Loading...
HomeMy WebLinkAboutProduct Approval J�ndaB,,,fldCode Online r _ }E s n: C � �g� � ��'":2: S �d a�'t � s a'ta ��k� ' ys:k: �•a';_ �"s �t.Akt* _, 44 Y .?°� S ''� w. ..tk, ,��#., w�. tom t �$•i :� 4 1 BCIS Home I Log In [ User Registration Hot Topics Submit Surcharge '� Stats&Facts Publications Contact Us BCIS Site Map Links 1 Search t dbpr a �N'Product Approval :USER:Public User m Product ADoroval Menu>Application Detail FL�k C 010-R8 Application Type ion Code Version Application Status oved pprove y DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived p Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Authorized Signature Jay Lathrop jlathrop@cws.cc Technical Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. �* Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc x Category Windows Subcategory Fixed � Compliance Method Certification Mark or Listing � Certification Agency Keystone Certifications,Inc. Validated By Steven M. Urich, PE El Validation Checklist-Hardcopy Received �4 Referenced Standard and Year(of Standard) Standard 'Year AAMA/WDMA/CSA 101/I.S.2/A440-05 2005 AAMA/WDMA/CSA 101/I.S.2/A440-08 2008 ASTM E1886-05 2005 ASTM E1996-05 2005 PA TAS 201/202/203 1994 Equivalence of Product Standards https://floridabuilding.orgipr/pr_app_dti"aspx?param=wGEVXQwtDgvQEb8FEH60Vrs5wFsWUkbapmdg74baIE3UTeOrPdqGVw%3d%3d[5/2/2019 1:34:51 PM] Florida Building Code Online Certified By Product Approval Method Method 1 Option A Date Submitted 04/08/2019 Date Validated 04/09/2019 Date Pending FBC Approval 04/15/2019 Date Approved 04/19/2019 Summary of ProdU, FL'tlf Model,Number or Name Descrlptton 13010.1 PW-8150 PVC Fixed Window PW-8150 PVC Fig/Fin Fixed Window $ " Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL13010 R8 C CAC CAR 138-1357.pdf Approved for use outside HVHZ:Yes FL13010 R8 C CAC CAR 138-1362. d[dff Impact Resistant:Yes _FL13010 R8 C CAC CAR 138-562. ddff Design Pressure: N/A Quality Assurance Contract Expiration Date * Other: PW-8150, 36"x 72"and 72"x 76"see installation 09/14/2019 r' detail for DPs. Large Missile Impact. In HVHZ may only be used Installation Instructions up to 30ft above grade.Glass complies to ASTM E1300-04. FL13010 R8 II CWS-433D.pdf Verified By: Lucas A.Turner 58201 Created by Independent Third Party: No Evaluation Reports FL13010 R8 AE EvalReport433D.pdf �# Created by Independent Third Party:Yes o . _ 1'3010 2`_ P1N 8150 PVC Fixed Window PW 8150 PVC Flg/Fin Fixed Window,Continuous Head&Sill. Lt^}mlts`of Use Certification Agency CerE�ficate Approved for use,in HVHZ Yes =K< FLt 3010 R8. C CAC,CAR t 38-261 e2 Rdf Approved f"-`use outside HVHZ:;•Yes FL1301tO R8 C'CAC CAR 138-705e2.pdf Impact Resistant Yes..; - FL 13010 R8 .G CAC CAR 138-706e2.pdf_ esign P'ressure''+67.5/-67 5 <. Quality;Assurance.ContractExpiration Date` , 10 er:,Large-Missller Dp= +/ 67p5 psi, Max size"74 1/8 ;x"'r 08/12/2019,, - m 72" Outer-lite mustt6'safety giass'above'30'ft.