HomeMy WebLinkAboutProduct Approval (2) .t.7 j
MIAM
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) It 805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
CertainTeed Corporation
20 Moores Road
Malvern,PA 19355
t
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:Landmark,Landmark Pro,Landmark Premium,Landmark Impact Resistant,Landmark
Solaris Gold/Platinum and Landmark Pro/Architectural 80
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product-
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 15-0714.19 and consists ofpages 1 through 6. File Copy
The submitted documentation was reviewed by Alex Tigera.
[gAMFDAOECGUNTY
NOA No.: 16-1109.18
•••. , Expiration Date:02/28/22
Approval Date:02/09/17
1 j e 76®
RG lID !f OR
CODE COMPLIANCE
STa LU C
COfu7
OC
v r
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials Dimensional
Deck Tyae: Wood
SCOPE
This acceptance is for CertainTeed Landmark, Landmark Pro, Landmark Premium, Landmark Impact
Resistant and Landmark Solaris Gold/Platinum Shingles as manufactured by CertainTeed Corporation described
in Section 2 of this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Certainteed Landmark A heavy weight,dimensional
dYtanufacturing Locations#1,2,3,4,5,6,7,8,9, 13'/4"x 38'/4" TAS 110 asphalt shingle.
10
Certainteed Landmark Pro A heavy weight,dimensional
Manufacturing Locations#1,3,4,5,6,9 13'/d'x 38%" TAS 110 asphalt shingle.
Certainteed Landmark Premium A heavy weight,dimensional
11anufacturing Locations#1,3,4,5,6,8,9 13'/4"x 38'/4' TAS 110 asphalt shingle.
Certainteed Landmark Impact Resistant A heavy weight,dimensional
Manufacturing Locations#1,7 13'/4'x 38'/4' TAS 110 asphalt shingle.
Certainteed Landmark Pro/Architect 80 A heavy weight,dimensional
Manufacturing Locations#8 13'/4"x 38'/4" TAS 110 asphalt shingle.
Certainteed Landmark Solaris Gold/Platinum A heavy weight,dimensional
Manufacturing Locations#1,8 13'/4'x 38'/4" TAS 110 asphalt shingle.
Accessory Shingles various proprietary Accessory shingles for hip,ridge
and starter strip applications.
NOA No.: 16-1109.18
rtwNwaoECOUNTYM Expiration Date:02/28/22
Approval Date:02/09/17
Page 2 of 6
MANUFACTURING LOCATIONS
1. Peachtree City,GA
2. Ennis,TX
3. Oxford,NC
4. Shakopee,MN
5. Avery(Milan),OH
6. Norwood,MA
7. Shreveport,LA
8. Portland,OR
9. Wilmington,CA
10. Jonesburg,MO.
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Underwriters Laboratories,Inc. R684 UL 790 04/02/01
PRI Asphalt Technologies,Inc. PCTC-01-02-01 TAS 100 01/12/01
CTC-006-02-01 TAS 100 11/12/02
PRI Construction Materials Technologies CTC-092-02-01 TAS 100 02/23/12
CTC-091-02-01 TAS 100 02/21/12
CTC-090-02-01 TAS 100 09/02/11
CTC-087-02-01 TAS 100 07/07/11
CTC-086-02-01 TAS 100 07/07/11
CTC-101-02-01 TAS 100 10/05/11
CTC-102-02-01 TAS 100 10/05/11
CTC-109-02-01 TAS 100 01/18/12
CTC-106-02-01 TAS 100 11/02/11
CTC-105-02-01 TAS 100 10/31/11
CTC-089-02-01 TAS 100 07/18/11
CTC-088-02-01 TAS 100 07/18/11
