Loading...
HomeMy WebLinkAboutProduct Approvals-opening 9-10 1/4/2018 Florida Building Code Online 1,;t1[F317s'fsi BCIS Home i Log In User Registration i Hot Topics i Submit Surcharge i Sta I&Facts i Publications i FBC Staff i BCIS Site Map i•Links i Search i Florida QO Product Approval r USER:Public User OPEN# 9-10 Product Anoroval Menu>Product or Aoolfcation Search>Aoolication List>Application'Detall } r alai 7,i,15 FL# FL9520-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived L Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative )ay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext 221 amonteverde@cws.cc Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer i Evaluation Report- Hardcopy Received I Florida Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich,PE l�: Validation Checklist-Hardcopy Received Certificate of Independence FL9520 R7 COI EvalReport836B.pdf Referenced Standard and Year(of Standard) Standard Year AAMA 450-10 2010 ASTM E1886-05 2005 ASTM E1996-09 2009 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvlHvmuJRWcZ12gTuypub1 NDOfxVcZHZIO%3d 1/2 i 1/4/2018 Florida Building Code Online FI-9520 R7 Eouiv FL9520 Equivalency Ddf Sections from the Code I ' Product Approval,Method Method 1 Option D Date Submitted 09/29/2017 Date Validated 10/02/2017 Date Pending FBC Approval 10/05/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 9520.1 3"Alum.Tube Mullion 3"Alum.Tube Mullion, Horizontal&Vertical, Fin&Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9520 R7 II CWS-836B.12df Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions and FL9520 R7 AE EvalReoort836B.pdf Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. 9520.2 4"Alum.Tube Mullion 4"Alum.Tube Mullion, Horizontal&Vertical, Fin&Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9520 R7 II CWS-837B.pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions and FL9520 R7 AE EvalReport837B.1df Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. 9520.3 5 1/2"Alum.Tube Mullion 5 1/2"Alum.Tube Mullion, Horizontal&Vertical, Fin&Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9520 R7 II CWS-838B.pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions and FL9520 R7 AE EvalReoort838B.pdf Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. Baric F-—e., i Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: _fru_ ® eCheci: M i Credit Card Safe i https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvlHvmuJRWcZl20TuypublNDOfxVcZHZIOg/o3d 2/2 i i URNER � 1239 Jabara Ave. North Port, FL 34288 ENGINEERING & i Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #25779 Evaluation Report 836B September 26, 2017 Product Description: PVC 3"Mullion H-1758 Manufacturer: Custom Window Systems, Inc. 1900 SW 44th Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above-listed per roduct the requirements of FAC P P Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6th Edition(2017) Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A. Turner, P.E.,at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-83613, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3833-1, -1A, -2, -2A, -3, and-3A, from National Certified Testing Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E. a. Testing Performed: TAS 201/202/203-94, ASTM E 1886-02/04/05, ASTM E 1996- 04/06/09, and AAMA 450-06 4) Supplemental Calcs. to support CWS-83613, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-83613. Limitations of Use: This product: • May be used up to the sizes and design pressures as shown in CWS-83613, using clips as shown in CWS-836B • Is Large Missile Impact Resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • May only be used with Custom Window System, Inc. windows,please see separate individual window unit approvals for applicable design pressures and for more details. The lower of the individual window design pressures and the mullion design pressures shall apply to the entire assembly. • Requires 6063-T6 aluminum mullion and clip extrusions. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. ��tysti�u�i,roii G'E 14 .�'Q��i� Lucas = No aS201 ••� 9/26/2017 Turner * :* = Lucas A. Turner, P.E. 2017-09-28 :i'= FL PE#58201 07:30+20:00 STAYS of W: o �,. ....••' ON A GENERAL NOTES: 3" PVC MULL BAR - LARGE-MISSILE IMPACT -1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH WINDOW SYSTEMS SHOWN w/DIFFERENT OPTIONS THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL 1900 SW 44TH AVE. D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. OCALA,FLORIDA 34474 W W W.CW S.CC 2.CONFIGURATIONS(SEE SHEETS 2-3):VERTICAL OR HORIZONTAL. 3.SEE MULLION CHARTS FOR MAX.DESIGN PRESSURES AND LENGTH. 3" PVC r———— (REFER TO SHEETS 2-3) MULL BAR 4.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED IN THE IMPACT / DESIGN OF THIS PRODUCT.SEE SHEETS 9-10 FOR ANCHOR DETAILS. W INDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. O J Z Q 5.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. z w J OQ ¢w 0 p 6.DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LESSER p Z o Z}O=Z Co DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNITS. LL F w Z F-�2_ ANCHOR CLIP ANCHOR CLIP Z Z 2:R a w 0 0 A c 7.DESIGN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT O 0~Z z a a U UUH 6 7 I APPLYONLYTO THE MULLION.WINDOWS MUST BE APPROVED UNDER SEPARATE Z Z-0 0 Z O n u) I O B O II O } a-ow°xOZ B 8 APPLICABLE LOCAL LAWS,BUILDING CODES,IORD ORDINANCES OR OTHER SAFTEY F �}� O -- -- ---- _ REQUIREMENTS RESTS SOLEY WITH THE ARCHITECT,ENGINEER OF RECORD, w 0 O w m 0 w m w BUILDING OWNER OR CONTRACTOR. z ow 0 COCL F 9.SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS w r w w 3:w DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY Q. X x X CUSTOM WINDOW SYSTEMS,INC.AND MUST BE MADE OUT OF VINYL PVC OR EXTRUDED ALUMINUM. Q Q Q 10.VERTICAL MULLED UNITS MAYBE MULLED INDEFINITELY AS LONG AS THE SINGLE P'CEN . ........ T UNIT W IDTH AND HEIGHT ARE NOT EXCEEDED,AND MULLIONS ARE ANCHORED AS �� 5 SHOWN HERE IN. G F E D ANCHOR CLIP v t No 58201 10 10 9 s 11.HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULLED UNIT. VERTICAL MULLION IS USED TO MULL SIDE BY SIDE UNITS TOGETHER. D; EXAMPLE HORIZI.VERT.MULLION FOR SECTION VIEW ONLY A' OF 4U F ,� ANCHOR CLIP Lucas Turner 20170928 - - 7� I O II O I 07:12+20:00 9/26/2017 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 v PH.941-380-1574 X X I I SHEET DESCRIPTION: TABLE OF CONTENTS4 GENERAL NOTES AND GENERAL NOTES&ELEVATIONS...............1 ELEVATIONS -- -- DRAWN BY: DATE: DPCHARTS.................................................2-3 BOM&EXTRUSIONS.....................................4 ANCHOR CLIP ADE 09/27/12 EXTRUSIONS.................................................5 DWG#: REV.: SECTION VIEWS.........................................6-7 ZEXAMPLE VERTICAL MULLION FOR CONFIGURATIONS&ANCHOR NOTES.......8 VCOWS FOR SECTION VIEWS ONLY CWS-836 B INSTALLATION DETAILS..........................9-10 SCALE: SHEET 