-In HVHZ:-GlassInstallation Instructions complies'to ASTM E1300 04. FL1"3010 R8 II• VS 510C.Rdf Verifie 'By ,Lucas'kTurrier 58201, .Created by Independent Third Party NoR K - ;y Evaiva'tidn-Reports..., _ FL13010 .R8 AE Evalftport510C odf Created'by,Independent Third Party':"Yes 13010.3 PW-8300 PVC Fixed Window PW-8300 PVC Fig/Fin Fixed Window, 120"x 48" Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL13010 R8 C CAC CAR 138-258.12df Approved for use outside HVHZ:Yes FL13010 R8 C CAC CAR 138-481. ddff Impact Resistant:Yes FL13010 R8 C CAC CAR 138-482.odf Design Pressure: +70/-70 Quality Assurance Contract Expiration Date Other: PW-8300, 120"x 48", DP= +/-70 psf. Large Missile 04/09/2022 Impact.Glass complies to ASTM E1300-04. Installation Instructions FL13010 R8 II CWS-373C Verified By: Lucas A.Turner, P.E. FL PE#58201 Created by Independent Third Party: No Evaluation Reports FL13010 R8 AE EvalRel2ort373C.12df Created by Independent Third Party:Yes 13010 4 PW 8300'PUC Fixed Window Series 83Q0'PVC Fixed`Window, Large MIs'sile Im act,48"x,72" p unit:sjze�:DP55,or 72 x 76"unit size-,DP67_.5,.(DP65 outside q_ .... t. HVHZ) Limits of Use Certification Agency'Certificate Approved for 6se;1fi44VHZ Yes, y , FL13010 R8 G CAC`CAR 138-7093.pdf � Approved for use outside HVHZ:�Yes FL13010�'R8 C=CA6'tAgi138=1320"e2. d�f ,, ,'Impact Resistant:Yes FL13010 R8, C CAG'CAR 138s250.odf ' D'esigwPressure N/A FL13010,R8'C.GAC,:CA11 138=2 74ez.odf ` >- Other .Sizes up to;48;x 72' unitsize at design pressures of FL10�0 R8 C CAC'CAR 1�8-457 pdf . �. https://floridabai[ding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDq%QEb8FEH6OVrs5wFsA•'Ukbapmdg74baIE3UTeOrPdgGVw°/a3d%3d[5/2/2019 1:34:51 PM] Florida Building Code Online, r �. +/, 55 sf or in sizes,Up.to;72 x 76 unit s[ze at designE _; FL13010 R8 C CAC CAR'i38-465 ` pressures of+/ 67.5 psf 16',HVHZ or,-+/ 65,psf outside the FL1300 R8'C CAC CAR 138=534:pdf' HVHZ,with- R8.r�-CAC y AR138- 30clpi Glass complies to ASTM E1300 04 `FLi 010 R8 C CAC'CAR 138-73aeLpdf Quality.Assurance Contract Expiration Date s ? 03/16/2020, !/ Installation Instructions. ., -- Verifletl By:.Lucas A:,Turner,,P E FL_P.E458201 Created byIndependent:Third Party:, o' �. Evaluation Reports..w ?, 7 L 3610"R8 'AE EvalRe" 0 9 pA' h Created by,IndependentThird Party;Y,es t Contact Us::�601 Blair Stone Road.Tallahac_c_ee FL 32344 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Cooyrloht 2007-2013 Stateof Florida.:LPrivacv Statement:;Accessibility Statement:;Refund Statement G= Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with.an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ' v 7 ® eCltacA �M Credit Cal tl -771 �4 x V https://floridabtiilding.orgfpr/pr_app_dti.aspx?param=wGEVXQwtDq%QEb8FEH6OVrsSwFs�%`Jkbapmdg74baIE3UTeOrPdgGVw%3d%3d[5/2/2019 1:34:51 P1i] URNER 1239 Jabara Ave. North Port, FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 159E September 7,2017 Product Description: Series 8300 PVC Fixed Window,Large Missile Impact,48"x 72"unit size DP55 or 72"x 76"unit size DP67.5 (DP65 outside HVHZ) Manufacturer: Custom Window Systems, Inc. 1900 SW 44`11 Ave, Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 61h Edition(2017)Florida Building Code including the HVHZ. