Insulated Deck Description: 19/32"or greater plywood or wood plank. System Type A(1): Anchor sheet mechanically fastened, optional top layer adhered with approved adhesive All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet,Flexiglas Base Sheet,Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c. at the 3" lap and 8" o.c. in three, equally spaced center rows. One or more layers of any of the following insulations. Base insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' H-Shield,FlintBoardH ISO,ACFoam H,FlintBoard ISO,ENRGY 3 or Multi-Max FA-3 Minimum 1.5"thick N/A N/A Top Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/ft' DensDeck,DensDeck Prime Minimum V4"thick N/A N/A Note: Base insulation layer shall be adhered to the anchor sheet with TITESET Roofing Adhesive (3M Polyurethane Foam Insulation Adhesive CR-20), Millennium One Step Foamable Adhesive, OlyBond 500, OlyBond Green, Pliodeck or Insta-Stick spaced 4" o.c. Optional top layer of insulation shall be adhered to the base layer with TITESET Roofing Adhesive (3M Polyurethane Foam Insulation Adhesive CR-20), Millennium One Step Foamable Adhesive,OlyBond 500, OlyBond Green,Pliodeck or Insta-Stick spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Top insulation layer shall be primed with FlintPrime SA at a rate of 0.3 gal/square. Base Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid-Ply,self-adhered. Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -52.5 psf(See General Limitation#7.) NOA No.: 15-0622.21 MIAMbDADECOUNTY Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 8 of 19 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type II: Wood, Insulated Deck Description: 19/32"or greater plywood or wood plank. System Type A(2): Anchor sheet mechanically fastened, optional top layer adhered with approved adhesive All General and System Limitations apply. Anchor Sheet: One ply of All Weather/Empire Base Sheet,Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c. at the 3"lap and 8" o.c. in three,equally spaced center rows. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' H-Shield,F1intBoardx ISO,ACFoam II,FlintBoard ISO,ENRGY 3 or Multi-Max FA-3 Minimum 1.5"thick N/A N/A Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' SECUROCK Gypsum-Fiber Roof Board Minimum V thick N/A N/A Note: Base insulation layer shall be adhered with TITESET Roofing Adhesive(3M Polyurethane Foam Insulation Adhesive CR-20) Millennium One Step Foamable Adhesive, OlyBond 500, OlyBond Green, Pliodeck or Insta- Stick spaced 4"o.c. Top layer of insulation shall be adhered with TITESET Roofing Adhesive(3M Polyurethane Foam Insulation Adhesive CR-20), Millennium One Step Foamable Adhesive, OlyBond 500, OlyBond Green, Pliodeck or Insta-Stick spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply Flint-Prime SA to SECUROCK Gypsum-Fiber Roof Board surface at 0.3 gal/square. Base Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid-Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -60 psf(See General Limitation#7.) NOA No.: 15-0622.21 l�OAMaDADECOUN7Y Expiration Date: 04/13/20 FP ' Approval Date: 08/20/15 Page 9 of 19 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 11: Wood,Insulated Deck Description: Min 19/32"thick or greater plywood or wood plank at max 24"spans attached 6"o.c. using 8d diameter ring shank nails. System Type C(l): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener (Table 3) Density/W FlintBoard ISO,Affoam H,ENRGY 3,Multi-Max FA-3,H-Shield,FlintRoardH ISO Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe DensDeck Minimum 1!411 thick 1,2,3,4,5 1:1.33 ft2 Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply FlintPrime SA to DensDeck surface at 0.3 gal/square. Base Sheet: One or more layer of Flintlastic SA Mid Ply,self-adhered. Ply Sheet: One or more layer of Flintlastic SA Mid Ply,self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap CoolStar self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -45 psf(See General Limitation#7.) NOA No.: 15-0622.21 Expiration Date: 04/13/20 JAPPROVED1 Approval Date: 08/20/15 Page 10 of 19 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type C(2): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' FlintBoard ISO,ACFoam-II,ENRGY 3,Multi-Max FA-3,H-Shield,F1intBoardH ISO Minimum 1.5"thick 6 1:1.45 Note: All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply F1intPrime SA to insulation surface at 0.3 gal/square. Base Sheet: One or more layer of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -60 psf(See General Limitation#7.) NOA No.: 15-0622.21 MIAMFDADECOUNTY Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 11 of 19 t l�k�`'Dese_�phon becl��l: n���/��"�tlucpl mod�atta�hedeu�u�gapprovedk#�gwoodscrewsspace�i 6' o cittzwoodJo�stspac4'oc D��k�2:�Muum fs�"t�itcl��l; goad ached using approved �na�ls spaced 4",q c a wo; foists space�max�mum��4N'�o�` System=s�� _:e�E(�1�1 ases„eet mechauc •_q�fastene��, AIleneralanlSSystem L�im�ttahons�apply eparat�on r heet�. On" oi�moielayes ofGlasbOCRase=S eet�£a�ose'lai ® t A�ch9r�,ase heet;� Qn�tor�irielay�,� Plurtlas'a��SA�1�7ai'1Bas�rmec'IanicaIl�at�chec�as�descnbe�L��lo�! Fastenin r orsr s_`� ' w FB _ _ --r-acB"oc_at e P�1_she ane_oranore _yer�of _ t1a�bc�S��P_y�3�,se�;oz;� c'SA�ArhdYP y,se adheied� Menb�arre �ti�layer�of F�ntlasxic _�--ap F_-�-stu1�,SA Cap;Coo_S,ta�Flmtlast�e SA�Wap�R ,. :.., c sal CaFR ,00 tarse 5 Surfst�in""`•. �An3�aftheTapprove acin� coatti.;n��ttoris _tiin�'f e4>- O`bona !! um�Design �oDeck�; _52�S;psf(3ee�en�___��I�inntahoq=#7�� Pressure: ForDnck3 =6Q QmpsfSee Gen Lunt t�o�#z7) NOANo 1�5=0622 MrarR�necourrrir Egp�rationDate _Q4 3 20f ApprooalDate OS/20/15k Pa e12o�9 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-insulated Deck Description: Minimum 19/32"thick plywood attached using 8d ring shank nails spaced 6"o.c.at wood joists spaced maximum 24"o.c. System Type E(2): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of GlasBase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: Fastened with FBC FI­VHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR or Flintlastic SA Cap FR CoolStar,self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design -52.5 psf(See General Limitation#7.) Pressure: NOA No.: 15-0622.21 1APPROVED1 Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 13 of 19 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24" spans attached 6"o.c. using#8 wood screws. System Type E(3): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6"o.c.at the 3" lap and 6"o.c. in three, equally spaced center rows. Ply Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 75 psf(See General Limitation#7.) NOA No.: 15-0622.21 JAPPROVEFOAMFDADECD 1 1 Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 14 of 19 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c. using#8 wood screws. System Type E(4): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: Anchor sheet shall be fastened with OMG#12 Standard Roofgrip with OMG 3 in.Round Metal Plates spaced 8"o.c. at the 3"lap and 8 o.c. in two, equally spaced center rows. Primer: Apply ASTM D41 primer to stress plates. Ply Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 82.5 psf(See General Limitation#7.) NOA No.: 15-0622.21 MWSOADECOUNTY Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 15 of 19 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-insulated Deck Description: Minimum 19/32" thick plywood attached using#10 wood screws spaced 6"o.c. at wood joists spaced maximum 24"o.c. System Type E(5): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of GlasBase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: OMG 3 in. Round Metal Plates with OMG #14 Heavy Duty fasteners or TruFast 3" Metal Insulation Plate with TruFast#12 DP or TruFast#14 HD Fasteners or FlintFast 3"Insulation Plates with F1intFast#12 or F1intFast 914 Fasteners spaced 6"o.c. at the 4" lap and 6" o.c. in three, equally spaced staggered center rows. Ply Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR or Flintlastic SA Cap FR CoolStar, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -97.5 psf. (See General Limitation#7) NOA No.: 15-0622.21 1APPMIAMIOAROVED1 vTY Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 16 of 19 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c. using#8 wood screws. System Type E(6): Base sheet mechanically fastened All General and System Limitations apply. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4"o.c. at the 3" lap and 4"o.c. in four, equally spaced center rows for a total of five rows. Ply Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid Ply, self-adhered. Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: - 105 psf(See General Limitation#7.) NOA No.: 15-0622.21 evar�naneeouNrtr Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 17 of 19 Membrane Type: SBS MODIFIED, SELF-ADHERING Deck Type 1: Wood,Non-insulated Deck Description: Minimum "/32" thick plywood attached using#10 wood screws spaced 4"o.c. at wood joists spaced maximum 24"o.c. System Type E(7): Base sheet mechanically fastened. All General and System Limitations apply. Separation Sheet: One ply of Glasbase Base Sheet, loose laid. (Optional) Base Sheet: One or more layers of Flintlastic SA NailBase, mechanically attached as described below. Fastening: OMG 3 in. Round Metal Plates with OMG #14 Heavy Duty fasteners or TruFast 3" Metal Insulation Plate with TruFast#12 DP or TruFast#14 ED Fasteners or FlintFast 3"Insulation Plates with FlintFast #12 or #14 Fasteners spaced 6" o.c. at the 4" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sheet: One or more layers of Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. (Optional) Membrane: One layer of Flintlastic SA Cap, Flintlastic SA Cap CoolStar, Flintlastic SA Cap FR or Flintlastic SA Cap FR CoolStar, self-adhered. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) Maximum Design Pressure: -127.5 psf (See General Limitation#7) tNraMEoaoacNOA No.: 15-0622.21 I APPROVEDFM J Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 18 of 19 WOOD DECK SYSTEM LIMITATIONS: I. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8"ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official,a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters,and comers).Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with'the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 15-0622.21 JAPPROVED1 Expiration Date: 04/13/20 Approval Date: 08/20/15 Page 19 of 19