HomeMy WebLinkAboutProduct Approval f ' , WOLTERS ENGINEERING ENGINEERING,DRAFTING,CONSULTING 1521197L^Road N West Palm Beach,Ft. 33412 Ph/Fx:(561)225-1982 PRODUCT EVALUATION (FOR HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 500 26 GA. GALVALUME 5V CRIMP 24"WIDE ROOF PANEL (FLPA#27499.17) m — MANUFACTURER: DYNAMIC METALS, LLC l q))- 340 PIKE ROAD FILE COP WEST PALM BEACH, FL 33411 € To all concerned, The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24"Wide Roof Panel, manufactured by Dynamic Metals LLC,is a non-structural galvalume coated Fluropon painted steel roof panel(50 ksi min)that meets the requirements of Sections 1507.4 and 1518.9 of the 6th Edition (2017) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-450-44 and H2686.02- 450-44, and per TAS 110 by PRI Construction Materials Technologies,with results shown in test reports VLS-004- 02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing"5VS-HZ"dated 8/15/19, signed and sealed by Scott Walters, PE. 2. Test Reports listed above by Architectural Testing, Inc.signed and sealed by Vinu Abraham, PE,and by PRI Construction Materials Technologies,signed and sealed by Zachary R Priest, PE. 3, Supplemental Calculations to support"5VS-HZ"drawing,signed and sealed by Scoff Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 24" (nominal) Fastener Spacing across panel: 12" (at Overlaps&Center Rib) Min, Slope: IIItvl oiy HVHZ: 2"112" Zq11 %31 7 Non-HVHZ: Y012"(with Lap Sealant) VIEWE FOR 3712" (no Lap Sealant) CODECO ANCE 5ff-CITZIK'G IN yffl NT5, & Umra'V5 BOCC Field Perimeter&Corner Installation Installation Max. Design Pressure: -117.75 psf -206 psf Fastener Spacing: 4"From Ends, 16"Max. O.C. 4"From Ends,8"Max.O.C. Min Panel Fasteners: #10x1 %'HiLo HWH Screw #10x1 1/2"HiLo HWH Screw with Weather-seal Washer with Weather-seal Washer Fire Barrier: Where required by code, install an approved fire barrier.Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note 42 below) Note: Outside of the HVHZ, 1"round plastic caps may be used to prevent galvanic reactions. Underlay ment: Minimum ASTM D 226 Type II with 4"overlaps and 6"end-laps,anchored with 12 Ga. x 1 '/4"galvanized roof nails with 32 Ga.Tin caps spaced 6" O.C.in rows at the perimeter, at overlaps, and two intermediate rows staggered and spaced 12"O.C. (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ, 1"round plastic caps may be used to prevent galvanic reactions. Minimum Substrate: %2i(15132"min)4-ply CDX Plywood, nailed to 2x rafters spaced 24"max. O.C.with 8d ring-shank nails spaced 4"O.C. Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a pal of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 4. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61 G20.3.005(e),may be used for project specific approval by the local authorities having jurisdiction. 5. All panels shall be permanently labeled with the manfacturer's name and/or logo,and the following statement, "Dynamic Metals FL#27499.17, DM Class 500". '0&046 IN IMrACT Or515TANT CLFUAINWAU 5,%OM- -PON 5, &WINPN/5 Panel Forrririg Theso panels may be jobsite roll formed.with the following Dynamic Metalsmachines, per approval:of 3d party QA provider,to the dimensions shown on Drawing 5VS-HZ 'SSQ=68,40617 SSQ-5150216 SSQ-6814617 $M6690517 =466:061: `SSQ-868.1118 5VC-0490718 5VC=0360516 5VC-0521218 Re-Roofing The - : ;DM Class 500 Series 26 Ga.G.alvalume 5V Crimp 24"`WideRoof Panel Play benstalled over a single,layer of existingasphalt shingles,provide the existing roof meets the requirements of Section 1521 (HVHZ)or'Secfion 1511 (outside of'NVHZ)of the Florida Building Code. if you,have any questions or need more information concerning.this approval please contact me. Thank you, 4� arty yr V. NO` 623.54 f e• o .* Cott;ifyo ers � :�, FL.PE# 62354OF 'o; AUG 18 2tt19. �. -fl'• . �V}d'47i'e I i i • Q I " I'® . Tj 4 _. w � v w ner Za POO ,�e , af e�.