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port, FL 2) Approval drawing CWS-159E,signed and sealed by Lucas A.Turner,P.E. 3) Test Reports NCTL-210-3954-01 and-1A, and NCTL-210-3955-01 and-IA, from National Certified Testing Laboratories, Orlando, FL, with Testing Performed: AAMA/WDMA/CSA 101/I.S.2/A440-08,ASTM E1886-05,ASTM E1996-05/09 and TAS 201,202,203 1994(TAS reports 3954-1A and 3955-1A signed and sealed by Gerard J.Ferrara,P.E.) 4) Supplemental Calculations to support CWS-159E,signed and sealed by Lucas A.Turner,P.E. Installation: Units must be installed according to approval document CWS-159E. Limitations of Use: This product: • May be used in O configuration in sizes up to 48"x 72"unit size at design pressures of+/-55 psf, or in sizes up to 72"x 76"unit size at design pressures of+/-67.5 psf in HVHZ or+/-65 psf outside the HVHZ,with max. glass daylight sizes as shown in CWS-159E • Is large missile impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires outer lite in I.G.to be safety glass when used in HVHZ above 30 ft of grade • Requires glazing as shown in CWS-159E, with Kuraray(Dupont)SentryGlas Interlayer per Miami-Dade NOA 14-0916.11 t in DP65 or 67.5 units or Kuraray(Dupont)PVB Interlayer per Miami-Dade NOA 16-1117.02t in DP55 units • Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade NOA 17-0206.10t t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply vvith the requirements of the 6"'Ed. (2017)Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire,nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. ;,�t�b}ltirll�r� = 9/07/2017 y .�a�,fiTt= P :� Lucas A. Turner, P.E. ►Q;•, �,,•_ FL PE #58201 4D ti �t,�tlit h R<a�Rig Document Title: Doc No: FIRM B1-02 Structural Performance Rev No: 7 P-w- .1 Of: 1 "YS?ONIt, Certification Authorization Report Required By: PRO B1-03 CAR & Product ID Number: 138 - 739.0 Issue Date: 10/28/2010- Revision Date: 11/13/2015 Expiration Date: 3/16/2020 Company Code: 138 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified atwww.keystonecerts.com. Licensee Information: Product Information: Custom Window Systems, Inc Model: 8300 Fixed with Fin or Flange 1900 SW 44th Avenue Operator Type: FW Ocala FL 34474 Config: No, GS-5/16"Ann Lami IG Max Width: 48 Max Height: 72 Referenced Standard: Product Rating: PA/TAS 201/202/203 Large Missile, DP +/-55.0, 48x72 O Qualifying Test Information: Test Report No: NCTL-210-3672-1 &-2 Test Report Expiration:13/16/2020 Authorized Signature: Keystone Certifications, Inc. 564 Old York Road, Suite 5 Etters, Pennsylvania 17319 Phone: 717-932-8500 Fax: 717-932-8501 WWW.KEYSTO N EC ERTS.C O M GENERAL NOTES: Q�myia PICTURE WINDOW - LARGE MISSILE IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRINCANE ZONE(HVHZ) 19DO SW 44TH AVE. AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS OCALA,FLORIDA 34474 DEFINED IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 491/4° 73 1/4" 2.GLAZING OPTIONS:(SEE SHEET 3) MAX OVENGE WIDTH 8300 PVC MAX.OVERALL FLANGE WIDTH 48• 72• 3.CONFIGURATIONS:"0".ARCHITECTURAL SHAPES INCLUDE,BUT ARE PICTURE WINDOW MAX UNIT WIDTH MAX UNIT WIDTH NOT LIMITED TO,THOSE SHOWN ON SHEET 2. 