Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
Miami-Dade County Building Product Information for N.O.A. 17-0614.09 i NOA 17-0614.09 tt-(library�roductcontrol/noa/17061409.p�_ Superseded—By File Status File Approved File Classification High velocity hurricane zone Category Windows Subcategory Fixed Material Vinyl- PVC Applicant PGT Industries, Inc. pc-result detail app.asp?app__alias=101544 J. Expiration—Date April/30/2020 Impact—Rate Large and Small Missile Impact Maximum_Design_Pressure_Positive 80 Maximum_Design_Pressure_Negative 110 Description Series TW-5520 Vinyl" PVC Fixed Window- L.M.I. Green—Sustainable—Attributes NONE For a detailed description on the File Status, click the NOA File Status Key_(/building/pc-result key app.asp� Page Last Edited:Wed Jan 25,2017 10:40:27 AM MtAWL1AlQE a Miami-Dade County Building Product Information for N.O.A. 17-0420.06 NOA 17-0420.06L(tibrary�roductcontrol/noa/17042006.p�_ Superseded_By File Status File Approved File Classification High velocity hurricane zone Category Doors Subcategory Sliding Material Vinyl-PVC Applicant PGT Industries, Inc. pc-result detail app.asp?app alias=101544) Expiration—Date April/14/2021 Impact Rate Large and Small Missile Impact Maximum—Design—Pressure—Positive 100 Maximum_Design_Pressure_Negative 100 Description Series"5570/2770 Vinyl'White Rigid PVCI Sliding Glass Door w/Reinforcements- LMI Green—Sustainable—Attributes NONE For a detailed description on the File Status, click the NOA File Status Key_(/building/pc-result keX app.asp). Page Last Edited:Wed Jan 25,2017 10:40:27 AM MIAMMAIM Last Modified Date:09/23/2019 13-14.14 PO#: Job Name:IAMBERT 2019 Job Address: Quote# 5887438 Ship Date: customer copy detailed Sales Person-:Jon Young Customer Jeffery J Pauly Construction Inc Account# 2420 SW Maplewood Dr Palm City,FL 34990 Phone#(772)263-8268 Fax# Line# Item Description Quantity Line Pricing 0000 CRYSTAL CARE ELITE WARRANTY Ordered: List Price Sell Price Ext Price (850.01) 11.00 _ $556.26 $556.26 $556.26 )Configuration:CRYSTAL CARE ELITE WARRANTY Locations Notes 70 Rfrm 7`71 P 0001 SGD5570 VINYL SGD SERIES 5570 Ordered. List Price Sell Price Ext Price (1.00) � 1.00 $6,261.39 $5,466.20 $5,466.20 Configuration:104.5X79.5,BYPASS,2P2T,XX,STD,2.5,B/W,1 1/16 TLIG,CLEAR,ARG,ES Max,NO GRID,ALL Send Unit:COMPLETE Certification Type:MIAMI i NOA Selection:17-0420.06 Dealer Package:ECRYSTALCARE Door Configuration:BYPASS PnI/Trk:2 Panel/2 Track Panel Configuration:XX Panel Stack:STD Size Selection:CUSTOM Width:104.5000 Height:79.5000 Actual Size:1041/2 X 79 1/2 Calc Track Length:104.5000 Frame Color:B/W -Bronze Exterior/White Glass Makeup:LIT307SS7S Glass:1-1/16"LIG(3/16 TMP-7/16ARG-7/16 HS/HS Glass Family:LI -Laminated Insulating Does unit need to meet Turtle Code:NO Glass Color:CL -CLEAR Low E:ENERGY SHIELD MAX Argon Gas:ARGON Privacy Glass:NONE -NONE Interlayer Type:SGPO90 Grid Type:NONE -NO Grid Sill Riser Height:2.5000 Screen Panel Type:NONE Send Screen Frame with Unit:N Handle Type:RAISED/RAISED Handle Color:SNKPVD -Satin