Loading...
HomeMy WebLinkAboutProduct Approval (3) - " Florida Building Code Online Page 1 of 3 Business :, Professional, Regulation r�rc�rr . + w�^ SCIS Home ( Log In User Registration Hot Topics Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map I Links Search I I IUtl Product Approval :USER:Public User RECEI -•0 a M Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail DEC 0 4 2019 FL# FL14090-R10 Application Type Revision ST. Lucie County., Permitting Code Version 2017 Application.Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments public comment;Remove proprietary note.11/26/19 Archived ❑ Product Manufacturer JELD-WEN FILE Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 fbcl@jeld-wen.com. Authorized Signature Rylee Sumner Fricks fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls,OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email CategoryIgdtows Subcategory Ho�izontaf_Slider Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method - Method 1 Option A Date Submitted 09/18/2019 Date Validated 09/25/2019 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtGLR%2byCB... 12/4/2019 Florida Building Code Online Page 2 of 3 ' Date Pending FBC Approval Date Approved 10/03/2019 Summary of Products FL# Model,Number or Name Description 14090.1 Premium Atlantic Vinyl. Horizontal Slider(8200)74"x 62"Insulated Glass(3/16 in- 3/16 out Annealed) Limits"of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090 R10 C CAC NI011635-R1.13df Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 07/31/2025 Design Pressure:+50/-55 Installation Instructions Other:Windows.with insulated glass units wider than 36" FL14090 R10 II DP50-55 74x62 Installation Instructions:odf require setting blocks.Miami-Dade NOAs: Quanex Building Verified By: Hermes Norero,PE 73778 Products,Inc PVC(12-1017.02 and 13-0425.15). Created by Independent Third Party:Yes Evaluation Reports FL14090 R10 AE PER3105.odf Created by Independent Third Party:Yes 14090.2 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(3/16 in- 3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090 R10 C CAC NI011636-R1.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:.No 07/31/2025 Design Pressure:+65/-70 Installation Instructions Other:Windows with insulated glass units wider than 36" FL14090 R10 II DP65-70 74x54 Installation Instructions.odf require setting blocks.Miami-Dade NOAs: Quanex Building Verified By: Hermes Norero,PE 73778 Products,Inc PVC(12-1017.02 and 13-0425.15). Created by Independent Third Party:Yes Evaluation Reports FL14090 R10 AE PER3102.odf Created by Independent Third Party:Yes 14090.3 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 62"Insulated Glass(5/16 SGP Lam in-3/16 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090 R10 C CAC NI011681-Rl.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 08/30/2025 Design Pressure:+50/-55 Installation Instructions Other:Windows with insulated glass units wider than 36" FL14090 R10 II DP50- require setting blocks.These windows do not meet small 55 LMI 74x62 Installation Instructions.odf missile impact wind-borne requirements as required by Verified By: Hermes Norero 73778 FBC,section 2411.3.3.7 when the exterior lite is annealed. Created by Independent Third Party:Yes These windows meet small missile impact wind-borne Evaluation Reports - protection requirements as required by FBC,section FL14090 R10 AE PER3103.2df 2411.3.3.7 when the exterior lite is tempered. Miami- Created by Independent Third Party:Yes Dade NOAs: Quanex Building Products,Inc PVC(12- 1017.02 and 13-0425.15),Dupont SentryGlas Interlayer (11-0624.02). 14090.4 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(5/16 PVB Lam in- 1/8 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090 RSO C CAC NI011745-Rl.