Loading...
HomeMy WebLinkAboutBuilding Permit Application 1 ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED L9 I O.P7 � to Date: ' Permit Number: CNOV tV� US .2019Building Permit ApplicationPlanning and Development Services Permitting Building and Code Regulation Division 2300 Virginia Avenue,Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial Residential x PERMIT APPLICATION FOR: Roof P ,41 ROPOSED lill/IP'ROVEMENTLOC�TI®N� 3 ° 5`10 � ' �" . :S�.c...bm.. k -.,la a�.,A "� " r . Address: 6010 Yucca Drive, Ft Pierce FL 34982 Legal Description: 6010 Yucca Drive, Indian River Estates-Unit-09 Blk Lot 11 (Map 34/12S)(OR 3292-507) Property Tax ID#: 3402-610-0616-000-7 Lot No.11 Site Plan Name: Block No. 91 Project Name: Judith L Hueter Setbacks Front Back: Right Side: Left Side: DETAILED DE�SCRIIPTION Or0lWA ORIK ,�� 7�'° Remove Existing Shingles from Roof 5/12 Pitch 31 SQ FT Gable Roof Install Poly Stick MTS Underlayment Install 1"Snap Max 26 Ga Galvalume Metal Additional work toe ertormed under this permit—check all appy: HVAC Gas Tank []Gas Piping _Shutters ❑Windows/Doors 11 Electric O Plumbing O Sprinklers Generator Roof 5/12 Roof pitch Total Sq. Ft of Construction: 31 S . Ft.of First Floor: Cost of Construction:$ 22,200.00 UtilitiesSewer Septic Building Height: 13 mPz. +' a*c � N g, .....d L.=, yWNER LE�SSEE � ,�� � - C®NTRCfOR � �..>x m Name Judith L Hueter Name: Joshua Schroeder Address:1341 SE Navajo Company: Marzo Roofing Inc City: Port St Lucie State:FL Address: 861 A-SW Lakehurst Drive Zip Code: 34983 Fax: City: Port St Lucie State.FL Phone No.772-577-0786 Zip Code: 34983 Fax: 772-465-8829 E-Mail: Phone No. 772-871-2489 Fill in fee simple Title Holder on next page(if different E-Mail: marzoroofinginc@gmail.com from the Owner listed above) State or County License: CCC-1331207 If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. IJPPLE,M-E1ti1TA�1:-C43NS`�k� : ,tC3 : ;'- 1JEN LAWK 19fOR'IUNAT-10'19: ESIGNER/ENGINEER: _-,Not:Applicable M916oRYGAGE COMPANY: C\loi:Applicable Name: ddress _ __ _._ Address: ity: St;iatt:e: city:—. iahone^ E SIMPLE TITLE HOLDER: __.. Not=Applicable BONDONG COMPANY: _._.-..-Not Applicable ante: - Name: ddress: Address: City:,______ otic: zip: _ aphone: :ert:ify that no work or inst:allatiori has commenced prior to the issuarice of a permit. .Lucie County makes no representation that:is granting a permit will authorize the permit holder to build the subject:structure ttich N in conflict with any applicable Home•..Owners Association rules,bylaws or and covenant:s that:may restrict or prohibit such ructure.Please consult with your Home Owners Association and review your deed for any restrictions which may apply. consideration of the granting of this reque�ax d permit:,I do hereby agree that t will,in all resp . ts, perform the work accordance with the appr ove(_p, s, the 1 lorid t,Building Codes and St:. Lucie County Ame me its. � r...... is hollowing building perti ation. rt're exem t from undergoing a full concurren revie . room<additi ns, :cessory structures,s mmin€;p ols,fences,wall ,signs,screen rooms and accesso uses to not:her nom `esiden ial use fARMll4NG TO NER: yo IeArre to Re and a Notice of Carxuetnr�aace eat may c aslt tea yezuaya� twice for nproverne .s to your pr petty. Vot:' e of Commencement mu . e recon d and p stied a the jobsite (fare t:h Inst inspect" n. if you int a obtainfinancing, cot east wit re Ie der or an -titian ey before omm -cing work o i ecordingYU r 6�l€at:ic , of Cc�riramE�alceMe ignnature of Ownerjt essc�eJConi:tactor as Agent:for Owner_ S111q, taxi of Contras i:orft,icense!lotder ;TATE OF FLO STATE OF FLORIDA , ......_ 6'irAUNTV 2DF_ 0-1- �%•�` �- — the fQvrfi,Ding inst:ruvrnylt,w.as acknowledge efore me The forgoing instrument was acknowledged before rrre this_!t?`,day oh —dv�-UQim 2t) J)y this I _day of ,]��Ltvl�'L+. __..2() by ;Ns ne of person acknowledging) {Name(Y: rson acknowledging) ---' na we of Nota ­` Scute or'r-lurida) (- gr,at re of Notary Pubii -Si:at:e of Florida} I'e rsurripy known_ OR Produced Identification � — Personally Known..�_OR Produced Identiticabon...-- - Type of Identification Producedype of Ide if o P o c d `, .,. LISA MARIF MON�rr MNl �;.: �'F, LISA M1lRtr MON �}„ Commission No.___..__--_-_------_ —�'A�.`'':=t +tvtr}�Public Sr�tc:ofllorldrs omrnissior fFp�y�� NataryPuhilc:-•Statearrkjvti?l a:i ., omnmissiorr:t GG 1904)! .