Loading...
HomeMy WebLinkAboutProduct Approval BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts j Publications Contact Us BCIS Site Map j Link Search ba k)r )Product Approval + USER:Public User Product Approval Menu>Product or ADplication Search>Application Lis[>Application Detail FL FL17022-117 Application Type Revision Code Version 2017 Application Status Approved FILE Cop- Comments 08/18/2017v.date reapply 08/21/17 Archived ❑ Product Manufacturer Extreme Metal Fabricators,LLC e Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 ( lJ Ovalidation@yahoo.com Authorized Signature Richard McKuhen REVIEWED FOR flvalidation@yahoo.comCODE COMPLIANCE Technical Representative Richard McKuhen ST. LUCIE COUNTY Address/Phone/Email 2160 SW Poma Drive ^�w Palm City,FL 34990 SOCC (772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R.Priest,P.E. u Validation Checklist-Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssrpdf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code e ; Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 Summary of Products FL# Model,Number or Name Description 17022.1 1-"5V Crimp"(116) 26 Gauge steel,3/8"rib height,24"wide lapped roof panel mechanically attached to 15/32"plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.pdf assembly in compliance with the installation method listed in Created by Independent Third Party:Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2-"5V Crimp"(R6) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof panel,mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions.Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 assembly in compliance with the installation method listed in ALUM ssrodf this report and applicable code sections of FBC. Refer to Created by Independent Third Party:Yes manufacturer's Installation instructions. 17022.3 3-"1.5" Mechanical Seam"(115) 1.5"rib height, 16"wide,24 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.3 1.5 MECHANICAL Approved for use outside HVHZ:Yes seam 24aa ssr.pdf Impact Resistant:No Verified By: Locke Bowden, P.E.49704 Design Pressure: +N/A/-Table A Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.3 1.5 MECHANICAL the installation method listed in this report and applicable seam 24aa ssr.pdf code sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 17022.4 4-"1.5" Mechanical Seam"(115) 1.5"rib height, 16"wide,0.032"aluminum,standing seam roof panel mechanically attached to 15/32"plywood or Wood Deck with clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.4 MECHANCIAL SEAM Approved for use outside HVHZ:Yes ALUMINUM ssr.odf Impact Resistant:No Verified By: Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party:Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM the installation method listed in this report and applicable ALUMINUM ssr.pdf code sections of FBC. Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 17022.5 5-"1 in. Nail Strip"(115) 1"rib height,16"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R7 11 FL 17022.5 1.0 NAILSTRIP ssr pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.pdf limitations of use.Install the assembly in compliance with Created by Independent Third Party:Yes eeProduct - e e ' 2160 SW Poma Drive Palm City, FL 34990 Q72)8724103 4___ iFlori'daProduct'Approval # 17,022.5 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule #61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.)thru bottom of support. Adhesive/Sealant : Bostik 915Tm Chem-Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details:.Table A Y Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* _ _ -86 PSF Mainfield -97.25 PSF Perimeter FASTENER SPACING r O.C. 6" O.C. SEAM ADHESIVE Not required 3/16"continuous bead see details �._. e _�_t_ _ Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527 UL 580-06&UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen#1&#2 !EQUIVALENCY.UL1897-04 is equivalent to Test Standard UL1897-12. *Desi n Pressure mar in of safe ,2;1 Certificate of Independence: Locke Bowden,P.E.does not have,not will acquire a financial iipmstur u y company manufacturing or distributing products under this evaluation. L Locke Bowden P.E.is not owned,operated,or controll + a V• p e�'�► Y'��mR3�+Oian�fs�turer,or distributing products under this report. ° ' . a seal • STATE OF •�� v�O+ °f i WRID °'���,;,®NAI- �,,;:••' Limitations: A.Undedayment to be compliance with current Florida Building Code(FBC)2017 6th ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 6th ed.,and per with Manufacturer's installation reference. 3.Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method: 1-D 4.Engineering analysis for"project specific approval by local authorities wfJurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6th ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty,installation,recommended product use outside of this report. FL 17022.5 1.0 Nail Strip(26GA Steel), 16"Wide Roof Panel - Details 16" 3/4�— Panel Profile 16"-o.c. Deck: 15/32"or greater Plywood, -Wood plank Integral Snap Lock For METHOD 2: Apply 3116"Bead Bosti k 915TH Sealant Continuous Along Male Rib Vertical Flange Fastener #10 X 1"Min. per Table"A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) FL 17022.5 1.0 Nall Strip(26GA Steel), 16"Wide Roof Panel - Details Fastener - #10 x 1"Min. per Table"A" 3 Pancake Head Mod Screw 1 Nail Strip Roof Panel zf 4 Seam Adhesive Application: -Deck: For Method 2 - 15/32"or greater Plywood,or Apply 3/16"Bead Bostik915TM Sealant -Wood plank Continuous Along Male Rib Vertical Flange (Refer to Table"N) Isometric View