Loading...
HomeMy WebLinkAboutBuilding Permit ApplicationAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Permit Number: Building Permit Application Commercial Residential X PERMIT TYPE:Water Heater change out PROPOSED IMPROVEMENT LOCATION: Address: 7420 S Ocean Dr #215 Jensen Beach 34957 Property Tax ID #: 3522-604-0010-000-9 Site Plan Name: Project Name: DETAILED DESCRIPTION OF WORK: Lot No. Block No. Remove old 30 gallon electric water heater and install new 30 g1loan low boy skinny in closet under A/C CONSTRUCTION INFORMATION: Additional work to be performed under this permit— check all that apply: _Mechanical // Gas Tank _ Gas Piping ^ Shutters _ Windows/Doors Electric x Plumbing _ Sprinklers _ Generator _ Roof Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 900.00 Utilities: —Sewer —Septic Building Height: OWNERf LESSEE: CONTRACTOR: Name lvonne Mesa Name: Lonnie Culbertson Address:317 W 35th St Company: Jensen Beach Plumbing, Inc. City. Hialeah State: Address;1086 NE Industrial Blvd Zip Code: 33012 Fax: City: Jensen Beach State: FL Phone No. Zip Code: 34957 Fax: 772-225-6779 E-Mail: Phone No 772-225-6600 Fill in fee simple Title Holder on next page ( if different E-Mail mariah@jensenbeachpiumbing.com from the Owner listed above) State or County License24654 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: Not Applicable Name: MORTGAGE COMPANY: Not Applicable Name: Address: Address: City: State: Zip: Phone FEE SIMPLE TITLE HOLDER: Not Applicable Name: Address: City: State: Zip: Phone: BONDING COMPANY: Not Applicable Name: Address: City: Zip- Phone: City: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to ao the work ana ,nstanamm as rrrukcim . I certify that no work or installation has commenced prior to the issuance of a permit_ St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION_ IF YOU INTEND TO OBTAIN FINANCING, CONSULT H YOUR LENDER OR AN ATTORNEY BEFORE RECORDIN OUR NOTICE OF COMMENCEMENT." Signature of Owner/ Lessee Contractor as Agent for Owner Signature of Contractor/License Holder STATE OF FLORi STATE OF FLOR�� COUNTY OF COUNTY OF The fgrgoing ins ment was acknowiedgbefore me The fofgoing ins ent was acknowledged before me � 1 ZB� by this �-j day of 20 by this day of Name of person making statement. Name of person making statement. Personally Known OR Produced Identification Personally Known L�OR Produced Identification Type of Identification Type of Identification Produced Produced {Signature of Notary Public- State of Fd MUS ignature of Notary Public- St MARI H MILLS KiANAH 1 +�. mmissi�n # GG 100722 No. Jung 3, 2021 Co issio # GG 100722 mmission No. 3,2021 �., �x Commission , _,;�S���pi'es Fr„' „_ '•° cor,A Thr. Toy' Fa'�n I-Mlcnca 4" 101 Boroed Thar Troy Fain lrtsuranra BQ6-30N01B y�}r+orra• REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED ev. Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 7420 S OCEAN DR 215 Parcel ID: 3522-604-0010-000-9 Account #. 116000 Map lD: 35/22S Use Type: 0400 Zoning: City/County: Saint Lucie County Ownership Total Areas Orlando Ignacio Mesa Ivonne Mesa Finished/Under Air (SF): 317 W 35th ST Gross Sketched Area (SF): Hialeah, FL 33012 Land Size (acres): Legal Description Land Size (SF): SAND DOLLAR VILLAS CONDOMINMM C- UNIT 215 AND UND PRO-RATA SHAREIN COMMON ELEMENTS Current Values Just/Market Value: $217,400 Assessed Value: $205,458 Exemptions: $0 Taxable Value: $205,458 Property taxes are subject to change upon change of ownership. • Past taxes are not a reliable projection of future taxes. • The sale of a property will prompt the removal of all exemptions, assessment caps, and special classifications. Taxes for this parcel: SLC Tax Collector's Office 12 Download TRIM for this parcel: Download PDF p We History Date: Apr 29, 2019 BooklPage: 4268/2935 Sale Code: 0001 Deed: WD Grantor: Kelly (TR) Jackie Price: $252,500 Date- May 16, 2016 Book/Page: 3870 / 1578 Sale Code: 0001 Deed: WD Gmator: Murphy Sr James J Price: $204,000 Date: Nov 21, 2006 Book/Page: 2747 / 1963 Residential Electric Water Professional Classic Water Heaters 1 1 The new degree of comfort" Professional Classic electric water heaters are engineered for longer life - resistored heating elements and premium grade anode