Loading...
HomeMy WebLinkAboutNotice of Acceptance I I MIAMI-DARE NEL& II—DARE COUNTY ® PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Regency Plus,Inc. 2000'Locust Gap Highway Mount Carmel,PA 17851 SCOPE: This NOA is being issued under the applicable rules.and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone. DESCRIPTION: Series"5108"White PVC Fixed Window-L.M.I. APPROVAL DOCUMENT:Drawing No.RPLS0060,titled"Impact 5108 Series Fixed Window"sheets 1 through 5 of 5, dated 09/16/08, with revision G dated 01/08/18, prepared by PTC Product Design Group, LLC, signed and sealed by Robert J. Amoruso, P.E., bearing the Miami-Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 18-0122.10 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No.18-0918.03 MIAMMADE COUNTY Expiration Date: January 28,2020 Approval Date: October 11,2018 I®+4[lop Page 1 Regency Plus,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED i 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 08 1021.04) 2. Drawing No. RPLS0060, titled"Impact 5108 Series Fixed Window" sheets 1 through 5 of 5, dated 09/16/08, with revision G dated 01/08/18, prepared by PTC Product Design Group, LLC, signed and sealed by Robert J. Amoruso,P.E. (Submitted under previous NOA No. 18-012Z 10) B. TESTS 1. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1. and TAS 202-94 along with marked-up drawings and installation diagram of a series 5108 white PVC fixed window, prepared by National Certified Testing Laboratories, Inc., Test Report No. NCTL-110-11363-1,dated 05/15/08, signed and sealed by Harold E. Rupp,P.E. (Submitted under NOA No. 08-1021.04) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 51h Edition (2014), dated 06/11/15 with revision dated 09/01/15, prepared by PTC Product Design Group, LLC, signed and sealed by Robert J.Amoruso,P.E. (Submitted under NOA No. 15-0618.01) 2. Glazing complies with ASTM E1300-04 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America,Inc.for their "Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers"dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 16-0712.03,issued to ENERGI Fenestration Solutions USA,Inc., for their White Rigid PVC Exterior Extrusions for Windows and Doors,approved on 08/10/17, expiring on 02/28118. Manue er ,P.E. Product Cont I E miner NOA No. -0918.03 Expiration Date: January 28,2020 Approval Date: October 11,2018 E-1 Regency Plus,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance,complying with FBC 61h Edition (2017), dated January 8, 2018,prepared by PTC Product Design Group, LLC, signed and sealed by Robert J. Amoruso,P.E. (Submitted under previous NOA No. 18-0122.10) 2. Laboratory compliance letters for Test Report No. NCTIr110-11363-1, dated 05/15/08, issued by National Certified