Loading...
HomeMy WebLinkAboutProduct Approval (6) f -;Florida Building Code Online Page 1 of 2 e. Professional Regulation SCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications Contact Us Links I Search RECVC� Product Approval USER:Public Userro DEC 0 4 2019 a Product Approval Menu>Product or Aoolication Search>Application List>Application Detail ST. Lucie County., Permitting FL# FL21705-112 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments CO P'u 'ff Archived ❑ Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 fbcl@jeld-wen.com Authorized Signature Rylee Sumner Fricks fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls,OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors � •- Subcategory Sliding��Extenor'Doo—rAssemblies" Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich,PE © Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2008 ASTM E1886 2013 ASTM E1996 2014 Equivalence of Product Standards Certified By Approved Evaluation Entity FL21705 R2 Equiv Equiv 2016-01 Tech Bulletin E1996 Eguivalency.pdf FL21705 R2 Equiv Equiv WDMA E1886 JELD-WEN 5 6 2016.pdf Product Approval Method Method 1 Option A Date Submitted 01/25/2018 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param--wGEVXQwtDqulXQ6Wb7W.... 12/4/2019 Florida Building Code Online Page 2 of 2 Date Validated 02/12/2018 Date Pending FBC Approval Date Approved 02/17/2018 Summary of Products i FL# Model,Number or Name Description 21705.1 Premium Vinyl(V-4500) Multi-Slide Patio Door 283.75'x 96"Insulated Glass(3/16" out Tempered-5/16"SGP Lam in)(XXXXXX) Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL21705 R2 C CAC XXXXXX LC-PG50 353x96 DP- Approved for use outside HVHZ:Yes 55 WZ3.odf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+50/-55 01/13/2022 Other:Wind Zone 3 Installation Instructions FL21705 R2 II PV MTSLDR 6134T XXXXXP WZ3 FBC 284x96 SS 2018-01-14.Ddf Verified By: Hermes Norero 73778 Created by Independent Third Party:Yes Evaluation Reports FL21705 R2 AE PER5392 SS 2018-02-08.Ddf Created by Independent Third Party:Yes 21705.2 Premium Vinyl(V-4500) Multi-Slide Patio Door 190.75'x 120"Insulated Glass(3/16" out Tempered-5/16"SGP Lam in)(XXXX) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL21705 R2 C CAC Imoact LC-PG50 DP-55 196x120 Approved for use outside HVHZ:Yes WZ3.Ddf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+50/-55 01/23/2022 Other:Wind Zone 3 Installation Instructions FL21705 R2 II PV MTSLDR 4P2T XXXXP WZ3 FBC 191x120 SS 2018-01-14.Ddf Verified By: Hermes Norero 73778 Created by Independent Third Party:Yes Evaluation Reports FL21705 R2 AE PER5391 SS 2018-02-08.odf Created by Independent Third Party:Yes 21705.3 Premium Vinyl(V-4500) Multi-Slide Patio Door 72"x 80"Insulated Glass_ (1/8"out Tempered-5/16"PVB Lam in)(OX) Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL21705 R2 C CAC OX R-PG50-72x80 WZ3.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 03/21/2021 Design Pressure:+50/-65 Installation Instructions Other:Wind Zone 3 FL21705 R2 II PV MTSLDR 2P2T OX WZ3 FBC 72x80 SS f, 2018-02-08.1)df Verified By: Hermes Norero 73778 Created by Independent Third Party:Yes Evaluation Reports FL21705 R2 AE PER5390.SS 2018-02-08.Ddf Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® FM Credit Card Safe a I https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqulXQ6Wb7.W... 12/4/2019 r� 398 E Dania Beach Blvd. . Q/ BUILDING DROPS Suite 338 A\\ Dania Beach; FL 33004 A Perfect Solution in Every Drop! 