•r 1,064o is ;•°. r Commixsioer t!coG My c:orirrn.C:xr�irers r°eb 27.'1.022 --- .. Bow(id Glircna,ti IGitYrtsn�itivgtitry Ass : -'�?lig#4th'Nirrr�ug'wYU�c;r"ti57;1'r4tstar s�rti, Revised 07/15/20:1. REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW r>n'rr: COMPLETE INI*I1ALS t 3 Basine�s&Profes"si'061 " ' t g SCIS Home 1 Log In User Regtstratlon i Hot Topica ( Submk Sumbarge Stats 0 Facts ` Fubliettons contact us i SCIS sma map ( Unis ; semen Or aProduct Approval Uscu:Fubltc User ' RECEIVED produmAooturai Menu>product orAegllraVanSearch>AM11caUon Uist>Appucarton DoWl , FL p F1.5259-R28 NOV 12 2019 Application Type Revision Code Version 2017 ST. Lucie County, Permitting Application Status Approved Comments Archived 13 Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 (954)233-1330 Fact 242 malpert@polyglass.com f Authorized Signature Maury Alpert malpert@polygless.co f "OPY Technical Representative Maury Alpert Address/Phone/Email 1111 W.Newport Center Drive Deerfield Beach,FL 33442 Zp# /]'I ��(912)429-8610 ( ( G/ MAlpert@poiygiass.com REVIEWED AIE F r Quality Assurance Representative Arlel Lender CODE COMPLIANCE Address/Phone/Small 1111 W.Newport Center Drive ICI Deerfield Beach,FL 33442 ST. L U 1 E COU (954)233-iZ30 ALender@polpglass.com B O CV.JTY Category Roofing Subcategory Underiayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/13/2021 Validated By John W.Knezevlch,PE Lal Validation Checklist-Hardcopy Received Certificate of Independence FL5259 R28 C0I 2018 01 COT NI MIN N.odf Referenced Standard and Year(of Standard) Standard ear ASTM 01970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSArM April 2012 2012 UL 1897 2012 i Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method'1 Option D Date Submitted 01124/2018 Date Validated 01/29/2018 Date Pending FBC Approval 01/36/2018 Date Approved 04/10/2018 -qummarV of Products FL* Model,Number or Name Description 5259.1 Polyglass Roof Roofing underlayments Underiayments Limits of Use installation instructions Approved for use in HVHx:No FL5259 R28 II 2,018 01 FINAL ER POLYMASS LINDFRLAYMENTS FL5259 Approved for use outside HVHZ:Yes R28,Ddf impact Resistant:N/A Verifled By:Robert Nieminen PE-59166 Design Pressure:+N/A1-622-5 Created by Independent Third Party:Yes Other.1.)The design pressure In this Evaluation Reports application relates to one particular ELS259 R28 AE 2018 01 FINAL ER POLYGL.ASS UNDERLAYMENTS FL5259- underlayment system(over concrete deck) B28,odf for use under foam-on tile systems(where Created by Independent Third Party:Yes the underlayment forms part of the load- path).Refer to ER Section 5.6.4 f r.other systems,other deck types and associated maximum design pressures.2.)Refer to ER Section 5 for other limits of use, XQ Nant Contact Us::2601 Blair stone Road Tallahas—FL 3'2399 Phone:850-487-11324 The state of Florlda Is an AvUEO employer.Copyright 2007-2n19 Date of Elorida.::Private Statemenit:Arcesslbli._, M Stat me"t::Rerund statomen Under Florida law,email addressee ate public records-IfVou do not want yours-muff address Mamma In response m a pubtiMeconts request,do nut send electronic mall to this malty.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-pursuant to Section 455.275(1), Rodda Statutes,effective October 1,2012,kansees licensed under Chapter 455,F.S.must provide the Department with an email address Nthey Gaya one.The emalts provided may he used for official communication with the Hammes.Howover email addresses are public record.If you do not wish to supply a.personal address,please ptmdde the Department with an email address which we be made avallable to the pubUa To determine If you are a licensee under Chapter 455,F.S.,please cildt,e!, pp�r�Product Apppmml Accepta I1®®OR® Credit Card Safe MEMO j etc. CerUftcate ofAutilorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)252-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Poiyglass USA,inc. Evaluation Report P12060.02.09-R24 1111 West Newport Center Drive FL5259-R28 Deerfield Beach,FL 33442 Date of Issuance:02/24/2009 (954)233-1230 Revision 24:01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the-applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nleminen,P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6s' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the productis), the Quality Assurance or the production facility Iodation(s). NEMOEetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The ,Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it"shall be done in its entirety. ' INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: s',rSm,,,,.f— ��..t Robert J.M.Nieminen,P.E. :sa- r w "�.i,,•.•• The bcsimileseal appearingwas authorized byRobert Nieminen, Florida Registration No.59166,Florida DCA ANE1983 P.E,on 01/24/201&This does not serve as an electrontcaily p signed dowment' CERTIFICATION OF INDEPENDENCE: 1. NEMO{etc.does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOI etc.Is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for . which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest In any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO]etc.nor Robert Nieminen,P.E.are,In any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,Is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING COMPONENT EVALUATioN: 1. SCOPE: Product Category: Roofing Sub-Category: Underiayment Compliance Statement: Roof Underlayrnents, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the&Edition(2017)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the installation Requirements and limitations J Conditions of Use set forth herein. 