HomeMy WebLinkAboutProduct Approval (3) FLORIDA DOPARVA(INT OF
Business & Professional Regulation
BCIB.Home Log In I User RegistrationHot Toplis Submit Sprcharge Staffs®Facts Publications I Fec Staff Bas Site Map Unks Search i
Fl rida '
Product Approval'
USeR:Public User -
: .:• RECEIVED
..�Product'Aaoroval'Mena>.Pmduct or�A'oolloa4lun'$earctY>'Aoolleatlan Llsf 'pppllraflon D'etall +'
DEC 09-2019
. . Application Type Revision
Code Version .. 2017 ; • ST. Lucie County,, Permitting
Application Status " . Approved
*Approved by DBPR:Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Arctifved ❑
Product Manufacturer IKO Industries,Ltdt- L E COPY
Address/Phone/Email 40 Hansen Road Sou RE
Brampton,NON-US L6W 3H4
(70B)496-2800 Ext 200
rmetzOO1@tampabay.rr.com
Authorized Signature Robert Metz
rmetzOC1@tampabay.rr.com
Technical Representative Bob Metz
Address/Phone/Emall REMCO of Pinellas
456 Avila Circle NE "
Saint Petersburg,FL 33703
(727)776-5261
rmetzOO1@tampabay.rr.com
Quality Assurance Representative Don Shaw
Address/Phone/Emall IKO Industries LTD
120 Hay Rd.
Wilmington,DE 19808
(717)579-6706
don.shaw@iko.coin
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency FM Approvals-CER
Validated By Locke Bowden
O Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 modified to 110 mph 2016
ASTM D3462 2010
ASTM D7158 Class H 2011
ASTM E108 2011 .
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 10/08/2017
Date Validated 10/30/2017
Date Pending FBC Approval
Date Approved 11/01/2017
Summary of Products
FL# Model,Number or Name Description
7006.1 Cambridge,Cambridge HD, Laminated architectural fiberglass asphalt shingle
Biltmore and Biltmore HD manufactured at IKO's Kankakee,IL;Hawkesbury,Ont.;
Wilmington,DE;Sylacauga,AL and Toronto,Ont,plants
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL7006 RIO C CAC Letter-ASTM D3161 letter-(9-26-
Approved for use outside HVHZ:Yes 2017)from FM.odf
Impact Resistant:N/A FL7006 RIO C CAC Letter-ASTM D3462 letter-(9-26-
Design Pressure:N/A 2017).odf
Other: FL7006 RIO C CAC Letter-ASTM E108 letter-(9-26-
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 RIO II IKO-187-02-01 Letter-Installation
Instructions for FBC FL7006.Ddf
Verified By: Duc T Nguyen 65034
Created by Independent Third Party:No
Evaluation Reports
Created by Independent Third Party:
7006.2 Hip and Ridge 12 Cap This Is a 12"x 12"fiberglass asphalt shingle used to cover
the hip and/or ridge of an asphalt shingle roof system
manufactured at IKO's Kankakee,IL,Toronto,Ont.and
Brampton,Ontario plants.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL7006 RIO C CAC ASTM D 3462-Shingle letter
Approved for use outside HVHZ:Yes Surveillance Audit Location-(6-28-20171.pdf
Impact Resistant:N/A FL7006 R10 C CAC Letter-ASTM D3161 letter-(9-26-
Design Pressure:N/A 2017)from FM.odf
Other: FL7006 RIO C CAC Letter-ASTM D3462letter-(9-26-
2 17).nd
FL7006 RIO C CAC Letter-ASTM E108 letter-(9-26-
20171.Ddf
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 RIO II HID and Ridge Cao Shingle Installation
Instructions.odf
FL7006 RIO II TKO-187-02-01 Letter-Installation
Instructions for FBC FL7006.Ddf
Verified By:Duc T Nguyen PE 65034
Created by Independent Third Party: No
Evaluation Reports
Created by Independent Third Party:
7005.3 Leading Edge Plus Asphalt Shingle One piece fiberglass asphalt shingle used as a starter strip at
Starter Strip the bottom of a roof system manufactured in Brampton and
Hawkesbury,Ontario plants
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL7006 RIO C CAC Letter-ASTM D3161 letter-(9-26-
Approved for use outside HVHZ:Yes 20171 from FM.odf
Impact Resistant:N/A FL7006 RIO C CAC Letter-ASTM D3462 letter-(9-26-
Design Pressure:N/A 20171.odf