451/8" 69 118" 4.DESIGN PRESSURE RATING: IMPACT GLASS DLO GLASS DLO -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND A —————————— ———— GLASS TABLES ASTM E-1300-04e01/09. ¢ Z ¢Z?y -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER < o w O m w Oo 0 I 1 I I I ASTM INFILTRATION T 0-0TEST PRESSURE AND GLASS TABLES w Z O z W F- a Fw�zO�2m -- 77 1/a' I I 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED Z z= ¢ w 0 p MAX I I IN THE DESIGN OF THIS PRODUCT.SEE SHEET 8 FOR ANCHOR O O I-O(;na._F_D_ U L) F OVERALL DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD, p Z—rn Z Z F j U)7MAX.4" B I I B HEIGNH7 I i ANCHOR CALCULATIONS. } 0 3 L)w z=LL UO Z OVERALL HE�IGNHT I I I I I 6.PRODUREQUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT a 21 1,-?�O 72' I I UNIT O I a O=aOw0grn O In w CD w MAX 7.ALL FRAMES ARE FULLY WELDED. R Z N w O-+m t- HEIGHT UNIT O w f-O a �- MAX I I I I 8.SERIES MODEL DESIGNATION PW 8300. a = a w Lu a rn HEIGHT a ~ a a a I 9.THE DESIGNATION X AND O STAND FOR THE FOLLOWING:I 73 t18' I I Aaauurtrrrt 691/8' GLASS O=FIXED SASH. d� ORr=W rrri J P�.......T +. GLASS I I B DLO i i ♦�`5.•'�CEA1 G,fri DLO I 8 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR C I LOCATION. No 56201 '�A I g STATE OF :�14 8 A 9/22/2017 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: TABLE OF CONTENTS GENERAL NOTES AND ELEVATIONS GENERAL NOTES&ELEVATIONS.......1 I RESSURE RATING IMPACT RATING DRAWN BY: DATE: GLAZING DETAILS ARCHITECTURAL .................3 ANY 48"X 72" +/-55 PSF ADE 05/05J07 SECTION VIEWS...................................A _ +- -LARGE MISSILE IMPACT ow # REV.: EXTRUSIONS&B.O.M........................ 72"X 76" CWS-159- E 6-7 ANCHOR SCHEDULE&NO7ES.........6-7 5 PSF SCALE HVHZ 67. : INSTALLATION DETAILS.......................8 SHEET 120 1 OF 8 WINDOW SYSTEM 1900 SW 44TH AVE. - FLORIDA 34474 WWW. W W W.CWS.CC f� PVC PICTUREURE WINDOW IMPACT FULL ELLIPSE("OVAL") Err .._._...._..._......._..--—..._... a z J FULL CIRCLE z w o o a r Z w TOMBSTONE w z O Z G_--t 0 qw�}OMym L- I-w ZI-3:g= Z Zx ¢alw00 O 0a)F-zaFU)a 2 Q 5 -8cn Q z :EZO1U } ¢§pwQ=OZ g9 F-F-Hz it LLNwv}iowmw D. o0rnr o wra W�Ww o' a r- a µllutfliq 112CIRCLE .�, yPLEF!S0- In No 55<01 •LPL OCTAGON TRAPEZOID �30: STATE OF NOTES: y 1.SEE SHEETS 6&7 FOR DETAILED ANCHOR INSTALLATION REQUIREMENTS. 2.THRU FRAME-MASONRY,WOOD OR METAL OPENING. 9/22/2017 THRU FIN-WOOD OPENING. LUCAS A.TURNER,P.E. 01 3.OVERALL SIZE MUST NOT EXCEED THE MAX.WIDTH AND HEIGHT OF FL JA#RA AVE.RECTANGULAR WINDOWS ON SHEET 1. 123H PORT,FL 34 NORTH PORT,FL 34288 4.ANCHOR SPACING FOR ARCHITECTUAL FLANGE AND FIN WINDOWS PH.941-380-1574 MUST FOLLOW THE LAYOUTS SHOWN ON SHEETS 6&7,WITH ANCHOR SHEET DESCRIPTION: SPACING MEASURED ALONG THE LENGTH OF THE PRODUCT. 