2. STANDARDS: Section Prove Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3/1507.1.1 Physical Properties ASPM D226 2009 1507.2.4 1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FR5A/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entkv Examination Reference Date FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000 PRI CW5878) Physical Properties PR101111 04/08/2002 PRI(TST 5878) Physical Properties PUSA005-02-01 01/31/2002 PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI(MT 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI(TST S878) Physical Properties PUSA-013-02-03 12/23/2002 PRI(rST5878) Physical Properties PUSA-018=02-01 07/14/2003 PRi(TST5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI CM 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI(TST 5878) Physical Properties PUSA 035-02-01 09/29/2006 PRi(15T 5878) Physical Properties PUSA-055-02-02 12/70/2007 PRI(TST 5978) Physical Properties PUSA-061-02-02 01/28/2008 PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI(TST5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI(TST2508) Physical Properties JX20117A 04/01/2008 MTI(TST 2508) Physical Properties RX14E8A 01/29/2009 ERD(ST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD CTST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(T5T 6049) Physical Properties 02200.07.03 07/14/2003 ERD(TST 6049) Wind Uplift P1740.OL07 01/04/2007 ERD(TST 6049) Physical Properties P5110.04A7-1 04/11/2007 ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD(TST 6049) Physical Properties .P13450.08.09 08/13/2009 ERD(TST6049) Wind Uplift P3OS40.11.09-R1 11/30/2009 ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD(TST 6049) Wind Uplift P12030.22.09-2 11/30/2009 ERD(TST6049) Physical Properties P11030.11.09-3 11/30/2009 ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD(T$T 6049) Physical Properties P33370.04.11 04/26/2011 ERD CTST 6049) Physical Properties P37300.10.11 10/19/2011 MEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Cert WOW ofAuthprimtion#32465. 6TM EDITION(2017)FBC NON.HVH2 EVALUATION FL52594128 Polyglass Roof Underiaymentr,(954)233-1.230 Revision 24:01/24/2018 Page 2 of 14 OMEMO letc. Entity Examination Reference Date ERD(W-6049) Physical Properties P40390.08.12-1 08/06/2012 ERD(M 6049) Physical Properties P40390.08.12-2 08/U7/2012 ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD(TST 6049) Wind Uplift P1738,02.07-R2 04/29/2013 ERD(TST 6049) Wind Uplift 31757.04.01-1-RI 04/3012013 ERD(M 6049) Wind Uplift P41630.08m 08/06/2013 ERD(TST 6049) Wind Uplift P11751.05.03-RI 11/26/2013 ERD(TST 6049) Wind Uplift PU781.I1.03-RI 11126/2013 ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD(M 6049) Physical Properties 6020.09.24-2 09/09/2014 ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD(W 6049) Physical Properties 6020.09.'14-6 09/08/2014 ERD(TST 6049) Physical Properties P46520.10.24 10/03/2014 ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD(TST 6049) Physical Properties PLYri-SC7550.03.25 03/24/2025 ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD(TST 6049) Physical Properties P44360.10.14-RI 05/18/2015 ERD CM 6049) Physical Properties PLYG-SC8080.05.15-2 05/20/2015 ERD(W 6049) Wind Uplift PLYCi-SC8905.05.16-:1 05/27/2016 ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/26/2016 ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD(TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 ERD CW 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD tW 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 IMES(EVL 2396) IBC Compliance ESR-1697 11/01/2024 Miami-Dade(CER 1592) tiVHZ Compliance NOA 14-0717.08 01P212015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA PA Affidavit Mule-Hide Cress Ltg 03/01/2008 Polyglass USA Materials Affidavit PolVsfick SA Compound 08/18/2011 UL,I.I.C.(QUA9625) Quality Control Service Confirmation Exp.3.0/0512018 4. PRODUCT DESCRIPTION: Oil di Ily Fa 4,1.2 Elastobase.Is a fiberglass reinforced,SBS modified bitumen base sheet. 4.12 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet. 4.1.3 Polyglass 62 Base Is a fiberglass-reinforced,asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet 4.2.1 Polystick MTS or Pollystick KFS PLUS Is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,surfaced with polyolefinic film surface;meets FRSA/TRI April 2012. 4.2.12 Polystlick IR-Xe is a nominal 60-mit thick rubberized asphalt waterproofing membrane,glass fiber reinforced,With an aggregate surface;meets ASTM D1970. 4.2.3 POIVstIck TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a polyester fabric surface;meets ASTM D1970 and FRSA/TRI April 2012. NEMO Em LLc. Evaluation Report P12060.02.09-R24 CerUjitute OfAUtharboVon#32455 5m EDITION(2017)F8C NON-HVHZ EVALUATION 85259-R28 Polyglass Roof UndeflaVirienlis,(9541233-1230 Revision 24:01/24/2M8 Page 3 of 14 ONEMOletc. 4.2.4 Polystick TU P Is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester• reinforced,with a granular surface;meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface;meets ASTM D1970 and FRSAJTRi April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Gap Sheet and Mute-Hide SA APP Cap Sheet(FR)are polyester . reinforced,APP modified bitumen cap sheets;meet FRSA/TRl April 2012. 4.2.7 Polystick Dual Proem Is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970. 4.2.8 Polystick Tiie Pro"" Is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and FRSA/TRl April 2012. 