1.25 1 OF 10 Design Pressure Chart(PSF)for NON-INTERSECTED Impact PVC 3"Mullion H-1758,with 1522 clips using four(4)#10 Screws into WOOD or METAL or 3/16"ITW Tapcons or ELCO ULTRACONS into SOLID CONCRETE /� or WOOD per each end of mullion. HOLLOW or GROUT-FILLED BLOCK require 1/4"ELCO ULTRACONS. !! f/lJC 9mg.L/a(/� - - _ OPENING SIZE(in.) - ---- WWI(N5LDOWSYSTEMS_Ln(,L��J 39 45 51 1 57 63 1 69 75 318 81 87 1 93 99 107 318 114 120 126 132 138 1453/8 1900 SW 44TH AVE. 37 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 OCALA,FLORIDA 34474 6 423/4 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 WWW.CWS.CC 48 314 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 531/8 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 3" PVC z 57 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 Lu J 63 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 78.9 76.6 74.8 72.5 1 65.0 65.0 MULL BAR 65 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 IMPACT gg 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 63.5 72 65.0 65.0 65.0 65.0 65.0 65.0 65.0 64.9 61.7 59.1 56.9 53.7 ¢ z � a z 2 DP CHART IS FOR: z W-10 W 0 a w o w NON-INTERSECTED IMPACT 3"MULLION 1758,HORIZONTAL OR VERTICAL,USING(PER END): LU z m z r O it m_ LL ;-z W ZH3:2x 1522 CLIPS z zx�¢jrw00 4 # O OHOz0-Pa)K 3/16"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD 1 F U U U Z) o-r uJ a Z-�Zzl-7cn z OZU(6 - -(4) 1 > Q�Ow9109 ------------------------------------------------ �¢� F-Uzvi - Design PressureChart(PSF)for NON-INTERSECTED Impact PVC 3"Mullion H-1758,with 1776 clips with six(6)#10 Screws into WOOD or METAL or 3116"ITW Tapcons or ELCO ULTRACONS into SOLID CONCRETE or w OL O w Cn o w U)w WOOD per each end of mullion. HOLLOW orGROUT-FILLED BLOCK require 1/4"ELCO ULTRACONS. a z Co a �0 U) OPENING SIZE(in.) 0 _~Of w 3 W 39 45 51 57 63 69 75 318 81 87 93 99 107 3/8 114 120 126 132 138 145 3/8 CL f- o a 37 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 J 42 3/4 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 tlrrrrrrrrrr = 483/4 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 ��``�pP10REyy TC/4�i f 53 118 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 ; �C Z 57 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 J No 58201 •'•�i'� 63 80.0 80.0 80.0 80.0 80.0 50.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 J 65 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 J 68 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 '9 STATE of ' 72 65.0 65.0 65.0 1 65.0 1 65.0 65.0 65.0 1 64.9 61.7 59.1 56.9 53.7 1,x,0'.4 0 R 10..0 DP CHART IS FOR: NON-INTERSECTED IMPACT 3"MULLION 1758,HORIZONTAL OR VERTICAL,USING(PER END): NOTES: �ONA111���`� 1.THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION IS SHOWN IN BOLD. 1776 CLIPS 2. (6)#10 SCREWS INTO WOOD or METAL AN INTERSECTED MULL BAR HAS OTHER MULL X -(6)3/16"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD BARS)ATTACHED TO IT(SHOWN IN DASHES) THROUGH THE USE OF MULL BAR CLIPS. -(6) 1/4"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK 9/26/2017 INTERSECTED MULL BAR WILL BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS. LUCAS A.TURNER,P.E. 3.NON-INTERSECTED MULL BARS CAN BE ATTACHED FL PE#58201 TO THE SUBSTRATE AND OTHER MULL BARS. 1239 JABARA AVE. TWIN TRIPLE TRANSOM OVER TWIN TRANSOM OVER TRIPLE NORTH PORT,FL 34288 VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION r TWIN TRIPLE TWINITRPLELMUL PH.94TION: 1574 } HORIZONTAL MULLION HORIZONTAL