1/4 CIRCLE TRIANGLE ARCHITECTURAL SHAPES DRAWN BY: DATE: ADE 05/05/07 -- - DWG REV.: CWS-159 E SCALE: SHEET 1:1 20F8 WINDOW SYSTEMS L�-� 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC 8300 PVC PICTURE WINDOW IMPACT a -Z 3: az� 1- ❑WO WWO, W zpz D rzw o I-W�Zo3:gx Z ZS:EQ11�WQQ O OF-O Li,Q=F� 1'OVERALL 1"OVERALL U I--rn U rn 1--Z a l 0- Z zF- 0 O —y 3116'ANNEALED or TEMPERED 3116"HEAT STRENGTH or TEMPERED Z O U U ujzc U— 1/2"AIRSPACE 318"AIRSPACE �, p OF W Z r F- W—=O_ 5/16'LAMINATED 7/16"LAMI GLASS H of oclF}-}N U W LL Q�(pF- 1/8"ANNEALED 3/16'HEAT STRENGTH a Z=d c�O rq O WI-O O.= Y .090 DUPONT PVB INTERLAYER .090 SENTRY GLASS IONOPLAST INTERLAYER x W W w U o r a W IL 1/8"ANNEALED 3116'HEAT STRENGTH QUANEX DURASEAL 6 PURFECT GLAZE".H' gUANEX DURASEAL g PURFECT GLAZE"H' ���``Vy_• C E$^.TG,Q"t IG SPACER SIKAFLEX 552 IG SPACER SIKAFLEX 552 �c;`" No 55e01El y�1r 10 1!2'GLASS BITE 10 1/2°GLASS BITE 7 7 �O: STATE OF .40 L O R 1 z� GLASS TYPE A GLASS TYPE B 9/22/2017 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS GLASS MAXSIZE ORAWNBY: DATE: SETTING BLOCKS PER FBC 2411.3.3.1 W X H ADE 05/06/07 DP+/-55 A 48 X 72 REV.: ` CWS-159 E DP+/-67.5 B 72 X 76 SCALE: SHEET 1:1 3 OF 8 T 4 avEm 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CW S.CC INTERIOR 7 6 8300 PVC B 9 9 s PICTURE WINDOW o a e IMPACT 7 7 1 a z Z-D: a O Z owo Qwoo 1D � w zOz ��_Z_r o �w�zF-�gx Z Z=MaWwoo O OF-OVa=rW 11 U Utn F-ZD.F-tnO- 8 9 O Z�� Z -n m SECTION VIEW B-B a �ZLLm00oLLZ 10 tt tt to < <�OFhtZ— w o5 U)iowvlW LL U)w o�cnF- a =~a w wv' a F- a INTERIOR „>019"1"19vT . ce.isEG'�y'% '�C«' No 55281 "• of STATE OF i�� 11 8 9 #(Oki%*VA 10 ❑ z�. O Q LUC FL PE#58201 P.E. 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 7 B SHEET DESCRIPTION: SECTION VIEW A-A SECTION VIEWS DRAWN BY: DATE: ALTERNATE FIN FRAME ADE 05/05/07 DWG REV.: - CWS-159 E SCALE: SHEET 1:1.33 4 OF 8 PARTS LIST FRAME CORNER CONSTRUCTION COMO ITEM PART# DESCRIPTION VENDOR MATERIAL 1 H-6006B FRAME, PW, MAIN, HEAD MIKRON PVC 1900 SW 44TH AVE. OCALA,FLORIDA 34474 2 H-6006B FRAME, PW, MAIN, SILL MIKRON PVC WWW.CWS.Cc 3 H-6006B FRAME, PW, MAIN, L. JAMB MIKRON PVC ` 4 H-6006B FRAME, PW, MAIN, R. JAMB MIKRON PVC CORNER WELD(ALL SIDES) 8300 PVC 5 H-6006A FRAME, PW, MAIN, FIN MIKRON PVC SCALE 1:8 PICTURE WINDOW 6 P-3113 SCREW SUPPORT FOR PVC TEAM PLASTIC RUBBER IMPACT 7 P-3352 SET. BLK., 85 DUR., 1/8"x 5/8"x 2" LG. FRANK LOWE RUBBER 8 PURFECT GLAZE"H", SIKAFLEX 552 HENKEL/SIKA SILICONE a ? <W o a 9 P-3752 CAP PLUG, 1/2" HOLE M&M SILICONE z w 00 w Lazoz a:—?t LL Hw zF-�2x 10 S-6064 GLZ- BE., FXD. (1"O.A. I.G.) MIKRON PVC o a m§>o o m z zx240r 11 GLASS SEE SHEET 0 oI-od4=°w 0 00rza-I--wcL 0 p —Zuj�j�Ucn 3 1/8" 31/8" o w p:m a 1 2 3 4 5 cr _~� w�w� 1I1II^^I�III 11I^^11I�III m r a m a 21/16" �U 1/16" 1/16' 00P11ORE)1.r ' 2 718" S9: STATE OF PVC FRAME FLANGE-H-60066 PVC FRAME FIN-H-6006A X 1/4" 9/22/2017 LUCAS A.TURNER,P.E. 1/16• 1/2' 3" FL PE#58201 7/8" 0 L� 1 1239 JABARA AVE. 3/16" 8 NORTH PORT,FIL 4288 PH.941-380-1-1574 SHEET DESCRIPTION: PVC GLAZEBEAD-S-6064 SCREW SUPPORT-P-3113 EXTRUSIONS&B.O.M. DRAWN BY: DATE: AIDE 05/05/07 DWG#-. REV.: - CW S-159 -E SCALE: SHEET 1:1 5 OF 8 14'MAX.O.C.(TYP.) "6'MAX(TYP.) IIIIIIIII ' SIIIIE E NOTE 2 4 MAX.(TYP.) IIII1IIII 8"MAX.O.C.(TYP.) SIIIIIIIIII E E NOTE 2 AX(TYP.) 1900rw SW0 44TFDH=}A VE. 6'MAX.