4.2.9 Polystick MU-X is a nominal 54-mi) thick-dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polypropylene film surface;meets AC188 and physical requirements of ASTM D1970(See Section 5.8). Mac hanicalty'Fasteried and/or onded•llgd'e"ilayments 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand-surfaced SBS modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an alternate to"Mineral Surface Roil Roofing" (ASTM D6380, Class M)in the "Single Ply System"from FRSAjrR1 April 2012 (04-12)beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the'Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered file roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets,meet ASTM D6164. Elastoflex S6 6 and Elastoflex S6 G FR are for use as an alternate to"Mineral Surface Roll Roofing" (ASTM D6380, Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened file roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied"Cap Sheet"in the`Two Ply System"from FRSAtTRI April 2012(0412)beneath mechanically fastened or adhered file roof systems. Elastoflex S6 G FR Is for use as an alternate to Hot Asphalt applied "Cap.Sheet" in the 'Two Ply System"from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyfiex G is for use as an alternate to Heat Applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012 (0442)beneath mechanically fastened or adhered file roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened tile roof systems. S. I.imffmONS: 5.1 This is a building code evaluation. Neither MEMOIetc. nor Robert Nieminen, P.E.are,In any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report Is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 55.4 Polyglass Roof Underlayments may be used with any'prepared roof cover where the product Is specifically referenced within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 CerllfxWe afAuthor&ation#3wss 6H EDITION(2017)FBC NON-HVHZ EVAU;AMON F15259-R28 Patygfass Roof Underiayments;(954)233-1230 Revision 24:01/2412018 i Page 4 of 14 OMEMO J etc. 5.5 Allowable Roof Covers: e< $LtcS.fCt7oFGOVEEiA�:�ONS. '0 Underlayment AsphaltShingles Nall-On Tile Foam-OnTile Metal Wood shakes slate a shingles Elastobase yes Yes Yes Yes Yes Yes {BaseS.heetin2-p1y_W9em) leasasheettn2-ply5ystem) Elastobase P yes Yes Yes Yes Yes Yes (Bases1eet1n2-ptysystem) (a9se5heet1n2-plysystem) Polygiass62Base No Yes Yes No No No (BaseSheet1n2-p1yspwm) (8asnsheetTn2-piysystem) PolyglassAPP Base No Yes Yes No No No (aUesheet1n2-P1y SPam) (Bese sheettn 2-ply system) Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes PotystTck IR-Xe Yes No No No Yes Yes Polystick TUP. No Yes Yes(See 5.5.1) NO No No Polystick TU Plus Yes Yes Yes(See 5.5.1) Yes Yes Yes Polystick TU Max No Yes' Yes(See 5.5.2) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes(See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes(See 5.5.1) No Yes Yes Elastoflex S6 G FR - Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes(See 5.5.1), No Yes Yes Polyflex G Yes Yes Yes(See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes(See 55.1) No Yes Yes Mule-Hide SA-APP Cap Sheet Yes yes Yes(See 55.1) No Yes Yes or SA-APP Cap Sheet(FR) 5.5.1 "Foam-On Tile"is limited to use of the following Approved the adhesives/underlayment combinations. 3AtsoiNic7itr i4oiPstvr/llt4�4iii(aiiMT�Ctiiilget+l�rri' Adhesive Florida Product Approval Underlayments DAP Foam Touch`n Seal StormBond Roof F114506 Polystick TU Plus,Polystick TU Max Tile Adhesive Dow TilellondTM FL22525 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro. Polystick TU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro, ICP Adhesives,PolysetO AH-160 FL6332 Elastoflex G TU,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mute-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Polystick TU P,Polystick TU Plus,Polystick TU Max;Polystick Tile Pro, ICP Adhesives Polyset:0 RTA-1 FL6276 Elastoflex G TU,Elastoflex SG G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR, Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR) Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval far Overturning Moment Resistance Performance. NEMO ETC,LLC. Evaluation Report P12060.02.09-1124 Certl Cao afAUM0fizat/an 037455 6m EDITION(2017)FITC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlaymentsi(954)233-1230 Revision 24:01/24/2018 Page 5 of 14 ONEMOleft. 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Polystick(all variations),Dual Pro,Tile Pro,Polyflex SAP or SAP FR,Mule-Hide SA APP Cap Sheet or SA-APP Cap Sheet (FR)self-adhered to: ➢ New untreated plywood;ASTM D41 primed new untreated plywood;Existing plywood;ASTM D41 primed existing plywood, New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods `ZIP System" Panels (designed and installed to meet wind loads for project). Note.Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch-applied to: A ASTM D41 primed structural concrete. 5.6.2 Bond to-Insulation: Polystick(all variations),Polyflex SAP or SAP FR,Mule-Hide SA APP Cap Sheet or SA APP Cap Sheet(FR)self-adhered to: 9 ASTM C1289, Type Il, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board. Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. Polyflex G or Polyflex G FR torch-applied to: A ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering mandfacturees Product Approval. For installations under foam-on tile systems,insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underiayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanicaliv Attached Base Laver: Polystick(all variations), Polyflex SAP or SAP FR,Mule-Hide SA ARP Cap Sheet or SA-APP Cap Sheet(FR)Dual Pro or Tile Pro self-adhered to. D ASTM D226,Type I or If felt,Elastobase;Elastobase P or Mule-Hide Nail Base. Elastoflex G TU,Elastoflex S6 G or Elastoflex S5 G FR in hot asphalt to: A ASTM D226,Type I or II felt;Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch-applied to: D Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For Installations under foam-on tile systems, base layer shall be attached per minimum requirements of FRSAf TRI April 2012(04-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein,or as tested in accordance with FBC Section 1504.3.1. MEMO M LLC. Evaluation Report P12050.02.0"24 Cert[Rcote ofAutharhown#92455 61N EDITION(2017)FBC NON-HVH2 EVALUATION FL5259-R28 Polyglass Roof Underlaymerib;(954)233-1730 Revision 24:01/24/2018 Page 5 of 14 OMEMO etc, 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on file applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).Refer to FRSA/TRl April 2012(04- 12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Desien Pressure=-90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Potystick.TUMax,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA APP Cap Sheet(FR),self-adhered. #2 Maximum Design Pressure=-97 5 nsf: Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1K"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-105 Psf• Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-AAP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1/"."ring shank nails through 32 ga.,1-5/9"diameter tin caps spaced 12-Inch o.c. #4 Maximum Design Pressure=-135 Pd. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Joints: Min.4-inch wide strips of Elastoftex SAV over all plywood joints. Underlayment:Polystick TU P.Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #5 Maximum Design Pressure=-315 Dsf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:,Polystick TU P,Polystick TU Plus,Polystick TU Max,The Pro,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #6 Maximum Design Pressure=-622.5 Dsf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer. PG100orASTM D42 Underlayment:Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #7 Maximum Design Pressure=-30.0 asf*: Deck: MIn.15/32 inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: 'Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga,x 1:25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-Inch o.c.at the 3-inch wide side laps and 6-41nch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. MEMO ETC,U.C. Evaluation Report P12060.02.09-M CertJlcate oj'quthorlaWan&32455 Gr EDITION(2017)FBC NON-HVHZ EVALUATION FLW39-R28 Potyglass Roof Underlaymeets,(954)233-1230 Revision 24:01/24/2MB Page 7 of 14 NNEMO etc. #8 Maximum Design Pressure=-37.5 psf*: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 34nch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #9 Maximum Design Pressure=-37.5 psf*: Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)or two(2)layers ASTM D226,Type 11 felt Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G.applied in full mopping of hot asphalt #10 Maximum Design Pressure;=-45 psf*: Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One(1)layer ASTM D226,Type II felt Fasteners: 11 ga.x 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the 2-inch wide side laps and 44nch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-ad hering undedayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt #11 Maximum Design Pressure=-45 Pse: Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. . Base Sheet: Two(2)layers ASTM D226,Type 11 felt Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows. Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Pius,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU or Elastoflex S6 G,applied in full mapping of hat asphalt #12 Maximum Design Pressure=-45 psf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 184nch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #13 Maximum Design Pressure=-52.5 psf Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MARX Cap Fasteners Spacing: 9-inch o.c,at the 2-inch wide side laps and 12-inch o.c,at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #14 Maximum Design Pressure=-525 P Deck: Min.15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nall Base(poly-film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. NEMO ETC,LLC. Evaluation Report P12060.02.09-1124 Cerowte ofAatharimtian#32455 6r"EDITION(2017)FBC NON-HVH2 EVALUATION F1 41 Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 8 of 14 ONEMOletc. #15 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly film surface for torch-applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastaflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #16 