Loading...
HomeMy WebLinkAboutProduct Approval (2) ALIV 12 ao» �, � ��.` PnrRnitting Dep artment St,Lucie County BCiS Home Log In _ User Registration 1 Hot Topics Submit Surcharge ? Stats&Facts it Publications ; PBe Statf BCLs Site Map Links P Search ri d I. r i Product Approval USER:Public User Product Approval Menu>Product orAlpoiteatian5garch>.Aholication:List>Application.Detail FL# FL9777-RII Application Type Revision Code Version. ` 2017. Application Status Approved Comments, Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg:keeler@owenscoming.tom Authorized Signature Greg Keeler greg.keeler@owenscoming.com: Technical Representative Address/Phone/Email Fill ®�y Quality Assurance Representative Address/Phone/Email REVIEWED) /p0 Category Roofing CODE ®COMP 'pI��ANCE Subcategory Underiayments STa LUCIE�C{ OUN ®VC Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Englneer.or Architect Name who developed the Zachary R.Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date- 1 2/3 112 0 2 0 Validated By Locke Bowden Validation Checklist Hardcopy Received Certificate of Independence FL9777 R11 COI OCR14002 8a 2017 FBC Evaluation n Report Weatherlock. Non-HVHZ:pdf Referenced Standard and Year(of Standard) Standard Year -ASTM D 1970 2015 ASTM D 226 2009 ASTM G 155 2005 TAS 103 1995 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 1.0/11/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description _ 9777.1 WeatherLock G Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No FL9777 1111. II OCR14402 8a 2017 FBC Evaluation Regort Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ,odf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL M R11 AE OCR14002 8a 2017 FBC Evaluation Report Weatherlock Nan-HVHZ ndf Created by Independent Third Party:Yes 9777.2 Weather Lock G(High Tear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No F 777 R11 IIR11 II OCR14002 8a 2017 FBC Evaluation wPA Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.odf Impact Resistant: N/A Verified By: Zachary R.Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports PLO 77 R11 AE OCR14002 8a 2017 FBC Evaluation Report Weatherlock Nan-HVHZ pdf Created by Independent Third.Party:Yes 9777.3 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes FI 9777 R11 II OC914002 8b 2017 FBC Evaluation Rem, Approved for use outside HVHZ:No Weatherlock HVHZ.odf Impact Resistant:N/A Verified By:Zachary.R. Priest 74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9717 R11 AE OCR14002 8b 2017 FgC Evaluation Report Weatherlock HVHZ.adf' Created by Independent Third Party:Yes 9777.4 Weatherlock MAT Waterproofing Underlayment Limits of Use _ Installation Instructions Approved for use.in HVHZ:No FL9777 Rii II OCR14002 8a 2017 E0C Evaluation Report Approved for use-outside HVHZ:Yes Weatherlock Non-HVHZ.odf Impact Resistant:NIA Verified By: Zachary.R. Priest 74021 Design'Pressure:N/A Created by Independent Third Party:Yes. Other:See evaluation report for limits of use. Evaluation Reports 119777 1111 AE 117 FBC Evaluation Report WeatherLock Non-HVHZ.pdf Created by Independent Third Party:Yes 9777.5 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions i Approved for use in HVHZ:No F1:9777 1111 II OCR1$QQ a 2017 FBC Evaluation Refit Approved for use outside HVHZ:Yes Weatherlock Nan-HVHZ odf I Impact Resistant:N/A Verified By:Zachary R. Priest PE-74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports F19777 R11 AE OCRI4002.8a 2017,FBQ Evaluation Report Weatherlock Non-HVHZ pdf Created by Independent Third Party:Yes 19777.6 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:Yes 19777 R11 II OCR14002 8b 2017 FBC Evaluation R M t 'Approved for use outside HVHZi No Weatherlock HVHZ.pdf Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCRI4002,8b 2017 FBC Evaluation Report Weathercock HVHZ,pdf Created by Independent Third Party:Yes, .. 9777.7 _ WeatherLock Specialty Tile&Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R11 II OCR14002,8a 2017 FBC:Evaluation Report Approved for use outside HVHZ:Yes Weathercock Non-HVHZ.adf Impact Resistant:N/A Verified By:Zachary R.Priest 74021 Design Pressure: +0/-142.5 Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports F_L9777 R11 AE OCR14002.8a 2017 BC Evaluation Report Weathercock Non-HVHZ:Ddf Created by Independent Third Party:Yes r ITack NeXt Contact Us::2601 Stair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer,Copyright 2007 20t3 State of Florida ::Privacy Statement::Accessibility statement::Refund statemenS Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic . mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact850.487.1395,-Pursuant to Section 455.Z75(1),Florida-Statutes;effective,October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses ate public record,If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under chapter 455,F.S., please dick here Product Approval Accepts: Certificate of Authorization No. 29824 3` R E E K 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813.)