HomeMy WebLinkAboutProduct Approval � T
i�itiay'S�t'Gi�p�;�>$r � �f� •; - ,� 11 ���...,
BQS Home 1 log In User Registration ; Hot Topics Submit Surcharge j Stats&Facts j Publications Contact Us SCIS site Map j Links j Search
Florida
Product Approval
t• (' • USER:Public User
Product Approval Menu>Product or Application Search>Appfication List>Application Detail
FL# FL17022-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments 08/18/2017v.date reapply 08/21/17
Archived El
Product Manufacturer Extreme Metal Fabricators,LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
flvalldation@yahoo.com ,
Authorized Signature Richard McKuhen
' flvalidation@yahoo.com �® ✓ �`
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive REVIEWED
p�p��
Palm City,FL 34990 RE Ff IE�C9 E® F®
richa 872-8034 CODE COMPLIANCE
richard@emfab.net
Quality Assurance Representative ST. LUCIE COUNTY
Address/Phone/Email B®CC
Category Roofing
Subcategory Metal Roofing /
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
El Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R.Priest,P.E.
Z Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
T
1
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
SummarV of Products
FL# Model,Number or Name Description
17022.1 1-"5V Crimp"(R6) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel
mechanically attached to 15/32"plywood or Wood Deck with
fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
assembly in compliance with the installation method listed in Created by Independent Third Party:Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2 2-"5V Crimp"(R6) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof
panel,mechanically attached to 15/32"plywood or Wood
Deck with exposed fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-Table A Evaluation Reports
Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032
assembly in compliance with the installation method listed in ALUM ssr.pdf
this report and applicable code sections of FBC. Refer to Created by Independent Third Party:Yes
manufacturer's installation instructions.
17022.3 3-"1.5" Mechanical Seam"(115) 1.5"rib height, 16"wide,24 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ:Yes seam 24aa ssr.pdf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.3 1.5 MECHANICAL
the installation method listed in this report and applicable seam 24ga ssr.pdf
code sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.4 4-"1.5"Mechanical Seam"(115) 1.5"rib height, 16"wide,0.032"aluminum,standing seam
roof panel mechanically attached to 15/32"plywood or Wood
Deck with clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ:Yes ALUMINUM ssr.pdf
Impact Resistant:No Verified By: Locke Bowden,P.E.49704
Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions and Evaluation Reports
limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
the installation method listed in this report and applicable ALUMINUM ssr.pdf
code sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes
instructions.
17022.5 5-"1 in. Nail Strip"(115) 1"rib height,16"wide,26 gauge steel,standing seam roof
panel mechanically attached to 15/32"plywood or wood deck
with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.odf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/Table A Evaluation Reports
Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf
limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes
t
1
Product
2160 SW Poma Drive
Palm City, FL 34990
Q72)872-404-
Florida Prod
772)872-8034.. . . P . .
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule #61G20-3
Compliant: Keystone Certifications
Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.)thru
bottom of support.
Adhesive/Sealant : Bostik 91571" Chem-Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads METHOD 1 METHOD 2
DESIGN PRESSURE* -86 PSF Main field -97.25 PSF Perimeter
FASTENER SPACING 6" O.C., 6" O.C.
SEAM ADHESIVE Not required 3/16" continuous bead
(see detaiW�
Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: IS27
UL 580-06&UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen#1
t
,!EQUIVALENCY. UL1897-04 is equivalent to Test Standard UL1897-12. !Design Pressure mar in of safe Z.�I .
Certificate of Independence:
Locke Bowden, P.E.does not have,not will acquire a financial iopmstRn�y�company manufacturing or distributing products
under this evaluation. ��90%C D• 80, :!®o
Locke Bowden, P.E.is not owned,operated,or controlle y+�cbmRi ft 9Sanc turer,or distributing products under this
report.
a • N
• • seal
��•` STATE OF
e
Limitations:
1.Undedayment to be compliance with current Florida Building Code(FBC)2017 6th ed..
2.Minimum slope to be compliant with Florida Building Code 2017 6th ed.,and per with Manufacturer's installation reference.
3.Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method: 1-D
4.Engineering analysis for"project specific approval by local authorities wfjurisdiction is allowed by other registered engineers.
5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7.This report does not imply warranty,installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel -Details
16"
Panel Profile
WIN 16"-o.c.
Deck:
15/32"or greater Plywood,or
-Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3116"Bead Bostik 915TM Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 X 1"Min. per Table"A"
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
i
FL 17022.5 1.0 Nail Strip (26GA Steel), 16"Wide Roof Panel -Details
Fastener
#10 X 1"Min. per Table"A"
Pancake Head Wood Screw
1"Nail Strip Roof Panel
,01
A
��`�..""Y�.'+:�ti�'`i73r..� ��95`�'�.`:W)�;s}t\`^�a_•�-:,,.,.5`_.''•i.�C.1S4::�.�/L4,�`�:3lYGV�` �S°�•'f�
Seam Adhesive Application:
Deck: For Method 2
15/32"or greater Plywood, or Apply 3/16"Bead Bostik 915T11 Sealant
-Wood plank Continuous Along Male Rib Vertical Flange
(Refer to Table"A")
Isometric View