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report 1° Of JELD-WEN, inc. Premium Vinyl Multi-Slide Patio Door Impact Rated for Florida Product Approval Report No. 5392 Current Florida Building Code . Method: ' 1—A (Certificate Method) Category: Doors Sub—Category: Sliding Product: Premium Vinyl Multi-Slide Patio Door—PVB 6-Panel 2-Track XXXXXP Jamb Material: Vinyl Product Dimensions: 283 3/4"x 96" Prepared For: JELD-WEN, inc. 3737 Lakeport Blvd. Klamath Falls, OR 97601 � Prepared by: ``�` ��ES F. Hermes F. Norero, P.E. �-�•• •:�0 Florida Professional Engineer#73778 Date: 12/15/2017ir 0 Cp OP•'� 40: Contents: �i •......•••••G�=��• Evaluation Report Pages 1—3' ♦ S �ONA1-E``���� Digitally signed by Hennes F.Norero,P.E. Hermes�l!WW ��0, P.E. Reason:I am approving this document Florida No.73778 Date:2018.02.08 17:36:54-05'00' BUILDING DROPS A Perfect Solution in Every Drop! Date: 12/15/2017 Certificate of Authorization:29578 Report No: 5392 Manufacturer: JELD=WEN,inc. Product Category: Doors Product Sub-Category: Sliding Compliance'Method: State Product Approval Method (1)(a) Product Name: Premium Vinyl Multi-Slide Patio Door=PVB 6-Panel 2-Track XXXXXP Jamb Scope: This is a Product Eva luation.,Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN,inc. based on Method 1a of the State of Florida Product Approval, Florida Department of Business& Professional Regulation-Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This'product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions D014907,signed and sealed by Hermes F. Norero,P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the"High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be-as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not,require an impact resistant covering in Wind,Zones 3 or less.. 4. Site conditions that deviate from the details of drawing D014907 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions D014907 for,size and design pressure limitations. f Hermes F. Norero, P.E. Florida No..73778 Page 2 of 3 BUILDING DROPS /2017 A Perfect Solution in Every Drop! Date: 12/15 Report No: 5392392 Certificate of Authorization:29518 Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a program audited'by.and approved by American Architectures Manufactures Association (FBC Organization#: CER1773). Performance Standards: The product described herein has been tested per: • AAMA/WDMA/CSA/I.S.2/A440-08/11 • ASTM E1886-05 • ASTM E1996-09 Referenced Data: 1. Product Testing performed by National Testing Laboratories,Inc. (FBC Organization#TST1589) Report: NCTL-110-17-021, - Report Date:04/10/2017 2. Certification Agency American Architectures Manufactures Association (FBC Organization#CER1773) Installation: Refer to Installation Instructions(D014907)for anchor spacing and more details of the installation requirements. Design Pressure: Configuration Size Design Pressure XXXXXP 283 3/4"x 96" +50/-55 PSF Hermes F. Norero,P.E. Florida No. 73778 Page 3 of 3 _. - i .--------._---------------------------- - -I NAIL FIN INSTALLATION . 11/2"MIN.EMBEDMENT i! FIN i 2 2X WOOD FRAMEMOL 7M -------� colmm i MIN.DISTANCE MIN.DISTANCE FOR EDGE:3/4" FOR EDGE:3/4" 1/4"MAX 3 2X WOOD 3 13" y�,� � SHIM SPACE FRAME 22.0 mm 2 1/4"MAX 2.0 mm SHIM SPACE • ! 5.0 mm 3.0 mm i 11/2"MIN. }� EMBEDMENT GLASS BITE 13.0 mm /777 1 DOW 995 ----------- GLAZING DETAIL 1 FRAME SECTION(TYP) JAMB SECTION(TYP) VERTICAL SECTION NATE:rml4 b"t.riii N"IUng Flwg•6 Wood Opati.g. HORIZONTAL SECTION 1/4"MAX NOTE:Caulk betty NWUi q S.V.6 Wood Op ft - 02 SHIM SPACE 3 MIN.DISTANCE WWOW FOR EDGE:3/4" "�'"°`"MAX) 12 2X WOOD FRAME Max Frame I DP RATING IMPACT TYPICAL ELEVATION WITH FASTENER SPACING 1 _ C - -11/2"MIN.EMBEDMENT - 74.x 62 : +50/-50 YES Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1.