Loading...
HomeMy WebLinkAboutProduct Approval 11/12/2019 Florida Building Code Online BE BCIS Home I Log In I User Registration I Hot Topic I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map I Links I Search Florida E71 pr '� Product Approvala - USER:Public User z " Product Approval Menu>Product or Aoplication Search>Application List Search Criteria Refine Search Code Version 2017 FL# 17022 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL j Application Status ALL Compliance Method ALL _ Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Applications FL# Type Manufacturer Validated By Status FL17022-R7 Revision Extreme Metal Fabricators,LLC Zachary R. Priest, P.E. Approved History Category: Roofing (813)480-3421 Subcategory: Metal Roofing *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: M W ® eC�cak ( .o j'q Mond <<Iivk Credit Card lG Safe FQpa F;t)fIC0 00.C`C �T 130 130 http's://floridabuilding.org/pr/pr app_Ist.aspx 1/1 I Product R- • •rt Manufacturer: Extreme Metal Fabricators, 2160 SW Poma Drive Palm City, FL 34990 ,772.)872-8034. z • . Product Approval # 17022.5 1" Nailstrip Compliant with Florida Building Code 2017 (19h ed.) Compliant with Florida Product Approval Rule #61G20-3 - Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/0.42 specific gravity with 16" Coverage (Max.) { Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.)thru bottom of support. Adhesive/Sealant : Bostik 915TIA Chem-Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel M. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. 4 Install Details: Table A . Allowable Loads METHOD 1. METHOD 2 DESIGN PRESSURE* -86 PSF Main field -97.25 PSF Perimeter FASTENER SPACING 6"O.C. 6" O.C. SEAM ADHESIVE Not required 3/16"continuous bead (see details Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527 UL 580-06& UL 1897-04. TEST REPORT D8133.01-450-18 06/30/15 Specimen#1&#2 QUIVALENCY:UL1897-04 is equivalent to Test Standard UL1897-12. *Deli n:Pressure mar in of safe_ ._.2:1_. ___ _..._ __.._...--.-- . -equivalent_._. - __-_ _. Certificate of Independence: Locke Bowden,P.E.does not have,not will acquire a financial iqj0M!161yq9y company manufacturing or distributing products under this evaluation. ' Locke Bowden,P.E.is not owned,operated,or controlle renyc mq� fan %cturer,or distributing products under this report. • seal STATE OF •. tORIDT I Limitations: 1.Urideriayment to be compliance with current Florida Building Code(FBC)2017 6t'ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 6t'ed.,and per with Manufacturers installation reference. 3.Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method:1-D 4.Engineering analysis for"project specific approval by local authorities wlurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6t'ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty,installation,recommended product use outside of this report. FL 17022.5 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel -Details 16" 1� 3/411 _ Panel Profile 16"o.c. Deck: 15/32"or greater Plywood,or -Wood plank Integral Snap Lock For METHOD 2: Apply 3116"Bead Bostik 915TM Sealant .Continuous Along Male Rib Vertical Flange Fastener #10 x 1"Min. per Table"A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) I ' I FL 17022.5 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel -Details Fastener #10 x 1"Min. perTable'A" Pancake Head Wood Screw 1"Nail Strip Roof Panel f A i.�::st'�riti�c�'ri; �':i,s�;'�ssl,;i��s��Y::vi�'r:•��i,� Sri�v/ Seam Adhesive Application: Deck: For Method 2 -15/32"or greater Plywood, or Apply 3/16"Bead Bostik 915Tm Sealant -Wood plank Continuous Along Male Rib Vertical Flange (Refer to Table"A") Isometric View I I