Product Approval
RECEIEt
USER:Public User
4T 1
DEC p 3
fimducr a rbv;;1 r•tcini>Pmd:rcc or annfcano++5r. d Y _I Itic+rt >Application Detail 2019
APP J
s'
RII4t-8-.' , FL FL5259-R28 SL Lucie County,p
Application Type Revision ermitting
Code Version 2017 r
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS usA
Address/Phone/Email 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1330 Ext 242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111.W.Newport,Center Drive
D'eerneid Beach,FL33442
(912)429-8610
MAipgrt@polyglass.com
Quality Assurance Representative. Ariel.Lender
Address/Phone/Email 1111 W.Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1230
ALender@polyglass:com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report-from a Florida Registered Architect or a Licensed
.Florida Professional Engineer
ED Evaluation Report-Hardcopy Received
Florida Engineer:or Architect Name who developed Robert Niem_Inen
the Evaluation.Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 09/13/2021
Validated By John W..Knezevich,PE
�l Validation Checklist-Hardcopy Received
Certificateof Independence FS 25 R28'C01:ZIf3 O1_C(QI R'IFNtIREN.odf 1
Referenced Standard and Year(of Standard) Standard r� e r
ASTM D1976 \� `�' �!® IN
ASTM D226
ASTM D4798 �������-2011 w�
ASTM D6164 �gY
ASTM D6222 eW - 2011 FM 4474 NTY
FRSA/TRIApril 2012 © a LUCIE
2012
UL 1.897 m®C012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method i Option b
Date Submitted. 01/24/2018,
Date Validated 01/29/2018
Date Pending FBC.Approval 01/3012018
Date Approved 04/10/2018
Sum!narV of Products
FL 4 Model,Number or Name Description.
5259.1 Polyglass-Roof Roofing underlayments
Underlayments'
Limits of Use Installation'Instructions
Approved for use in HVHZ:NoFi_S? o R7S li ?OpS 01 FiiJAL ER FO!:GLASS U,IDERLAYt.1FlN?TS FL-5259-
Approved for use outside HVHZ-Yes R28.odf
Impact Resistant:N/A Verified By:Robert.Nieniinen PE-59166
Design Pressure:+N/A/-622.5 Created by'IndependenbThird Party:Yes.
Other:1.)The design pressure in this Evaluation Reports
application relates to one particular- FL5259 R28 AE 2015' 01 FINAL.FR P6LYQLAS5 UNDERLAYMELaS FL5259-
underlayment system(over concrete deck) R28.adf
for-use under foam-on file systems(where Created by IndependentThird Party:Yes
the underlaymentforms part of the load-
path).Refer to ER Section 5.6.4 for other
systems,other deck types and associated
maximum design pressures..2.)Refer to ER
Section 5 for other limits of use.
Contact Us::2601 Blair stone Road:Tallahassee FL 32399 Phone:650-487-1824
The State of Florida is an.ANEED.employer.Copyright 2007-2013 State of Florida ::privacy Statement::Accessibility statement::Rebind-Statement
Under.Florida law,email addresses are public records.If you do not want your e-mail address.released in response to a,pubiic:records request,do not send electronic.
mail to this:eptity.Instead,.contact the office by phone or by traditional mail.If you have.any questions;pleaseco850.487.1395.*Pursuant to section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under chapter 455,`F.S.must provide the Entad
with an email address if they have
one.The emalis provided may be used for official communication with the licensee.However email addresses are public_record.If you,do not wish to supply a
personal address,please provide the Department with an email address which,can be made availableto the pubric,To'determineif you are a licensee under Chapter
455,F.S.,please ciick.jisre
Product Approval Accepts:
Credit Card
-Safe
c n,gi, � yci�•
U(414EMOjetC.
ROOFING.COMPONENT EVALUATION:
1. SCOPE!
Product Category: Roofing
Sub-Category: U n d erl aym ent
Compliance-Statement: Root'Underlayments, as produced by Polyglass USA, Inc., havedemonstrated compliance With the.
fol{owing sections:of the a Edition(2017)Florida'Building.Code through testing in accorda n ce;with the fol,loWing Standards.
Compliance issubjec:to the.Installation Requirements"and Limitations-/Conditions of Useset forth herein.
2,. STANDARDS:
Section Pro "ert' Standard ,Year
1504.3:1. Wind Uplift FM 4474: 2011
1504:3.1 Wind Uplift UL 1897 2012
1507,2.3/1507.1.1 Physical Properties. ASTM D226 2009
1507.2.4/1507.1-1,1507:2.4.2 Physical Properties: ASTM D1970 2015:
1507:3.3 Physical•Properties FRSA/TRi-April 2012 2012
1507.11.2 Physical Properties ASTM D6164 2011
1507.11.2 Physical Properties ASTM D6222 2011.
TAS 110 Accelerated Weathering. ASTM.D47.98 2.011
3. REFERENCES-
Enti Eibmination Reference. Date
FM Approvals(fST 1867) Wind Uplift '3004091 01/12/2000
PRI(TST 5878) Physical Properties PRI01111 04/08/2002,:
PRI(TST 5818) Physical.Properties PUSA-005 02-01 01/31/2002
PRI(TST 5878) Physical Properties PUSH-013-02-01 12/23/2002
PRI(TSC 5878) Physicai,Properties PUSA-013-02-02 12/23/2002
PRI(TST 5878) PhysicalProperties PUSA7013-02-03 12/23/2002
PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003
PRI(TST5878) Physical.Properties PUSA-028-02-01 07/13/2005
PRI(TST 5878), Physieal`Properties PUSA-033-02-01 01/12/2006
PRI(TSTb878) Physical Properties PUSA -035-02=01 09/29/2006
PRI(TST 5878) Physical Properties: PUSA-055,02-02 12/10/2007
PRI(TST 5878) Physical_Pioperties PUSA=061.02-02 01/28/2008
PRI(TST5878) Physical Properties PUSA-076-02-01 02/22/2008
PRI(TST 5878) Physical Properties PUSA-083=02-01 04/14/2008
PRI•(TST5818) Physical Properties PUSA=088-02-01 07/29/2009
MTi(TST 2508) Physical Properties JX20H7A- "04101/2008
MTI(TST 2508) Physical Properties RX14E8A :01/29%2609
ERD(TST 6049) Physical Properties 11752.09:99-1 02/08/2000
ERI}(TST 6049) Wind Uplift 11757.08.01-5 OS/13J2001
ERD(TST-6049) Wind Uplift: 13.776.06;02' 03/]:5/2003.
ERD(CST 6049) Physical Properties :02200.07:03 07/1412003'
ERD(CST 6049) Wind Uplift P1740.01.07• 01/04/,2007
`ERD(M-6049) Physiical Properties P5110.04.07-1 04/11/2007
ERD'(TST 6049)' Wind Uplift P9260.03:08, 03%21%2008
ERD(TST-6049) Physical Properties P134501.08.09 08/13/2009
ERD(TST-6049) WindUplift P30540:11.09-R1 11/30%2009
ERD(TST 6049) Physical Properties 1311030:15.09-1 11/30/2909
ERD(TST 6049) Wind Uplift P1103011.09-2 1-1/30/-2009
ERD(TST-6049) Physical Properties P11030:11.09-3 11/30/2009
ERD(TST.6049), Physical Properties P33360.06.10 06/25/2010
ERD(TST 6049) Physical Properties P3337003:11 03/02/2011
ERD(TST 6049) Physical;Properties P33370.04.11 04/26/2011
ERD.(TST6049) Physical Properties P37300.10;11 .10/19/2011
NEMO ETC,LLC, Evaluation Report'1)12060.02.09-R24
Cketcate ofAuthori2ati.on#32455 67'EDITION(2017)FBC.NON-HNHZ EVALUATION FL5259=R28
Polygiass Rtiof Underlaymentst(954)2331230 Revision 24:01/24/2018
Page 2 of 14
NEW etc.
Enti Examination Reference Date-
ERD(TST 6049) Physical Properties P40390.08-12-1 08/06/201208/0/2012
ERD(TST 6049) Physical Properties P40390.08-12-:2
ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD(TST.60.499) Wind Uplift P39680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P4S370.04.13 04/26/2013
ERD(TST 6049) Wind,,Uplift P1738.02.07-112 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD(TST 6049) Wind Uplift P41630..08.13 04/06/2013
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/261/2013
ERD(TST 6049) Wind'Uplift P11781.11. 03-R1- ' 11/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020,07.147,1 09108/2014
ERD(TST 6049) Physical Properties 6020.09.14-2 09108/2014
ERD(TST 6049) Physical Properties 6020.09.-14-3 09/0812014
ERD(TST 6049) Physical Properties 6020.09A44 09/08/2014
ERD(TST 6049) Physical,Properties 6020.09.14=5 09/08Y2014
ERD(TSL 6049.) Physical Properties 6020.09.14-6 01/08/1014
ERD(TST 60-49-) Physical Properties 1346526.10.14 10/03/2014
ERD(TST 6049) Physical Properties P43290.10.14 10/17/1014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physi I cal.Properties P4039.0.04AS 04/03j2015
FRO(TST.6049) Physical Properties P44360.10.14-R1 05A8/2015
ERD(TST 6049) Physical Properties PLYG-SC8080.05,15-1 05/26)2015
ERD(TST 6049) Wind Uplift PLYG-SC9905.05.1'6-1 OS/17,/,20'16
ERD(TST 6049) Physical Properties PLYG-568080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10112/2016
ERD�(TST 6049) Physical Properties PLYG-SC13040J2;16 12/27/2016
ERD(TST 6049) Physical Properties PLY.d-SC11900.03.17 021110/2017
ERD(TST 6049) Physical Properties PLYG-5012115.08.17 08/08/2017
[CC-ES(EVL 2396) IBC.Compila,nre ES14-1697 11/01/2014
Miarni7Ciade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/122/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/19/2011
UL,U.C.(QUA9625) Quality Control Service Confirmation Exp.10/05/2018
4. PRODUCT DESCRIPTION:
4. Fastened:Un er avrffe
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester-reinforced',.SBS'modif ied bitumen base sheet.