MULLION HORIZONTAL MULLION SHEET DESCRIPTION: DP CHARTS F- r T NON-INTERSECTED z zr r tj OPENING MULLS J J 0 Z SIZE DRAWN BY: DATE: w z ADE 09/27/12 L O W DWG#: REV.: a 0 CWS-836 B I I I II L II I L I II r SCALE: F-- OPENING SIZE I --i OPENING SIZE I-- 4--- OPENING SIZE---I OPENING SIZE F-- I�MULL LENGTH --I I i�MULL LENGTH --I MULL LENGTH SHEET 1:1 2 OF 10 Design Pressure Chart(PSF)for INTERSECTED Impact PVC 3"Mullion H-1758,with 1522 clips using four(4)#10 Screws into WOOD or METAL or 3/16"ITW Tapcons into SOLID CONCRETE or WOOD,or 1776 clips 086199008- OPENING ��� ��� with six(6)#10 Screws into WOOD Or METAL or 3/16"ITW Tapcons into SOLID CONCRETE or WOOD per each end of mullion. HOLLOW or GROUT-FILLED BLOCK require 1/4"ELCO ULTRACONS. // r//1990 8- /(/{ OPENING SIZE(in.) --- - - - --- - - -- - lW`IINDSOAvW SYSTEMS_Ilf�fj�j/�Ij 39 45 51 57 63 69 753/8 81 87 93 99 110 3/8 114 120 126 132 138 1453/8 1900 SW 44TH AVE. 37 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 OCALA,FLORIDA 34474 _ c 42 3/4 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 WWWCWS.CC = 48 3/4 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0- 31/8 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 3" PVC w 57 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 48.1 MULL BAR 63 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.4 47.3 68 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.8 47.6 IMPACT :3 72 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 45.4 44.0 75.375 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 46.8 44.0 40.0 g Z "z I- ow0 avow W z0O? �- DP CHART IS FOR: z w o =-z L _ INTERSECTED IMPACT 3"MULLION 1758,HORIZONTAL OR VERTICAL,USING EITHER(PER END): o F w z O W�ro Z zx�aWwp0 1522 CLIPS O O 1-O(3 Q=j.-0� rn -(4)#10 SCREWS INTO WOOD or METAL O OF-z° f-U)n. (4)3/16"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD z z0(D� z F o- 4 1/4"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK ¢ Z O U)Z O u 0 ( ) ¢�O w O O z 1767 CLIPS of U)0 - -- -(6)#10 SCREWS-INTO WOOD or METAL w 0 0 cn w rn o0 w U (6)3/16"ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOODa z=D. W O m (6) 1/4"ELCO ULTRACONS INTO HOLLOW or GROUT-FILLED BLOCK 0 x F-0 a. wwCn a. F- a af D TWIN/TRIPLE HORIZONTAL MULLION J,1No 58201 •5��1 VERTICAL MULLIONk �= Q: STATE OF .;��/` Ul F ------ z �SINGLE� `'�``SS•'ONA� cn G�� TWIN W w OR W O I TRIPLE 1 ------ IUNITSI L BELOW I I 9/26/2017 4 _OPENING SIZE --I Fes- MULL LENGTH" LUCAS A.TURNER,P.E. FL PE#58201 _ 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: NOTES: DP CHART 1.THE MULL BAR IN FOCUS FOR ANY GIVEN INTERSECTED MULLS CONFIGURATION IS SHOWN IN BOLD. 2.AN INTERSECTED MULL BAR HAS OTHER MULL DRAWN BY: DATE: BAR(S)ATTACHED TO IT(SHOWN IN DASHES) ADE 09/27/12 THROUGH THE USE OF MULL BAR CLIPS. AN DWG#: REV.: INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS. CWS-836 B 3.NON-INTERSECTED MULL BARS CAN BE ATTACHED SCALE: SHEET TO THE SUBSTRATE AND OTHER MULL BARS. 1:1 3 OF 10 ITEM PART# DESCRIPTION "T"MULLBAR CLIP "L"MULLBAR CLIP 1 H_1758 1 3/8"x 3"MULLION TUBE LINE ITEMS NOT USED: FRAME TYPE OPENING 2 #10 OR#12 HEX WASHER HEAD TEF SCREW'(see note below) 5-6,12 (F-1522-XXX) (F-1767-XXX) Or77/((gum. 3 #1Q x 1 1/2",PANHEAD PHILIPS ZINC - ---NEW—---_ 1522 - -----F -013-_ F-1767-001 ((NDll��((f� FLANGE - WINDOW SYSTEMS- 4 #10 FLAT WASHER RETRO F-1522-006 > F-1767-001 1900 SW 44TH AVE. 7 S-1897 MULLION CLIP FIN NEW F-1767-004(L&R) OCALA,FLORIDA 34474 8 SEALANT RETRO F-1522-013 F-1767-004(L&R) WWW'CWS.CC 9 S-1895 DRIP CAP NEW NOT RECOMMENDED F-1767-001 10 S-1896 FLANGE ADAPTER BOX RETRO F-1522-006 F-1767-001 3" PVC 11 9-6018 MULLION INTERIOR COVER 13 P-3486 MULL BAR CAP MULLBAR 14 F-1522-013 3"SLOTTED NEW CONTRUCTION FIN MULL CLIP IMPACT 15 F-1522-006 3"SLOTTED T-CLIP 16 F-1767-001 L-ANGLE 3"MULL CLIP,STANDARD 17 F-1767-004L L-ANGLE 3°MULL CLIP,FIN,LEFT Q O <Z O 1- owO COwOo 18 F-1767-004R L-ANGLE 3"MULL CLIP,FIN,RIGHT z .