Loading...
HomeMy WebLinkAboutDrawing Opening �. x F (W x N) 41 1 ;FL13010 4 r 6,35 x 30 (FIXEW/ HAPE) '4 ` 16" I FL15780 8 ; � ti 36 x 61 16 (DOUBLE HUNG) 3. FL15780 8 36 x 61 (DOUBLE HUNG)„ 4 FL15780 8 36 x 61 (DOUBLE HUNG) 5=^F A5786s BED 2 (DOUBLE HUNG), 36 x 61 5 6. FL15780 8 25 06, .4 (DOUBLE HUNG) I <L F.i n 7 FL5823.4 35 x 66 72 r£ (SINGLE HUNG) Co 8 'FL5823 4 35 66 ..a x (SINGLE-HUNG) uy U) KITCHEN ,ciV 3 BATH 1 6 38� .�',o, m s z ENTRY FD z BED 3 w z k J J t Y �" V Lp co 8 7 p LL z BED 1 06 n' cn co a 2 � COPYRI6NT E•TEYPE9T.COY SCALE: DATEOT TO SCALE Nov 15,2019 PAGE DESCRIPTION: Site Plan Al + PAGE: OF 1 IV1RH �:�12'Fj 1 FA b j > — E t "Bui[din Qur ? alt}r: Reputa �cn:. C?n . ust+om' r A, A, rn SCC131150472 Property Information Building Information Owner: WILLIAM&SUZAN ESHLEMAN Wind Zone: 170 MPH. Address: 1736 PONDBERRY LN Exposure Category: C PSL,FL 34952 Minimum Building Dimension: 38 ft. Mean Roof Height: 12 ft. Risk Category: 11 Design Pressure.Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) „„ Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 35 30 7 37.8 -41.0 2 End 36 61 7 36.8 -48.5 3 Int 36 61 7 36.8 -40.0 4 End 36 61 7 36.8 48.5 5 End 36 61 7 36.8 -48.5 _._....................._ _...............- 6 Int 25 36 7 37.8 -41.0 —---- --.-............-— — . _._..._._ .-........_......................— -- -- ......_ _._.-....._.- 7 End 35 66 7 36.6 -48.3 8 Int 35 66 7 36.6 -39.8 Prepared in accordance wills:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 WINDOW& i • • ' • ' • ' • A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A PRODUCT ROUGH ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER + PSF ( ) (-)PSF TESTED DIMENSIONS MULLION REQ Y/N ( ) (-)PSF + PSF SIZE REQ Y/N/NA 1 Int WINDOW 1"LAMIIG FL13010.4 55 55 37.8 -41.0 48 x 72 35x30 No No 2 End Window "Lami'G FL15780.8 55 65 36.8 1 -48.5 54x76.5 3601 No No 3 Int Window "B"'a"'`IG FL15780.8 55 65 36.8 -40.0 54x76.5 36x61 No No 4 End Window 711"LamiIG FL15780.8 55 65 36.8 -48.5 54x76.5 36x61 No No 5 End Window 7/8"Lam1IG FL15780.8 55 65 36.8 -48.5 54x76.5, 36x61 No No 6 Int Window 711S°Lami1G FL15780.8 55 65 37.8 -41.0 54x76.5 25x36 No No 7 End Window pis„Lam' FL5823:4 70 70 36.6 -48.3 1 52 x 96 35x66 YES No 8 Int window 7/8"Lami FL5823.4 70 70 36.6 -39.8 52 x 96 35x66 YES No