Loading...
HomeMy WebLinkAboutProduct Approval , metal roof, underlayment Florida Building Code Online Page 3 of 3 S 17022.6 6-"1 in. Nail Strip"(115) 1"rib height, 16"wide,0.032"aluminum,standing seam roof panel mechanically attached to attached to 15/32"plywood or Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 Approved for use outside HVHZ:Yes ALUM ssr.odf Impact Resistant:No Verified By: Locke Bowden,P.E.49704 Design Pressure:+N/A/-Table A Created by Independent Third Party: Yes Other:Refer to evaluation report for conditions and Evaluation Reports limitations of use.Install the assembly in compliance with the FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 installation method listed in this report and applicable code ALUM ssr.odf sections of FBC.Refer to manufacturer's installation Created by Independent Third Party:Yes instructions. 17022.7 7-"1.5 in. Nail Strip"(R5) 1.5"rib height, 19"wide,26 gauge steel,standing seam roof panel mechanically attached to 15/32"plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.7 1.5 Nail Strio 26GA ssr.odf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 127 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes installation method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. 17022.8 8 'EMAX Rib"(RS) 29 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 177022.8 EMAX Rib ssr.odf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 177022.8 EMAX Rib ssr.odf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes installation method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. 17022.9 9-"PBR MAX"(RS) 26 gauge steel,lapped roof panel mechanically attached to 15/32"plywood or wood deck with exposed fasteners. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R7 II FL 17022.9 PER RIB ssr.pdf Approved for use outside HVHZ:Yes Verified By: Locke Bowden,P.E.49704 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: +N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.9 PBR RIB ssr.Ddf limitations of use.Install the assembly in compliance with the Created by Independent Third Party:Yes installation method listed in this report and applicable code sections of FBC.Refer to manufacturer's installation instructions. Back Next Contact Us::2601 Blair Stone Road.Tallahassee Fl.32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: = = MOE Credit Gard--� https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQ... 11/26/2019 ., m2. , q 7160 SSW ,DrN,,e Palm �'It , F-f_ 34590 V7 V 07,L810 4 MM Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 91571" Chem-Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* -86 PSF Mainfield 97.25 PSF Perimeter FASTENER SPACING 6" O.C. 6" O.C. SEAM ADHESIVE Not required 3/16"tco t ntls�uaus Dead Reference Data: ARCHITECTURAL TESTING, INC.TST ID#: 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 X32 i !EQUIVALENCY:UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure mar in of safe 2;1.,- Certificate of Independence: Locke Bowden,P.E.does not have,not will acquire a financial iVVM§t6rtg9ypcompany manufacturing or distributing products under this evaluation. Locke Bowden, P.E.is not owned,operated,or control)e mpj ft� n.jfodurer,or distributing products under this report, a seal STATE OF i 4 "'ONAL ` Limitations: 1.Underlayment to be compliance with current Florida Building Code(FBC)2017 61r'ed.. 2.Minimum slope to be compliant with Florida Building Code 2017 61h ed.,and per with Manufacturer's installation reference. 3.Products are compliant for State of Florida product approval per Rule 61 G20-3.Compliance Method: 1-D 4.Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5.Fire classification is not part of this acceptance.Shear diaphragm values are outside this report. 6.Support framing in compliance w/FBC 2017 6t'ed.,Chapter 22 for Steel,Chapter 23 for Wood and Chapter 16 for Structural Loading. 7.This report does not imply warranty, installation,recommended product use outside of this report. FL 17022.5 1.0 Nail Strip (26GA Steel), 16"Wide Roof Panel -Details 16" 3/4+ „ Panel Profile 16" o.c. Deck: -15/32"or greater Plywood,or -Wood plank Integral Snap Lock For METHOD 2: Apply 3/16"Bead Bostik 915T""Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1"Min. per Table"A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) FL 17022.5 1.0 Nail Strip (26GA Steel), 16"Wide Roof Panel -Details Fastener #10 X 1" Min. per Table"A" Pancake Head Wood Screw 1"Nail Strip Roof Panel --- — //,/_•.'•.. �� JAY r Seam Adhesive Application: Deck: � i For Method 2 -15/32"or greater Plywood, or Apply 3/16"Bead Bostik 915TM Sealant -Wood plank Continuous Along Male Rib Vertical Flange (Refer to Table"A") Isometric View RECENED N I—', - porvwmwinc3 eP��ment Pe S Spectalty Structural Engtnpertnq 1,U,"—N CK,YInc.Certificate of Authorization#8064 Evaluation Report "Ultra HT Wind & Water SeaITIVI•I Roof Underlayment Manufacturer: MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 (740) 622-2645 for Florida Product Approval # FL 11842.3 R4 Florida Building Code 6th Edition (2017) Method: 1 - D Category: Roofing Sub - Category: Underlayment Product: "Ultra HT Wind &Water SealT""' Description: Self-Adhered Underlayment Facsimile of digital copy signed by Prepared b James L.Buckner,P.E. p y• Electronically signed and sealed documents shall James L. Buckner, P.E.,SECB File Copy comply with the provisions of FAC Rule 61G15-23. Florida Professional Engineer#31242 !r _ \\ 00.