HomeMy WebLinkAboutProduct Approval lY
Business & Professional Regulation
SCIS Home l Log In l User Registration l Hot Topics Submit Surcharge Stats&Facts I Publications Contact Us I BCIS Site Map Links Search
Florida
;, 1 ` Product Approval
Cyt yyy USER:Public User
EueG/pvp�a�t�m„lem
Product Approval Menu>Product or Agplication Search>Application List>Application Detail
ONE • FL# FL5374-R5
Application Type Affirmation RECEIVED
Code Version 2017 y +�
Application Status Approved NOV 1 9 90ig,
Comments ST. Lucie County, Permitting
Archived O
Product Manufacturer —1 East Coast Metals,Inc.
Address/Phone/Email 1 71(( 2301 West 8 Lane
1 Hialeah,FL 33010
REVIEWED FOR avast 885-9991
(� n (� C R acastellanos@eastcoast-metals.com
AuthorizeQ nJt:ddrF COMPLIANCE
Tom Castellanos
ST. ® p ,CIE COUNTY acastellanos@eastcoast-metals.com
Technical Representative B0(0' Tom Castellanos
Address/Phone/Email 2301 West 8 Lane
/ y Hialeah,FL 33010
(305)885-9991
jj�f J ( ,� tcastellanos@eastcoast-metals.com
Quality Assurance Representative" ®p Howard Callender Jr.
Address/Phone/Email 2301 West 8 Lane
Hialeah, FL 33010
(305)885-9991
hcallender@eastcoast-metals.com
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Architectural Testing,Inc.,an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John W.Knezevich,PE
O Validation Checklist-Hardcopy Received
Certificate of Independence FL5374 R5 COI 2015 01 COI Nieminen.pd
Referenced Standard and Year(of Standard) Standard Year
FRSA/TRI April 2012(04-12) 2012
RAS 118 1995
RAS 119 1995
RAS 120 1995
SBCCI SSTD 11 1997
TAS 101 1995
Equivalence of Product Standards
Certified By
Sections from the Code
CI affirm that there are no changes in the new Florida Building
Code which affect my product(s)and my product(s)are in
compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity O Yes O No O N/A
FL5374 RS COC 2017 09 AFFIRMATION ECM FL5374 6th Edition
.(2017)-pdf
Product Approval Method Method 1 Option D
Date Submitted 09/06/2017
Date Validated 09/06/2017
Date Pending FBC Approval
Date Approved 09/10/2017
Summary of Products
FL# Model,Number or Name Description
5374.1 East Coast Metals Channel Metals Preformed metal channels designed for use as a hip&ridge
base to which roof tiles are bonded.
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL5374 R5 II 2015 03 FINAL ER ECM Trim Lock FL5374-
Approved for use outside HVHZ:Yes R4.pff
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-178 Created by Independent Third Party:Yes
Other: 1.) Refer to Evaluation Report Sections 5.2 and 5.3 for Evaluation Reports
Limits of Use in HVHZ and non-HVHZ jurisdictions,respectively. FL5374 RS AE 2015 03 FINAL ER ECM Trim Lock FL5374-
2.)The design pressure herein pertains to use in non-HVHZ R4.pdf
jurisdictions in conjunction with Table 1A of FRSA/TRI April Created by Independent Third Party: Yes
2012(04-12).Refer to Tables 2A and 2B in the Evaluation
Report for all options and associated allowable design
pressures.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
TR1NITY I 353 CHRISTIAN STREET, UNIT
ERD OXFORD,CT 06478478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
East Coast Metals,Inc. Evaluation Report E10240.08.08-R4
2301 West 8 Lane FL5374-114
Hialeah, FL 33010 Date of Issuance:09/03/2008
Revision 4:03/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition(2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M.Nieminen P.E. '�v� T:;� The facsimile seal appearing snotsas hoeasaned yRohertNieminen,
� �C+' '^ �,�.•'?-�� P.E.on 03/17/2015.This does not serve as an electronically signed
Florida Registration No.59166 Florida DCA ANE1983i�'`r�iplial�i``'• document.Signed,sealed hardcopies have been transmitted to the
;✓'Jli.....r , Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.3.7 Installation,non-HVHZ FRSA/TRI April 2012(04-12) 2012
1518.8.1 Installation,HVHZ RAS 118,119&120 1995
1523.6.5.2.2 Static Uplift Resistance TAS 101 1995
1711.2.1 Static Uplift Resistance SBCCI SSTD 11 1997
3. REFERENCES:
Eniiiy Examination Reference Date
ERD(TST6049) Static Uplift Resistance E42730.08.13 08/23/2013
ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015
ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015
Florida TEC(TST7393) TAS 101 S10-628R 10/27/2010
PRI(TST5878) TAS 101 ECM-001-02-01 09/21/2001
PRI(TST5878) TAS 101 ECM-003-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-004-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-006-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-007-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-008-02-01 06/13/2008
Florida Building Code Attachment Requirements FRSA/TRI April 2012(04-12) 04/2012
Florida Building Code-HVHZ Attachment Requirements RAS 118,119 and 120 1995
East Coast Metals Metal Quality Mill Certifications Various
Architectural Testing(QUA1844) Quality Control Participation Letter Exp.12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive.
