Loading...
HomeMy WebLinkAboutDrawing, layout FILE rop 6ZECENED DEC.0 4 1019 permitting Department St.i.ucie Cou I ' 1 51" X 80" REPLACE DOOR&SIDELIGHT IN 1 OPENING ONLY. NEW DOOR&SIDELIGHT TO BE IMPACT RESISTANT- SHUTTERS NOT REQUIRED. OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 51 80 28.33 4 36.1 -39.3 FL22363.6 50.0 -50.0 FRONT ENTRY-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR&SIDELIGHT FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30%OF STRUCTURE'S VALUE.NOT A RENOVATED BUILDING.EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 13 FT 7 IN BENNETT�RESIDENCE 5203 DEER RUN DRIVE DOOR REPLACEMENT PLAN I FORT PIERCE, FLORIDA i