Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutNotice of Acceptance I
I
MIAMI-DARE NEL& II—DARE COUNTY
® PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Regency Plus,Inc.
2000'Locust Gap Highway
Mount Carmel,PA 17851
SCOPE:
This NOA is being issued under the applicable rules.and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control
Section(In Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code,including the High Velocity Hurricane Zone.
DESCRIPTION: Series"5108"White PVC Fixed Window-L.M.I.
APPROVAL DOCUMENT:Drawing No.RPLS0060,titled"Impact 5108 Series Fixed Window"sheets 1
through 5 of 5, dated 09/16/08, with revision G dated 01/08/18, prepared by PTC Product Design Group,
LLC, signed and sealed by Robert J. Amoruso, P.E., bearing the Miami-Dade County Product Control
Renewal stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County
Product Control Section.
MISSILE IMPACT RATING:Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 18-0122.10 and consists of this page 1 and evidence pages E-1, E-2 and E-3,
as well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez,P.E.
NOA No.18-0918.03
MIAMMADE COUNTY Expiration Date: January 28,2020
Approval Date: October 11,2018
I®+4[lop Page 1
Regency Plus,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
i
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA No. 08 1021.04)
2. Drawing No. RPLS0060, titled"Impact 5108 Series Fixed Window" sheets 1 through
5 of 5, dated 09/16/08, with revision G dated 01/08/18, prepared by PTC Product
Design Group, LLC, signed and sealed by Robert J. Amoruso,P.E.
(Submitted under previous NOA No. 18-012Z 10)
B. TESTS
1. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94
2)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94
3) Water Resistance Test,per FBC, TAS 202-94
4)Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC,TAS 203-94
6)Forced Entry Test,per FBC 2411.3.2.1. and TAS 202-94
along with marked-up drawings and installation diagram of a series 5108 white PVC
fixed window, prepared by National Certified Testing Laboratories, Inc., Test Report
No. NCTL-110-11363-1,dated 05/15/08, signed and sealed by Harold E. Rupp,P.E.
(Submitted under NOA No. 08-1021.04)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 51h
Edition (2014), dated 06/11/15 with revision dated 09/01/15, prepared by PTC
Product Design Group, LLC, signed and sealed by Robert J.Amoruso,P.E.
(Submitted under NOA No. 15-0618.01)
2. Glazing complies with ASTM E1300-04
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America,Inc.for their
"Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers"dated 01/18/18,
expiring on 07/08/19.
2. Notice of Acceptance No. 16-0712.03,issued to ENERGI Fenestration Solutions
USA,Inc., for their White Rigid PVC Exterior Extrusions for Windows and
Doors,approved on 08/10/17, expiring on 02/28118.
Manue er ,P.E.
Product Cont I E miner
NOA No. -0918.03
Expiration Date: January 28,2020
Approval Date: October 11,2018
E-1
Regency Plus,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS
1. Statement letter of conformance,complying with FBC 61h Edition (2017), dated January
8, 2018,prepared by PTC Product Design Group, LLC, signed and sealed by Robert J.
Amoruso,P.E.
(Submitted under previous NOA No. 18-0122.10)
2. Laboratory compliance letters for Test Report No. NCTIr110-11363-1, dated
05/15/08, issued by National Certified Testing Laboratories, Inc., signed and sealed by
Harold E. Rupp,P.E.
(Submitted under NOA No. 08-1021.04)
G. OTHERS
1. Notice of Acceptance No. 15-0618.01, issued to Regency'Plus, Inc. for their Series
"5108" White PVC Fixed Window — L.M.I., approved on 10/01/15 and expiring on
01/28/19.
Manuel a z,P.E.
Product Contr 1 Eyaminer
NOA No. -0918.03
Expiration Date: January 28,2020
Approval Date: October 11,2018
E-2
Regency Plus,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. None
B. TESTS
1. None
C. CALCULATIONS
1. None
D. QUALITY ASSURANCE
.1. Miami-Dade Department of Regulatory and Economic Resources(RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America,Inc.for their
"Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers"dated 01/18/18,
expiring on 07/08/19.
2. Notice of Acceptance No. 18-0122.02,issued to ENERGI Fenestration Solutions
USA,Inc.,for their White Rigid PVC Exterior Extrusions for Windows and
Doors,approved on 03/08/18, expiring on 02/28/23.
F. STATEMENTS
1. Letter from manufacturer requesting a 1-year extension to allow time to perform
verification test, dated 06/11/18, signed by Tony Procopio, Plant Manager.