Testing Laboratories, Inc., signed and sealed by Harold E. Rupp,P.E. (Submitted under NOA No. 08-1021.04) G. OTHERS 1. Notice of Acceptance No. 15-0618.01, issued to Regency'Plus, Inc. for their Series "5108" White PVC Fixed Window — L.M.I., approved on 10/01/15 and expiring on 01/28/19. Manuel a z,P.E. Product Contr 1 Eyaminer NOA No. -0918.03 Expiration Date: January 28,2020 Approval Date: October 11,2018 E-2 Regency Plus,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. None B. TESTS 1. None C. CALCULATIONS 1. None D. QUALITY ASSURANCE .1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America,Inc.for their "Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers"dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 18-0122.02,issued to ENERGI Fenestration Solutions USA,Inc.,for their White Rigid PVC Exterior Extrusions for Windows and Doors,approved on 03/08/18, expiring on 02/28/23. F. STATEMENTS 1. Letter from manufacturer requesting a 1-year extension to allow time to perform verification test, dated 06/11/18, signed by Tony Procopio, Plant Manager. 2. Testing agreement letter, dated 06/12/18 between National Certified Testing Laboratories(NCTL)and Regency Plus, Inc.,issued by NCTL and signed by Justin L. Bupp, Laboratory Manager. G. OTHERS 1. Notice of Acceptance No. 18-0122.10,issued to Regency Plus, Inc. for their Series "5108"White PVC Fixed Window—L.M.I., approved on 03/08/18 and expiring on 01/28/19. 2. This is a one year approval, subjected to successful verification test. E f i 1 Manuel P ez, E. Product Control xam' er ! NOA No. 18- 8.03 Expiration Date: January 28,2020 Approval Date: October 11,2018 E-3 P, P, ®I. ® N ® Q ® �Nz m lull -u 8 mfm � m�m imyBUM �i, l p. PIE M � H egg og. l n MIN� �® oD ��2y0A• i MR �AA m N n Nyy 1aN Up ia3�3 On gh�i g.>>9 N. Ne-g1Q�Sis In��ey z nI N. -*--R2n2•u[- 11WmLN SDFIg1J�J1 Apt m S •Caa y29D wC HE C Zti.� nmpF m m m m m zP oa v Q� IN8 m 8m H g fi 8g 4 03' mKS F � cmoPi 'o ; b A 2t F m mu in lz�lN 20 o rg ��uuunrgr ° ;'� m6'm �..•""'•'••.B REGENCY PLUS,ING $ a �Gj'�.• Fri PROJECT 0417A607 g n.•y.�>1 N ,9�;. 2006 LOCUST OAP NIONWAY 8 •� �O� p�•;�r' � MT.CARMEL PA 17851 T MPAOT6166 SERIES ALLA71 NOTES&W m GENERAL NOTES,INSTALLATION NOTES 8 D.P.CHART tl m••9 T N�: P 8809l16/08 UPDATETOOTH M.T.S. mn RPLS0660 O E (7 7FBC V6116 JAG . i OF 6 i i I � a App B Eapp F 3 3 3 4 4 H 4 4 4 �m 3 4 4 w r� o �R D D 3 3 �w C HtC o § 3 3 A B E F y o03 ELEVATIONp w� 2 MAX.UNIT WIDTH 60' MAX.UNIT WIDTH 60' u z aq a D.LO WIDTH S41/E' D.LO WIDTH 54 11" 6'MAX.FROM CORNERS CTYP) 6'MAX.FROM CORNERS CTYP) 8'MAX.O.C.SPACING(TYP) ¢- B'MAX O.C.SPACING(TYP) a w 6'MAX.FROM 6'MAX FROM CORNERS(TYP) CORNERS CTYP) � ¢ W MAX O.C.SPACING(IYP) 6'MAX O.C.SPACING CTYP) g S RnOvt J.Nva,m.PF. FbM PE--I INSTALLATION—/ f