HomeMy WebLinkAboutProduct Approval (3) - " Florida Building Code Online Page 1 of 3
Business :, Professional, Regulation
r�rc�rr .
+ w�^ SCIS Home ( Log In User Registration Hot Topics Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map I Links Search
I I IUtl
Product Approval
:USER:Public User RECEI -•0
a M
Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail DEC 0 4 2019
FL# FL14090-R10
Application Type Revision ST. Lucie County., Permitting
Code Version 2017
Application.Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments public comment;Remove proprietary note.11/26/19
Archived ❑
Product Manufacturer JELD-WEN FILE
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls,OR 97601
(800)535-3936
fbcl@jeld-wen.com.
Authorized Signature Rylee Sumner Fricks
fbcl@jeld-wen.com
Technical Representative JELD-WEN Corporate Customer Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls,OR 97601
(800)535-3936
customerserviceagents@jeld-wen.com
Quality Assurance Representative
Address/Phone/Email
CategoryIgdtows
Subcategory Ho�izontaf_Slider
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute
Referenced Standard and Year(of Standard) Standard Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
Product Approval Method - Method 1 Option A
Date Submitted 09/18/2019
Date Validated 09/25/2019
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtGLR%2byCB... 12/4/2019
Florida Building Code Online Page 2 of 3 '
Date Pending FBC Approval
Date Approved 10/03/2019
Summary of Products
FL# Model,Number or Name Description
14090.1 Premium Atlantic Vinyl. Horizontal Slider(8200)74"x 62"Insulated Glass(3/16 in-
3/16 out Annealed)
Limits"of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14090 R10 C CAC NI011635-R1.13df
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 07/31/2025
Design Pressure:+50/-55 Installation Instructions
Other:Windows.with insulated glass units wider than 36" FL14090 R10 II DP50-55 74x62 Installation Instructions:odf
require setting blocks.Miami-Dade NOAs: Quanex Building Verified By: Hermes Norero,PE 73778
Products,Inc PVC(12-1017.02 and 13-0425.15). Created by Independent Third Party:Yes
Evaluation Reports
FL14090 R10 AE PER3105.odf
Created by Independent Third Party:Yes
14090.2 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(3/16 in-
3/16 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14090 R10 C CAC NI011636-R1.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:.No 07/31/2025
Design Pressure:+65/-70 Installation Instructions
Other:Windows with insulated glass units wider than 36" FL14090 R10 II DP65-70 74x54 Installation Instructions.odf
require setting blocks.Miami-Dade NOAs: Quanex Building Verified By: Hermes Norero,PE 73778
Products,Inc PVC(12-1017.02 and 13-0425.15). Created by Independent Third Party:Yes
Evaluation Reports
FL14090 R10 AE PER3102.odf
Created by Independent Third Party:Yes
14090.3 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 62"Insulated Glass(5/16 SGP
Lam in-3/16 Annealed out)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14090 R10 C CAC NI011681-Rl.Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 08/30/2025
Design Pressure:+50/-55 Installation Instructions
Other:Windows with insulated glass units wider than 36" FL14090 R10 II DP50-
require setting blocks.These windows do not meet small 55 LMI 74x62 Installation Instructions.odf
missile impact wind-borne requirements as required by Verified By: Hermes Norero 73778
FBC,section 2411.3.3.7 when the exterior lite is annealed. Created by Independent Third Party:Yes
These windows meet small missile impact wind-borne Evaluation Reports -
protection requirements as required by FBC,section FL14090 R10 AE PER3103.2df
2411.3.3.7 when the exterior lite is tempered. Miami- Created by Independent Third Party:Yes
Dade NOAs: Quanex Building Products,Inc PVC(12-
1017.02 and 13-0425.15),Dupont SentryGlas Interlayer
(11-0624.02).
14090.4 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(5/16 PVB
Lam in- 1/8 Annealed out)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14090 RSO C CAC NI011745-Rl.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 10/31/2025
Design Pressure:+50/-55 Installation Instructions
Other:Windows with insulated glass wider than 36" FL14090 R10 II DP50-
require setting blocks.These windows do not meet small 55 74x54 LMI Installation Instructions.odf
missile impact wind-borne requirements as required by Verified By: Hermes Norero,PE 73778
FBC,section 2411.3.3.7 when the exterior lite is annealed. Created by Independent Third Party: Yes
These windows meet small missile impact wind-borne Evaluation Reports
protection requirements as required by FBC,section FL14090 R10 AE PER 3101.odf
2411.3.3.7 when the exterior lite is tempered. Miami- Created by Independent Third Party:Yes
Dade NOAs: Quanex Building Products,Inc PVC(12-
1017.02 and 13-0425.15),Dupont PVB Interlayer(13-
0129.27).