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 10/31/2025 Design Pressure:+50/-55 Installation Instructions Other:Windows with insulated glass wider than 36" FL14090 R10 II DP50- require setting blocks.These windows do not meet small 55 74x54 LMI Installation Instructions.odf missile impact wind-borne requirements as required by Verified By: Hermes Norero,PE 73778 FBC,section 2411.3.3.7 when the exterior lite is annealed. Created by Independent Third Party: Yes These windows meet small missile impact wind-borne Evaluation Reports protection requirements as required by FBC,section FL14090 R10 AE PER 3101.odf 2411.3.3.7 when the exterior lite is tempered. Miami- Created by Independent Third Party:Yes Dade NOAs: Quanex Building Products,Inc PVC(12- 1017.02 and 13-0425.15),Dupont PVB Interlayer(13- 0129.27). 14090.5 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(5/16 SGP Lam in-1/8 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes • FL14090 R10 C CAC NI011682-RI.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 08/30/2025 Design Pressure:+60/-65 Installation Instructions Other:Windows with insulated glass units wider than 36" FL14090 R10 II DP60- require setting blocks.These windows do not meet small 65 LMI 74x54 Installation Instructions.odf missile impact wind-borne requirements as required by Verified By: Hermes Norero,PE 73778 https://www.floridabuilding.org/pr/-D p_dtl.aspx?param=wGEVXQwtDgtGLR%2byCB... 12/4/20.19 Florida Building Code Online Page 3 of 3 FBC,section 2411.3.3.7 when the exterior lite is annealed. Created by Independent Third Party:Yes These windows meet small missile impact wind-borne Evaluation Reports protection requirements as required by FBC,section FL14090 R10 AE PER3104.odf 2411.3.3.7 when the exterior lite is tempered. Miami- Created by Independent Third Party:Yes Dade NOAs: Quanex Building Products,Inc PVC(12- 1017.02 and 13-0425.15),Dupont SentryGlas Interlayer (11-0624.02). 14090.6 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 62"Insulated Glass(5/16 PVB Lam in-3/16 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090 RSO C CAC NI011745.01-R1.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2025 Design Pressure:+50/-50 Installation Instructions Other:Windows with insulated glass wider than 36" FL14090 R10 II DP50 74x62 LMI Installation Instructions.odf require setting blocks.These windows do not meet small Verified By: Hermes Norero 73778 missile impact wind-borne requirements as required by Created by Independent Third Party:Yes FBC,section 2411.3.3.7 when the exterior lite is annealed. Evaluation Reports These windows meet small missile impact wind-borne FL14090 R10 AE PER2692.odf protection requirements as required by FBC,section Created by Independent Third Party:Yes 2411.3.3.7 when the exterior lite is tempered.Miami- Dade NOAs: Quanex Building Products,Inc PVC(12- 1017.02 and 13-0425.15),Dupont PVB Interlayer(13- 0129.27). 14090.7 Premium Atlantic Vinyl Horizontal Slider(8200) 111"x 54"Insulated Glass(5/16 PVB/SGP Lam in-3/16 Tempered out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090 R10 C CAC NIO13719 XOX 111x54 LMI.PDF Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2021 Design Pressure:+50/-55 Installation Instructions Other:These windows meet small missile impact wind- FL14090 R10 II PAV XOX Installs.odf borne protection requirements as required by FBC,section Verified By:Joseph A. Reed 58920 2411.3.3.7 when the exterior lite is tempered. Miami- Created by Independent Third Party: Yes Dade NOAs: Quanex Building Products,Inc PVC(12- Evaluation Reports 1017.02 and 13-0425.15),Dupont PVB Interlayet(13- FL14090 R10 AE 22068-1.odf 0129.27). Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® �.FEE] W Credit Gard Safe - https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtGLR%2byCB... 12/4/2019 398 East Dania Beach Blvd. BUILDING DROP_ 5 Suite 338 °a A Perfect Solution in Every Drop Dania Beach, FL 33004954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of JELD-WEN, inc. Premium Atlantic Vinyl Impact Horizontal Slider for Florida Product Approval Report No. 2692 Current Florida Building Code Method: 1 -A (Certification) Category: Windows Sub- Category: Horizontal Slider Product: Premium Atlantic Vinyl Impact Horizontal Slider Material: PVC Product Dimensions: 74"x 62" Prepared For: JELD-WEN, inc. 3737 Lakepol<•t Blvd. Klamath Falls, 012. 