4.1.3 Polyglass.G2.Base is 6 fiberglass-reinforced,asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet.
42
7
S61
"AdhOei Ond"
nts
_ -f
4.2.1 Polystick MTS or Polystick.MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing'merribrane, glass
fiber reinforced,surfaced with polyolefinic film surface;
meets FRSA/TRI April 2012:
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with an
aggregate surface;meets ASTM D1570.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface;meets ASTM D1970-and'FRSA/TRI April 2012.
NEMO ETC,LLC, Evaluation Report P12060.02.09-R24
certillcote of Authafizati.n#32455 13"EDMON(2017)FBC NON_HVHZ.EVALUATl0W FL5259-R28
P.6lyglass Roof Underlayments;(954)233-1230 Revision 24:01/2412018
Page 3 of 14
�N:NEMO et
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced,with a granular surface;meets FRSA/TRI April 2012.
4.2.5 Polystick TU Max,is a nominal 60-mil thick rubberized.asphalt waterproofing,membrane with a 190 g/m2 polyester
fabric surface;meets ASTM D1970 and FRSA/TRI April 2012.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester
reinforced,APP modified bitumen cap sheets;meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Pro'" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced;with a polyester fabric surface;meets ASTM D1970.
•4.2.8 Polystick Tile Pro'" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and FRSA/TRI April 2012.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polypropylene film surface;meets AC188 and physical requirements of ASTM.D1970 (See Section
5.8).
Mechanically Fastened and/or Bondetl Underlayments
4.3.1 Elastoflex G TU is a polyester reinforced;.modified bitumen tile underlayment composed of a sand-surfaced SBS
modified bitumen back-side and granule-surfaced APP modified.bitumen top-side. Elastoflex G TU is for use as,an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single,Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically:fastened tile roof systems or HotAsphalt applied "Cap Sheet" in the "Two Ply
System"from FRSA/TRI April 2012(04-12)beneath of
fastened or adhered the roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D. 6.164.
Elastoflex 56 G and Elastoflex S6 G FR are for use as an altemateAo "Mineral Surface Roll Roofing (ASTM D6380,
Class M)in the"Single Ply System"from FRSA/TRI April-2012(04-12)beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied"Cap Sheet" in the"TwoPly System".from FRSA/TRI
April.2012 (04-12) beneath mechanically fastened or adhered tile roof,systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "-Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4:3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied`:Cap Sheet" in the"Two Ply System"from FRSA/TRI April 2012.
(0442)beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the "Two Ply System"from FRSA/TRI April 2012 (04-12).beneath mechanically fastened tile
roof systems.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO I eta nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on.which this Evaluation Report, or previous-versions thereof,is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is hot for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire.
ratings of this product..
5.4 Polyglass Roof Uriderlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be:made to the.Authority Having Jurisdiction for
approval based on this evaluationcombined with supporting data for the prepared roof covering_
MEMO ETC,LLC. Evaluation Report P12060.02.09-1124
certificate of Authorization#32455 6TM EDITION(2017)FBc NON-HVHZ EVALUATION: FL5259-1128
'Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018
Page 4 of 14
ON EM0.l etc,
5.5 Allowable Roof Covers:
TABLE 1 ROb COVER;OPTIONS
f . .
Wood Shakes Sate
Underlayment Asphalt Shingles Nail-On Tile Foam-on Tile Metal &Shingles
Elastobase Yes Yes Yes Yes Yes Yes
(Base Sheet In.2•ply system) (Base Sheet in 2-ply system)
Elastobase P Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in 2-ply system)
. No Yes Yes No No No
Polyglass G2 Base
(Base Sheet in 2-ply system) {Base Sheet in 2-ply system)
Yes Yes NaNo N8
Polyglass APP Base No
(Base Sheet in 2-ply system) (Base Sheet i6 2-ply system)
Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes
Polystick.IR-Xe Yes. No No No Yes Yes
Polystick TU P No Yes Yes (See5.5.1) No No No
Polystick TU,Plus Yes Yes Yes (See 5.5.1). Yes Yes Yes
Polystick TU Max No Yes Yes (See 5.5.1) Yes No No
Polystick Dual Pro Yes No No Yes Yes Yes
Polystick Tile Pro Yes Yes Yes (See 5S.1) Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
Elastoflex 56 G Yes Yes Yes(See 5.5.1) No Yes Yes
Elastoflex S6 G FR Yes Yes No No Yes 'Yes
Elastoflex G TU. Yes Yes Yes (See 5;5.1) No Yes, Yes
Polyflex 6 I Yes Yes Yes (See 5.5.1) No. Yes Yes
Polyflex G FR Yes Yes No No Yes -Yes
Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No. Yes Yes
Mule-Hide SA-APP.Cap Sheet Yes Yes Yes (See 5.5.1) No Yes Yes
or 5A-APP Cap Sheet(FR)
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile adhesives/undied pyrnent cmnbinations.