%J11 0. J11 J�`�,���� Florida Evaluation ANE ID: 1916 REVIEWED ®�,,�®Eg� � � �9�l/��C/@7f�® � `�Q�.•''OGENSLc•••.�,Q Project Manager: Diana Galloway i , Report No. 17-131-UHT-ER ®®� ��a® ���� _ * No 31242 * _ (Revises 15-115-UHT-ER,FL11842.5 R3) ST. L LQ C I E C O U NI le Date: 07/09/17 ;0�=.• '� STATE OF Contents: I '/S70NA01_ Evaluation Report Pages 1-5 ���`""`IIIA 2017.08.28 14:49:18-04'00' CBUCK,Inc.dba CBUCK Engineering Phone:(561)491-9927•Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net Business:1374 Community Dr.,Jupiter,FL 33458•Corp/Mailing:2637 E.Atlantic Blvd,#34069,Pompano Beach,FL 33062 s FL#: FL 11842.3 R4 Date: 07/09/17 N . - -I a Report No.: 17-131-UHT-ER Page 2 of 5 Speclalty Structural Engineering CBUCK,Inc.Certificate of Authorization 118064 Manufacturer: MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 (740) 622-2645 www.mfmbp.com Product Name: "Ultra HT Wind &Water Seal""' Product Category: Roofing Product Sub-Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product Description: "Ultra HT Wind &Water SealTM" is self-adhering membrane composed of a white, non-slip cross-laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner designed for use as a roof underlayment in high temperature conditions. Product Material/ Material Type: Styrene Butadiene Styrene (SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 6th Edition (2017),Chapter 15. Product Dimension(s) Roll Size:36 in.x 67 ft. rolls Thickness:45 mils (nominal) Substrate(s): "Ultra HT Wind & Water SealTM" has been evaluated for application to the following substrates (Design of support is outside the scope of this evaluation): • Plywood • Dens Deck Installation: General Installation Instructions: "Ultra HT Wind &Water SealTM" shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 6th Edition (2017), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. i FL#: FL 11842.3 R4 Date: 07/09/17 Report No.: 17-131-UHT-ER Page 3 of 5 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: ASTM D 1970-15a — Specification Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-15a standard version adopted by the Florida Building Code 6+th Edition (2017) for use as evaluated in this report. Code Compliance: The product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report Scope: This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Product Limitations and • Deck shall be in compliance with applicable building code. Conditions of Use: • Minimum slope shall be 2:12 or greater. • Installation is limited to use with approved roof coverings that are mechanically fastened through the underlayment and is attached to the sheathing or rafters. • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. General Limitations and • Scope of"Limitations and Conditions of Use'for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. • Option for application outside"Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. e This report is a building code product evaluation per FLPE rule (FAC) 611315-36 to comply with Florida product approval rule (FAC) 611320-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is r FL#: FL 11842.3 R4 Date: 07/09/17 Report No.: 17-131-UHT-ER Page 4 of 5 Speclaltll Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). Referenced Data: 1. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID#TST 1556) Report No. MFM-039-02-01, Date: 8/15/13 2. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) MFM Building Products Corp. Licensee#335 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) i FL M FL 11842.3 R4 Date: 07/09/17 --.j Page rt No.: 5 of 51-UHT-ER SpPCldlf'La StrUCtUrc5l Erl9InLPPrIr i(;) CBUCK,Inc.Certificate of Authorization#8064 MFM Building Products Corp. Ultra HT Wind & Water Seal Self-Adhered Roofing Underlayment General Installation Instructions: • Product to be applied directly to a clean dry surface. • Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer. • Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into place onto roof deck. • Adhesive is pressure-activated, so press firmly into place using uniform pressure with a 2-3" heavy steel or rubber roller to seams and overlap. • Overlap end laps a minimum of 6". Side laps must be a minimum of 3". • Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight. • Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature of: 50° F • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. "Ultra HT Wind & Water SealTM" shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 6th Edition (2017), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Product Illustrations ®WLTRQ HT WIND&WATER SEAL t �! -- a ryy'L wt g'