2. Testing agreement letter, dated 06/12/18 between National Certified Testing
Laboratories(NCTL)and Regency Plus, Inc.,issued by NCTL and signed by Justin L.
Bupp, Laboratory Manager.
G. OTHERS
1. Notice of Acceptance No. 18-0122.10,issued to Regency Plus, Inc. for their Series
"5108"White PVC Fixed Window—L.M.I., approved on 03/08/18 and expiring on
01/28/19.
2. This is a one year approval, subjected to successful verification test.
E
f
i
1
Manuel P ez, E.
Product Control xam' er !
NOA No. 18- 8.03
Expiration Date: January 28,2020
Approval Date: October 11,2018
E-3
P, P, ®I. ® N ® Q
® �Nz m lull -u 8 mfm � m�m imyBUM
�i, l
p.
PIE
M �
H egg og. l n
MIN�
�® oD ��2y0A• i
MR
�AA m N n Nyy
1aN Up ia3�3 On gh�i g.>>9 N. Ne-g1Q�Sis In��ey
z nI N. -*--R2n2•u[- 11WmLN SDFIg1J�J1 Apt
m S •Caa y29D wC HE C Zti.� nmpF
m m m m m zP oa v
Q� IN8 m 8m H
g fi 8g 4
03' mKS F � cmoPi 'o ; b
A
2t
F m
mu in
lz�lN 20
o rg
��uuunrgr °
;'� m6'm �..•""'•'••.B REGENCY PLUS,ING
$ a �Gj'�.• Fri PROJECT 0417A607
g n.•y.�>1 N ,9�;. 2006 LOCUST OAP NIONWAY
8 •� �O� p�•;�r' � MT.CARMEL PA 17851
T
MPAOT6166 SERIES ALLA71 NOTES&W
m GENERAL NOTES,INSTALLATION NOTES 8 D.P.CHART
tl m••9 T N�: P 8809l16/08
UPDATETOOTH
M.T.S. mn RPLS0660 O E (7 7FBC V6116 JAG . i OF 6
i
i
I
� a
App B Eapp F 3
3 3 4 4
H 4
4 4 �m 3
4 4 w
r�
o �R
D D
3 3 �w
C
HtC o §
3 3
A B E F y o03
ELEVATIONp
w� 2
MAX.UNIT WIDTH 60' MAX.UNIT WIDTH 60' u z
aq a
D.LO WIDTH S41/E' D.LO WIDTH 54 11"
6'MAX.FROM CORNERS CTYP) 6'MAX.FROM CORNERS CTYP)
8'MAX.O.C.SPACING(TYP) ¢-
B'MAX O.C.SPACING(TYP) a w
6'MAX.FROM 6'MAX FROM
CORNERS(TYP) CORNERS CTYP) � ¢
W MAX O.C.SPACING(IYP) 6'MAX O.C.SPACING CTYP) g
S
RnOvt J.Nva,m.PF.
FbM PE--I
INSTALLATION—/ f i m0l"t......I
ANCHOR(TYP) MAX UNIT MAX UNIT �Qt�pENs�.pp�
HEIGHT HEIGHT
10'MAX O.C. ..P
PARTING STOP SPACING(TYP) HE GHT B. HEI 60' _ No 4s752 :o
HT
ANCHOR(TYP.) 5410 INSTALLATION 641/2'
41/4'MAX FROM / ANCHOR(IYP.) / '0:: STAA OF :Yra
CORNER
I 6.