97601 .����cS F.. O 'Z �O Prepared by: - 7 Hermes F. Norero, P.E. Florida Professional Engineer#73778 T T Date:01/20/2014 0 Dr- •., O 0P' *- Contents:Evaluation Report Pages I— moi, FS Installation Details Pages 5-7 i,' ON111 I�i Digitally signed by Hermes F.Norero,P.E. Hermes F. Norero, P.E. Reason:I am approving this document Florida No. 73778 Date:2014.03.13 06:54:37-04'00' BUILDING DROPS ". A Perfect Solution in Every Drop Date: 01/20/2014 Report No: 2692 Certificate'of Authorization:29578 Manufacturer: JELD-WEN,inc.' Product Category: Windows Product Sub-Category: Horizontal Slider. Compliance Method: State Product Approval(1)(a) Product Name: Premium Atlantic Vinyl Impact Horizontal Slider 74"x 62" Scope: This is a.Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN inc. based on Method 1a of the State of Florida Product Approval, Department of Community Affairs- Florida Building Commission. Hermes F:Norero,P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein: This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions,NCTL210-3894-1-FBC,signed and sealed by Hermes.F. Norero, P.E. (FL# 73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the"High Velocity"Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current•Florida Building Code and does not require an impact resistant covering. 5. Site conditions that deviate from the details of drawing NCTL210-3894-1-FBC require further engineering analysis by a licensed engineer or registered architect. 6. See Installation Instructions NCTL210-3894-1-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No.73778 Page 2 of 7 BUILDING DROPS A Perfect Solution in Every Drop Date: 01/20/2014' Certificate of Authorization:29578 Report No: 2692 Certification Agency: The manufacturer has demonstrated compliance of window products in Accordance with the Florida Building Code for manufacturing under a Certification Agency through National Accreditation&Management Institute (FBC Organization #CER1773) Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing,performed by National Certified Testing Laboratories (FBC Organization#TST1589) Report#: NCTL-210-3894-01 Report Date: 12/02/2013 Revision Date:01/29/2014 2. Certification Agency National Accreditation&Management Institute - (FBC Organization#CER1773) Hermes F. Norero, P.E. Florida No.73778 Page 3 of 7 BUILDING DROPS A Perfect Solution in Every Drop Date: 01/20/2014 Report No: 26 o: 2692 2 Certificate of Authorization:29578 Installation: 1. Approved anchor types and substrates areas follows: Nailing Fin Installation: A. For two by(2X)wood frame substrate (Min.S.G.=0.42), use#10 Wood Screw type wood frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood framing. Through Frame Installation: A. For two by(2X)wood buck substrate(Min.S.G.=0.42), use#10 Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For concrete (Min.f'c=3000 psi)or masonry(Conforms to ASTM C90)substrate where one by(1X), non-structural,wood bucking is employed, use 3/16"diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete (Min.f'c=3000 psi)or masonry(Conforms to ASTM C90)substrate where wood bucking is NOT employed, use 3/16"diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. D. For steel stud substrate (Min 18 Ga., Fy=33 ksi), use#10 ITW TEK Screw type steel stud anchors of sufficient.length to achieve minimum 3 threads penetration beyond steel structure. Refer to Installation Instructions(NCTL210-3894-1-FBC)for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Rating Positive 50 PSF Negative 50 PSF Hermes F. Norero, P.E. Florida No.73778 Page 4 of 7 BUILDING DROPS A Perfect Solution in Every Drop Date: 0 Report Noo:: 226 014 692 Certificate of Authorization:29578 Installation Method JELD-WEN, inc. Premium Atlantic Vinyl Impact Horizontal Slider Nail Fin Installation Tasa'G.C. •vAx MAX THRu FIN WRHEH$ T3.2S'O.C. IWC.TRW FIN 52 s WINDOW VAMH(W MAX.) TYPICAL�LCVATFON WITH FASTENER SPAaN6 Hermes F. Norero, P.E. Florida No.73778 Page 5 of 7 t BUILDING DROPS Date: 01/20/2014 A Perfect Solution in Every Drop Report No: 2692 Certificate of Authorization:29578 JELD-WEN, inc. Premium Atlantic Vinyl Impact Horizontal Slider Through Frame Installation (Wood) 12.