14090.5 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(5/16 SGP
Lam in-1/8 Annealed out)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes • FL14090 R10 C CAC NI011682-RI.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 08/30/2025
Design Pressure:+60/-65 Installation Instructions
Other:Windows with insulated glass units wider than 36" FL14090 R10 II DP60-
require setting blocks.These windows do not meet small 65 LMI 74x54 Installation Instructions.odf
missile impact wind-borne requirements as required by Verified By: Hermes Norero,PE 73778
https://www.floridabuilding.org/pr/-D p_dtl.aspx?param=wGEVXQwtDgtGLR%2byCB... 12/4/20.19
Florida Building Code Online Page 3 of 3
FBC,section 2411.3.3.7 when the exterior lite is annealed. Created by Independent Third Party:Yes
These windows meet small missile impact wind-borne Evaluation Reports
protection requirements as required by FBC,section FL14090 R10 AE PER3104.odf
2411.3.3.7 when the exterior lite is tempered. Miami- Created by Independent Third Party:Yes
Dade NOAs: Quanex Building Products,Inc PVC(12-
1017.02 and 13-0425.15),Dupont SentryGlas Interlayer
(11-0624.02).
14090.6 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 62"Insulated Glass(5/16 PVB
Lam in-3/16 Annealed out)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14090 RSO C CAC NI011745.01-R1.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 11/30/2025
Design Pressure:+50/-50 Installation Instructions
Other:Windows with insulated glass wider than 36" FL14090 R10 II DP50 74x62 LMI Installation Instructions.odf
require setting blocks.These windows do not meet small Verified By: Hermes Norero 73778
missile impact wind-borne requirements as required by Created by Independent Third Party:Yes
FBC,section 2411.3.3.7 when the exterior lite is annealed. Evaluation Reports
These windows meet small missile impact wind-borne FL14090 R10 AE PER2692.odf
protection requirements as required by FBC,section Created by Independent Third Party:Yes
2411.3.3.7 when the exterior lite is tempered.Miami-
Dade NOAs: Quanex Building Products,Inc PVC(12-
1017.02 and 13-0425.15),Dupont PVB Interlayer(13-
0129.27).
14090.7 Premium Atlantic Vinyl Horizontal Slider(8200) 111"x 54"Insulated Glass(5/16
PVB/SGP Lam in-3/16 Tempered out)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14090 R10 C CAC NIO13719 XOX 111x54 LMI.PDF
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 04/30/2021
Design Pressure:+50/-55 Installation Instructions
Other:These windows meet small missile impact wind- FL14090 R10 II PAV XOX Installs.odf
borne protection requirements as required by FBC,section Verified By:Joseph A. Reed 58920
2411.3.3.7 when the exterior lite is tempered. Miami- Created by Independent Third Party: Yes
Dade NOAs: Quanex Building Products,Inc PVC(12- Evaluation Reports
1017.02 and 13-0425.15),Dupont PVB Interlayet(13- FL14090 R10 AE 22068-1.odf
0129.27). Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
® �.FEE] W
Credit Gard
Safe -
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtGLR%2byCB... 12/4/2019
398 East Dania Beach Blvd.
BUILDING DROP_ 5 Suite 338
°a A Perfect Solution in Every Drop Dania Beach, FL 33004954.399.8478 PH
Certificate of Authorization:29578 954.744.4738 FX
contact@buildingdrops.com
Product Evaluation Report
Of
JELD-WEN, inc.
Premium Atlantic Vinyl
Impact Horizontal Slider
for
Florida Product Approval
Report No. 2692
Current Florida Building Code
Method: 1 -A (Certification)
Category: Windows
Sub- Category: Horizontal Slider
Product: Premium Atlantic Vinyl
Impact Horizontal Slider
Material: PVC
Product Dimensions: 74"x 62"
Prepared For:
JELD-WEN, inc.
3737 Lakepol<•t Blvd.
Klamath Falls, 012. 97601 .����cS F.. O
'Z �O
Prepared by: - 7
Hermes F. Norero, P.E.
Florida Professional Engineer#73778 T T
Date:01/20/2014 0 Dr- •., O 0P' *-
Contents:Evaluation Report Pages I— moi, FS
Installation Details Pages 5-7 i,' ON111 I�i
Digitally signed by Hermes F.Norero,P.E. Hermes F. Norero, P.E.
Reason:I am approving this document Florida No. 73778
Date:2014.03.13 06:54:37-04'00'
BUILDING DROPS
". A Perfect Solution in Every Drop Date: 01/20/2014
Report No: 2692
Certificate'of Authorization:29578
Manufacturer: JELD-WEN,inc.'
Product Category: Windows
Product Sub-Category: Horizontal Slider.