ALEOWABLE.TR.EADHESIVE/UNDERIAYNIENTCLiMBINATIONSx
Adhesive Florida Product Underlayments
Approval
DAP Foam Touch'n Seal StormBond Roof FL14S06 Polystick TU Plus,_Polystick TU.Max
Tile Adhesive.
Dow TileBond' FL22525 Polystick TU P,Polystick TU Plus,-Polyf)exSAP,or Tile Pro
Polystick TU P,PolystickTU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives PolysetI'AH-160 FL6332 Elastoflex GTU,Elastoflex S6 G,P610ex G,Polyflez SAP,;PolYflex SA Cap FR;
Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP CapSheet(FR)
PolystickTU P,Polystick TU Plus,Polystick TU Max,Polystick Tile Pro;
ICP Adhesives Polysete RTA-1 FL6276 Elastoflex G TU,Elastoflex S6 G.Polyflex 6,Polyflex SAP,Polyflex SA Cap FR,
Mule-HideSA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Refer.to Tile Manufacturers or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC: Evaluation Report P12060.02.09-R24
Lertiftate of Authorization#32455 6t"EDITION(2037)FBC NON-H VH2 EVALUATION EL5259-RZB
Polyglass Roof.Underlaymenis;(954)233-2230 Revision 24:0112412018
Page 5 of 14
it
*NEMO-JL:itC.
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations);Dual Pro,Tile:Pro,Polyflex. SAP or SAP FR;Mule-Hide SA-.APP Cap Sheet orSA-APP Cap:Sheet
(FR)self-adhered to
Y New untreated plywood;ASTM.D41 primed new untreated plywood;Existing plywood;ASTM D41,prmed existing,
plywood; New'or,existing; unprimed OSB;ASTM. D.41 primed OSB;:Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete;: Huber Engineered Woods "ZIP System" Panels
(designed,and installed to meet wind loads for project).
Note.Polyglass'does not require priming pf new or existing plywood ord§&sheathing. New or existing plywood or,
OSB sheathing'should be cleaned of 611 dirt and debris prior to application of Polystick membranes.
Elastoflex G TU,Elastofi"ek S6 Gor Elastoflex.S6:13 FR in`hbtasphalt to:,
➢ ASTM D41 primed structural concrete.
Polyflex G or Poiyflex.G FR torch-applied to:
➢ ASTM D41 primed'structural concrete
5.6.2 Bond-to-Insulation:
Polystick-(all variations),,Polyflex SAP or SAP FR;Mule-Hide SA-APA Cap Sheet or SA-APP Cap:Sheet(FR)self.-adhered
to:
ASTM C1289, Type ll, Class 1 polyisocyanurate or Type, V polyisocya.nurate-cphn, osite, insulation; Dens Deck
DuraGuard;Dens Deck Prime;.orSECUROCK Gypsum-Fiber Roof.Board.
Elastoflex G TU,Elastoflex S6 G or ElastoflexS6 G FR in hot asphalt to;
Dem-Deck Prime,.or SECUROGK,Gypsum-Fiber Roof Board.
Polyflex G or Polyflex.G FR torch-applied to:
➢ ASTM D41 primed structural concrete;Dens Deck.Prime or SECUR©CK Gypsum•-Fjber.Roof Board..
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof�covering manufacturer's Product.Approval_, For installations under-foam-on,tile
system's;insulation attachment shall be designed by a.qualified design profeissional:andlnstalled based'on testing of
the' insulation/under!ayment:system.in:accordance:with FBC Section 1504.3.1.
5.6:3 Bond to Mechanically AttachedBase Laver:
Polystick(all variations), Polyflex SAP or,SAP FR, Mule-Hide SA-APP Cap Sheet or SA=APP.Cap Sheet(FR)'Dual Pro or
Tile.Pro self-adhered to:
y ASTM.D226,-Typed or-11-felt;Elastobase;Elastobase:P or Mule-Hide;Nail Base.
Elastoflex G TO,Elastoflex S6.6 or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM 1)226,Type I or 11 felt;Elastobase;Elastobase'P,Mule-Hide.Nail',Base orPolyglass G2,Base..
PolyflexG or Polyflex.G FR'torch-applied to:
Elastobase;Elastobase P,Mule-Hide Nail Base;Polyglass.G2 Base.or,Polyglass.APP Base.