=*Q.C. W LAX. MAX.MWE FROM II II C011idllS LAX.TWU FFALE x � q T I T WMDCW wnM(7r MAX.) TYMCA4 ELEVATION WITH FASTENER SPACING Hermes F. Norero, P.E. Florida No. 73778 Page 6 of 7 S , BUILDING DROPS A Perfect Solution in Every Drop Date: 01/20/2014 Certificate of Authorization:29578 Report No: 2692 JELD-WEN, inc. Premium Atlantic Vinyl Impact Horizontal Slider Through Frame Installation (Concrete/Masonry, Steel) 10.76'0.C. 15.6'MAX. I I RAX.FME CCI�EAS 17,O.C. MM,THOU MME m -9 i -B T T WIND"WOM cyc-RAX.) TYPICAL El FYATION WIT44 FA5'TENEQ 5PACENS Hermes F. Norero, P.E. Florida No. 73778 Page 7 of 7 NOTICE OF PRODUCT CERTIFICATION A�cR CERTIFICATION NO: NI011745.01-R1 h A DATE: 12/20/2013 CERTIFICATION PROGRAM: Structural COMPANY: JELD-WEN CODE: 1822-1 REVISION DATE: 06/10/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl" 3737 Lakeport Boulevard Horizontal Slider 8200 Window(Impact) Klamath Falls, OR 97601 Configuration:XO Glazing:IG-3/16"Annealed Glass/Laminate-1/8" Annealed Glass/0.090"DuPont PVB Interlayer/l/8" .Annealed Glass Frame: W-1879mm(74.00") H-1574mm(62.00") Vent: W-939mm(37.00") H-1504mm(59.25") DLO: W-854mm(33.62") H-1485mm(58.50") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: 2394 Pa (50 psf) Negative Design Pressure: 2394 Pa(50 psf) Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3894-01 Expiration Date: November 30,2025 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124/ Fax: (804) 684-5122 I NAIL FIN INSTALLATION 11/2"MIN.EMBEDMENT W11II6"1RR0 �� 1 2 2X WOOD FRAME ii-- --- - ----` --------------- — --...--- --� tt MIN.DISTANCE MIN.DISTANCE FOR EDGE:3/4" I FOR EDGE:3/4" t,,„",X 1/4"MAX 3 2x WOOD 3 -MAX.IM SHIM SPACE FRAMEFIN , 2260.".,",mm 2 MAX .. 5.0 MM2 3.o mm SHIM I i 5H]:M SPACE 11/2"MIN. }� EMBEDMENT i GLASS BITE 13.0 mm DOW 995 GLAZING DETAIL 1 I FRAME SECTION(TYP) VERTICAL SECTION JAMB SECTION(TVP) NOTE:C.W beMa"WllgFkNI&WwdOpIiS HORIZONTAL SECTION 1/4"MAX NOTE:Caulk between NNliq FkW4 Wood OFmbq. SHIM SPACE 3 - i MIN.DISTANCE WMM WU M(74-MAX) I FOR EDGE:3/4" TYPICAL ELEVATION WITH FASTENER SPACING 1 2 2X WOOD FRAME Max Frame I DP RATINGI IMPACT 11/2'MIN.EMBEDMENT 74 x 62 +50/-50 1 YES CCS a Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida 1/2"into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 5 mm annealed/9 mm airspace/3 mm annealed/2 mm PVB by project of installation. Dupont/3 mm annealed. Digitally signed by Hermes F.Norero,P.E. 4. Use structural or composite shims where required. Reason:I am approving this document 5. Installation methods can be interchanged within the same opening. Date:2014.03.13 06:27:15-04'00' 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the P A, ' building code. window to achieve the rated design pressure up to the size limitations ��� 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE: not address the sealing consideration that may arise in different wall ��� .••' • �` ��� 01/30/2014 JE,IaWWEN 3737 Lakeport Blvd conditions. For the complete installation procedure,see the instructions � ; �,� � DRAWN BY: SCALE: Klamath Falls,OR.97601 packaged with the window or go to _. 00 D.Vezo NTS Phone: (541)882-3451 CHECKED BY: TITLE: www.jeld-wen.com/resources/installation. _ * * _ J. Kantola -o T T Q' = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: % _)3 -- Nail Fin Installation (74"x 62") This drawing and its contents are confidential and are not to be % 0 OP' P T P O E o reproduced or copied in whole or in part or used or disclosed to others �i- o�el��� ����i�t� except as authorized b JELD-WEN Inc. 398 Er _i[O1L6 338 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET p y �¢ NCTL210-3894- -FBC 10F4