Compliance Method: State Product Approval(1)(a)
Product Name: Premium Atlantic Vinyl Impact Horizontal Slider
74"x 62"
Scope: This is a.Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN inc.
based on Method 1a of the State of Florida Product Approval, Department of Community Affairs-
Florida Building Commission.
Hermes F:Norero,P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein:
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions,NCTL210-3894-1-FBC,signed and sealed by Hermes.F. Norero, P.E. (FL#
73778)for specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the"High Velocity"Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Section 1609.1.2 of the current•Florida Building Code and does not require an impact
resistant covering.
5. Site conditions that deviate from the details of drawing NCTL210-3894-1-FBC require further
engineering analysis by a licensed engineer or registered architect.
6. See Installation Instructions NCTL210-3894-1-FBC for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida No.73778
Page 2 of 7
BUILDING DROPS
A Perfect Solution in Every Drop Date: 01/20/2014'
Certificate of Authorization:29578
Report No: 2692
Certification Agency: The manufacturer has demonstrated compliance of window products in Accordance
with the Florida Building Code for manufacturing under a Certification Agency
through National Accreditation&Management Institute (FBC Organization
#CER1773)
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
Referenced Data:
1. Product Testing,performed by National Certified Testing Laboratories
(FBC Organization#TST1589)
Report#: NCTL-210-3894-01 Report Date: 12/02/2013
Revision Date:01/29/2014
2. Certification Agency
National Accreditation&Management Institute
- (FBC Organization#CER1773)
Hermes F. Norero, P.E.
Florida No.73778
Page 3 of 7
BUILDING DROPS
A Perfect Solution in Every Drop Date: 01/20/2014 Report No: 26 o: 2692 2
Certificate of Authorization:29578
Installation: 1. Approved anchor types and substrates areas follows:
Nailing Fin Installation:
A. For two by(2X)wood frame substrate (Min.S.G.=0.42), use#10 Wood Screw type wood
frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood
framing.
Through Frame Installation:
A. For two by(2X)wood buck substrate(Min.S.G.=0.42), use#10 Wood Screw type
installation anchors of sufficient length to achieve a minimum embedment of 1.50" into
the wood substrate.
B. For concrete (Min.f'c=3000 psi)or masonry(Conforms to ASTM C90)substrate where
one by(1X), non-structural,wood bucking is employed, use 3/16"diameter ITW Tapcon
type concrete screw anchors of sufficient length to achieve minimum embedment of
1.25" into concrete or masonry.
C. For concrete (Min.f'c=3000 psi)or masonry(Conforms to ASTM C90)substrate where
wood bucking is NOT employed, use 3/16"diameter ITW Tapcon type concrete screw
anchors of sufficient length to achieve minimum embedment of 1.25"into concrete or
masonry.
D. For steel stud substrate (Min 18 Ga., Fy=33 ksi), use#10 ITW TEK Screw type steel stud
anchors of sufficient.length to achieve minimum 3 threads penetration beyond steel
structure.
Refer to Installation Instructions(NCTL210-3894-1-FBC)for anchor spacing and more details of the
installation requirements.
Design Pressure:
Design Pressure Rating
Positive 50 PSF
Negative 50 PSF
Hermes F. Norero, P.E.
Florida No.73778
Page 4 of 7
BUILDING DROPS
A Perfect Solution in Every Drop Date: 0
Report Noo:: 226 014
692
Certificate of Authorization:29578
Installation Method
JELD-WEN, inc.
Premium Atlantic Vinyl Impact Horizontal Slider
Nail Fin Installation
Tasa'G.C. •vAx
MAX THRu FIN
WRHEH$
T3.2S'O.C.
IWC.TRW
FIN
52
s
WINDOW VAMH(W MAX.)
TYPICAL�LCVATFON WITH FASTENER SPAaN6
Hermes F. Norero, P.E.
Florida No.73778
Page 5 of 7
t
BUILDING DROPS
Date: 01/20/2014
A Perfect Solution in Every Drop Report No: 2692
Certificate of Authorization:29578
JELD-WEN, inc.
Premium Atlantic Vinyl Impact Horizontal Slider
Through Frame Installation (Wood)
12.=*Q.C. W LAX.
MAX.MWE FROM
II II C011idllS
LAX.TWU
FFALE
x
� q
T I T
WMDCW wnM(7r MAX.)
TYMCA4 ELEVATION WITH FASTENER SPACING
Hermes F. Norero, P.E.
Florida No. 73778
Page 6 of 7
S ,
BUILDING DROPS
A Perfect Solution in Every Drop Date: 01/20/2014
Certificate of Authorization:29578 Report No: 2692
JELD-WEN, inc.