Hip& Ridge Channel Metal is available in 119-3/8-inch (±
3/8-inch)length by 2.5,3,3.5,4,5,6 or 7-inch(±3/8-inch)
heights with 1.5-inch L 1/16-inch)deck-flanges.
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate ofAuthorization#9503 FLS374-R4
Revision 4:03/17/2015
Page 2 of 7
TRINITY I ERD
4.2 Trim Lock Channel Metal: Pre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (+ p
3/8") length by 3, 3.5,4, 5 or 6-inch (±3/8-inch) heights
with 1.5-inch(±1/16-inch)deck-flanges.
O
4.2 Trim Lock Plus Channel Metal: Pre-formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation o
atop the roof underlayment via placement in FBC g j
Approved roof tile adhesive, which flows-through and v j
interlocks with the underlying adhesive. o
O
Trim Lock Plus Channel Metal is available in 119-3/8-inch /
(±3/8")length by 3,3.5,4,5 or 6-inch L 3/8-inch)heights /
with 1.5-inch(±1/16-inch)deck-flanges.
0�
0 00
0
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min.0.019±0.002-inch,ASTM A653(G-90),min.33 KSI.
➢ Galvalume Steel: Min.0.019+0.002-inch,ASTM A792,AZ55,min.35 KSI.
➢ Aluminum: Min.0.032±0.002-inch,ASTM B209,3003-1-114,min.21 KSI.
➢ Stainless Steel: Min.0.019±0.002-inch,ASTM A240/A480,T304,min.35 KSI.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate of Authorization#9503 FL5374-114
Revision 4:03/17/2015
Page 3 of 7
TRINITY I ERD
5.2 FOR HVHZ JURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions,installations of Hip&Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120,and the data in Tables 1A and 16 is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance(Mr)or uplift resistance(Fr),
as determined in accordance with RAS 127,not greater than the following values.
Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own,single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for"INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
➢ "INTERDEPENDENT"paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for"INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE IA: PERFORMANCE LIMITATIONS-HVHZ,INDEPENDENT PADDY PLACEMENT
•(2 TO 1 MARGIN OF SAFETYALREADYAPPLIED)
Hip/Ridge Metal Adhesive Allowable Performance
Tile Moment Based Uplift Based
Design Metal Type Type Placement MI(ft-Ibf) F'(Ibf)
Hip&Ridge galvanized clay or 3M-2-Component Foam Independent 127 169
Channel Metal concrete Roof Tile Adhesive AH-160
Trim Lock galvanized,Galvalume®, clay or 31VITM'2-Component Foam Independent 171 159
aluminum or stainless steel concrete Roof Tile Adhesive AH-160
Trim Lock Plus galvanized,Galvalume", clay or 3M'"2-Component Foam Independent 177 165
aluminum or stainless steel concrete Roof Tile Adhesive AH-160
TABLE 18: PERFORMANCE LIMITATIONS-HVHZ,INTERDEPENDENT PADDY PLACEMENT
(4 TO Z MARGIN OF SAFETYALREADYAPPLIED)
Hip/Ridge Metal Adhesive Allowable Performance
Tile Moment Based Uplift Based
Design Metal Type Type Placement Mf(ft-Ibf) F'(Ibf)
Trim Lock or Trim galvanized,Galvalume". clay or 31VI'"2-Component Foam Interdependent 95 88
Lock Plus aluminum or stainless steel concrete Roof Tile Adhesive AH-160
Trim Lock galvanized,Galvalume", clay or 3Mm Roof Tile Adhesive Interdependent 99 94
stainless steel concrete RTA-1
Trim Lock aluminum clay or 3M'"Foam Roof Tile Interdependent 90 84
concrete Adhesive RTA-1
Trim Lock Plus galvanized,Galvalume", clay or 3M—Foam Roof Tile Interdependent 90 84
aluminum or stainless steel concrete Adhesive RTA-1
Trim Lock galvanized,Galvalume®or clay or TILE BOND'"Roof Tile Interdependent 123 117
stainless steel concrete Adhesive
Trim Lock aluminum clay or TILE BOND—Roof Tile Interdependent 79 73
concrete Adhesive
Trim Lock Plus galvanized,Galvalume®, clay or TILE BOND'"Roof Tile Interdependent 79 73
aluminum or stainless steel concrete Adhesive
Trim Lock galvanized,Galvalume®or clay or Touch'n Seal StormBond Interdependent 146 139
stainless steel concrete Roof Tile Adhesive
Trim Lock Aluminum clay or Touch'n Seal StormBond Interdependent 58 54
concrete Roof Tile Adhesive
Trim Lock Plus galvanized,Galvalume", clay or Touch'n Seal StormBond Interdependent 58 54
aluminum or stainless steel concrete Roof Tile Adhesive
