Loading...
HomeMy WebLinkAboutEngineering Architectonic Inc November 26, 2019 Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the residence located at 10707 Okeechobee Rd.,St. Lucie County. Manufacturer: Union Corrugating Company Profiles: Advantage-Lok II Panel, FL#25960.1 Code: FBC 2017;Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 30' Maximum Pitch: 2/12 & .05/12 Required Design Pressure: Zone1: -31.46 Zone 2:-48.4 Zone3:-72.6 Design Uplift Pressure: -78.5 psf @ panel fastner spacing of 4-5/8" o.c.along seam Panel Attachment: #10-12 pancake head wood screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8„ Roof Decking: Min. 7/16"thick OSB or min. 15/32" plywood w/8 d nails @ 4"o.c. per &4"o.c.field Zone 1,4"o.c. per&6"o.c.field Zone 2, and 6" o.c.throughout Zone 3 The above approved,as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. OF F`o R pedfully Submit e AR96898 a IVlkhae Seal Architectonic Inc:® i "Y-D A 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1