(TYP.) OCALA,FLORIDA 34 kI4'7 4 ---------- ————————— WWW.CWS.CC 8300 PVC e PICTURE WINDOWAxOC INSTALLATION (TYP-) INSTALLATION IMPACT 1 ANCHOR(TYP.) ANCHOR(TYP.) MAX O.C. < po(TYP_) owo w W ?zoz r I o i °I_wz �2x Z Zx2a�=�0 ol-O6aw O UyI-Z D• aoo n ozoz w°° zav000 W U- n 0 w nwZ 0- Cn - 0 to I o w1=0 0. —————————— —————————— = = a 3W"' a a ''S�ipuuibpi�/ ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) pt.0 (4 7G�, DP+/-55PSF DP+/-55PSF �`�GG'"..�GEtJ$'�, .` No 56281 %-A ?11Q, STATE OF -*&J ........... ��� NOTES: "llrOi IilifVAulk,��`, 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.ANCHOR SPACING APPLIES TO ALL SHAPES(SEE SHEET 2)ALONG ALL FRAME EDGES.SILL ANCHOR SPACING SAME AS HEAD. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1116"IS PRESENT. LOAD BEARING SHIMS SHALL BE XZ CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 8. 9/22/2017 LUCAS A.TURNER,P.E. 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST FL PE#58201 BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 8. PH.941-380-1574 SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. ANCHOR SCHEDULE& INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. DRAWN BY:. DATE: 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. ADE 05/05/07 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DING 0. REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 8. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-159 - E 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING.THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS),FMA/AAMA/WDMA 300(EXTERIOR DOORS) 1:20 6 OF 8 wlwoovv srsTgns Ll� 4'MAX(TYP.) FT IIIIII 0 IIIIII AN TALLAT P) IIIIII 8'MAX O.C.( tOP.) (TP.) 7 5/6'MAX O.C.(TP.) IjIIIIII 1900Q SW?44 TH A V E. SEE NOTE 2 4MAX(TYP,) SEENOTE2 OCALA.FLORIDA 34 47 4 8"MAX WWW.CWS.CC 8300 PVC PICTURE WND O W 756 MAX O.C. IMPACT MAXOC �P) <zo woo Zz arw OQwZO__ INSTALLATION } 0:3:0 ANCHOR(TYP.) L- F-w ZF-Sg=I Z Z=mawWpO0 OF 06<=F ff0UHF ZnPcoa O Z— Z~00 Z O(9. Vj 7U— I II II III aaa �xU�}�OF-?w2OUo-ZQ�Ow—=O— w o" tL w(n0w nw aIx0U�)Y Y I I I I a ~ a — -------------- 's`�µ,uui,pp�� ———————————————— ,,�% glpREW `':.cEfJs•GP y ANCHORLAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) J •No SS211 •' DP+1-65 PSF DP+/-65 PSF ; 0: STATE OF '(0 '���c(`•'r1 OR1�r'2`C NOTES: 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.ANCHOR SPACING APPLIES TO ALL SHAPES(SEE SHEET 2)ALONG ALL FRAME EDGES. SILL ANCHOR SPACING SAME AS HEAD. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 114". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE y CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. `. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 8. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. FL #58201 RAA BE PROTECTED TO PREVENT REACTION. 