I I I I 4'�3SfONA�E�tt��
1/4'� I I I 10'MAX.O.C. j
CORNER(TYP) ���"'11I11 ttt"'��� FFY "`ttt"'SPACING(rYP) y� yC4 ypyym ODUCrrtehSM
ANCHOR LAYOUT ANCHOR LAYOUT
a,evgacex p,/8-oen b
.r�mnnr 18-fi918. 3 �
PARTING STOP INSTALLATION OPTIONALINSTALTATION
EXTPRIORVIEW EXTERIORVIEW
Atwy�PN.n r1-;.JE
i
, NB'MIN.EDGE DISTANCE 1/4'MAX SHIM
2X WOOD FRAME @12 WOOD SCREW 1 1/2'MIN.EMBEDMENT � 2
BY OTHERS INSTALLATION ANCHOR
2X WOOD FHAME
SHEATHING
BYOTHERS
By
OTHERS
EXTERIOR FINISH 1BE PIZ p
BYOTHERS EMBEDMEM 912WOODSCREW 1 2
INSTALLATION ANCHOR � Q•" G
�c
1 jw
PERIMETER CAULK 114•IIAX SHIM 1
BY OTHERS 2 INTERIOR
3 �7/B'MIK
5 4 EDGE DISTANCE z
S
EXTERIOR SEE GLAZING DETAIL 1 a 0
ON THIS SHEET SHEATHING BY OTHERS 5 6 .¢•'o
AL SECTION
B p a EXTERIOR FINISH < .0
Tp D FRAMfB SUBSTRATE BY OTHERS PERIMETER CAULK S
1 3 BYOTHERS f p
Bnam z
9 MAX OA FRAME WIDT
4 H i w
0.57 GLASS
C1 HORIZONTAL SECTION w y q
SITE OPTIONAL IN 6N__ o O tO 0
MAX.!OA WOOD FAAAfE SUBS'MTE
FRAMEHEIGHT 5 S 8 a � 2 §
7/B'OA INSULATING GLASS CONSISTING OR I I
1/S'ANNEALED GLASS,0.090'TROSIFOL INTERLAVER 1/4'MAX.SHIM ®%
WC.,119'ANNEAL GLASS, 1 W MIN.EMBEDMENT-CONCRETE
BY KURARAY AMERICA $g
0.39'AIRSPACE,IB'INiERIOR TEMPERED ED GLASS i•MIN.EMBEDMENT-MASONRY
GLAZING DETAIL 1 CONCRETE/MASONRY = a g a
}L�SY OTHERS
B 4 3 2 1 _ Rmertl,xmm,p.E
•'�_� 1/4'ITWADVTHRFMTAPC0N Ro,tle l'E Ha 4I5i
EXTERIOR -. INSTALLATION ANCHOR
PERIMETERCAULK 3 ,.^�' ® 0v?.�•�cEEtiogG
BY OTHERS 2 •' l li 4�= No 49752 t�
EXTERIOR FINISH 1 1/4'MAX SHUT -`�r;112'MR4.EDGE DISTANCE CONCRETE *.
BY OTHERS •1..,;fit 2'MW.EDGE DISTANCE-MASONRY 11b.
9TAT l F
1X WOOD BUCK •- MIK �,�•;n.
.?�.. ( p:?
BY OTHERS .?:'.i?.:.:'.. EMBEDMENT® 8 5 �i�tl'S'• O R��. p�,��
13OLATIDN MATERIAL -_•� `\ BY OTHERS CK
BETWEEN WOOD BUCK S `CONCRETEBY OTHER3 PERIMETER CAULK BY OTHERS
BOTHERS ® (SEE NOTE 4,SHT.1) EXTERIORFINISH BY OTHERS ISOLATION MATERIAL BETWEEN WOOD
1/4'ITW ADV THRFM TAPCON ® BUCK B CONCRETE/MASONRY BY OTHERS WUCI REV13m
pp112-MIN.EDGE DISTANCE INSTALLATION ANCHOR
Ly —MAX. FRAME WIDTH e.0fl0:Ttu.Ne�
VERTICAL SECTION A ova :x ua�ih ° ��IHDI9�.In,. HORIZONTAL SECTION arF.6r."`
OPTlONALINSTALLAITON a<c:aaexn •091 3
1 NFRONAL WSTALLABST 6•'ssk Cate
OONCRETE SUBSTRATE �/CONCRETE/MASONRY SIDISIRAIE � sa D.e&N i
a4i{x .�c liNrdt•
t
i
I
i112 WOOD SCREW b
7/8'MIN.EDGE DISTANCE INSTALLATION ANCHOR
ZX WOOD FRAME
1/4'MAX SHIM
StgATHWGTH 1X WOOD BUCK 11PP MIN.EMBEDMENT
BY OTHERS BY OTHERS 6
EXTERIOR FINISH I 2X WOOD FRAME U
BY OTHERS.