Maximum Design Pressure=-60 psf: Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hat-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #17 Maximum Design Pressure=-60 asf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: CMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates Spacing: 12-inch o.c.atthe+Inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastofiex S6 G.applied in full mopping of hot asphalt or Polyflex G,torch-applied. #18 Maximum Design Pressure=-67.5 psf Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 8-inch o.c.at the flinch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mapping of hot asphalt or torch-applied or Polyflex G,torch- applied. #19 Maximum Design Pressure=-75 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MARX Cap Fasteners Spacing: 10-inch o.c.atthe 4-inch wide side laps and 10-inch o.c.atthree(3)equally spaced staggered center rows. Underlayment Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch- applied. #20 Maximum Design Pressure=-90 Dst Deck: Min,15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MARX Cap Fasteners Spacing: 64nch o.c.atthe 2-inch wide side laps and 6 inch o.c.at two(2)equally spaced staggered center rows. Underlayment:Elastaflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #21 Maximum Design Pressure=-90 Dsf: Deck: Min,15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hat-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment.•Elastoflex G TU or Elastaflex S6 G,applied in full mopping of hot asphalt or Polyflex G.torch-applied. #22 Maximum Design Pressure=-90 asf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Spacing: 64nch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt NEMO ETC,LLC. Evaluation Report P32060.02.09-R24 Certificate ofAuHtotimBon#32455 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FLS259-R28 Polyglass Roof Underlayments,(954)233-1130 Revision 24-.01124/2018 Page 9 of 14 OMEMO etc. #23 Maximum Design Pressure=-90 ruff Deck: Min.15132-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch-applied underlayment) Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 94nch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mapping of hot asphalt or torch-applied or Polyflex G,torch- applied. #24 Maximum Design Pressure=-97.5 asf: Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-Inch x 3%8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c.at the flinch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows. Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered. Underlayment:Palystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #25 Maximum Design Pressure=-105 asf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. #26 Maximum Design Pressure=-112.5 osf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-Inch o.c.at the flinch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin-caps Base Ply: Polystick MTS or Polystick MTS PLUS,self-adhered Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered. #27 Maximum Design Pressure=-120 osf: Deck: Min.15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap) Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied In full mopping of hot asphalt or Polyflex G,torch-applied. #28 Maximum Design Pressure=-120 psf Deck: Min.15/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase(sanded top surface) Fasteners: Trufast#12 DP orTrufast#24 HD with Trufast 3"Metal Insulation Plates Spacing. 6-inch o.c.at the flinch wide side laps and 64nch o.c.at five(5)equally spaced staggered center rows. Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. 5.6.4.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on the systems carry a Maximum Design Pressure of-45 psf. NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Certifkate ofAutharlrallan#32455 6P EDITION(2017)FOC NON-HvHZ EVALUATION FL5259-R28 Polyglass Roof Underiayments;(954)233-1230 Revision 24:01/24/2018 Page 10 of 14 ONEMOletc. 5.6.4.2 For mechanically attached Base Sheet,the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(0412),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zane 1 design pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk's carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after Installation. Polystick MTS, MTS PLUS,TU P,TU Plus,TU Max, Dual Pro,Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile,in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which rase the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition,tested at standard laboratory conditions. Agreement between purchaser and seller,as set forth In Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance. 5.9 Tile Slippage Limitations(FRSA/TRI April 2012(04-121): When loading roof tiles on the•underlayment in direct-deck file assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. •.E/iBLi7:TILE.SLIPFA6E+i1:IM17ATiGNSFA,If3D�R�4'L,;,i�EGKTtE�NtI'J�770NS. :i. Underlayment Tile Profile Staging Method Maximum Slope Flat 10-tile stack 7:12 Elastoflex G TU Lugged 8-tile stack(6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Flat 6-tile stack(4 over 2) 5:12 Polystick MTS or MTS PLUS Lugged 6-tile stack(4 over 2) 4:12 