1239 JA JABARAAVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 8. PH.941-380-1574 SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. ANCHOR SCHEDULE& INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: ADE 05/05/07 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DING . SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 8.CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-159 E - 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMAIAAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMANVDMA 250(BOX WINDOWS),FMA/AAMAIWDMA 300(EXTERIOR DOORS) 1:20 7 OF 8 MIN.EMBEDMENT SEE TABLE I SUBSTRATE TYPICAL HEAD ANCHORAGE BY OTHERS Comm 1/4"MAX.SHIM SEE TABLE 1 MIN.EDGE DIST. SUBSTRATE 1900 SW 44TH AVE. MIN.EDGE DIST. SEE TABLE 1 BY OTHERS OCALA,FLORIDA 34474 SEETABLEI WWW.CWS.CC SEE TABLE 1 � 1/4"MAX.SHIM . SUBSTRATE BY OTHERS MIN EDGE DIST.SEE TABLE 1 SEE TABLE 1 MIN.EMBEDMENT 8300 PVC PERIMETER SEALANT SEE TABLE I INSTALLATION ANCHOR PICTURE WINDOW BYINSTALLER SEE TABLE 1 INSIDEAND OUT MIN.EMBEDMENT SEE TABLE 1 IMPACT SEALANT BEHIND n FLANGE BY INSTALLER 1/4'MAX,SHIM �� fJ Q Z Q Z 0i 0 o LJ PERIMETER SEALANT Z w w p ¢W a w PERIMETER SEALANT BYINSTALLER W Z O Z W_ I= BYINSTALLER INSIDE AND OUT O Q U)3}O W 3'm u H W Z h O2 INSIDE AND OUT INSTALLATION ANCHOR Z Z=�¢0_WOO SEALANT BEHIND SEE TABLE 1 O O F-O Lj¢d lz-F-W FLANGE BY INSTALLER SEALANT BEHIND p Z-N Z Z F.O cn \ FIN BY INSTALLER Z O(9 U vj S U- INSTALLATION ANCHOR / et I HORIZONTAL SECTION �C ` HORIZONTAL SECTION } Q-O W o=O Z SEE TABLE 1 8 TYPICAL JAMB ANCHORAGE 8 TYPICAL FIN ANCHORAGE F.F I- HEAD AND SILL SIMILAR FOR FIN INSTALLATION FQ- tr F}-}2 O W �ri)w �W p wl=-0 d2 } = d [r3:Wul a (� 114"MAX.SHIM a40 gOREW,f'0'0 SEALANT BEHIND �J G FLANGE BY INSTALLER PERIMETER SEALANT BYINSTALLER MIN.EMBEDMENT -• INSIDE AND OUT SEE TABLE I ' =¢� 4r1� SEE SUBSTRATE BY OTHERS MIN.EDGE DIST. SEE TABLE I SEALANT UNDER SCREW /A'\ VERTICAL SECTION HEAD BY INSTALLER 8 TYPICAL SILL ANCHORAGE JJ�� 2r0�17 TABLE 1:APPROVED INSTALLATION FASTENERS 9/27J LUCAS A.TURNER,P.E. FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIYAMBLEDM MIN.EDGE DIST. J FL PE#58201 FLANGE CONCRETE(2.0 KSI MIN.) 3116"ITW TAPCON 1-1/" 1-1/8" 1239 JABARA AVE. PERIMETER SEALANT NORTH PORT,FL 34288 FLANGE HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3116'ITW TAPCON " 2" BYINSTALLER FLANGE CONCRETE(2.85 KSI MIN.) 3116"ELCO ULTRACON 1" 1• INSIDE AND OUT PH.941-380-1574 D HORIZONTAL SECTION SHEET DESCRIPTION: - FLANGE GROUT-FILLED CMU(ASTM C-90) 3116"ELCO ULTRACON 1-1/4" 2-1/2" 8 BOX FRAME INSTALLATION FLANGE 2X MIN.SOUTHERN PINE(G=0.55) 3/16"ITW TAPCON 1 3/8" 7/8" HEAD AND SILL SIMILAR FOR BOX INSTALLATION INSTALLATION DETAILS OR ELCO ULTRACON FLANGE 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN By: DATE: FLANGE 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD 7/16' UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: ADE 05/05/07 (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" MIN.1/4"FILLET OF CONSTRUCTION_ WS-159 - E. -GRADE ADHESIVE CAULK IS APPLIED DWG REV.: FLANGE 1/8"ALUM.(6063-T5 MIN.)OR - #10 GRADE 5 SELF-TAPPING/- FULL THREAD INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. '- - C 1/8•STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16" PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SCALE: SHEET FIN 2XMIN.SOUTHERN PINE(G=0.55) #8 WOOD SCREW 1-1/2" 7/16" SHOWN FOR FLANGE WINDOWS. 1:2 8 OF 8