-Jo <r z w 19 #10 HEX WASHER HEAD TEK SCREW a z U) >O m m 20 #10 FH TEK SCREW LL F-uj wig= z Zx2<Kw0O O OHO <_�of 'USE WOOD SCREW SIZE(#10 OR#12),SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENT U U U)F.z D-F U)D- cl �z Oz0ozoOV F-IL2OOLLz 1 3/4" 1 112' 11/16" ''� �L32 1 7/16" 1 7116" 9/32" 2 3Q}�Fw..U I=_-Z -- 7/16"J I T 112"� i I --� ~ LLp~}0Li�w 11 1 114"TV, lnl, L 1%6" 7/1s• 7n s• a z=-a_��0�y1/16" L6" 1 " O w F.O 0-x w N-- - DRIP CAP S-1895 1 13/16" f1 15/16"I 1 13/16" 3/6 a F=- a � wa MULLION INTERIOR 1 3116" COVER S-6018 FLANGE ADAPTER 5-1896 2 7/16" ]/� �{ 41/8" 1 11/16" (17/8") ,,,t1ui1+0ei����' r 1 3/8"-1 0 1/4"(TYP) 4 1/8" 0q �SOR�.1 �- !"' + L � �� 5 G . 1 13/16 3/8" ��jGQ,�.�VGENa'•.;QiL�= No 58201 S�2 TOP VIEW 2 7/16" 1 5116" 213/16" 1/8° �: STATE OF : u2Z 4 21/16"— J n 7 1 3/4"--�-1 318"--I 15 S1ONA;E0�`�� 1 3/16° 1/8" 2 3/16" 3"MULLBAR H-1758 i 1/8" y rf MULLION CLIP S-1897 `/--" I 9/26/2017 14 Fes- 471 - �I 21/4" LUCAS A.TURNER,P.E. F-1522-006 FL PE#58201 1/8" RETRO/FLANGE CLIP 1239 JABARA AVE. 4 NORTH PORT,FL 34288 03 IL PH.941-380-1574 1574 4 718"� SHEET DESCRIPTION: F-1522-013 NEW CONSTRUCTION/FIN INSTALLATION BOM AND EXTRUSIONS A SCORE,BEND AND BREAK TO REMOVE FIN FOR FRAME DRAWN BY: DATE: ATTACHEMENT TO MULL BAR ADE 09/27/12 DETAIL DWG 0: REV.: TYP.FIN FRAME 3:1 CWS-836 B NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. SCALE: SHEET 1:2 4 OF 10 it • FRAME TYPE OPENING "T"MULLBAR CLIP "L"MULLBAR CLIP (F-1522-XXX) (F-1767-XXX) // n/7(tv�r®�•� /„{/,{ - - NEW----F-1522-013 .___ F-1767-001 • FLANGE WINDOVN SYSTEP°iS - - RETRO F-1522-006 F-1767-001 1900 SW 44TH AVE. NEW F-1522-013 F-1767-004(L&R) OCALA,FLORIDA 34474 FIN WWW.CWS.CC RETRO F-1522-013 F-1767-004(L&R) NEW NOT RECOMMENDED F-1767-001 BOX RETRO F-1522-006 F-1767-001 3"PVC MULLBAR IMPACT a z � <Z3� ow0COw0W z woo 17 16 i g R0§>-oQf �m LL �wz��gx Z Zmm<MWOO OOI-OUa=F-� F--2 3/4' 2 1/4" Z o(D=) U� zow r 2 F-Z? Of F r�z — — - W owo�aiowu0-iw - - - _ 1 518" (2 3/4') 2 7/16° m z w O-1 co r _ w My 3/8"(2X) d D. O. 7/16"THRU(TYP) 1/4"THRU(TYP) 1!2" OUTSIDE ,,S,, CEIJNI,TG,���. 1/4"(TYP) 7/16"(TYP) j- No 58201 •.��2 3/8" O 318" '90• STATE OF ;btu` 1 5/8" (2 314°) 15/8 1 �i�E`°-.<O R L CD is 6 7/8" 9/26/2017 LUCAS A.TURNER,P.E. 2 3/4' "L'ANGLE 3'STANDARD MULL CLIP-F-1767-001 FL PE#58201 5° 1239 JABARA AVE. 5° NORTH PORT,FL 34288 "L"ANGLE 3"MULL CLIP,FIN(LEFT)F-1767-004L 'L"ANGLE 3"MULL CLIP,FIN(RIGHT)F-1767.004R PH.941-380-1574 OUTSIDE SHEET DESCRIPTION: EXTRUSIONS DRAWN BY: DATE: ADE 09/27/12 DWG#: REV.: CWS-836 B SCALE: SHEET 1:2 50F10 I — -- - WINDOW SYSTEMS-M---- 1900 SW 44TH AVE. OCALA, YSTEMS- _ --- OCALA,FLORIDA 34474 W W W.0 W S.CC 3"PVC MULLBAR SEAL BEHIND FLANGE SEAL BEHIND FLANGE O PRIOR TO ATTACHING LENGTH OF WINDOW FRAME IMPACT PRIOR TO ATTACHING 2 TO MULLION li 2 GROOVE PRIOR TO ATTACHING 2 1 TO MULLION Q ER Z Q B 11 9 I 11 11 O 11 z o WJo awzW p FIN MUST BE REMOVED �d w Z O Z W--t b o0 awn >-0 ' :md WHERE WINDOWS Z Z ¢� CONNECT TO MULL z Z w w Z w w w 0 o O O OHOUQ=F.