HomeMy WebLinkAboutProduct Approval o ;
SCIS Home ( Log In 3:User Registration f. Hot Topics i Submit Surcharge ? Stats&'Facts Publications.�, FBC Staff BCIS Site Map E Links . Search i.
rtld •
Product Approval
i 9 USER:Public User .
Pmduct Aoomval Menu>Product or Anoliration Search>Application List.>Application Detail
mUm. A FL# FL9777-R1 l
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owentcoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscoming.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Undedayments
Compliance Method Evaluation Report from a Florida Registered Architect or a.Licensed Florida
Professional Engineer
rj Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R.Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
Validation Checklist Hardcopy Received
Certificate of Independence FL9777 R11 CO.I OCR14002.8a 2017 FBC Evaluation Report Weathercock
Non-HVHZpdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970. '2015
ASTM D 226 2009
ASTM G 155 2005,
TAS 103 1995
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/11/2017
Date Validated 10/11/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summary of Products
FL# Model,Number or Name Description W
9777.1 Weatherlock G Weatherproofing Underlayment
Limits of Use Installation InstructionsApproved for,for,use in HVHZ: No FL9717 RIJ II OCR14002.8a 2017 FBC Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock N20-HVHZ.pdf
Impact Resistant:N/A Verified By:Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCRi4002 8a 2017 FBC Evaluation Reoart
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party:Yes
9777.2 WeatherLock G(High Tear) Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9777 R11 11 OCR14002 8a 2017 FBC Evaluation Repgft
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ odf
Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 1111 AE OCR14002 8a 2017 FBC Evaluation Retort
Weatherlock Non-ndependentT
_ Created by Independent Third Party.:Yes
9777.3 Weatherlock MAT Waterproofing Underlayment
Limits of Use Installation Instructions
Approved for use In HVHZ:Yes FL9777 Rif II OCR14002 8b 2017 FBC Evaluation Report
Approved for use outside HVHZ:No -Weatherlock HVHZ.pjg
Impact Resistaint:N/A Verified By: Zachary R.Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9717 R11 AE OCR14002 8b 2017-FBC Evaluation Report
i _Weatherlock HVHZ.pdf
Created by Independent Third Party:Yes
9777.4 Weatherlock MAT M Waterproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9777 R11 II OCR14002 8a 201`7 FBC Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.odf
Impact Resistant:N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
EL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ,pdf
Created by Independent Third Party:Yes
9777:5 WeatherLock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9777 R11 11 OCR14002.8a 2Ot7 FBC Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.odf
Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 1111 AE OCR14002 8a 2017 FBG Evaluation Report
Weatherlock Non-HVHZ.pdf
Created by Independent Third Party:Yes
19777.61 WeatherLock Metal Weatherproofing Underlayment _
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL9777 R11 II OCR14002 8b 2017 FB Evaluation Rp ort
Approved for use outside HVHZ:No WeatherLock HVHZ.odf
Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OCRI4002.8b 2017 FBC Evaluation Report
Weatherlock HVHZ.pdf
Created by Independent Third Party: Yes
9777.7 Weatherlock Specialty Tile&Metal Weatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9777 R11 II OCR14002.8a 2017 FBC Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ.vcl
Impact Resistant. N/A Verified By: Zachary R. Priest 74021
Design Pressure: +0/-142.5 Created by Independent Third PartyYes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R11 AE OC1114002.8a 2017 FBC Evaluation Report
Weatherlock Non-HVHZ.Ddf
Created by Independent Third Party: Yes
back ,i�xti
Contact Us::2601 Blair Stone Road.Tallahassee Fl,32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement:'.Accessibility statement::Refund Statemen
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do.not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(S),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if.they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply apersonal
address,please provide the Department with an email address which can be made available to the public.To determine If you area licensee under Chapter.455, F.S.,
please dick here.