For,installations.under mechanically attached prepared:roof coverings, base layer shall be attached'per minimum
codified requirements. .For installations under foam-on tile systems; base layer shall be attached per minimum
requirements of-FRSA/TRI Apri12012(04-12),Appendix A,.T8ble-.A or as.listed in'Section:,5.6`.4 herein,or as.tested in
accordance with MC Section 1504.1':1;
.NEMO EfC;LLC. Evaluation Report P12060.02:09-R24
'Cnr6ficgtc fAu-h._" d—#32455 61'ED1T10N.(2017)FBC NON-HVHZ EVALUATION .Fr.S259-R2a
Pulyglass Roof Underlayments;1954)2334230 ReiAsion;24:OIP412019
Page 6 of,14
etc.
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSAITRI April 2012 (04-12) does not,
address wind uplift resistance of all undeflayment systems beneath foam-on the systems,where the underlayment
forms part of the,load-path. The following wind uplift* limitations apply to underlayment systems that are not-
addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance' based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2(the 2 to'l margin of safety per FBC'1504.9 has already been applied).Refer to FRSA/TRI April 2012(04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure=-90 ps
Deck- Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU p Sheet,and
I P P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Poiyflex SAP FR,Mule-Hide SA-APP Ca
Mule-Hide SA-APP Cap Sheet(FR),self-adKered.
#2 Maximum Design-Pressure=-97.5 psf-
Deck: Min.15/31-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS 6e Polystick MTS.PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TV Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide-SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
IY4"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#3 Maximum Design.Pressure=-105 13sf:
Deck: Min.15j32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment-Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Pblyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap.Sheet(M),self-adhered.and back-nailed within the selvedge=edge side laps using 12 ga.is
IY."ring shank nails.through 32 ga.,1-5/8"diameter tin-caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-135 ps
Deck: Min.15/32-in-ch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Base Ply: (Optional)Polystick NITS or Polystick MT$�PLUS,self-adhered.
Joints: Min.4-inch wide strips of Elastaflex SA-V over all plywood joints.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR;Mule-Hide SA-APP-Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#5 Maximum Design Pressure=-315
_ps
Deck: Structural concrete to meetproject requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100orASTM D41
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU.
Pius,Polystick TU Max,Tile Pro,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP-Cap,Sheet(FR);self-adhered.
#6 Maximum Design Pressure=-622.513
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment:Elastoflex-G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or.Polyflex,G,torch-applied.
#7 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSS to meet project requirements to satisfaction of Authority Having.Jurisdiction.
Base.Sheei: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x,1.25-inch long x 11-inch head diameter round metal cap hails
Spacing; 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Plus,'Polystick TU Max;Polyflex SAP,P, olyflex SAP FR,Mule-Hide SA-APP.Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered-
NEMAEtc,LLC. Evaluation Report P12060.02.09-R24
CertT,wfe qfA.th.,iwN#3245S 6"EDITION(2019)FBC NON-HVHZ EVALUATION FL5Z59-R28
Polyglass Roof UnderlaVments;(954)2334230 Revision 24-01124/2019
Page 7 of 14
MEMO,etc.
#8 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o:c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:,Polystick TU P,Polystick TU Plus,Polystick TU:Max,Polyflex SAP,Polyflex SAP FR,Mule=Hide.SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#9 Maximum Design Pressure=-37.5 psf*:
Deck: Min,19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 127inch.o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or E(astoflex.S6 G,applied in full mopping of hot asphalt.
#10 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226'Type 11 felt
Fasteners: 11 ga.x1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side.laps and 4-inch.o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment Polystick TU P,Polystick TO Plus,Polystick TU.Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt.
#11 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements to.satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type ll felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlaymentonly)Polystick MTS or Polystick MTS PLUS;'self-adhered.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,PolyflexSAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G-TU or Elastoflex S6 G,applied in full mopping,of hot
asphalt.
#12 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base:Sheet: Elastobase(sanded top surface for hot-asphalt ortorch-applied cap or poly-film.surface for torch-applied cap)
Fasteners: Simplex MARX Cap Fasteners
Spacing: 9-inch o.c.atthe 2-(nch wide side laps and 18-inch o.c.attwo(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#13 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied:cap or poly-film surface'fortorch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12Anch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#14 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Muie-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3 mch wide side.laps and 6-inch o.c.at.four(4)equally spaced staggered center rows.
Base'Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick'TU Max,P61yflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
NEMO ETC,LLC. Evaluation RepogP12060.02.09-R24
Certificate ofAuthorhation H32455 0 EDITICN(2017)FSC NON=HLU
VHZ EVAATION FL5259-R28
Polyglass Roof Underlayments;(954)233-1230, Revision 24:01/24/2b38
Page 8 of 14
ON EMO
I etc.
#15 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction ofAuthority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface fortorch-applied cap)
Fasteners: Simplex:Original Cap Nails
Spacing: 6-inch o.c,at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#16 Maximum Design Pressure=-60psf:
Deck: Min..19 32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphaltor torch-applied cap or poly-film surface for torch-applied cap)
Fasteners, 11 ga.x,1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c,at 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex'G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#17 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top-surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with CMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch c.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G;torch-applied.