(L Qp O U��ZD.F-!n d• �Qcl � 0 I I z O(Do–ZO --SUN I LLJJ F--¢U_20 LLZ �VERTICAUHORIZONTAL MULL BAR SECTION Z C6 W OLL O w ai o w cn w -- A -HORIZONTAL MULL BAR SECTION l HORIZONTAL MULL BAR SECTION s BOX FRAME W INDOW R z w O J Ln i-- FLANGE 6 FRAME WINDOW s FIN FRAME WINDOW w F p a=g} CL F- -------------- ------ - a imam I I -I-- ----------------- ------------- --- ----------- 11 1 2 APPLY SEALANT ALONG FULL :`Gp�?. GENS'. ;p 4, 11 1 2 LENGTH OF MULLBAR GROOVE PRIOR TO ATTACHING DRIP v! No 5$201 •t�9 ADAPTOR '9 STATE OF46 z a FIN MUST BE REMOVEDWHERE I CONNECT TO MULS DETAIL A Z� 9/26/2017 SEAL BEHIND FLANGE 10 SEE DETAIL B SEAL BEHIND FLANGE 10 (SEE DETAIL B) PRIOR TO ATTACHING ( ) LUCAS A.TURNER,P.E. PRIOR TO ATTACHING TO MULLION I APPLY SEALANT ALONG FULL FL PE#58201 TO MULLION LENGTH OF MULLBAR GROOVE 1239 JABARA AVE. PRIOR TO ATTACHING FLANGE NORTH PORT,FL 34288 PPVERTICAL MULL BAR SECTION VERTICAL MULL BAR SECTION I ADAPTOR 1 PH.941-380-1574 FLANGE FRAME WINDOW s FIN FRAME WINDOW SHEET DESCRIPTION: SECTION VIEWS MULLS �O o� DRAWN BY: DATE: ADE 09/27/12 DWG#: REV.: 10 I I DETAIL B CWS-s36 B SCALE: SHEET 1:2 6 OF 10 aaggum.w - - - WINDOW/SYSTEMS- 1900 SW 44TH AVE. C) 0 OCALA.FLORIDA 34474 WWW.CWS.CC A — = — - - 3"PVC O 7f r ; ii y= { ;;r ,i MULLBAR i[� ii IMPACT ¢ z azo — 1u ur �ig r �r z woo ¢wFoo W ZOZ_ W--1= F 2i 0 A �g x Z ZWx2aZ IrWOO 1 O ol-o�axl-� SECTION VIEW A-A U TOP VIEW z ooUui?�c�i�n FIN FRAME >- QzWu�1p0WOZ Z u W D-s2 W O J U)H z- IL a� ~ 2 5"MULLBAR( ) D O — Q O _ (SEE SEPARATETE APPROVAL FOR 2 4"MULLBAR(H-1759) 2 � APPROPRIATE DP CHARTS) APPROPRIATE DP CHARTS) Oi 'I Zol EE SEPARATE APPROVAL FOR O 0� F^0 ;•`JVQ`?.��0 E NSF 9 9 STATE OF SEE NOTE 1 7 11116"MAX.EDGE DISTANCE SEE NOTE 1 7 11/16" . 1MAX EDGE DISTANCE '��0�� .<p p SOP G\�� SEE NOTE 1 7 11/16"MAX.EDGE DISTANCE � ��'SS1ONALIII a , a a 19 SEE NOTES 1&2 1 19 SEE NOTES 1&2 r 119 SEE NOTES 1&2 (1 EA./CLIP) (1 EA./CLIP) (1 EA./CLIP) SEE NOTE 4 0 SEE NOTE 4 20 9/26/2017 SEE NOTE 4 20 C 5'HORIZ.TO 3'VERT.MULLBAR SECTION C 4"HORV TO 3"VERT.MULLBAR SECTION t'C�3"'OR" VERT.TO 3"VERT.MULLBAR SECTION LUCAS A.TURNER,P.E. 7 FLANGE FRAME WINDOW 7 FLANGE FRAME WINDOW 7 FLANGE FRAME WINDOW FL PE#58201 1239 JABARA AVE. NOTES: NORTH PORT,FL 34288 PH,941-380-1574 1. SLIDE CLIP INTO LOCATION AND SECURE WITH ITEMS 19(QTY 1)AND 20(QTY 1),AS SHEET DESCRIPTION: SHOWN ABOVE. SECTION VIEWS 2. PRE-DRILLED HOLES(THRU HN CLIP 1897),BY THE INSTALLER, MULL INTERSECTIONS MAY BE LOCATED AS NEEDED WHILE MAINTAINING A MINIMUM CLIP EDGE DISTANCE OF 9/32"AND A MINIMUM CENTER TO CENTER SPACING OF 1/2". DRAWN Br: DATE: 3. THE ABOVE SECTIONS APPLY TO ALL MULLBAR-TO-MULLBAR CONNECTIONS, ADE 09/27/12 REGARDLESS OF ORIENTATION(i.e.,HORIZONTAL OR VERTICAL).THE FULL LENGTH DWG#: REV.: MULL MUST BE THE SAME DEPTH,OR GREATER,THAN THE INTERSECTING MULL. CWS-836 B 4.INTERIOR MULL ANCHOR ATTACHMENT SCREW THRU VERTICAL MULL INTO MULL SCALE: SHEET CLIP. PRE-DRILL PILOT HOLE THRU ALL MATERIAL. 1:2 7 OF 10 NOTES: V-(yi/-19900 1.THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION IS SHOWN IN BOLD. TWIN TRIPLE TRANSOM OVER TWIN TRANSOM OVER TRIPLE 2.AN INTERSECTED MULL BAR HAS OTHER MULL WINDOW SYSTEP •_ _ VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION VERTICAL MULLION BAR(S)ATTACHED TO IT(SHOWN IN DASHES) 1900 SW 44TH AVE. r THROUGH THE USE OF MULL BAR CLIPS. AN OCALA,FLORIDA 34474 INTERSECTED MULL BAR WILL ALWAYS BE WWW.CWS.CC ATTACHED TO THE SUBSTRATE AT BOTH ENDS. �- 3.NON-INTERSECTED MULL BARS CAN BE ATTACHED TO THE SUBSTRATE AND OTHER MULL BARS. 3•• PVC w z r r J J W W MULL BAR IMPACT L L -' I I I LII LI a z ¢z o F� ZOPENING SIZE OPENING SIZE OPENING SIZE" OPENING SIZE w Z <r w ZO O F-W§zO3:g= z zmm<wwpp O OF-O ¢=j_� TWINITRIPLE HORIZONTAL MULLION O0(1)1­-z d h-cn D. TWIN TRIPLE TWIN/TRIPLE VERTICAL MULLION 77��"" - Z p V' �--?U- HORIZONTAL MULLION HORIZONTAL MULLION HORIZONTAL MULLION I Q F,?