Product Approvai.Acceptst
W
C�'eciit Card
5 I
Certificate of Authorization No: 29824
CREEK
17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6'EDITION(2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017
1 Owens Corning Parkway
Toledo,OH 43657_
(800)438-7465
www.owenscorning.com
Manufacturing Location: Brentwood,NH
Houston,TX
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1,1507.1.1
Properties: Physical properties
REFERENCES
Euih Report No. Standard Year
PRI Construction Materials Technologies(TST5878) NEI-039-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) NEI-042-02-01 REV2 ASTM D 1970 2015
PRI Construction_Materials Technologies(TST5878) NEI-045-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) NEI-045-02-01 ASTM G 155 2005a
PRI ConstructionMaterials Technologies(TST5878) NEI-053-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) NEI-053-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) NEI-093-02-02 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-213-02-01 ASTM D 1623 2009
PRI Construction Materials Technologies(TST5878) OCF-237-02-01 UL 1897 2012
PRI Construction Materials Technologies(TST5878) OCF-252-02-01 ASTM D 4798 2001
PRI Construction Materials Technologies(TST5878) 0CF-252-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-253-02 02 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-272-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) OCF-296-02-02 ICC-ES AC 188' 2012
ICC-ES AC 48 2012
PRI Construction Materials Technologies(TST5878) OCF-297-02-01.1 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) 0CF-318-02-01 ASTM D 1970 2015
PRI Construction Materials Technologies(TST5878) OCF-320-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST5878) OCF-320-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST5878) OCF-321-02-01 ASTM D 1623 2009
PRI Construction Materials Technologies(TST5878) OCF-322-02-01 UL 1897 2012
PRI Construction Materials Technologies(TST5878) OCF-355-02-01 UL 1897 2012
'Determined to be equivalent to ASTM D 226-09,Type I and 11
OCR14002.8a FL9777-R11 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule-6.1,G20-3. The manufacturer shall notify CREEK
Technical Services;LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warrant
specifically addressed herein. y,installation,recommended use,or other product attributes that are not
f�`' r"u OWENS.CORNING ROOFING AND ASPHALT LLC
E E i l WeatherLock®Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock@ G" WeatherLock@ G is an ASTM D 1970 self-adhesive undedayment constructed from SBS
(Brentwood,NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq:rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ G is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings. Exposure on the roof deck.shall be limited to a
maximum 30 days.
WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood,NH or SBS modified asphalt,with a fiberglass mat reinforcement. The product is supplied in 1-
Houston, TX) sq.rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq.rollswithnominal dimensions
of 3-ft x 66.7-ft.
WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507,1.1 for
mechanically attached roof coverings. Exposure on the roof deck shall be limited to a
maximum.30 days.
WeatherLock@ Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood,NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq.rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roof coverings, Exposure on the roof deck shall be limited to a
maximum 90 days.
WeatherLock@ WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile&Metal constructed from SBS modified asphalt and surfaced with a non-woven polyester fabric.
(Brentwood,NH or The product is supplied in 2.14 sq.rolls.with nominal dimensions of 3-ft x 71.3-ft.
Houston, 7X)
WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with
adhered clay or concrete file roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.)or TILE BONDT"d Roof Tile Adhesive(The Dow Chemical
Company). Exposure on the roof deck shall be limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete the installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
WeatherLock@ G(High WeatherLock@ G(High Tear)is a self-adhered underlayment used as an alternative to
Tear) ASTM D 226,Type I or Type.II roofing felt and ASTM D 1970 self-adhering polymer
(Houston, 7X) modified bitumen underlayment. The underlayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The
product is supplied with a nominal thickness of 50 mils:in 1:95-Sq rolls with nominal
dimensions of 3-ft x 65-ft.
Weatherl-ock® G (High Tear) is permitted to be used as prescribed in FBC Section
1507.1.1 for mechanically attached roof'coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
OCR14002.8a FL9777-R11 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty;installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK OWENS-CORNING ROOFING AND ASPHALT LLC
WeatherLock@ Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES,LLC
PRODUCT APPLICATION
Min.Roof Slope: 2:12 in accordance with the FBC
Application: All undertayments shall be installed in accordance with the FBC.
Deck substrates shall be clean; dry, and free from any irregularities and debris. Alt
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlaymeht shall be installed with the,release backer removed and pressed firmly
into place to ensure complete contact with the deck. The undedayment shall be installed
with the roll length parallel to the eave, starting:at the.eave, and with minimum.W side
laps and minimum 6"end laps staggered min.6-ft.from preceding course. Additionally,if
applying Weatherl-ockS Specialty Tile & Metal, end laps shall be primed with ASTM D
41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width
of the lap.
It is permissible to back nail the underlayment 12-inches on-center as needed(nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally,WeatherLock®Specialty Tile& Metal shall be back nailed
when installed on roof slopes greater than 3:12.
Min.Application 40°F;Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Undedayment System No.1 WeatherLock Specialty Tile&Metal Only
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c.
Undedayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
underlayment shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -142.5 psf
Pressure:
OCR14002.8a FL9777-Rl l Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes orquality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommendeduse,or other product attributes that are not
specifically addressed herein.
" (j OWENS CORNING ROOFING AND ASPHALT LLC
Li ii�� Weathercock®Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES, LLC
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where'discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck;area shalt be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC:product approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others;in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly,
11') All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6h Edition(2017)as evidenced in the referenced documents submitted by the named,manufacturer.
1����►t�ti r�r iiir�ri
PR PR
,%�'�;ma c. N's 's;'�•, 2017.10.11
No 74021 09:06:29
04'00'
STATE OF :%U
0,�•.,;c Zachary R.Priest,P.E.
R 1�.•'����` Florida Registration No.74021
Q A � �A% Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services;LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest,P.E. does not have,nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002.8a FL9777-Rl l Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended rise,or other product attributes that are not
specifically addressed herein.