Polystick Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat 6-tile stack(4 over 2)or 10-tile stack 7:12 Polystick TU Max Lugged 6-file stack(4 over 2) 7:12 Lugged 10 the stack 6:12 Flat 6-tile stack(4 over 2) 6:12 Polystick TU P Lugg 6-tile stack(4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12 NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 y GudflmteofAutharaWn#32455 6TMWITION12017)F13CNON-HVHZEVALUATION FL5259-R2& Polygiass Roof Underlayments,(954)293-1230 Revision 24"01/24/2018 Page li of 14 ONEMOjetc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall•be installed in accordance with PolyglasS published installation requirements subject to the limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6:3 Elastobase`;Elasto�ae P:4iiMule=Hide Nallbasie:.: 6.3.1 Non-Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226,Type 11 underiayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase,Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick,Polyflex SAP,Polyflex SA P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex 6 TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are those associated with the top-layer underiayment,as set forth in Table 1. 6.3.2 Tile Applications: Elastobase,Elastobase P or Mule-Hide Nail Base are limited to use as a mechanically attached base sheet in the"Two Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 and Section 5.6.4 herein,coupled with FRSA/TRI April 2012(0412)Installation Manual. 6.4< POW.tete(IIjTS?MTSPLtFS;I ]( ,. r r ,, a Pro �t`e PaQr ItAU-. oK PoiyflexSAP,PoCyflei(•SAP FR t t�XUP'T.tJ`P.l.. TlfM Du. (.f, ...%.: _. _. � TJX I ♦,` >! Mule-Hide S?a7,AF OP.i to Mu SA;APR;C.ap:Sli�et<(#?�t),';:;•::' '�:_}` .a. 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970(except Polystick TU P)underiayment In FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers: All self-adhering materials,with the exception of Polystick TU Plus,Polyflex SAP or SAP FR and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule- Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-type metal cap nail,at a minimum rate of 12"o.c. Polystick TU Plus should be back- nailed using the above noted fasteners and spacing, in area marked "nail area, area para claver' on the face of membrane. The head lap membrane is to cover the area being back-nailed. All seal4ap seams (selvage laps) must be firmly rolled with a minimum 28 Ib. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro,align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). view of ovelap seam of vual Pro and Tile Pro All over-fabric and over-granule end-taps shall have a 6-inch wide, uniform layer of Polypius 50 Premium Modred Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus,,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys, or exposed roof to wall details NEMO ETC,LLC. Evaluation Report P12050.02.09-R24 CertljkateofAuthadmUon#32455 6 EDMON(2017)FBcNON-HVHZEVALUATION F1.5259-R28 Pelyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018 Page 12 of 14 ONEMO I etc. Repair of Polystick membranes is to be accomplished by applying.Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass P6500 Modified Cement to the area in need of repair,followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be Installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted-roller or,on steep slopes,use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 Ib roller)or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications(not allowed forPolystkk Dual P%IR Xe or Polystick MUX): Reference is made to FRSA%TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened file roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s),Base Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1. For adhesive-set the applications,refer to Section 5.6A herein. 6.4.4 Two(2)Ply Underlayment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P,TU Plus,TU Max,Tile Pro or Polyflex SAP is allowable for use under foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. .a is ;fi.'S'. alto ex1"seofl. � 1:i: stof(Oic_ 6.5.1 Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be installed In compliance with current Polyglass published Installation requirements. For use in file applications: ✓ Elastoflex 6 TU is for use as an alternate to"Mineral Surface Roil Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012 (04-12)beneath mechanically fastened the roof systems or the Hot Asphalt applied"Cap Sheet"in the`Two Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or adhered the roof systems. ✓ Elastoflex S6 6 FR is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in the"Single Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened tile roof systems or the Hot Asphalt applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened tile roof systems. 