#18 Maximum Design Pressure--67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to.satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires:use ofaorch-applied underlayment)
Fasteners: 12 ga.k 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied
#19 Maximum Design Pressure=-75 psf:
.Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of torch=opplied underloyment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with
OMGFiat Bottom Plates, (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c.at the 4-inch wide side laps and 104nch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch-applied or Polyflex G, torch-
applied.
#20 Maximum Design Pressure=-90 psf:
Deck: Min.15%32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at:two(2)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in.full mopping of hot asphalt or Polyflex G,torch-applied.
#21 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners; OMG#12.5tandard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c.at the 44nch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex.G,torch-applied-
#22 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base-Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#f12 DP or Trufast#14 HD with.Trufast 3"Metal.Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c_at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
NEMO ETC,LLC_ Evaluation Report P12060.02.09-R24
Ceiticate o/Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1128
Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018
Page 9 of 14
t
*NE I MO etc..
#23 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base.or.Polyglass APP Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume'Steel Plates,OMG Roofgrip#14 with
CMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast, 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four.(4)equally spaced staggered center rows.
Underlayment;Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or.torch-applied or Polyflex G, torch-
applied.
#24 Maximum Design Pressure=-97.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements:to satisfaction OT Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top:surface)
Fasteners: 11 ga.x"1:25-inch x 3/8-inch head diameter annular ringshank roofing nails at 1-5/8-inch diameter fin caps
Spacing: 4-inch o.c.at the 4-inch wide side-laps and 4-inch o.c.at'four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS or Polystick MTS PLUS,self-adhered.
Underlayment:Polystick TU P,Polystick TU Plus,Polyitick TU Mix,Polyflex SAP,Polyflex-SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap:Sheet(FR),self-adhered.
#25 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AuthorityHaving Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied.cap or poly-film surface for torch-applied cap).
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c::atthe•2=inch wide side laps and 6-inch o.c.at three.(3)equally spaced":staggered centerrows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Poiyflex G,torch-applied.
#26 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-inch plywood,to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x1.25-inch x 3/8-inch head diameter annular ring shank roofing nails ata-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4).equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS or Polystick MTS PLUS,self-adhered
Underlayment:Polystick.TU P,Polystick,TU_Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#27 Maximum Design Pressure=-120 psf:
Deck: Min 15%32-inch plywood to meet project requirements'to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film"surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with'OMG T'Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o:c:at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#28 Maximum Design Pressure=-120 dsf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base:sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP orTrufast#14 HD with Trufast 3"Metal Insulation.Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c,atfive(5).equally spaced staggered center rows.
Underlayment:Elastoflex 1G.TU or Elastoflex 56 G,applied'in full mopping.of hot asphalt.
5.6.4-1 All other direct-deck, adhered Polyglass underlayment systems beneath"foam-on tile system_s carry a Maximum
Design Pressure of-45 psf.
NEMO ETC,LLC. Evaluation Report P12060.02.09-R24
Certd7carc Of Authorization#32455 e'EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018
Page 10 of 14
^
|
*NEMOjetc.
5�.2 For mechanically attached Basesha$the maximum design pressure for the selected assembly shall meet or'exceed
that required under Fns^/rmApril zozz(04-1z),Appendix x^Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone-1 design
pressure determined inaccordance with rBCzGV9. mthis case,Zones Zand sshall.employ anattachment density
designed by a qualified design pmfessinxa| to resist the elevated pressure criteria. Commonly used methods are
ANSySPmVvoI,fKxLoss PmvooiionData Sheet 1,2yand Roofing App|ixadnnStandard RAS 117. Assemblies marked
with
Ion astensk:4� carry the limitations-set forth/n Sect/nn 2.2.10.1 of px4 u,s, Prevention Data Sheet 1-29 (January
ZUl6)for Zone 213enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobas�P, Polyglass G2 Base or Polyglass APP Base.shaii not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shal|not be left exposed for longer thvn 90-days after installation.
Polystick MTS, MTS PLUS,TO P,TO Plus, TO Max,.Dual Pro,Tile Pro or Elastoflex G TO shall not 6eleft exposed for
longer than 1OU'daysafter installation.
Po|vUa/sxp or SAP FR, or xxu|c'xiae sA-xpp Cap She't or SA~App Cap sheet,<�x1 does not have an exposure
limitation, unless the prepared roof covering is to be-adhesive-set tile,.in which case the maximum exposure is �O
days.
Elastoflex SG G or Elastoflex S6 GTR or Polyflex G or Polyflex G FR does not,have an exposure limitation, unless the
prepared roof covering ixto be adh6yive-setti|e (E|*stvf|c* S6 G or pnivf|ex G only), in which case the maximum
exposure iszDVdays�
5.8 Polystick MU-X has been found through comparative:testing to.have a lesser coefficient of friction than ASTM D226
roofing felt in adry condition,tested,t-stanb
dor�|� o*ntorv�cond� ro
ioo�. �nnc� e't between puohvserand s�/e�as
set fo�hinse�mn«.3,Note 1ofASTM Dz�7o'1s'should beestabxshedasmoslip resistance.