- The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida 1/2"into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the'responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 5_mm annealed/9 mm airspace/3 mm annealed/2 mm PVB by project of installation. Dupont/3 mm annealed. Digitally signed by Hermes F.Norero,P,E. 4. Use structural or composite shims where required. Reason:I am approving this document 5. _ Installation methods can be interchanged withinthe sameopening. Date:2014.03.13 06:27:15-04'00' 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window_to achieve the rated design pressure up to the size limitationsOt I' 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does �% �� PROJECT ENGINEER: DATE: � ..•• •. i 3737 Lakeport Blvd not address the sealingconsideration that may arise in different wall 01/30/2014 y SCALE:�� \ •' �� M.RWEN Klamath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions �. : O DRAWN BY:D.Vezo NTS Phone: (541)882-3451 packaged with the window or go to 7 _�. .. CHECKED BY: TITLE: www.jeld-wen.com/resourcesfinstallaton. _ * = * = J. Kantola APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: „ This drawing and its contents are confidential and are not to be % -. < OP' �: PUTI�Pf�o i4 Nail Fin Installation(74 x 62 ) reproduced or copied in whole or in part or used or disclosed to others s®8�� 99 `` except as authorized by JELD-WEN Inc. 8 IDENTIFIER No: PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET NCTL210-3894- -FBC 1 of a rn y ` ----------- - --- -- - -- --- - ---- --- ------- -—---— -- THROUGH FRAME MIN.DISTANCE I INSTALLATION " FOR EDGE:3/4.3 l MAX.FRAME FMCORNM I 2 11/2"MIN. i EMBEDMENT 11/2"MIN. EMBEDMENT 1 114"MAX - 1/4"MAX 17.O.C. HIC. SHIM SPACE SHIM SPACE MWL THRU 3 _ FRW III�II y 2 � 5.0 mm 23,0 mm J 9 - MIN.DISTANCE 'Z FOR EDGE:3/4" ` GLASS BITE ---------- - = 13.0 mm x DOw 995 1 GLAZING DETAIL JAMB SECTION(TYP) HORIZONTAL SECTION FRAME SECTION(TYP) VERTICAL SECTION 1/4"MAX _4T TT t SHIM SPACE 3 TYPICAL ELEVATION�WITH FASTENER SPACING I 2 11/2"MIN. I Max Frame DP RATING IMPACT EMBEDMENT MIN.DISTANCE 74 x 62 +50/-50 YES- • I FOR EDGE:3/4" Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 11/2" of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The hast structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 5 mm annealed/9 mm airspace/3 mm annealed./2 mm PVB by project of installation. Dupont/3 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations �ij 7. Maximum sizes are buck sizes and do not include fin or flange1. . noted. It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE: ��� • • F ��� -- 02/03/2014 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall • ; •• 'pLEN Klamath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions = �- O D.Vezo DRAWN BY: scams. NTS Phone: (541)882-3451 packaged with the window or go to 7 _ .. CHECKED BY: TITLE: .. www.jeld-wen.com/resourcesfiinstallaton. _ ak * _ J. Kantola = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: ?� ; 4 1/ -- „ This drawing and its contents are confidential and are not to be �: p T PQo o• Through Frame Installation (74 x 62 ) reproduced or copied in whole-or in part or used or disclosed to others �� o. a �� AMEN-6 except as authorized b JELD-WEN Inc. sea L�f�t 83a IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET p Y n NCTL210-3894- -FBC 2OF4' MIN.DISTANCE i MASONRY INSTALLATION FOR EDGE:21/2" MASONRY 4' BLOCK 18.75'D.C. 3.1'MAX* MM FRAME FRORNM .2.MIN. A °e 3 CO = EMBEDMENT -41 11/4"MI ' EMBEDMENT 17,O.C. -MAX.THRU MAX FRAME SHIM SPACE MIN.DISTANCE I SPACE FOR EDGE:2 1/2' 22.0.m. 2.0= 5.0 3.0 2 GLASS BITE 13.0— MASONRY -4 I