1
36" X 80"
REPLACE DOOR IN 1 OPENING ONLY.
NEW DOOR TO BE IMPACT RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED.
OPENING PRODUCT I DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 36 80 20.00 1 4 54.9 1 -60.9 FL16708.1 65.0 1 -65.0 FRONT ENTRY-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
File COPY
LESS THAN 30%OF STRUCTURE'S VALUE.NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENE GY CONS RVATION CQDE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURESPGy� l
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES REVIe��i19 D R
MEAN ROOF HEIGHT= 126 FT 6 IN CODE COMPLIANGE
PARADISE CONDO UNIT
9600 S. OCEAN DRIVE, UNIT 707 DOOR REPLACEMENT PLAN