5,9 Tile Slippage Limitations(FRSA/TRl AOril 2012(04712));
When loading roof tiles on the unde,ayment in direct-deck tile assemblies, the maximum roof slopeshaU be as
follows. These slope.limitations can only be exceeded by using battens during loading of the.roof tiles.
Underlayment Tile Profile Staging Method Maximum Slope
Flat IG-tile stack 7:12
Elastoflex G TU Lugged 8-tile stack(6 over 2) 6:12
Elastoflex S6 G or 56 G rR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polystick MTS or MTS PLUS Flat 6-tile�stack(4 over 2) 5:12
Lugged 6-tile stack(4 over 2), 4:12
Polystick Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat 6-tile stack(4,oveir 2)or 10-tile.stack 7:12
Polystick TU Max Lugged GAile stack(4 over 2) 7;12
Lugged 10-tile stack 6:12
Polystl�k TU P Flat 6-tile stack(4 over 2) 6:12
Lugged 6-tile stack(4 over 2) 4-12
Flat or Lugged 6-tile stack(4 over 2) 7;12
PolystickTU Plus Fiat or Lugg�d I 10-tile stack 6:12
Polyflex G or 6 FR Flat or Lugged 6,tile stack(4 over 2) 4:12
Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 77777t 4.12
meMnETC,LLC. Evaluation Report P12060.02.09-R24
Certificd*pf^uthorization#32455 15'"EDIT�(����w��amm�mn ���
pvh:ueRoof u"ucnunnents;ps4)zy*12su Revision z*uz/2w2oo
Page z1o*m
ONEIVIO[etc.
6. INSTALLATION;
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.,
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and primethe substrate(if applicable).
Elastobase,"Elastobase Rrbi.Mule Hide Nail Base .
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the codified,requirements for ASTM D226,Type.II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase,Elastobase.P or Mule-Hide Nail Base may covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex G TU, Elastoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR,torch applied. Roof cover limitations are those are
those associated with the top-layer underlayment;as set forth in Table 1.
6.3.2 Tile Applications:
Elastobase,Elastobase P or Mule-Hide Nail Base are imitedto use as a mechanically attached base sheet in the"Two
Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table 1 anis Section 5.6.4 herein,coupled with
FRSA/TRI April 2012(04-12)Installation Manual.
6 4 Polystick MTS,MTS_PLUS;IR Xe,TU P,TU Plus,TU Max,Dual Pro,Tile Pro or~MU X or PolyflexSAP,iaolyflex SAP FR,
.� -
Mule HideSA APP Cap,Sheet or Mule Hide�SA APP Cap Sheet(FR)�.
..__.. .. _ ... _ _..
6.4.1 Shall.be installed in compliance with the codified requirements for ASTM D1970(except Polystick TU P)underlayment
in FBC Table 1507.1.1 for the type of prepared roof covering to be installed.
6.4.2 Direct-to-Deck with Mechanically Fastened Roof Covers:
All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hide SA-APP
Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-
Hide back nailing guidelines. Nails shall be corrosion resistant, 11gaugering-shank type with a minimum 1-inch
diameter metal disk or Simplex-type metal cap nail,at a minimum rate of 12"o.c. Polystick TO Plus should be back-
nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of
membrane. The head lap membrane is to cover the area being back-nailed.
All seal-lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand '�rr
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro,align the edge of
the top sheet to the end of the glue pattern _ w
(the sheet will overlap the fabric).
T.i .. a a,
View of Ovelap Seam of Dual Pro and Tile Pro
All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified.
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed-application such as crickets,exposed valleys,
or exposed roof to.wall details
NEMO ETC,LLC. Evaluation Report P12060.02.09-R24
Certi/icate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass'Roof Underlayments;(954)233-1230 Revision 24:01/24/2018
Page 12 of 14
ONEMOjetc.
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the..repair area: Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-Ib we or,on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches,laps(min.;28 Ib roller)or small areas of the
roof that are not accessible.to a large roller or broom.
6.4.3 Tile Applications(not allowed for Polystick'Dual Pro;IR-Xe or PoNstcick MU-X)-
Reference is made to FRSA/TRI April 2012.(04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system,consisting of Base Sheet and self-adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012(04-12),Table 1.
For adhesive-set tile applications,refer to Section S.6.4 herein.
6-4.4 Two(2)Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Tile Pro,MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top-layer material. This is not a_requirement,but is allowable if a 2-ply underlayment system is desired.
Polystick MTS or MTS PLUS followed by Polystick TU P,TU Plus;TU Max,Tile Pro.or'Polyflex SAP is allowable for use
under foam-on tile systems. Limits of use are those associated with the top-layer material. This isnota requirement;
but is allowable if a 2=ply underlayment system is desired.