CTC-213-02-01 TAS 100 05/20/14
CTC-212-02-01 TAS 100 05/21/14
CTC-207-02-01 TAS 100 05/20/14
CTC-206-02-01 TAS 100 05/20/14
CTC-110-02-01 TAS 100 02/13/12
CTC-109-02-01 TAS 100 02/13/12
CTC-288-02-01 TAS 100 09/27/16
Underwriters Laboratories,Inc. 94NK9632 Wind uplift resistance TAS 107 11/30/00
02NK42448 Wind uplift resistance TAS 107 11/08/02
09CA28873 Letter 07/23/09
11CA59020 TAS 107/ASTM D3161 01/25/12
l INK07864 TAS 107/ASTM D3161 09/29/11
07CA26696 TAS 107/ASTM D3161 09/21/07
I ICA38844 TAS 107/ASTM D3161 01/28/12
11CA38844 TAS 107/ASTM D3161 01/27/12
NOA No.: 16-1109.18
rnar�tcaoecounm Expiration Date:02/28/22
Approval Date:02/09/17
Page 3 of 6
Test Ageney Test Identifier Test Narne/Reaart Date
Underwriters Laboratories,Inc. 06CA28237 TAS 107/ASTM D3161 09/22/06
IONK17366 TAS 107/ASTM D3161 0I/04/11
4786334383 TAS 107/ASTM D3161 05/28/14
4786307351 TAS 107/ASTM D316I/ASTM D 3462 05/13/14
1INK08333 ASTM D3462 05/15/12
1 INK08333 ASTM D3462 04/15/12
11NK07864 ASTM D3462 09/29/11
I INK08333/Letter ASTM D3462/UL790 11/05/12
1 INK08333/Letter ASTM D3462/UL790 11/05/12
1 INK08333/Letter ASTM D3462/UL790 11/05/12
12NK13474 ASTM D3462/UL790 05/27/13
4786325932 ASTM D3462/UL790 04/04/14
4787011023 ASTM D 3462 08/01/15
11CA38844 TAS 107/ASTMD3161 01/26/12
06CA02648 TAS 107/ASTM D3161 02/23/06
4787084802 TAS 107/ASTM D3161 03/14/16
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W,attached.
S. Nailing shall be in compliance with Detail'B',attached.
LABELING
1. Shingles shall be labeled with the Miami-Dade Product Control approved seal as seen below or the wording
"Miami-Dade County Product Control Approved".
MIAMWADE COUNTY
rvAr�FonnE NOA No.:16-1109.18
• , Expiration Date:02/28/22
Approval Date:02/09/17
Page 4 of 6
J
r. f
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
DETAIL A
SHINGLE LAYOUT
Rake
Edge 6
5--I
6 314
6
6�
11
6 Ji
11 27 3/4
6 32 3/4
s fila Full Starter
7 Shingle ...
Eaves
LANDMARK,LANDMARK PRO,LANDMARK PREMIUM,LANDMARK IMPACT RESISTANT,
LANDMARK SOLARIS GOLD/PATINUM AND LANDMARK PRO/ARCHITECT 80
NOA No.: 16-1109.18
MIAM4DADECOUNTY Expiration Date:02/28/22
JAPPROVEDI Approval Date:02/09/17
Page 5 of 6
lJ
DETAIL B
38114-
., -Refe_aseTape. .
Nailirrgataafar'Itnri&startdardslapes(frgm 2:12to 21=12
Nailbehveenups)a41ckwerpati lines
./ 12 14 Vii 12" 13114"
moo-
NAIUNG
AkEA CI 7:1J2T
5:V su
ExposureLi . ...... ... ...
LANDMARK,LANDMARK PRO,LANDMARK PREMIUM,LANDMARK IMPACT RESISTANT,
LANDMARK SOLARIS GOLD/PATINUM AND LANDMARK PRO/ARCHITECT 80
(LOW AND STANDARD SLOPE)
Release Tape
Nailing areafor"steep"slopes(greater than 21:12)
Nail between bottom 2 nail Ones.
12" 14 3/4" 12"- 13 1/4"
5 5/8"
6 1/8"
Exposure
7IF 7 7 71
LANDMARK,LANDMARK PRO,LANDMARK PREMIUM,LANDMARK IMPACT RESISTANT,
LANDMARK SOLARIS GOLD/PATINUM AND LANDMARK PRO/ARCHITECT 80
(STEEP SLOPE)
END OF THIS ACCEPTANCE
NOA No.: 16-1109.18
r�wMlnaneeoutvty Expiration Date:02/28/22
JAP R ' Approval Date:02/09/17
Page 6 of 6