i m0l"t......I ANCHOR(TYP) MAX UNIT MAX UNIT �Qt�pENs�.pp� HEIGHT HEIGHT 10'MAX O.C. ..P PARTING STOP SPACING(TYP) HE GHT B. HEI 60' _ No 4s752 :o HT ANCHOR(TYP.) 5410 INSTALLATION 641/2' 41/4'MAX FROM / ANCHOR(IYP.) / '0:: STAA OF :Yra CORNER I 6. I I I I 4'�3SfONA�E�tt�� 1/4'� I I I 10'MAX.O.C. j CORNER(TYP) ���"'11I11 ttt"'��� FFY "`ttt"'SPACING(rYP) y� yC4 ypyym ODUCrrtehSM ANCHOR LAYOUT ANCHOR LAYOUT a,evgacex p,/8-oen b .r�mnnr 18-fi918. 3 � PARTING STOP INSTALLATION OPTIONALINSTALTATION EXTPRIORVIEW EXTERIORVIEW Atwy�PN.n r1-;.JE i , NB'MIN.EDGE DISTANCE 1/4'MAX SHIM 2X WOOD FRAME @12 WOOD SCREW 1 1/2'MIN.EMBEDMENT � 2 BY OTHERS INSTALLATION ANCHOR 2X WOOD FHAME SHEATHING BYOTHERS By OTHERS EXTERIOR FINISH 1BE PIZ p BYOTHERS EMBEDMEM 912WOODSCREW 1 2 INSTALLATION ANCHOR � Q•" G �c 1 jw PERIMETER CAULK 114•IIAX SHIM 1 BY OTHERS 2 INTERIOR 3 �7/B'MIK 5 4 EDGE DISTANCE z S EXTERIOR SEE GLAZING DETAIL 1 a 0 ON THIS SHEET SHEATHING BY OTHERS 5 6 .¢•'o AL SECTION B p a EXTERIOR FINISH < .0 Tp D FRAMfB SUBSTRATE BY OTHERS PERIMETER CAULK S 1 3 BYOTHERS f p Bnam z 9 MAX OA FRAME WIDT 4 H i w 0.57 GLASS C1 HORIZONTAL SECTION w y q SITE OPTIONAL IN 6N__ o O tO 0 MAX.!OA WOOD FAAAfE SUBS'MTE FRAMEHEIGHT 5 S 8 a � 2 § 7/B'OA INSULATING GLASS CONSISTING OR I I 1/S'ANNEALED GLASS,0.090'TROSIFOL INTERLAVER 1/4'MAX.SHIM ®% WC.,119'ANNEAL GLASS, 1 W MIN.EMBEDMENT-CONCRETE BY KURARAY AMERICA $g 0.39'AIRSPACE,IB'INiERIOR TEMPERED ED GLASS i•MIN.EMBEDMENT-MASONRY GLAZING DETAIL 1 CONCRETE/MASONRY = a g a }L�SY OTHERS B 4 3 2 1 _ Rmertl,xmm,p.E •'�_� 1/4'ITWADVTHRFMTAPC0N Ro,tle l'E Ha 4I5i EXTERIOR -. INSTALLATION ANCHOR PERIMETERCAULK 3 ,.^�' ® 0v?.�•�cEEtiogG BY OTHERS 2 •' l li 4�= No 49752 t� EXTERIOR FINISH 1 1/4'MAX SHUT -`�r;112'MR4.EDGE DISTANCE CONCRETE *. BY OTHERS •1..,;fit 2'MW.EDGE DISTANCE-MASONRY 11b. 9TAT l F 1X WOOD BUCK •- MIK �,�•;n. .?�.. ( p:? BY OTHERS .?:'.i?.:.:'.. EMBEDMENT® 8 5 �i�tl'S'• O R��. p�,�� 13OLATIDN MATERIAL -_•� `\ BY OTHERS CK BETWEEN WOOD BUCK S `CONCRETEBY OTHER3 PERIMETER CAULK BY OTHERS BOTHERS ® (SEE NOTE 4,SHT.1) EXTERIORFINISH BY OTHERS ISOLATION MATERIAL BETWEEN WOOD 1/4'ITW ADV THRFM TAPCON ® BUCK B CONCRETE/MASONRY BY OTHERS WUCI REV13m pp112-MIN.EDGE DISTANCE INSTALLATION ANCHOR Ly —MAX. FRAME WIDTH e.0fl0:Ttu.Ne� VERTICAL SECTION A ova :x ua�ih ° ��IHDI9�.In,. HORIZONTAL SECTION arF.6r."` OPTlONALINSTALLAITON a<c:aaexn •091 3 1 NFRONAL WSTALLABST 6•'ssk Cate OONCRETE SUBSTRATE �/CONCRETE/MASONRY SIDISIRAIE � sa D.e&N i a4i{x .