GLAZING DETAIL bow 995 BLOCK JAMB SECTION(TYP) HORIZONTAL SECTION FRAME SECTION(TYP) VERTICAL SECTION 1/4'MAX _4T T SHIM SPACE L WINDOW WIDTH(71'MAX) p 1MEMBEDMENT N. J -QENT TYPICAL ELEVATION WITH FASTENER SPACING Max Frame I DP RATING IMPACT ACT 4 5 MASONRY 74 x 62 +50/-50 1 YES BLOCK MINDNCE EE IL FOR EDGE: Ilr Installation Notes: General Notes: 1. ' Sea[flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use 3/16"Tapeon or equivalent fasteners through frame with sufficient length to penetrate a minimum of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida of 11/4"into concrete or masonry at each location with a 21/2"min from edge distance.For concrete Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. (min.Pc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM El 300. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing shall be 5 mm annealed/9 mm airspace/3 mm annealed/2 mm PVB by to the structure. The host structure is the responsibility of the architect or engineer of record for the Dupont/3 mm annealed. project of installation. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does 0PROJECT ENGINEER: DATE: not address the sealing consideration that may arise in different wall •• 01/30/2014 3737 Lakeport Blvd conditions. For the complete installation procedure,see the instructions 4 DRAWN BY: SCALE: JELDr�iVEN Klamath Falls,OR.97601 packaged with the window or go to 7 N D.Vezo NTS Phone: (541)882-3451 www.jeld-wen.com/resources/installation. CHECKED BY; TITLE: 1. Kantola -10T T CC APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider Z DISCLAIMER: -)3 44/ • This drawing and its contents are confidential and are not to be Masonry Installation (74"x 62") ,reproduced or copied in whole or in part or used or disclosed to others 0. a except as authorized by JELD-WEN Inc. 398 IF— 3319 IDENTIFIER No. PLANT NAME AND LOCATION: REV: SHEET NCTL210-3894-1-FBC 3 OF 4 MIN.DISTANCE STEEL INSTALLATION FOR EDGE:112" 1578'08 Be MALFRDM 2 Min.embedment �r-.----------------------------------------------i" 'FRAC C of three threads I I 3 pastframe 18 gauge min 18 gauge min . Steel Stud Steel Stud 1/4°MAX 17'O.Q t SHIM SPACE SHIM SPACE FRAME MIN.DISTANCE ,L �22.0 mm FOR EDGE.1/2" 2.0 mm 5.0 mm —.FH+3.0 mm Min.embedment tgt of three threads 3 6 GLASSBITE Pmt frame 13.0 mm ----------- .�` DOW 995. GLAZING DETAIL 1 JAMB SECTION(TYP) FRAME SECTION(TYP) HORIZONTAL SECTION VERTICAL SECTION 1-4 11/4'MAX T T T SHIM SPACE IB gauge min Steel Stud j "(DOW W=(7P MAX) I 3 TYPICAL ELEVATION WITH FASTENER SPACING 2 Min.embedment Max Frame DP RATING IMPACT of three threads p�tframe 74 x 62 +50/-50 1 YES F-�MIN.DISTANCE FOR EDGE:1/2" Installation Notes: General Notes: J 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. For anchoring into metal framing use#10 TEK Self Tapping screws with sufficient length to achieve a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum embedment of three threads past the frame thickness. Steel substrate min.18ga.,fy=33 ksi. Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 2 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads . All glazing shall conform to ASTM E1300. to the structure. The hosf structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 5 mm annealed/9 mm airspace/3 mm annealed/2 mm PVB by project of installation. Dupont/3 mm annealed. 4. Use structural or composite shims.where required. . 5. Installation methods-can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations 0%_ I (, -111. 