HomeMy WebLinkAboutDrawing, layout FILE rop
6ZECENED
DEC.0 4 1019
permitting Department
St.i.ucie Cou
I '
1
51" X 80"
REPLACE DOOR&SIDELIGHT IN 1 OPENING ONLY.
NEW DOOR&SIDELIGHT TO BE IMPACT RESISTANT-
SHUTTERS NOT REQUIRED.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 51 80 28.33 4 36.1 -39.3 FL22363.6 50.0 -50.0 FRONT ENTRY-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR&SIDELIGHT FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30%OF STRUCTURE'S VALUE.NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 13 FT 7 IN
BENNETT�RESIDENCE
5203 DEER RUN DRIVE DOOR REPLACEMENT PLAN
I
FORT PIERCE, FLORIDA
i