HomeMy WebLinkAboutProduct Approval (3) 398 East Dania Beach Blvd.
BUILDING DROPS Suite 338
Dania Beach, FL 33004
A Perfect Solution in Every Drop! 954.399.8478 PH
Certificate of Authorization:29578 954.744.4738 FX
contact@buildingdrops.com
Product Evaluation Report
Of
JELD-WEN, inc.
Design Pro / Smooth Pro / Studio Fiberglass
Impact Approved Opaque Doors
For use in the High Velocity Hurricane Zone (HVHZ)
for
Florida Product Approval
Report No. 41 63,1
Current Florida Building Code
Method: 1— D (Engineering Evaluation)
Category: Exterior Doors
Sub—Category: Swinging Exterior Door Assemblies
Product: Design Pro/Smooth Pro/Studio Fiberglass
Impact Approved Opaque Doors
For use in the High Velocity Hurricane Zone
Material: Fiberglass
Product Dimensions: Y-0"X 6'-8"(Nominal)
Y-0"X 8'0'(Nominal)
Prepared For:
jE.l_D-WEN, inc.
37-37 Lakeport iso .� 11 fill.,
g F. 04
n L
Klaath Falls, OR. 97603. �.� �;, . -
�.
Prepared by: ` s� •�-� �0'=
7
Hermes F,, Norero, P.E.
Florida Professional Engineer#73778
Date: 11/15/2017 �0 ' 1-0 pP.� 1vw
Contents: ''••.......
Evaluation Report Pages 1-4 �i�S�ONA�-���
Digitally signed by Hermes F.Norero,P.E. Her meS10, P.E.
Reason:I am approving this document Florida No.73778
Date:2017.11.17 10:34:29-05'00'
BUILDING DROPS
e Date: 11/15/2017
A Perfect Solution in Every Drop! Report No: 4663.1
Certificate of Authorization:29578
Manufacturer: JELD-WEN,Inc.
Product Category: Exterior Doors
Product Sub-Category: Swinging Door Assemblies
Compliance Method: State Product Approval (1)(d)
Product Name: Design Pro/Smooth Pro/Studio Fiberglass
Impact Approved Opaque Doors
For use in the High Velocity Hurricane Zone(HVHZ)
3'-0"X 6'-8"(Nominal)
3'-0"X 8'-0"(Nominal)
Scope: This is a Product Evaluation Report issued by Hermes F. Norero,P.E. (FL#73778)for JELD-WEN Inc.
based on Method 1d of the Florida Department of Business and Professional Regulation-Florida
Building Commission,
Hermes F. Norero, P.E.does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions A010871,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for
specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the"High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the current Florida Building Code and does not require an impact resistant
covering.
4. Site conditions that deviate from the details of drawing A010871 require further engineering
analysis by a licensed engineer or registered architect.
5. See Installation Instructions A010871 for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida No. 73778
Page 2 of 4
BUILDING DROPS
Date: 11/15/2017
Y} A Perfect Solution in Every Drop! Report No: 4663.1
Certificate of Authorization:29578
Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a Certification Agency through
National Accreditation&Management Institute(FBC Organization#QUA1789).
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
Referenced Data:
1. Product Testing performed by National Certified Testing Laboratories
(FBC Organization#TST1589)
Report# Report Date:
NCTL-210-3916-02 w/addendum 06/10/14
NCTL-210-3930-01 02/24/14
NCTL-210-3930-02 03/10/14
NCTL-210-3925-03 02/07/14
TAS Report Engineer of Record: Gerard J. Ferrara, P.E.
Report# Report Date:
SJW2013-194 w/addendum 06/10/14
SJ W 2013-131-TAS 07/02/13
SJ W 2013-206-TAS 11/13/13
TAS Report Engineer of Record: Kevin P.Tyra, P.E.
Report# Report Date:
SJ W 2013-246 12/17/13
SJ W 2013-231 12/03/13
SJ W 2013-251 12/23/13
SJ W 2013-252 12/23/13
SJ W 2013-253 12/23/13
SJ W 2014-032 04/22/14
SJ W 2014-073 06/26/14
SJ W 2014-077 06/27/14
SJ W 2014-072 06/27/14
SJ W 2014-080 07/03/14
TAS Report Engineer of Record: Robert H.Zeiders, P.E.
2. Quality Assurance Entity
National Accreditation&Management Institute
(FBC Organization#QUA1789)
Hermes F. Norero, P.E.
Florida No.73778
Page 3 of 4
BUILDING DROPS
A Perfect Solution in Every Drop! Date: 11/15/2017
Certificate of Authorization:29578 Report No: 4663.1
3. Component Material Testing of Dylite Expandable Polystyrene by
Intertek Testing Services NA,Inc.
ASTM E84
Report#: 3113726SAT-001 R1 Report Date: 03/13/09
4. Component Material Testing of Fiberglass SMC Skin
Element Materials Technology
ASTM D635,ASTM D638,ASTM D1929,ASTM D2843,ASTM G155
Report#: ESP010982P Report Date:02/26/13
Installation: 1. Approved anchor types and substrates areas follows:
Through Frame Installation:
A. For two by(2X)wood buck substrate (Min.S.G.=0.55), use#10 Wood Screw type
installation anchors of sufficient length to achieve a minimum embedment of 1.50" into
B. For concrete(Min,f'c=3000 psi) or masonry(Conforms to ASTM C90)substrate where
one by(1X), non-structural, wood bucking is employed, use 3/16"diameter ITW Tapcon
or%"Elco Ultracon type concrete screw anchors of sufficient length to achieve minimum
embedment of 1.25" into concrete or masonry.
C. For concrete(Min.f c=3000 psi) or masonry(Conforms to ASTM C90) substrate where
wood bucking is NOT employed,use 3/16"diameter ITW Tapcon or%"Elco Ultracon
type concrete screw anchors of sufficient length to achieve minimum embedment of
1.25" into concrete or masonry.
Refer to Installation Instructions(A010871)for anchor spacing and more details of the installation
requirements.
Design Pressure:
MAX,OVERALL DESIGN PRESSURE(PSF)
NOMINAL 512E MISSILE
CONFIGURATION INSWING OUTSWING IMPACT
WIDTH HEIGHT RATING
POS, NEG. POS, NEG,
X 3'-0" 6'-8" 65' 65 65" 65 LMI &SMI
X 3'-0" 8'-0" 50 5(I 50" 50 LMI &SMI
Hermes F. Norero, P.E.
Florida No. 73778
Page 4 of 4