BV OTHERS 1 12'MIN. 7 2 3 4 G o�
7 EMBEDMENT A72 WOOD SCREW w
g 1/4'MAXSHIM INSTALLATION ANCHOR
PERIMETER CAULK 7 7M'MIN. Fo I
BY OTHERS 1 EDGE DISTANCE � 1
2 L j
6 3 y
g
4 INTERIOR
6 7 5 6 p aid e
EXTERIOR SEE GLAZING DETAIL 1 SHEATHING BY OTHER 6 g=S c rc
ON SHEET 3
VERTICAL SECTION EXTERIOR FINISH a r 3
F PARTING STOP INSTATd.ATION BY OTHERS
WOOD FRAME SUBSTRATE PERMLTERCAULK W s�xg
$m O
BY OTHERS MAX CA FRAME WIDTH-
J w_U F
HORIZONTAL SECTION N 4
PARTA'G STOP STA�AT10N y 6'
MAX O.A. WOOD FRAME SUBSTRATE U�9cir
HEIGHTFRAME
a ¢>
ll4'MAXSHIM �� 1
I I/L'MIN EMBEDMENT-CONC.® p
1'MN.EMBEDMENT-MASONRY 41W
o I
NCRETFJ MASONRY CO s g
e ''• �BromERs
s /
4 3 2 1 7 1/4'fRN ADVTHRFM TAPCON
4 INTERIOR i''. INSTALLATION ANCHOR
EXTERIOR 3 =• ;:TAMES rr•
PERIMETER CAULK J 2 1XWOODBUCK A `�4.4:•��0 ENBY
EXTERIOR FINISH 1 BY DINERS _ 6& Q�'•TH
No 4975
71f4'MAX SMM -•'112'MPL EDGE DISTANCE-GONG.
BY OTHERS :2'MIN.EDGE DISTANCE-MASONRY
6 6 �, STATE OF ;�Lp
ISOLATION MATERIAL 112'MIN. 6 (. 1XWOODBUCK y�'S•......•'tN`
\ ONALE.�`
BETWEEN WOOD BUCK& -•\ EMBEDMENT ® BY OTHERS ianrrutl
PERIMETER CAULK BY OTHERS 6
CONCRETE/MASONRY CONCRETE BY OTHERS
BY OTHERS (SEENOTE4•SHT•1) EXTERIOR FINISH BY OTHERS ISOLATION MATERIAL BETWEEN WOOD
1/4'TTW ADV THRFM TAPCON ® BUCK&CONCRETE/MASONRY BY OTHERS PRoDuCT Rcw1 n
1I112'MIN.EDGE DISTANCE INSTALLATION ANCHOR -MAX DA FRAME WIDTH 1g13UT7 D.iR31M1'it� gw.�Nri®wIp�Tl.rNv
® aacnurLwsa9,a,d m.bi D.IUmry
�E1 VERTICAL SECTION , .H.l ro
PARTING STOP LNYIALL.ATION HORIZONTAL SECTION
PARMNGSTOP INSTALLATION ,[
CONCRETE SUBSTRATE CONCRETE/MASONRY SUBSTRATE
t
Q MAIN FRAME Q FRAME COVER 0 POCKET INSERT ® GLASS STOP d
0.070"TYPICAL WALL THICKNESS 0.070'TYPICAL WALL THICKNESS 0.070"TYPICAL WALL THICKNESS 0.070"TYPICAL WALL THICKNESS
� a
OstT 1A31• .�i Q7rr5P
TTT oo K
�9T50•-+•II I I O
O
U
©PARTING STOP SYM# PART# DESCRIPTION MATERIAL MANUFACTURER
® a 1 IV-1060 MAIN FRAME WHITE RIGID PVC ••EFS
2 IV-1070 FRAME COVER WHITE RIGID PVC "EFS "EFS:ENERGI B 3
FENESTRATION ¢ �
(L7W+I Imo— ® 3 N-1079 POCKET INSERT WHITE RIGID PVC "'EFS SOLUTIONS USA, z q
®I A 4 IVAID3 GLASS STOP WHITE RIGID PVC =EFS INC.,PER CURRENT q=a gg m
5 IV-1070 SIKA FLEX 652 SILICONE BACK BEDDING SILICONE SIKA MD NOA. a $
8 718'OA INSULATING GLASS CONSISTING OF: ® GLASS >F w.
1/8"INTERIOR TEMPERED GLASS,0.39"AIR SPACE, z ya 12 i
V8'ANNEALED GLASS,0.090'TROSIFOL INTERLAYER u o mo y g
BY KURARAY AMERICA,INC.,1/8"ANNEALED GLASS c w�
a 7 — 1 12'X 3/4"PARTING STOP WOOD 6
® 8 — 1518' SCREWWOOD INST CH ) STEEL — g 1os
® 9 — ENDUR9.8SSSPACER STAINLESS STL CARDINAL
��E j
ILt 0
10 2NB-BK-125-028-026 GLAZING PAD SETTING BLOCK) NEOPRENE FRANK LOWE
'sepe I i
8 )
—J.A*m+ M
fldea P.E-1 I .
2 IIIIIIIIIII
�Qt�cEEruS
_ N.49752 •o
STATE OF --'W
v.w.�yi su e✓teBisit� � ........
IVA!i ,a ; !
��.Neee MJ •O9 E.6� 1
a i✓ � nb b-DY221c
3 r 9
ACORNER SECTION