NOTICE OF ACCEPTANCE (NOA) www.miamidade."Weconomy
Southeastern Metals Manufacturing Company,Inc.
11801 Industry Drive He (florr,
Jacksonville,FL 32218
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Weather Vent
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 13-0814.08 consists of pages I through 3.
The submitted documentation was reviewed by Freddy Semina
NOA No.:18-1212.10
Expiration Date: 04/15/24
APPROVED I Approval Date: 01131/19
Page 1 of 3
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Subcategory: VerMadon
Material: Steel .
Minimum Slope: 2:12
TRADE NAMES OR PRODUCTS AUNUFAC°PURED OR LABELED ED BY APPLICANT:
Manufactured by Test Product
an
AWMAOMSDeserlotion
Weather Vent Vent:4-W x 19"x 46" TAS 100 Galven_ized metal roof vent
DeckFlange:24"x 52"
Thickness:0.0217 inch.
MANUFACTURING LOCATION
1. Jacksonville,FL
EVIDENCE SUBMITTED
Test Agency Test Identfller Tet Namaftmwrt Dane
PRI Asphalt Technologies,Inc. TAS 100 SEM-0024"l 08/14/03
ICC-ES AC132 SEM.021.-02-01 01/07/14
APPROVED APPLICATIONS:
Deck Type: Wood
Deck Description: 1514,or grater Plywood or wood plank
System Type A; Mechanical attachment of vent
Cutout: Mark a 3W x 46"opening cenkoed,between layout lines and aligned minimum 6 inches from
the ridge. Set blade to thickness of sheathing and out opening. Brush away sawdust and debris.
Installation: Vents should be evenly spaced an the rear slope of the roofi
Center vent in opening and set it in a 1/8"thick of an approved ASTM D 4586 asphalt roofing
comenL Secure vent to the roof deck with 1-Y'galvanized ring shank roofing nails spaced
appurm ro.c.and 1"from the outside edge ofthe flange. Uae a minimum of 18 naffs per vent.
Seat all nalls and vent flange with an approved ASTM D 4586.roofin9 cement. (Sec drawings
herein),
Net Fee Area: 99 aquae inches.
NOANo.:1&12=10
Expiration Dates 04/15/24
Approval Date: 01131/19
Page 2 of 3
r
c t
IMMATIONS:
1. Refer to applicable building code for required ventilation
2. Weather Vent shall comply with the roanufactura's cunwA published application instructions and the
requirements set forth in the applicable building cede.
3. This acceptance is for installations
4. 'Weather Vent shall not be installed on roof mean heights greater than 33 feet.
S. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61620-3 of the Florida Administrat�ye Code,
6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of
the mane aaturer's name or logo,city,state,and following statement:'Mami-Dade County Product
Control Approved"or the Miami Dade County Product Control Seal as shown below:
.,
DRAWINGS
ROOF FLANGE
EXTERNAL WIND
BAFFLE
ROOF FLANGE NAILPLACEMEdT
END OF THIS ACCEPTANCE
I I I NOA Na:18-1212.10.
Exphsaon Dam 04/15/24
Approval Date: 01/31/19