Premium Atlantic Vinyl Impact Horizontal Slider
Through Frame Installation (Concrete/Masonry, Steel)
10.76'0.C. 15.6'MAX.
I I RAX.FME CCI�EAS
17,O.C.
MM,THOU
MME
m
-9
i
-B
T T
WIND"WOM cyc-RAX.)
TYPICAL El FYATION WIT44 FA5'TENEQ 5PACENS
Hermes F. Norero, P.E.
Florida No. 73778
Page 7 of 7
NOTICE OF PRODUCT CERTIFICATION
A�cR CERTIFICATION NO: NI011745.01-R1
h A
DATE: 12/20/2013
CERTIFICATION PROGRAM: Structural
COMPANY: JELD-WEN
CODE: 1822-1
REVISION DATE: 06/10/2017
To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the
product is active and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
JELD-WEN "Premium Atlantic Vinyl"
3737 Lakeport Boulevard Horizontal Slider 8200 Window(Impact)
Klamath Falls, OR 97601
Configuration:XO
Glazing:IG-3/16"Annealed Glass/Laminate-1/8"
Annealed Glass/0.090"DuPont PVB Interlayer/l/8"
.Annealed Glass
Frame: W-1879mm(74.00") H-1574mm(62.00")
Vent: W-939mm(37.00") H-1504mm(59.25")
DLO: W-854mm(33.62") H-1485mm(58.50")
SPECIFICATION PRODUCT RATING
TAS 201/202/203-94 Design Pressure: 2394 Pa (50 psf)
Negative Design Pressure: 2394 Pa(50 psf)
Large Missile Impact Rated
Product Tested By: National Certified Testing Laboratories
Report No: NCTL-210-3894-01
Expiration Date: November 30,2025
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124/ Fax: (804) 684-5122
I
NAIL FIN INSTALLATION
11/2"MIN.EMBEDMENT
W11II6"1RR0 �� 1 2 2X WOOD FRAME ii-- --- - ----` --------------- — --...--- --�
tt
MIN.DISTANCE MIN.DISTANCE
FOR EDGE:3/4" I FOR EDGE:3/4"
t,,„",X 1/4"MAX 3 2x WOOD 3
-MAX.IM SHIM SPACE FRAMEFIN
,
2260.".,",mm 2 MAX
.. 5.0 MM2 3.o mm SHIM
I i 5H]:M SPACE
11/2"MIN.
}� EMBEDMENT
i GLASS BITE
13.0 mm
DOW 995
GLAZING DETAIL 1
I
FRAME SECTION(TYP)
VERTICAL SECTION JAMB SECTION(TVP)
NOTE:C.W beMa"WllgFkNI&WwdOpIiS HORIZONTAL SECTION
1/4"MAX NOTE:Caulk between NNliq FkW4 Wood OFmbq.
SHIM SPACE 3 -
i MIN.DISTANCE
WMM WU M(74-MAX) I FOR EDGE:3/4"
TYPICAL ELEVATION WITH FASTENER SPACING 1 2 2X WOOD FRAME Max Frame I DP RATINGI IMPACT
11/2'MIN.EMBEDMENT 74 x 62 +50/-50 1
YES
CCS
a
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use#10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
1/2"into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 5 mm annealed/9 mm airspace/3 mm annealed/2 mm PVB by
project of installation. Dupont/3 mm annealed.
Digitally signed by Hermes F.Norero,P.E. 4. Use structural or composite shims where required.
Reason:I am approving this document 5. Installation methods can be interchanged within the same opening.
Date:2014.03.13 06:27:15-04'00' 6. An impact protective system is not required where wind borne debris protection is mandated by local
This schedule addresses only the fasteners required to anchor the P A, ' building code.
window to achieve the rated design pressure up to the size limitations ��� 7. Maximum sizes are buck sizes and do not include fin or flange.
noted. It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE:
not address the sealing consideration that may arise in different wall ��� .••' • �` ��� 01/30/2014 JE,IaWWEN 3737 Lakeport Blvd
conditions. For the complete installation procedure,see the instructions � ; �,� � DRAWN BY: SCALE: Klamath Falls,OR.97601
packaged with the window or go to _. 00
D.Vezo NTS Phone: (541)882-3451
CHECKED BY: TITLE:
www.jeld-wen.com/resources/installation. _ * * _ J. Kantola
-o T T Q' = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider
DISCLAIMER: % _)3 -- Nail Fin Installation (74"x 62")
This drawing and its contents are confidential and are not to be % 0 OP' P T P O E o
reproduced or copied in whole or in part or used or disclosed to others �i- o�el��� ����i�t�
except as authorized b JELD-WEN Inc. 398 Er _i[O1L6 338 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET
p y �¢ NCTL210-3894- -FBC 10F4