rod Efficiency •.95EF • isolated tank design reduces conductive heat loss • Resistored copper upper element and resistored Lifeguard" stainless steel lower element to prolong anode rod and tank life Performance • FHR: 42 - 71 gallons, based on gallon capacity • Recovery: 21 GPH at a 90e F rise System Sentinel (Available on selected models) • Exclusive diagnostic system with glowing LEDs that verify heating element operation. LEDs. pin point the exact location of functioning or non- functioning heating elements Longer Life • Premium grade anode rod provides long-lasting tank protection Features • Electric junction box located above heating elements for easy installation • Over -temperature protector cuts off power in excess temperature situations • Automatic thermostat keeps water at desired temperature Plus... • EverKleen'" self cleaning device fights harmful sediment build-up with a high -velocity spiraling water stream - helps operating efficiency by saving energy, money and improving tank life • Temperature and pressure relief valve included • Low lead compliant Warranty • 6-Year limited tank and parts warranty` • With ProtectionPlus" the 6--year limited tank warranty becomes 1 0-year -See Residential warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according tc the AHRI Operations Manual and D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard go, IGC Code and aR state energy efficiency performance criteria. Professional Classic 19.9 to 55-Gallon Capacities 240 Volt AC/Single Phase Double and Single Element Models Electric ti•;�s�rata��q See specifications chart on back. PRIN'rED 04 U.S.A. 0116 W P FORM NO. PROE RH N Rev. 3 The new degirw of comfort:' Professional Classic" Specifications Residential Electric Water P"Aassional Classic Water Heaters DESCRIPTION FEATURES ROUGHING IN DIMENSIONS {SHOWN IN INCHES) ENERGY INFO, TYPE GAL. CAP. MODEL NUMaeR FIRST HOUR RATING Q.P.H. RECOVERY IN G.V.H. air F RISE TANK HEIGHT A HEIGHTTG WATER CONN. 9 DIAMETER C APPROX. SHIP Wr. ILOS) ENERGY FACTOR Tao 30 PROli Y2 RH951 48 21 47-1/2 50-M 19-114 92 0.96 Tail 40 FIROE40 T2 PH951 57 21 60-314 63-5/8 19-114 109 0.96 Tall 50 PROi T2 RH95t 67 21 61 61-5/8 20-1/4 12t 0.95 Talr 55 Phi T2 RH941 71 21 57 59-314 22-114 120 0.94 Mod. 30 PROE30 M2 RH95- 44 21 37-1/2 40-12 20-114 92 0.95 Med. Med. 40 PROE40 M2 RH95 65 21 48-1/4 50-1/2 20-1/4 106 0.95 Mad. 50 PROE5O M2 RH961 65 21 48 50-1/2 23 132 0.95 Short 19.9 PAOE20 S2 PH - 21 31-1/2 31-112 17 62 - ShOA 28 PROE28 S2 RH95 42 21 30 31-1/8 23 95 0.95 Shoff 30 PROE30 82 RH95 B^ 42 21 30-1/8 32 19-3/4 95 0.95 Short 36 PROE36 52 RH95 45 21 31-1/2 3s 24-1/4 118 0.95 38 PROE38 S2 RH95 1 55 21 31 -112 1 32-518 23 108 9.95 Short 47 1 MOE47 S2 RH95 13- 55 21 32 34 1 26-414 149 10.95 Energy Factor based on D.O.E. (Department of Energy) test procedures. t System Sentinel optional. Add EC1 to the end of the model number. System Sentinel not available on single element models, available art dual element models only. System Sentinel not available in excess of 5 kW an 208 V models. Water heater dimensions prior to installing insulation blanket that Is included with water heater. • Heaters furnished with standard 240 volt AO, single phase rmn-simultaneous wiring, and 4500 watt upper and bwer healing elements. • If heating elements of different wattages than those shown are demanded by zone requirements, they must Be specHlcatH requested. • Single element models available on special order (6f)06W max.). SubstihRe "1"for "2" in modal number. • Special Wiring Options -A limited number of special wiring options are available. Consult factory for price and avatabdlty, • All models equipped with heat traps. Recovery = wattage/2,42 x temp. rise "F. Example: 450OW = 21 GPH 2.42x90xW. Recovery calculations used wo based on 4500 watt elements used in non-simullaneeus oWalion. 8" HOT WATER ° O COLD CONNECTION WATER RELIEF VALVE CONNECTII I� CONNECTION ANODE ROD i]IAI4AIU ETER Q B WATER CONNECTIONS ALL 314" N.A.T. In keephig with its policy of continuous progress and product improvement Rheem reserves the fight to make Changes without notice. RITeem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com PRINTED IN O.S.A, 05/16 wP FORM NO. PROE PH N R— 3