Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
scan.SPEC.SHT.RINNAI.TANKLESS.LP.GAS.RL94i
• • Type of Appliance Rinnai Model Number Operation / Installation Minimum/Maximum Gas Rate (Input) Electrical Electrical Consumption Amperage Ignition System Hot Water Capacity Temperature Temperature (without remote) Installation Energy Factor Service Connections Isolation & Pressure Relief Valves Included • Temperature controlled, continuous flow, gas hot water system • Certified for installation in manufactured (mobile) homes • Forced combustion / Direct vent REU-VC2837FFUD-US Forced combustion; indoor only 10,300 - 199,000 BTU/h Appliance: AC 120 Volts - 60 Hz Controller: DC 12 Volts Normal: 97 w Standby: 2 w Anti -frost protection: 120 w Max with pump: 8A Max without pump: 4A Fuse: 10A Direct electronic ignition Minimum flow rate: 0.26 GPM (1 I/min) Minimum activation flow rate: 0.4 GPM (1.51 /min) Maximum flow rate: 9.8 GPM (37.1 I/min) 98° - 120°F (37°- 49°C) (factory default) Maximum temperature is selectable at 1207 (49°C) or at 140°F (60°C) ; 98' - 185'F (37°- 85°C) available with the MCC-91-2 controller for commercial and hydronic applications 120°F (49°C) (factory default) or 140°F (60°C) Indoor only Natural Gas: 0.82 Propane: 0.82 Gas supply: 3/4 inch MNPT Cold water inlet: 3/4 inch MNPT Hot water outlet: 3/4 inch MNPT Isolation Valves are certified to NSF/ANSI 61 for potable water Water Flow Control Water flow sensor, electronic water control device and by-pass Minimum/Maximum Water Supply Pressure 20 - 150 PSI (138-1035 KPa) (recommended 30-80 PSI (209 - 552 KPa) for optimal performance) Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior ,notice. Local, state, provincial and federal codes must be adhered to prior to installation. FLOW TABLE 1 1 MINIMUM © 2015 Rinnai RL94i VC SP(01) 7/2015 � S A'"u Sit Low Lead Content SANITATION NSF/ANSI 372 cex� eo ® c``Rftl External Recirculation Pump Control Water Temperature Control Controller Controller Cable Safety Devices Clearances from Combustibles (suitable for closet, attic, and crawl space installations) Clearances from Non -combustibles Min. / Max. Gas Supply Pressure (sea level) Manifold Gas Pressure (inches W.C.) NOx Rinnai Circ-LogicTM(Included): Recirculation program cycles external pump Simulation feed forward and feedback MC-91-2US (part of the front panel) Deluxe controller: MC-100V-1 US (optional) Bathroom controller: BC-100V-1 US (optional) MCC-91-21JIS (optional; for hydronic and commercial applications) MC-195T-US (optional; for use with Circ-Logic Non -polarized two -core cable, minimum 22 AWG • Flame failure - Flame Rod • Boiling protection • Combustion fan rpm check • Over current - glass fuse • Remaining flame (OHS) • Thermal fuse • Automatic frost protection • Top of heater - 6 inches (152mm) • Back of heater - 0 inches • Front of heater - 6 inches (152mm) • Ground / bottom - 12 inches (305mm) • Sides of heater - 2 inches (51 mm) . From vent pipe - 0 inches • Top of heater - 2 inches (51 mm) • Back of heater - 0 inches • Front of heater - 6 inches (152mm) • Ground / bottom - 12 inches (305mm) • Sides of heater - 1/2 inch (13mm) • From vent pipe - 0 inches Natural Gas: min 4" W.C. (10mbar) max 10.5" W.C. (26.1mbar) Propane Gas: min 8" W.C. (20mbar) max 13.5" W.C. (33.6mbar) Natural Gas: high fire 2.9" W.C. (7.22mbar) low fire 0.61" W.C. (1.52mbar) Propane Gas: high fire 4.7" W.C. (11.71 mbar) low fire 0.87" W.C. (2.17mbar) Complies with South Coast Air Quality Management District 40 ng/J or 55 ppm NOx emission levels Limited Heat exchanger: 12 years* for residential, 10 years for residential and space heating, and 5 years* for Warranty commercial; All other Darts- 5 years*; Labor: 1 year; (* 3 years from date of purchase when used as a recirculating water heater within a hot water recirculation loop, where the water heater is in series with a recirculation system and all recirculating water flows through the water heater, and where an aquastat/thermostat, timer, or an on -demand recirculation system is not incorporated.) Refer to the manual for complete warranty information. 0 (356.6) WEIGHT: 46.3 lb (21.0 9.27 (235.5) kg) n , w�IEF, n1LET 0.4-1.8 10-45 Variable - ( ) UAL C )NGI f ION 714.04 5.05 (128.1) � w o � N B HOT W�4T' "oliT T C E F G -D- CM 00 N °o °o DIMEN- DIMEN- Inches (mm) Rinnai Corporation • 103 International Drive •Peachtree City, GA 30269 •Toll -Free: 1-800-621-9419 •Fax: 678-364-8643 • www.rinnai.us