�c liNrdt• t i I i112 WOOD SCREW b 7/8'MIN.EDGE DISTANCE INSTALLATION ANCHOR ZX WOOD FRAME 1/4'MAX SHIM StgATHWG­TH 1X WOOD BUCK 11PP MIN.EMBEDMENT BY OTHERS BY OTHERS 6 EXTERIOR FINISH I 2X WOOD FRAME U BY OTHERS. BV OTHERS 1 12'MIN. 7 2 3 4 G o� 7 EMBEDMENT A72 WOOD SCREW w g 1/4'MAXSHIM INSTALLATION ANCHOR PERIMETER CAULK 7 7M'MIN. Fo I BY OTHERS 1 EDGE DISTANCE � 1 2 L j 6 3 y g 4 INTERIOR 6 7 5 6 p aid e EXTERIOR SEE GLAZING DETAIL 1 SHEATHING BY OTHER 6 g=S c rc ON SHEET 3 VERTICAL SECTION EXTERIOR FINISH a r 3 F PARTING STOP INSTATd.ATION BY OTHERS WOOD FRAME SUBSTRATE PERMLTERCAULK W s�xg $m O BY OTHERS MAX CA FRAME WIDTH- J w_U F HORIZONTAL SECTION N 4 PARTA'G STOP STA�AT10N y 6' MAX O.A. WOOD FRAME SUBSTRATE U�9cir HEIGHTFRAME a ¢> ll4'MAXSHIM �� 1 I I/L'MIN EMBEDMENT-CONC.® p 1'MN.EMBEDMENT-MASONRY 41W o I NCRETFJ MASONRY CO s g e ''• �BromERs s / 4 3 2 1 7 1/4'fRN ADVTHRFM TAPCON 4 INTERIOR i''. INSTALLATION ANCHOR EXTERIOR 3 =• ;:TAMES rr• PERIMETER CAULK J 2 1XWOODBUCK A `�4.4:•��0 ENBY EXTERIOR FINISH 1 BY DINERS _ 6& Q�'•TH No 4975 71f4'MAX SMM -•'112'MPL EDGE DISTANCE-GONG. BY OTHERS :2'MIN.EDGE DISTANCE-MASONRY 6 6 �, STATE OF ;�Lp ISOLATION MATERIAL 112'MIN. 6 (. 1XWOODBUCK y�'S•......•'tN` \ ONALE.�` BETWEEN WOOD BUCK& -•\ EMBEDMENT ® BY OTHERS ianrrutl PERIMETER CAULK BY OTHERS 6 CONCRETE/MASONRY CONCRETE BY OTHERS BY OTHERS (SEENOTE4•SHT•1) EXTERIOR FINISH BY OTHERS ISOLATION MATERIAL BETWEEN WOOD 1/4'TTW ADV THRFM TAPCON ® BUCK&CONCRETE/MASONRY BY OTHERS PRoDuCT Rcw1 n 1I112'MIN.EDGE DISTANCE INSTALLATION ANCHOR -MAX DA FRAME WIDTH 1g13UT7 D.iR31M1'it� gw.�Nri®wIp�Tl.rNv ® aacnurLwsa9,a,d m.bi D.IUmry �E1 VERTICAL SECTION , .H.l ro PARTING STOP LNYIALL.ATION HORIZONTAL SECTION PARMNGSTOP INSTALLATION ,[ CONCRETE SUBSTRATE CONCRETE/MASONRY SUBSTRATE t Q MAIN FRAME Q FRAME COVER 0 POCKET INSERT ® GLASS STOP d 0.070"TYPICAL WALL THICKNESS 0.070'TYPICAL WALL THICKNESS 0.070"TYPICAL WALL THICKNESS 0.070"TYPICAL WALL THICKNESS � a OstT 1A31• .�i Q7rr5P TTT oo K �9T50•-+•II I I O O U ©PARTING STOP SYM# PART# DESCRIPTION MATERIAL MANUFACTURER ® a 1 IV-1060 MAIN FRAME WHITE RIGID PVC ••EFS 2 IV-1070 FRAME COVER WHITE RIGID PVC "EFS "EFS:ENERGI B 3 FENESTRATION ¢ � (L7W+I Imo— ® 3 N-1079 POCKET INSERT WHITE RIGID PVC "'EFS SOLUTIONS USA, z q ®I A 4 IVAID3 GLASS STOP WHITE RIGID PVC =EFS INC.,PER CURRENT q=a gg m 5 IV-1070 SIKA FLEX 652 SILICONE BACK BEDDING SILICONE SIKA MD NOA. a $ 8 718'OA INSULATING GLASS CONSISTING OF: ® GLASS >F w. 1/8"INTERIOR TEMPERED GLASS,0.39"AIR SPACE, z ya 12 i V8'ANNEALED GLASS,0.090'TROSIFOL INTERLAYER u o mo y g BY KURARAY AMERICA,INC.,1/8"ANNEALED GLASS c w� a 7 — 1 12'X 3/4"PARTING STOP WOOD 6 ® 8 — 1518' SCREWWOOD INST CH ) STEEL — g 1os ® 9 — ENDUR9.8SSSPACER STAINLESS STL CARDINAL ��E j ILt 0 10 2NB-BK-125-028-026 GLAZING PAD SETTING BLOCK) NEOPRENE FRANK LOWE 'sepe I i 8 ) —J.A*m+ M fldea P.E-1 I . 2 IIIIIIIIIII �Qt�cEEruS _ N.49752 •o STATE OF --'W v.w.�yi su e✓teBisit� � ........ IVA!i ,a ; ! ��.Neee MJ •O9 E.6� 1 a i✓ � nb b-DY221c 3 r 9 ACORNER SECTION i