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate of Authorization#9503 FL5374-R4
Revision 4:03/17/2015
Page 4 of 7
QOTRINrry I ERS
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip&Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal,refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own,single
foam paddy;tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for"INDEPENDENT"paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT"paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for"INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE 2A: PERFORMANCE LIMITATIONS—NON-HVHZ,INDEPENDENT PADDY PLACEMENT
(2 TO 1 MARGIN OF SAFETYALREADYAPPLIED)
Hip/Ridge Metal Tile Adhesive Allowable Uplift
Design Metal Type Type Placement (Psf)
Hip&Ridge galvanized clay or 3MT"'2-Component Foam Roof Independent 169
Channel Metal concrete Tile Adhesive AH-160
Trim Lock galvanized,Galvalume",aluminum or clay or 3MT"2-Component Foam Roof Independent 173
stainless steel concrete Tile Adhesive AH 160
Trim Lock Plus galvanized,Galvalume®,aluminum or clay or 3MT"'2-Component Foam Roof Independent 178
stainless steel concrete Tile Adhesive AH-160
TABLE 213: PERFORMANCE LIMITATIONS—NON-HVHZ,INTERDEPENDENT PADDY PLACEMENT
(4 TO MARGIN OF SAFETYALREADYAPPLIED)
Hip/Ridge Metal Tile Adhesive Allowable Uplift
Design Metal Type Type Placement (Psfl
Trim Lock or Trim galvanized,Galvalume®,aluminum or clay or 3MT"2-Component Foam Roof Interdependent 98
Lock Plus stainless steel concrete Tile Adhesive AH-160
Trim Lock galvanized,Galvalume®or stainless clay or 3MT"'Foam Roof Tile Adhesive Interdependent 110
steel concrete RTA-1
Trim Lock aluminum clay or 3MT"'Foam Roof Tile Adhesive Interdependent 93
concrete RTA-1
Trim Lock Plus galvanized,Galvalume",aluminum or clay or 310T""Foam Roof Tile Adhesive Interdependent 93
stainless steel concrete RTA-1
Trim Lack galvanized,Galvalume®or stainless clay or TILE BOND—Roof Tile Adhesive Interdependent 152
steel concrete
Trim Lock aluminum clay or TILE BOND—Roof Tile Adhesive Interdependent 82
concrete
Trim Lock Plus galvanized,Galvalume",aluminum or clay or TILE BOND"Roof Tile Adhesive Interdependent 82
stainless steel concrete
galvanized,Galvalume®or stainless clay or Touch'n Seal StormBond Roof
Trim Lock steel concrete Tile Adhesive Interdependent 148
Trim Lock Aluminum clay or Touch'n Seal StormBond Roof Interdependent 61
concrete Tile Adhesive
galvanized,Galvalume®,aluminum or clay or Touch'n Seal StormBond Roof
Trim Lock Plus stainless steel concrete Tile Adhesive Interdependent 61
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate of Authorization#9503 FL5374-R4
Revision 4:03/17/2015
Page 5 of 7
QOTRINITYIERD
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood(non-HVHZ)or minimum 19/32-inch plywood(HVHZ)attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip&Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga.x 1X-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck-flanges. Fasteners shall be
positioned%-inch from the outside edge of each deck-flange,set in a bed plastic roof cement. For FBC HVHZ,refer to
FBC RAS 118,Drawing 13,Detail 3;RAS 119,Drawing 12,Detail 3;or RAS 120,Drawing 15,Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
View of Polyset AH16O Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified '30/90'system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate ofAuthorization#9503 FL5374-R4
Revision 4:03/17/2015
Page 6 of 7
d • �
QO
TRINITY IERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved,published
installation instructions,subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118,RAS 119,RAS 120 requirements.
.... Hip/Ridge Tile
Tile Adhesive
Trim Lock Plus.
Mortar or Weather Block
+'.�'.: +•r'• ''t' Adhesive
..'i.. •.'i..
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust,debris,oils or other bond-breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing,Inc. —QUA1844;(717)764-7700
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report E10240.08.08-R4
Certificate of Authorization#9503 FL5374-114
Revision 4:03/17/2015
Page 7 of 7