Loading...
HomeMy WebLinkAboutProduct Approval (5) 398 East Dania Beach Blvd. BUILDING DROPS Suite 338 A Perfect Solution in Every Drop! Dania Beach, FL 33004 ' Certificate of Authorization:29578 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report RECEIVED Of DEC 0 4 2019 Silver Line Building Products ST, Lucie County, Permitting Series 70— Extruded Vinyl lSingle Hung-Window (Impact Rated) 129 for FILL'. LROPY Florida Product Approval FL# EL171 Report No. 48 Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Windows Sub—Category: Single Hung Product: Series 70 Single Hung Window Material: PVC Product Dimensions: See Installation Instructions,SWD011 Prepared for: Silver Line Building Products One Silverline Dr. North Brunswick, NJ 06902 StF 0���''' Prepared by: �,Q` '''• •F.p ''; Hermes F. Norero, P.E. . o 7 Florida Professional Engineer#73778 Date: 12/15/2017411 Z. Contents: ��� F` ''•••....•••.•'��Z`�. Evaluation Report Pages 1-4 �iSS/ONM- Digitally signed by Hermes F.Norero,P.E. Hermes o Md0,%P.E. Reason:I am approving this document Florida No. 73778 Date:2017.12.18 18:31:30-05'00' i /QA\\ BUILDING DROPS FL#: FL19715 A Perfect Solution in Every Drop! Date: 12/15/2017 Certificate of Authorization:29578 Report No: 4806 Manufacturer: Silver Line Building Products Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(d) Product Name: Series 70 Single Hung Window Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for Silver Line Building Products based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation-Florida Building Commission. Hermes F. Norero, P.E.does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD011,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has,been evaluated and is in compliance with the Current Florida Building Code, including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown.on details. Anchor embedment into substrate material shall be beyond wall dressing or.stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. 4. Site conditions'that deviate from the details of drawing SWD011 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions SWD011 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No.73778 Page 2 of 4 BUILDING DROPS FL#: FL19715 A Perfect Solution in Every Drop! Date: 12/15/2017 z., Certificate of Authorization:29578 Report No: 4806 Quality Assurance: The manufacturer has demonstrated 'compliance of window products in Accordance with the Florida Building Code and State Rules for manufacturing under a quality assurance program audited by an approved quality assurance entity through Window and Door Manufacturers Association (FBC Organization#:QUA2515). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06/09/12 • AAMA/WDMA/CSA 101/I.S.2/A440-08 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories, Inc. (FBC Organization# TST1589)' Report: Dated: NCTL 110-16327-1 08/13/2013 NCTL'110-16327-2 11/05/2013 NCTL 110-16327-3 08/13/2013 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization#:QUA2515) 3. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance with AAMA 303 Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 BUILDING DROPS FL#: FL19715 A Perfect Solution in Every Drop! Date: 12/15/2017 Report No: 4806 Certificate of Authorization:29578 Installation: 1. Approved anchor types and substrates areas follows: Nailing Fin Installation: A. For two by'(2X)wood frame substrate(Min.S.G.