Other: FL7006 RIO C CAC Letter-ASTM E108 letter-(9-26-
2 17). df
Quality Assurance Contract Expiration Date
12/31/2020
Installation Instructions
FL7006 RI0 II IKO-187-02-01 Letter-Installation
Instructions for FBC FL7006.odf
FL7006 RIO II Roofing-Products-Leading-Edae-Plus-
ADDlication-EN(1).Ddf
Verified By: Duc T Nguyen PE 65034
Created by Independent Third Party:No
Evaluation Reports
Created by Independent Third Party:
7006.4 Marathon Plus AR,Superglass Plus 3 tab fiberglass asphalt shingle manufactured at IKO's
AR Brampton,Ontario,Hawkesbury Ont.,Toronto,Ont.;
Sylacauga,AL and Kanakakee,IL plants
Limits of Use Certification Agency Certificate
Approved for use In HVHZ:Yes FL7006 R10 C CAC Letter-ASTM D3161 letter-(9-26-
Approved for use outside HVHZ:Yes 2017)from FM.Ddf
Impact Resistant:N/A FL7006 R10 C CAC Letter-ASTM D3462 letter-(9-26-
Design Pressure:N/A 2017).Ddf
Other: FL7006 R10 C CAC Letter-ASTM E108 letter-(9-26-
2017),Ddf
Quality Assurance Contract Expiration Date
12/20/2020
Installation Instructions
FL7006 R10 II IKO-187-02-01 Letter-Installation
Instructions for FBC FL7006.pd
Verified By; Duc T Nguyen 65034
Created by Independent Third Party:No
Evaluation Reports
Created by Independent Third Party:
Beck Nert
contact us;;2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-4B7-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are pubic records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-pursuant to Section 455.275
(1),nodda Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please
click her..
Product Approval Auxptn:
®®®99
Credit Card
Safe
CONSTRUCTION MATERIALS
TECHNOLOGIES
October 27,2017
IKO Industries, Ltd
120 Hay Rd.
Wilmington, DE 19809
Re: FBC FL7006
Sir(s),
PRI Construction Materials Technologies has completed a technical review and attached sealed shingle
instructions in compliance the 2017 Florida Building Code.
This review was completed based on the receipt of following evidence from IKO Industries, Ltd:
1) IKO Shingle Application Instructions—3-Tab Shingles
(EN-3Tab Appins 8AGXEFS-2012-11 reformatted 2013-02-rev07/13-Florida)
2) IKO Laminated Shingles Application Instructions
(EN-Laminated Appins-8TTEFS-2012-04—reformatted 2013-02-rev07/13-Florida)
3) IKO Hip and Ridge 12 Application Instructions
(EN-HipandRidge12 3HRTri-2013-08—reformatted 2013-08)
4) IKO Leading Edge Plus Shingle Application Instructions
(EN-3LEP-Tri-2012-06—reformatted 2013-03)
5) ASTM D3161 Test Report(FM Approvals Project No. 3040947)
The attached instructions should be used in conjunction with the published manufacturer's application
instructions and applicable code. In the event the instructions conflict,these instructions shall govern.
Statement of Independence:PRI Construction Materials Technologies and/or Duc T.Nguyen,FL P.E.do not
have nor plan to acquire a financial interest in any company manufacturing or distributing products for which
the test reports are issued.
Signed: C Signed:
Brad Griyrb ski Duc T. u en
Managing Dfrector Florida R Bred Professional Englneer
P.E.Number.65034
Date: October 27,2017 Date: October 27,2017
Attachments: A)IKO Shingle Application Instructions-3-Tab
B) IKO Laminated Shingles Application Instructions
C) IKO Hip and Ridge 12 Application Instructions
D) IKO Leading Edge Plus Application Instructions
IKO-1 87-02-01
PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813.621-5M Fax:813621-5840 e-mail:matedalstesting@p(mmtoom website:http1Avww.pdcmtcom
i
IKO
Installation Instructions for
Asphalt Shingles
Page 2 of 5
IKO Shingle Application Instructions — 3-Tab Shingles
(ASTM D3161, Class F IKO Marathon 26 AR and CRC Superglass M26AR)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC.
UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements,the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping
each preceding course by 19"or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4" per foot or greater, cover the deck wi#h one ply of
underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING:Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long
enough to penetrate through plywood or3/4"into boards. Use 4 nails per shingle placed 6-1/8"above the butt
edge,approx. 1"and 13"from each end and 1/2"above each cutout. Drive nails straight so that nail head is
flush with, but not cutting into shingle surface.
NAILING ON STEEP SLOPES:For steep slopes of 21"per foot(60°)or more,use 6 nails per shingle placed
as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt
plastic cement placed under the shingle 2 above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight.
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-5/8".
STEEP SLOPES
jNAILS
—j—-_ SEALING SSRIP
6.118'
11 I I NAILS
DO NOT NAIL INTO ORABOVE THE SEALING STRIP
PRI Construction Materials Technologies,U.C.6412 Badger Drive Tampa,FL 33610 Tel:813821-5777 Fax:813.6215840 e-mail:materialstesting@pricmtcom Website:hIIpJ/www.pdcmtcom
IKO
Installation Instructions for
Asphalt Shingles
Page 3 of 5
IKO Laminated Shingles Application Instructions
(ASTM D3161, Class F—Cambridge, Cambridge HD, and CRC Biltmore AR)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: Solidly sheathed and fastened deck conforming to 2017 FBC.
UNDERLAYMENT:Applied in accordance with building code requirements.For areas where the roof slope is
less than 4" per foot down to 2" per foot, use 2 layers of underlayment conforming.to building code
requirements,the first sheet overlapping the eave protection by 19",followed by full 36"widths overlapping
each preceding course by 19"or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING:Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long
enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed in the nail line 7-3/8"
below the top edge,approx. 1"and 13"in from each end. Drive nails straight so that nail head is flush with,
but not cutting into shingle.surface.
NAILING ON STEEP SLOPES:For steep slopes of 21"perfoot(60°)or more,use 6 nails per shingle placed
as shown below. Ensure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)'spots of asphalt
plastic cement placed under the shingle 2"above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight.
EXPOSURE: Installed shingles shall have a maximum average exposure of 5-718".
NAILING-STEEP SLOPES APPLICATION
Use sur nails as shown.
7 318'
�— NAIL LINE
6 318 4Lnm n- Fa FT. F1t
NAILS CEMENT
PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OF THE SHINGLE
PRI Coristrudon MatedalsTechnoiogies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:813.621-5777 Fax:813-621-5840 e-mail mateflalstesbg@pdrmtcom WebSite:httpJ1w=pdcmt.com
IKO ,
Installation Instructions for
Asphalt Shingles
Page 4 of 5
IKO Hip and Ridge 12 Application Instructions
(ASTM D3161, Class F—IKO Hip and Ridge 12)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
Cut hip and ridge shingles into thirds, using the perforation marks as a cutting guide. These shingles are
designed for a 51/8"(130 mm)exposure.(For a neater appearance,the top of each side of each piece has
been factory trimmed on a 1"(25 mm)taper(see drawing).Bend each piece over the hip or ridge,and nail 5
5/8" (143 mm)above the butt edge 1" (25 mm) in from each edge, exposing each piece 51/8"(130 mm).
Apply hip pieces starting at the lower end of the hip,working up toward the ridge. On hip roofs,apply ridge
pieces starting at each end', meeting in the middle. On gable roofs, apply ridge pieces starting at the end
opposite to the prevailing wind direction and continue to the other end.Note:To obtain a three-dimensional
effect,(which is recommended,but not required),apply hip and ridge shingles double thickness bystacking 2
pieces on top of one another,the lower piece extending about 3/4"(19 mm)further than the top piece(see
diagram).The final shingle should be set in cement,and the exposed nail heads of the final shingle should be
covered with cement. Prior to application in cold weather, storing the shingles in a heated area will allow for
easier bending.