� O O w z T I M� F-p- -- -----_ y _ 9:1 w of OOI�W0W(AW —N L OPENING z z �SINGLEI a z=DL O Z J w I TWIN I p w�� Ws�U IL OR rL s D- w Lu c7 __ __ O I TRIPLE I D_ ~ O z —— I UNITS L w I BELOW a L L or +'pAOREW '1 --MULL LENGTH --I i I�-MULL LENGTH --I MULLLENGTH I " +++ w r�/���� OPENING SIZE MULL LENGTH :+9=.C E lJ JGP:v� SF'%,Q'LC� v.• N. 58201 t t °ros ;mac STATE OF :�[U` ii F .CORtOPp��.` NOTES: 1.AT MULLION LOCATION,ATTACH WINDOW UNIT(S)TO MULLBAR THRU FRAME AS SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENTS.IF ALUMINUM ATTACHMENT IS NOT SPECIFIED IN THE WINDOW UNIT APPROVAL �✓� DOCUMENTS,FOLLOW THE ANCHOR SPACING AS INDICATED IN THE WINDOW APPROVAL FOR ATTACHMENT TO WOOD SUBSTRATE,USING A HEX WASHER HEAD TEK SCREW OF THE SAME SIZE(#10 OR#12)AS THE WOOD SCREW INDICATED IN THE WINDOW APPROVAL.TEK SCREWS SHALL BE LONG ENOUGH TO ENSURE THREE(3)THREADS OF PENETRATION BEYOND THE INSIDE WALL OF MULLBAR. 9/26/2017 2.MULL CLIP INSTALLATION ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 9. LUCAS A.TURNER,P.E. 3.ALL MULL CLIP INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT W ITH PRESSURE TREATED FL PE#58201 WOOD MUST BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. NORTH PORT,FL 34286 4.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE PH.941-380-1574 MINIMUM SPECIFIED IN TABLE 1,SHEET 9. SHEET DESCRIPTION: 5.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE-1X BUCKS CONFIGURATIONS AND ARE OPTIONAL. ANCHORAGE NOTES 6.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED AS INDICATED BY THE PRE-DRILLED HOLES AS SHOWN IN THE CLIP LAYOUTS ON SHEETS 4-5. DRAWN BY: DATE: ADE 09/27/12 7.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG#: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 9. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-836 B 8.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA200(FLANGE WINDOWS), FMAANDMA250(BOX WINDOWS),FMA/AAMAANDMA300(EXTERIOR DOORS) 1:1 $QF 10 it Dmg - WINDOW SYSTEMS v - - -- 1900 SW 44TH AVE. - - ---- OCALA,FLORIDA 34474 W W W.CW S.CC 3" PVC MULL BAR IMPACT RETRO FIT "L"ANGLE MULL BAR CLIP MULL BAR CLIP TWO REQ'D PER EACH END OF MULL z W O to IW-3 O MULL BAR MULL BAR Z W J o a r Z W 1111 lfll o zU)?}O��m Q 2� ,J II_- - - Z Z=�¢xWop r s INSTALLATION ANCHOR o opo a =INSTALLATION ANCHOR O U U)F-U o_F W O. SEE TABLE 1 SEE TABLE 1 p Z- Z 2 p r/j JL -� ADD STRUCTURAL ELEMENTS _ Ji= _.`� li_ ADD STRUCTURAL ELEMENTS Z O Z U Z p O SEALANT ALONG = __- - - -- AS REQ'D TO MAKE LEVEL FOR SEALANT ALONG _ - - AS REQ'D TO MAKE LEVEL FOR a �'-tL O O a Z OUTSIDE EXPOSED "— MULL BAR OUTSIDE EXPOSED — MULL BAR ¢ w U F O N EDGE BY INSTALLER EDGE BY INSTALLER -PERIMETER-SEALANT O _ PERIMETER SEALANT a w O p U))0 w u)w BY INSTALLER MIN.EMBEDMENT BY INSTALLER MIN.EMBEDMENT d Z=O_ O tq U)Lu o�rnr INSIDE AND OUT INSIDE AND OUT wl SEE TABLE 1 SEE TABLE 1 - - -- - O0 =H K W 2 BE>_ x � a w�a SUBSTRATE BY OTHERS SUBSTRATE BY OTHERS SEE TABLE 1 SEE TABLE 1 MIN.EDGE DIST.MIN.EDGE Huunr SEE TABLE DIST SEE TABLE 1 `��+�� yOREN�+Tr�'� D VERTICAL SECTION E VERTICAL SECTION . `` .?;�GEIJS 9 TYPICAL FLANGE(RETRO FIT)ANCHORAGE 9 TYPICAL FLANGE("L"ANGLE)ANCHORAGE HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION v. No 58201 X90 STATE OF • :4L, ,�rr4s+ONA z� 9/26/2017 NOTES: LUCAS A.TURNER,P.E. TABLE 1:APPROVED MULL CLIP INSTALLATION FASTENERS 1.BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME. FL PE#58201 1239 JABARA AVE. SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. 