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,r EDITION(2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017 1 Owens Corning Parkway Toledo,OH 43657 (800)438-7465 www.owenscorning.com i Manufacturing Location: Brentwood,NH Houston,TX Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES Enti Report No. Standard Year PRI Construction Materials Technologies(TST5878) NEI-039-02-01 ASTM D 1970 2015 PRI,Construction Materials Technologies(TST5878) NEI-042-02-01 REV2 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) NEI-093-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST5878) 0CF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST5878) OCF-252-02 01 ASTM D 4798 2001 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 ICC-ES AC 48 2012 PRI Construction Materials Technologies(TST5878) OCF-297-02-01.1 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-3,18-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies(TST5878) OCF-320-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST5878) OCF-321-02-01 ASTM D 1623 2009 PRI.Construction Materials Technologies(TST5878) OCF-322-02-01 UL 1897 2012 PRI Construction Materials Technologies(TST5878) OCF-355-02-01 UL 1897 2012 'Determined to be equivalent to ASTM D 226-09,Type I and If OCR14002,8a F1-9777-R11 Page 1 of 4 This evaluation report is provided for State of Florida,product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Servicesi LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product allributes that are not specifically addressed'herein. CREEK OWENS.CORNING ROOFING AND ASPHALT LLC WeatherLock®Self-Sealing Ice&Water Barriers TECHNICALSERVICEs,LLC PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock@ G WeatherLock®G is an ASTM D 1970 self-adhesive undedayment constructed from SBS (Brentwood,NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ G is permitted to be used.as prescribed in FBC Section 1607.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@)Mat WeatherLock@) Mat is an ASTM D 1970 self-adhesive underlaymert constructed from (Brentwood,NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, TX) sq.rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof'deck shall be limited to a maximum 30 days. WeatherLock@ Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood,NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLockO Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically-attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile&Metal constructed from SBS modified,asphalt and surfaced with a non-woven polyester fabric. (Brentwood,NH or The product is supplied in 2.14 sq.rolls.with nominal dimensions of 3-ft x 71.3-ft. Houston, 7X) WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be.used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.)or TILE BOWm Roof Tile Adhesive.(The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock@)G(High WeatherLock@ G(High Tear)is a self-adhered;underlayment used as an alternative to Tear) ASTM D 226,Type I or Type II roofing felt and ASTM D 1970 self-adhering polymer (Houston, 7X) modified bitumen underlayment. The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. Weatherl-ockO G (High Tear) is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings: Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.8a FL9777-R11 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report-does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK OWENS CORNING ROOFING AND ASPHALT LLC WeatFierLock@ Self-Sealing Ice&Water Barriers TECHNICAL SERVICES,LLC PRODUCT APPLICATION Min.Roof Slope: 2:12 in accordance with the FBC Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and connected prior to undedayment application. Prior to beginning installation, the undedayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The undedayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck.The undedayment shall be installed with the roll length parallel to the eave, starting at the eaves and with minimum:3"side laps and minimum 6"end laps staggered min.6-ft.from preceding course: Additionally,if applying WeatherLock@)Specialty Tile& Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to back nail the underayment 12=inches on-center as needed(nails shall be installed perpendicular to deck with the nail heads flush to the-top surface of the undedayment). Additionally,WeatherLock@ Specialty Tile& Metal shall be back nailed' when installed on roof slopes greater than 3:12. Min.Application 40°F;Contact the manufacturer when installing at temperatures below the minimum Temperature: application.temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. UnderlayMenf System No.1—WeatherLock Specialty Tile&Metal Oniv Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Undedayment: WeatherLock@) Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied underayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.8a. FL9777-Rl l Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CCREEKL"" u OWENS CORNING ROOFING AND ASPHALT LLC i�Gq i�. WeatherLock@)Self-Sealing Ice&Water Barriers TECHNICAL SERVICES;LLC GENERAL LIMI xnolsis 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. '3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck.area shall be property ventilated in accordance with the FBC requirements. '6) All side lap.seams.shall be installed to shed water from the deck. '7) The underlayment may be used as described in.other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others-in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum .Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly, 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6 h Edition(2017)as.evidenced in the referenced documents submitted by the named manufacturer. w'C E ni si!sj'' K..._ 2017.1.0.11 No 74021 ;.* 09:06-929 ir.. -04'00' STATE OF 1 04 i ,�•.•Al Q.,:`y�` Zachary R.Priest,P.E. r'� s• C R t'D N1 Florida Registration No.74021 W�� Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any-company manufacturing or distributing products under this evaluation. Zachary R. Priest,P.E.does not have,nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product END OF REPORT OCR14002.8a FL9777-R11 Page 4 of 4 This.evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report.is valid. This evaluation report does not express nor imply warranty;installation,recommended use, or other product attributes that are not specifically addressed herein.