Elastoflex G TU,Elast"4S6 G or Elastoflex S6 G FR ;z
6.5.1 Elastoflex G TU,Elastoflex S6 G or Elastoflex 56 G.FR shall be installed in compliance with current Polyglass published.
installation requirements. For use in the applications:
✓ Elastoflex G TU is for use as an alternate to"Mineral Surface Roll Roofing" (ASTM D6380, Class M)in the"Single
Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof-systems or the Hot Asphalt
applied"Cap Sheet in the"Two.Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to"Mineral Surface Roll Roofing"(ASTM D6380,Class M)in,the"Single Ply
System" from FRSA/TRI_April 2012(04-12) beneath mechanically fastened tile,roof systems or the-Hot Asphalt.
applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI.April 2012(04-12)beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 6 FR is for use as an alternate to"Mineral Surface,Roll Roofing"(ASTM D6380,Class M)in the"Single
Ply System"from FRSA/TRI April 2012(04-12)beneath mechanically fastened tile roof systems or the Hot Asphalt
applied"Cap Sheet"in the"Two Ply.System"from FRSA/TRI April 2012(04-12)beneath mechanically'fastened the
roof systems.
6:5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or'Elastoflex S6 GTR shall be fully asphalt-applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-irfch wide, off-set
minimum 3 feet from"course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6 6 - _ l?olyflex Gor Polyflex G FR, `�
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements-
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet"in the"Two Ply System"from FRSA/TRI April
2012(04-12)beneath mechanically fastened or adhered tile roof systems(Base Sheet Limited per 5.6.3).
✓ Polyflex G FIR is:for use as an alternate to the Heat Applied"Cap Sheet" in the"Two Ply System"from FRSA/TRI
April 2012(04-12)beneath mechanically fastened tile roof systems(Base Sheet Limited per 5.6.3).
MEMO ETC,LLC. Evaluation.Report P12060.02.09-1224
Certificate oJAuthorizotion#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof.Underlayments;(954)233-1230 Revision 24:01:/24/2018
Page 13 of 14
r
NE-K.IO l etc..
6.6:2 Polyflex(G.or Polyflex G FR;shall be;fully torch-applied:to the substrates noted in.;Section 5.6. Side laps shall be
minimum 3-inch:an:&end-laps minimum .6-inch wide;off-set minimum.3 feet from.course..to course. Side and end
laps shall be_ fully heat-welded and.inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge,
6_7 Tile Staging:
6.7.1 Tile shall be loaded and staged:in-a manner.that prevents tile slippage and/oi-Aamageto the underlayment. Refer to
Table 2 herein,and Polyglass published requirements for tilestaging.
6.7.2 Baftens..and/or Counter-battens,as required by the;;t.ile manufacturer and FRSA/TRI April 201204-12)must be used
on all roof slopes greater than 7i12. Precautions should be-taken as needed, such as the use of battens or nail-
boards,.to prevehttile sliding and/or damage to the underlayment during the loading process.
6:7.3 Polyglass specifies the minimum cure time after installation of self-adhering membranes and before loading of"
roofing tiles is forty-eight(48)hours.
7. BUILDING PERMIT REQUIREMENTS:
As:required bythe Building Official or Authority Having Jurisdiction in order to properly evaluate the installation ofthis-prod uct.
S. MANUFACTURING PLANTS:
Contact.the.noted-QA.agency.for informatiom,on product locations covered for F A.C.61G20-3 QA requirements. The following
plants have;qualified products:under their respective physical properties specifications.
Fernley,NV,Hazleton,PA&•INinterHaven,FL ASTM D1970 Polystick.MU-X
Hazleton,PA M-D 13-0004 Elestoflex G TU:
ASTM D1970 PDlystick IR=Xe
Hazleton,PA&Winter Haven,;FL ASTM D1970&FRSA/TRI April.2012 PolystickTUIPlus
ASTM D1970&FRSA/TRI April 2012 Polystick TU.Max
Tuscaloosa;AL ASTM.D4601,Type II Polyglass G2 Base.
ASTM D226(physicals) Elastobas6,Elastobase P
ASTM'D6509 Polyglass APP Base
MSA/TRI Apri1:3012 Polystick.MTS,_Polystick-MTS PLUS
FRSA/TRI April 2012. -Polystj&TO P
Winter Haven;FL. FRSA/TRI April 2012- Pol ex SAP,Polyflex SAP FR.
ASTM D1970 Polystick Dual Pro
ASTM D1970&FRSA/TRI April 2012 Polysiick Tile Pro
ASTM D6164 Mmtoflex.S6,Elastoflez S6 G FR
ASTM D6222 Polyflex 6;Polyflex GFR
1.: QUALITY ASSURANCE,ENTITY:
UL,LLC—QUA9625;(314)S78-3406;k.ehancellor@us.ul.com
-END OF EVALUATION REPORT-
NEMC ETC;LLC. Evaluation Report P12060.02-097R24.
-Certijcare of Autho'Izotion#32455 6'":EDITION 12027)FBC.NON-HVHZ EVALUATION F1.5259-1128
Polyglass.Roof Und_erlayriierits;(9541233-1230 Revision:24:'01/24/2018