6.5.2 For hot-asphalt-applications,Elastoflex G TU,FJastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-Inch wide, off-set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. •'OLP6eX G".F 6.6.1 Polyflex G or Polyflex 6 FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet"in the`Two Ply System"from FRSA/iR1 April 2012(04-12)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied"Cap-Sheet"In the"Two Ply System"from FRSA/TRI April 2012(0412)beneath mechanically fastened tile roof systems(Base Sheet Limited per 5.6.3). NEMO ETC,LLC. Evaluation Report P12060.02.09-R24 Cer 4kate ofAoNortmtwn#32455 6T"EDITION(7037)FBC NON.HVH2 EVALUATION FL5259-R28 Poiygiass Roof Underlaymenb,(954)233-3230 Revision 24:01/24/2018 Page 13 of 14 E ' OMEMO(etc. 6.6.2 Polyflex 6 or Polyflex G FR shall be fully torch-applied to the substrates noted in Section S.G. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide,off-set minimum 3 feet from course to course. Side and end laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. E.7 Tile Stanine: 6.7.1 Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. Refer to Table 2 herein,and Polyglass published requirements for the staging. 6.7.2 Battens and/or Counter-battens,as required by the the manufacturer and FRSA/TRI April 2032(0412)must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail- boards,to prevent tale sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-eight(48)hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C.61620-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. 90 in�.:..;<:�:;�:.ti:�`::�: _ Femley,NV,Hazleton,PA&Winter Haven,FL ASTM D1970 Polystick MU-X Hazleton,PA M-D 13-0004. Elastoflex G TU ASTM D1970 Polystick IR-Xe Hazleton,PA&Winter Haven,FL ASTM D1970&FRSA/TRI April 2012 Polystick TU Plus ASTM D1970&FRSA/TRI April 2012 Polystick TU Max Tuscaloosa,AL ASTM D4601,Type II Polyglass G2 Base ASTM D226(physicals) Elastobase,Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS,Polystick MTS PLUS FRSA/TRI April 2012 PolystickTU P Winter Haven,FL FRSA/TRI Apr112012 Polyflex SAP,Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970&FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6,Elastoflex S6 G FR ASTM D6222 Polyflex G,Po I IexG FR 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- NEMO ETC,ILC. Evaluation Report P12060.02.09-R24 Cern/(cote ofAutharizotran#32455 a EDITION(2017)FEC NON-HVH2 EVALUATION FL52594US Polyglass Roof Underlayments,(954)233-1230 Revision 24:01/24/2018 Page 14 of 14 ,Product Report Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL 34990 772.)87240.34. !Florida Product Approval # 17022.5 1" • { Compliant with Florida Building Code 2017 (61h ed.) RECEIVED i Compliant with Florida Product Approval Rule#61G20-3 Compliant: Keystone Certifications NOV 12 2019 ST. Lucie County., Permitting i Product: l"Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength:50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/0.42 specific gravity with 16"Coverage(Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 penetrate 3' , 6 mm. hru . Fastener 1:#10 x 1 (min.) Pancake Head Wood Screw to p ( ) Py bottom of support. Adhesive/Sealant : Bostik 915 " Chem-Chalk one component,polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each anel seam. € EVIEWE� FOR Underlayment:To be compliant with FBC Sec 1507.1.1 com COMPLMNCE . ST. LUCE- COUNTY Slope:Shall be in compliance with FBC Sec. 1507. BOCC Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* -86 PSF Main field -97.25 PSF Perimeter FASTENER SPACING 6"O.C. 6" O.C. SEAM ADHESIVE Not required 3/16"continuous bead _ ......,.__....:_,__._. .... ...... ....(see details) Reference Data: ARCHITECTURAL TESTING,INC.TST ID#: 1527 UL 580-06&UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen#1&#2 EQUIVALENCY:UL1897-04 is equivalent to Test Standard UL1897--12. *Design Pressure mar in of safe 2:1 Certificate of Independence: Locke Bowden,P.E.does not have,not will acquire a financial ipfresten qqy�company manufacturing or distributing products under this evaluation. .• L Bey �y Locke Bowden,P.E.is not owned,operated,or controlle{ v y.II R#- �1in durer,or distributing products under this report. 1 7- �V% • X • • seal ��•• STATE OF ;?Gj 0. 0" ID. NAI.t rf`r•�� Limitations: 1.Underlayment to be compliance with current Florida Building Code(FBC)2017 60,ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 6t'ed.,and per with Manufacturer's installation reference. 3.Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method:l-D 4.Engineering analysis for°project specific approval by local authorities wfjudsdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6°i ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty,installation,recommended product use outside of this report. FL 17022.6 1.0 Nail Strip(26GA Steel),16"Wide Roof Panel-Details 16, 3/4,1 Panel Profile .00 16" o.c. Deck: -15/32"or greater Plywood, -Wood plank Integral Snap Lock For METHOD 2: Apply 3116"Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1"Min. perTable"A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) FL 17022.5 1.0 Nail Strip(26GA Steel),16"Wide Roof Panel-Details Fastener #10 x 1"Min. per Table"A" Pancake Head Wood Screw 1"Nail Strip Roof Panel .��i�.�c c diu�a•:�v'�:. •:� :'�+':�s .'.iso 'ii .v:�, Seam Adhesive Application: Deck: For Method 2 15/32"or greater Plywood,or Apply 3/16"Bead Bostik 91511 Sealant -Wood plank Continuous Along Male Rib Vertical Flange (Refer to Table"A') Isometric View