=0.55), use#8 PH Wood.Screw OR-11 Gauge Roofing Nails OR 10d Common Nails type wood frame anchors of sufficient length to achieve minimum embedment of 1.50"into wood framing. B. For steel stud substrate(Min 18 Ga., Fy=33 ksi), use#8 TEK PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. Through Frame Installation: A. ,For two by(2X)wood buck substrate(Min.S.G.=0.55),use#10 PH Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For concrete(Min.f c=3000 psi)or masonry(Conforms to ASTM C90)substrate where one by(1X), non-structural,wood bucking is employed, use 3/16"diameter ITW HWH Tapcon type concrete screw anchors of sufficient length.to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete(Min.f =3000.psi)or masonry(Conforms to ASTM C90)substrate where wood-bucking is NOT employed, use 3/16"diameter ITW HWH Tapcon type concrete screw anchors_of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. D. For steel stud substrate (Min 18 Ga., Fy=33 ksi), use#10 TEK PH or HWH Screw type steel stud anchors of sufficient length to achieve minimum 3 threads penetration beyond steel structure. Refer to Installation Instructions(SWD011)for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions(SWD011)for anchor spacing and more details of the installation requirements. Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4 Silver Line SILVER LINE BUILDING PRODUCTS bJAi ' V1 SERIES170 SERIES SINGLE HUNG WINDOW (2127) ONE SILVERUNEDRNE NORTH BRUNSWIM W 08907 (IMPACT RA TED) FH: 734-0278 tD Z tD n �3 00 Of � $� NOo Fz 03m�Syt oz s� Zss �3 az ooh=""® GENERAL NOTES: z 1. THE PRODUCT SHOWN HEREIN 15 DESIGNED AND MAX OVERALLS17E TABLE OF CONTENTS N= MANUFACTURED TO COMPLY WITH THE 6DESIGN 6TH EDITION CONFIG. MISSILE 5 o 01 WIDTH HEIGHT PRESSURE IMPACT RATING SHEET REVISION SHEET DESCRIPTION w FLORIDA BUILDING CODE(FBC),INCLUDING HVHZ AND HAS m BEEN EVALUATED ACCORDING TO THE FOLLOWING: L w • TAS 201-94 52" 73" O/X +55/-60 PSF LMI/SMI 1 - GENERAL NOTES&GLAZING DETAIL I • TAS 202-94 2 I'_ • TAS 203-94 - - ELEVATION&ANCHOR LAYOUTS • ASTM E330-02 3 - VERTICAL SECTIONS REMARKS BY DATE • ASTM E1886-05 6TH Fac EDMON LM 06/14/17 • ASTM E1996.06/09/12 4 - HORIZONTAL SECTIONS • AAMA/WDMA/CSA 101/1.5.2/A440-08 5 HORIZONTAL&VERTICAL SECTIONS,INSTALLATION NOTES& REINFORCEMENT DETAILS 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY,2X FRAMING,AND METAL FRAMING _ o ASA MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF ANDSILLLLNOf BEREPRDOD®IN WHdF DRPAAf WITHSTANDING AND TRANSFERRING APPLIED PRODUCT YAt rons�,aoom�o H`CHU MNnN%ORRMa� LOADSTOTHE FOUNDATION ISTHE RESPONSIBWTYOFTHE - "h NGSTCTuioruaN¢R�r"NMPM7MDMD -ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF ' INSTALLATION. Digd on signed by q s.F.Noreroobppme,t 43/64"O.A.I.G.LAMINATED GLASS Reason:I Q3lbp�o m-gRM1,ttpfy�ment CONSISTING OF: Date:2 i22�855:��57,� 3. 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND ♦ N` R i ANCHORED AS SPECIFIED HEREIN.REFER TO SHEETS FOR 1/8"ANNEALED GLASS `♦♦�Q' :�`��� FURTHER DETAILS OF BUCK INSTALLATION. - 7/32"STEEL SPACER O 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE 0.090 ANNEALED GLASS '] _ _ 0.090"SAFLEX PVB INTERLAYER BY GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR EASTMAN CHEMICAL COMPANY A SPECIFIC SITE.IF SITE CONDITIONS CAUSE INSTALLATION3/32"ANNEALED GLASS S 13 / TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, , O •• ( OP;' [(/1 F A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE ��'C ••.•„ ...•SPEC ♦♦ S FOR USE WITH THIS DOCUMENT IN NONIFIC HVHZ AREAS.NHN VHZ AREAS,ONE TIME PRODUCTEXTERIOR // \\ INTERIOR i��''/,5'�ONAL�?G♦♦♦♦ AHPROVALTO BE OBTAINED FROM MIAMI-DADE RER OR ' }I WjI�eA.1 PE FLOMOA PM No 737m IBLn DNO CROP&INC 9 5. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED HBe a DANu eFAot e3 ITB ON THIS PRODUCT IN AREAS REQUIRING IMPACT DANu eEAa.n STEEL SPACER FBPE CERT.OF AUMOM7ATMN Nn 29M RESISTANCE. FL B: 1/8"OR 3/32" MIN.GLASS F L19715 " 6. WINDOW FRAME MATERIAL:PVC - u BITE 7/16" SETTING BLOCK 7. IN ACCORDANCE WITH THE 6TH EDITION FBC,WOOD DOW 995 SEALANT DATE: 12,11.17 COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED - DWG.BY: CHK.BY: CHAPTEROR SHALL BE 23.OFADURABLE SPEC IESASDEFINED IN GLAZING DETAIL LMS HFN 8. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 NOTE: SCALE: NTS GLASS CHARTS.SEE SHEET 5 FOR GLAZING DETAILS. ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH DWG.tI: SWD011 SAFETY GLAZING REQUIREMENTS OUTLINED IN SHEET: CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. OF 5 Silver Line _ MMderseri ONE SILVERLINE DRIVE NORM BRUNSWICK,NJ 08902 PH:800 2364228 w U m MAX.O.A FRAME o WIDTH 52" n s a MAX.D.L.O. , o K Q 2 WIDTH 47.69" X _ w 0 u 2i 2; 3"MAX. 6"MAX. 6.25"MAX. �, o z 3 3FROM D.C. '� I a CORNERSCORNERS �3�r 16J W Z, w o j F CO NOTE: >x m ALL FASTENERS ABOVE W THE MEETING RAIL IN d a a D "jam THE INTERIOR JAMB q 6"MAX.J TRACK MUST BE FLAT HEAD �' a HEIGHT33.500" C 0 D.C. REMARKS BY DATE 4 STH F8C EDOION LM 06/16/17 12.50"MAX. O.C. MAX.0 FRAME HEIGHT 73" t OOLOMFN 1NEPROP NOfB I I w 1 OV N0(BEREPRODU0:91NWfN11FO0.PART MTHO�MV,IFN MARDECONSEN, DONINC AMwNNGG.0OR NS.M DONMEM APE NOT PERMITTED AND MAX.D.L.O. "X" 3"MAX. 6.25"MAX. IwtIOATE R RTFIGN HEIGHT33.50" FROM FROM CORNERS CORNERS L F 11/0''���i T 7 ELEVATION ANCHOR LAYOUT ANCHOR LAYOUT �0%/ � . SINGLE HUNG WINDOW NAIL FIN-SINGLE HUNG WINDOW_ THROUGH FRAME-SINGLE HUNG WINDOW �� ss/' NAL FLORIDA Py. WLDI PG OP.INC BUN»Jo DROPS we 3➢E E DAMA DANK BP.1CN.6EAC1LBIM. 318 E nwE CRL 4 AUTHOR"An011 N.3967E FL q: FL19715 DATE: 12.11.17 P DWLIVIS CHK.BY: SCALE: NTS DWG.#: SWD011 SHEET: OF 5 Silver Line byAncWiWd t 11 ONE SILVERUNE DRIVE NORTX BRUNSWICK,N108902 PX:18001234-4228 d \\ \\ NN o Aga w o SEE GLAZING SEE GLAZINGW^ U a a oz zss�g DETAIL,SHEET 1 DETAIL,SHEET 1 2 m O O > w `a a H F- a REMARKS _ BY DATE _ ] S 6TXF8CEDMON LM 06/14/17 L7 I l7 Z 2 EXTERIORINTERIOR EXTERIOR INTERIOR 4x0 SNP4Lxm DERFNMW0FOINW GDR0 W X X WIINOU(WNTIFN EDNSENf Of&IILDING DR03,WG �LTE1SONT,MDIiIDNS.xIGHUGNfIN1:a lA MARDNGG l0 THIS CONMEM APE NOT PERNUIEEO IJlO NVAUDI OUR CTRxxcwTgN. ry0 ° 4 ````rhe 0 0 7 SEE GLAZING SEE GLAZING � — DETAIL,SHEET 1 DETAIL,SHEET 1 0••.,.( �` NAL`E�G� ,R22W65TWN.73M �io,`PE � aP.E. ace E.M DANU B WRwR M3 MHPE E AM FM D:AT.Or AUiNORRRAilO!Nu 2ce7e e FLM FL19715 DATE: 12.11.17 DWG.BY: CHK.BY: LMS HFN SCALE: NTS DWG.a: SWD011 A VERTICAL SECTION g VERTICAL SECTION SHEET: � 3 3 OF 5 Silver Line y MAnAe7'Wd ONE SIWERUNE DRIVE NORTH BRUNSUMNJO8902 PH:800 2344228 SECTION FOR INTERIOR SECTION FOR BLOCK&TACKLE SEE GLAZING SEE GLAZING CONSTANT FORCE „ti z a t3 BALANCERS o\ DETAIL SHEET 1 DETAIL SHEET 1 BALANCERS 5 z e a - I - 1 / 0 OO OO Oj C oz W U. N MIRW / O m EXTERIOR u a W D.L.O. F i REMARKS BY DATE MAX.FRAME WIDTH BTNFOC EDITON LM D6/24/17 HORIZONTAL SECTION 4 FIXED JAMB G ANO EHALL NOT DE REPRO W®N NNOIE OR pAR7 WRNOIRMM}iENmNgXTOi&IRIRNG DROPS,LYG AITDUtA)NG,ADDOIONS,HIGNNGHIING,OR OIHFR SEE GLAZING SEE GLAZING NURDNGSTD_iLLipDDAhCUDpe�E TMNmPERMDSEO AND DETAIL SHEET 1 INTERIOR DETAIL SHEET 1 EXTERIOR << F D.L.O. - Ima�4!AI14hQL P.E. LOMA PE Ne 73770 ImDNO DROP;No 390 E OAIM BE'AO'aI333 MAX.FRAME WIDTH DANIA BEACH IL 3300{ FBPE CMt..OF AUiH0f07AMON Hu 29M FL#: p HORIZONTAL SECTION FL19715 4 FIXED JAMB DATE: 12.11.17 DWG.BY: CHK.BY: LMS HFN SCALE: NTS DWG.