2.SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS NORTH PORT,FL 34288 CONCRETE(2.0 KSI MIN.) 3/16"RW TAPCON 1" 3" AFTER INSTALLATION. PH.941-380-1574 2.85 KSI MIN. 3/16"ELCO ULTRACON 1-3/4" SHEET DESCRIPTION: 3.RECESS RETRO MULLION CLIP 3/8"MAX.FOR CLEARANCE OF WINDOW HOLLOW or GROUT-FILLED CMU(ASTM C-90) 1/4"ELCO ULTRACON 1-1/4" 2-1/2" UNITAS NEEDED. INSTALLATION DETAILS 2X MIN.SOUTHERN PINE(G=0.55) 3/16"RW TAPCON ( )1-318" 7/8" 4.FOUR 4 ANCHORS REQUIRED PER"T"MULL CLIP,SEE SHEETS 2-3. FLANGE OR ELCO ULTRACON DRAWN BY: DATE: 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" THREE(3)ANCHORS REQUIRED PER"L"MULL CLIP,SEE SHEETS 2-3. ADE 09/27/12 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILT[KW IK-FLEXOR FTW FULL THREAD 7/16" 5.SEAT MULLION TIGHT TO MULL CLIP. DWG#: REV.: (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" I CWS-836 B 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD 6.FORANCHORAGE DETAILS FOR THE WINDOW,REFER TO THE WINDOW 118"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16" SPECIFIC INSTALLATION DETAILS. SCALE: SHEET 1:2 9 OF 10 'I ` - - --- - --- -- - - - - WINDOW SYSTEPNSte' _ __— 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.Cc 3"PVC MULL BAR IMPACT K �: ¢z� RETRO FIT "L"ANGLE CLIP F- ❑w O IMl o O MULL BAR CLIP TWO REQ'D PER EACH END OF MULL z w-j O ¢r Z w W zoz O_ m ¢ �} 2_ z= MULL BAR MULL BAR w w Z II 1(�I 0¢wtYw00 0 0 OFOU¢SFEL -1i JL II INSTALLATION ANCHOR ''-1�JL II -- INSTALLATION ANCHOR Z O O U rn z=U- l�l SEE TABLE 1,SHT 9 I� J 1� SEE TABLE 1,SHT 9 Q-O W 0 2 O z JL_— of of 2� n� ZC6 w O��aiowww SEALANT ALONGE - - _ SEALANT ALONGE - J� w w OUTSIDE EXPOSED OUTSIDE EXPOSED d Z=c_ O EDGE BY INSTALLER D oa°"o' EDGE BY INSTALLER °,o, .. 0 w F-0 (L S EXTERIOR FINISH �o�{ _ MIN.EMBEDMENT EXTERIOR FINISH °o�;�; __ _ RMIKEDGEDIST. MIN.EMBEDMENT a d w a BY OTHERS !- - SEE TABLE 1,SHT 9 BY OTHERS !- - -- SEE TABLE 1,BHT 9 PERIMETER SEALANT PERIMETER SEALANT BY INSTALLER BY INSTALLER INSIDE AND OUT INSIDE AND OUT SUBSTRATE BY OTHERS SUBSTRATE BY OTHERS ,``�� toRW T(���i SEE TABLE 1,SHT 9 SEE TABLE 1,SHT 9 �JGQ°;.4..........E �.•�Q�� ^ MIN.EDGE DIST. " t• No 58201 "t�'I� SEE TABLE 1,SHT 9 / SEE TABLE 1,SHT 9 eF VERTICAL SECTION r G� VERTICAL SECTION 10 TYPICAL FIN(RETRO FIT)ANCHORAGE 10 TYPICAL FIN("L"ANGLE)ANCHORAGE %"b HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION 0 TATE OF :14f .......... A,EAG X� 9/26/2017 LUCAS A.TURNER,P.E. NOTES: FL PE#58201 1239 JABARA AVE. 1.SILL STOOL MUST BE FLUSH AGAINST INSIDE OF MULLED WINDOWS NORTH PORT,FL 34288 AFTER INSTALLATION. PH.941-380-1574 SHEET DESCRIPTION: 2.RECESS RETRO MULLION CLIP 3/8"MAX.FOR CLEARANCE OF WINDOW UNIT AS NEEDED. INSTALLATION DETAILS FIN 3.FOUR(4)ANCHORS REQUIRED PER"T"MULL CLIP,SEE SHEETS 2-3. THREE(3)ANCHORS REQUIRED PER"L"MULL CLIP,SEE SHEETS 2-3. DRAWN BY: DATE: ADE 09/27/12 4.SEAT MULLION TIGHT TO MULL CLIP. DWG u: REV.: 5.FOR ANCHORAGE DETAILS FOR THE WINDOW,REFER TO THE WINDOW CWS-836 B SPECIFIC INSTALLATION DETAILS. SCALE: SHEET 1.2 10F 10 I