7. Maximum sizes are buck sizes and do not include fin or flange. . noted. It is not intended as a guide to the installation process and does �� �� PROJECT ENGINEER: DATE: not address the sealing consideration that may arise in different wall ��� Q' ��� -' 01/30/2014 JEJD�fATEN 3737 Lakeport Blvd �/ 'f Klamath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions � ;' �,� : O D Veio-. SCALE: -NTS Phone: (541)882-3451 packaged with the window or go to 7 - — cHECI®BY: TITLE: www.jeld-wen.com/resourcesfinstallaton. _ * = * _ J. Kanto -10 T T = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: �3 141 -- This drawing and its contents are confidential and are not to be C OP':• �: PUTU6`JS�FG Steel Installation(74 x 62„) leproduced or copied in whole or in part or used or disclosed to others �� 0. 'F except as authorized b JELD-WEN Inc. 998 99e IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET p y NCTL210-3894- -FBC 4OF4 I 398 E Dania Beach Blvd. BUILDING DROPS Suite 338 Dania Beach, FL 33004 A Perfect Solution in Every Drop! 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of JELD-WEN, inc. Premium Vinyl Multi-Slide Patio Door Impact Rated for Florida Product Approval Report No. 5392 Current Florida Building Code Method: 1—A (Certificate Method) Category: Doors Sub—Category: Sliding Product: Premium Vinyl Multi-Slide Patio Door—PVB 6-Panel 2-Track XXXXXP Jamb Material: Vinyl Product Dimensions: 283 3/4"x 96" Prepared For: JELD-WEN, inc, 3737 Lakeport Blvd. Klamath Falls, OR 97601 Prepared by: `��`SES F. Hermes F. Norero, P.E. -. 0 Florida Professional Engineer#73778 = Date: 12/15/2017 -o,10 T T Contents: 'i T ••......••••• G�=��� Evaluation Report Pages 1—3 \ ♦ S S�0NAI-1F %%%� Digitally signed by Hermes F.Norero,P.E. Hermeso,P.E. Reason:I am approving this document Florida No.73778 Date:2018.02.08 17:36:54-05'00'- BUILDING DROPS Date: 12/15/2017 • A Perfect Solution in Every Drop! Report No: 5392 Certificate of Authorization:29578 Manufacturer: JELD-WEN,inc. Product Category: Doors Product Sub-Category: Sliding Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Vinyl Multi-Slide Patio Door—PVB 6-Panel 2-Track XXXXXP Jamb Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WENjnc. based on Method 1a of the State of Florida Product Approval, Florida Department of Business& Professional Regulation-Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions D014907,signed and sealed by Hermes F. Norero, P.E. (FL#73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, excluding the"High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering in Wind Zones 3 or less. 4. Site conditions that deviate from the'details of drawing D014907 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions D014907 for size and design pressure limitations. Hermes F. Norero,P.E. Florida No.73778 Page 2 of 3 BUILDING DROPS /2017 A Perfect Solution in Every Drop! Date: 12/15 Certificate of Authorization:29578 Report No: 5339292 Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under'a program audited by and approved by American Architectures Manufactures Association (FBC Organization#: CER1773). Performance Standards: The product described herein has been tested per: • AAMA/WDMA/CSA/I.S.2/A440-08/11 • ASTM E1886-05 • ASTM E1996-09 Referenced Data: 1. Product Testingperformed by National Testing Laboratories,Inc. (FBC Organization#TST1589) Report: NCTL-110-17-021, Report Date:04/10/2017 2. Certification Agency American Architectures Manufactures Association (FBC Organization#CER1773) Installation: Refer to Installation Instructions(D014907)for anchor spacing and more details of the installation requirements. Design Pressure: Configuration Size Design Pressure XXXXXP 283 3/4 x 96" +50/-55 PSF Hermes F. Norero, P.E. Florida No.73778 Page 3 of 3