#: SWD011 SHEET: OF 5 MIN. SUBSTRATE 1/4"MAX. SHIM SPACE SUBSTRATE MIN.EMBEDMENT SUBSTRATE Silver Line �{ EDGE DISTANCE BY OTHERS INTERIOR 3 BY OTHERS BY OTHERS MAn Je`r3en SCREW IN THE INTERIOR o CHANNEL MIN. MIN. EDGE DISTANCE w w EMBEDMENT u ONE eILVERUNE DRIVE SCREW IN THE EXTERIOR ,�R,Z NORTH BRUNSWIMNJ08902 /m?zCHANNEL 2 N PX:8m 23d-0718 PERIMETER SEALANT 1/4"MAX BY OTHERS SHIM SPACE PERIMETER SEALANT -)` o z BY OTHERS 1/4"MAX. z^N Fi-a� I EXTERIOR MIN. SHIM SPACE N V J�t O Q. e EXTERIOR INTERIOR EXTERIOR INTERIOR �+ o 11 2 EMBEDMENT m 3 s Z 0,56A.2 A VERTICAL SECTION wO ~Zw ���xa g HORIZONTAL SECTION HORIZONTAL SECTION o >°W z d 6 THROUGH FRAME(HEAD) 6 THROUGH FRAME(JAMB) 6 NAIL FIN(HEAD) (Da a o m H R O=? t m N= N—W m 1/4"MAX. REINFORCEMENT DETAILS > = a /a SUBSTRATM SPACE �—�{ 0 34" 'LLT 6 \ BY OTHERS 0.83" 0 87" Is, INTERIOR 2 -i - �7�� 0.13" REMARKS BY DATE Z o - INTERIOR 7T Ll� 0'9-11 I } _I 0.46„ STH FOC EDITION LM 06/I4/17 0.06" 0.167" w 7EXTERIOR 0.45" m w r 1 O LOCK RAIL ALUMINUM O� ALUMINUM LOCK ING RAIL O BOTTOM RAIL&SASH z 1 EXTERIOR ATEMTY HS,AOD ON HIGI—IATNG,OROTNTR MRrtGncsro Txt,00a1MEMARE nOTPOV.DREOAxD ixvuiGATEauR unox MIN.EDGE DISNCE HORIZONTAL SECTION VERTICAL SECTION A`,iJLILLJ„J, 6 NAIL FIN(JAMB) 6 MEETING STILE Z: 011 INSTALLATION NOTES: ANCHOR SCHEDULE _ _ _ ¢ METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT MIN.EDGE 1. ONE(1)INSTALLATION ANCHOR IS REQUIRED A7 EACH ANCHOR LOCATION SHOWN. _ DISTANCE T/ZT j 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR WOOD:MIN.SG-0.55 #8 PAN t.s 0.7s PRODUCT INSTALLATION OFTHE MAXIMUM SIZE LISTED. NAILING FIN /T� "N.At- METAL:,BGAUGE=33KSI Steel. IXB TEK SCREW THREADS MIN // tSsn •�G`�� 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN ATOLERANCE OFt1/2INCH THE DEPICTED LOCATION& MIN.Fy=33K51 PENETRMEONALBEYOND aso' /I'll �ONAL- SPACING IN THE ANCHOR LAYOUT DETAILS(I.E.,WITHOUT CONSIDERATION OF TOLERANCES).TOLERANCES AREImel�44IIkNHA��E #10 PAN HEAD INORR)A P.E.Na 7377e i NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. EXTERIORCHANNEL I.S.• 0.75' M=IN DROPS.WC Sce C DANIA eEAW RID. 339 WOOD:MIN.SG=0.55 A. BEACH,FI 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S).MAXIMUM ALLOWABLE SHIM FBPE CERT.OF AUTHORQATION Na.2De7e STACK TO BE 3/8 INCH.SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS.SHIM(S)SHALL BE CONSTRUCTED #10 OR CCHHANNNEELLE s 0.75- FL p: OF HIGH DENSITY PLASTIC OR BETTER. 3 THREADS MIN r �J 010 PAN HEAD IN C L 1 9 7 1 C S. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES,INCLUDING BUT NOT LIMITED TO STUCCO, EXTERIOR CHANNEL PENETRATION BEYOND 0.50• FOAM,BRICK VENEER,AND SIDING. THROUGH FRAME METAIL IS GAUGE Steel, MET'u DATE: 12.11.17 MIN.Fy=33KS1 3 THREADS MIN 010TFLAT ERJORHEAD INTHE DWLMS CH fiFN � 6. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL ORINTERIOR CHANNEL PENETRATION BEYOND as0• HAVE A CORROSION RESISTANT COATING. METAL 7. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. CONCRETE'e-300OPSI 16-T� 1.2s 7.7s SCALE: NTS .L EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. DWG.II: SWD011 8. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION MASONRY:CMU Pe,ASTM 3116'TTW TAPCON 12W 1.75* SHEET: INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM CSO MIN.2000 PSI FLAT HEAD STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 9. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK,USE FLAT HEAD ANCHORS. OF 5