NOTE:SHINGLES MUST BE APPLIED PROPERLY.THEY ARE DESIGNED FOR USE AS HIP AND RIDGE
SHINGLES ONLY;AND SHOULD NOT BE USED FOR ANY OTHER APPLICATIONS.WE ASSUME NO
RESPONSIBILITY FOR LEAKS OR DEFECTS RESULTING FROM POORAPPLICATION OR FAILURE TO
PROPERLY PREPARE THE SURFACE TO BE ROOFED OVER,OR FAILURE TO PROVIDE PROPER
VENTILATION IN ACCORDANCE WITH MINIMUM PROPERTY STANDARDS REQUIREMENTS.REVIEW
ALLAPPLICABLE BUILDING CODES,MINIMUM PROPERTY STANDARDS,AND REQUIREMENTS PRIOR
TO APPLYING THESE SHINGLES USING THESE APPLICATION INSTRUCTIONS.
ram
psumm) TAPER cvr. .
stta
p30 two
6Sfl'
dexmml
PRI Construction Materials Technologies,LLC.6412 Badger Drive Tampa,FL 33610 Tel:81&621-5777 F=813-621-5840 a-mail:matedalstesting@pticmtcom Website:hflp:IMiww.pricmtcom
lK0
installation Instructions for
Asphalt Shingles
Page 5 of 5
IKO Leading Edge Plus Application Instructions
(ASTM 133161, Class F—IKO Leading Edge Plus)
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
1. Apply any underlayment,eave protection,valley flashings,or drip edges to roof deck as required.
2. Each 39 3/8"x 131/4"(1000 mm x 336 mm)IKO Leading Edge Plus strip is perforated lengthwise for
separation into two(2)shingles.Take one IKO Leading Edge Plus strip and fold flat at perforation to
separate.
3. Take one of the separated shingles 39 3/8"x 6 5/8"(1000 mm x 168 mm)and remove approximately
20"(500 mm). Install this shingle on the lower left comer of the roof deck, granule side up,with the
factory installed sealant adjacent to the eaves.The shingle should overhang the rake edge and eaves
by a nominal 1/4"(6 mm)minimum.Fasten the shingle to the roof deck with nails located 3"to 4"(75
mm to 100 mm)from the eave edge and 1"(25 mm) in from each end.
4. Take the leftover 20"(500 mm)piece shingle.Rotate the piece and align it vertically up the rake edge
with the factory installed sealant adjacent to the outer edge of the roof.The shingle should overhang
the rake edge by a nominal 1/4!'(6 mm)minimum.Fasten the shingle to the roof deck with fasteners
located 3"to 4"(75 mm to 100 mm)from the rake edge and 1"(25 mm)in from each end.
5. Repeat Steps 3—4 for the right lower corner of the roof deck.
NAILING: Use galvanized(zinc coated) roofing nails, 11 or 12 gauge,with at least
3/8"(9 mm)diameter heads, long enough to penetrate through plywood or 3/4"(20
mm) into boards. Use 4 nails per shingle placed 3"to 4"(75 mm to 100 mm)from
the eave edge and approximately 1"and 13"(25 mm and 330 mm)in from each end.
6. Apply full-length IKO Leading Edge Plus shingles to the remaining eave edges of the roof deck.Install
the shingles granule side up with the factory applied sealant adjacent to the eaves. The shingles
should overhang the rake edge and eaves by a nominal 1/4"(6 mm)minimum.Fasten the shingles to
the roof deck with nails located 3"to 4"(75 mm to 100 mm)from the eave edge,4 nails per shingle.
7. Apply roof shingles as per the instructions printed on each product's package.Make certain the first
course of field shingle lies flush with the edges of the fastened IKO Leading Edge Plus. In this way,
the sealant on the IKO Leading Edge Plus shingles will adhere to the first-course field shingles and
help keep them from lifting in high winds.
PRI ConsWclion Mater'ralsTechnologies,LLC.6412 BadgerDrke Tampa,FL33610 Tel:813.621-5717 Fax:813-621W a-maii:rn&rialstes8ng@pdcmtcom WebSite:hftpJMovw.pricmtcom