Nickel PVD Lock/Handle Location:STD Secondary Lock Type:NONE Key Lock:N Keyed Alike:N Panel Opr Rlr:STSTEELTM Stainless Steel Tandem Anchor Group:A.SGD5570 Send frm w/snap on Nail Fin:N Boxing Options:N -None Max Energy/Composite Reinf:N CAR#:17-0420.06 Positive Desig nPressure:38.7000 NegativeDesignPressure:80.0000 PANumber:FL-251 EnergyStar:NONE Condensation Resistance:58.0000 UF:0.3100 SolarHeatGainCoeff:0.1900 VT:0.4200 VTCOG:0.6100......................................................_.........................................._......__............................. ----..........................................._..._._._._-._.._............._..._._......................................................._............_.........._.......................................................__......_.. Quote# 5887438 Print Date 9/30/2019 Page 1 of 3 __._.._............._...- ---._._._.._.........................---.........._....._._................................._._....__..._.._._.._.._.........................._......................---- --._...__.. ---------------------- _._. Location: Notes: _ 6 %,' -..�a t a �'a, y�""rx"s� e`` '�"` s °R"AF .:°W ;3 a,...x.„ti<„w� _ 0002 PW5520 PW5520 VINYL PICTURE WINDOW Ordered: List Price Sell Price Ext Price (2.00) 2.00 $641.62 $442.72 $885.44 !Configuration:22.75X46.75,5/8"FL,B/W,7/8 LIG,CL,ARG,OUTSIDE GLZ,NO GRID Certification Type:MIAMI NOA Selection:17-0614.09 _... Dealer Package:ECRYSTALCARE Frame Type:.625FLANGE Size Selection:CUSTOM Size Ref:ACTUAL Width:22.7500 Height:46.7500 Actual Size:22 3/4 X 46 3/4 Rough Masonry Opening:24 1/2 X 47 3/4 Wood Frame Opening:23 X 47 Frame Color:B/W -Bronze Exterior/White Glass Family:LI -Laminated Insulating Interlayer Type:PVB090 Glass Makeup:LIA207AA5 Glass:7/8"LIG(1/8 AN-7/16 ARG 5/16 AN/AN Does unit need to meet Turtle Code:NO Glass Color.CL -CLEAR Low E:NONE Argon Gas:ARGON Privacy Glass:NONE-NONE Grid Type:NONE -NO Grid Boxing Options:N -None CAR#:17-0614.09 PositiveDesignPressure:50.0000 NegativeDesignPressure:50.0000 PANumber:FL243 EnergyStar:NONE 73 3ti . Condensation Resistance:47.0000 UF:0.4100 SolarHeatGainCoeff:0.6000 VT:0.6700 VTCOG:0.8000 Location: Notes: xn a r` j F, _ a 0003 PW5520 PW5520 VINYL PICTURE WINDOW Ordered: List Price Sell Price Ext Price (3.00) 12.00 1 $1,443.62 1 $996.10 1 $1,992.20 Configuration:58.75X46.75,5/8"FL,B/W,CL,ARG,OUTSIDE GLZ,NO GRID Certification Type:MIAMI NOA Selection:17-0614.09 _ Dealer Package:ECRYSTALCARE Frame Type:.625FLANGE Size Selection:CUSTOM Size Ref:ACTUAL Width:58.7500 Height:46.7500 Actual Size:58 3/4 X 46 3/4 Rough Masonry Opening:60 1/2 X 47 3/4 Wood Frame Opening:59 X 47 Frame Color:B/W -Bronze Exterior/White Glass Family:LI -Laminated Insulating Interlayer Type:PVB090 El Glass Makeup:LIA306AA7 Glass:1"LIG(3/16 AN-3/8 ARG-7/16 AN/AN PVB) Does unit need to meet Turtle Code:NO Glass Color:CL -CLEAR Low E:NONE Argon Gas:ARGON Privacy Glass:NONE-NONE Grid Type:NONE -NO Grid Boxing Options:N -None CAR#:17-0614.09 PositiveDesignPressure:70.0000 NegativeDesignPressure:70.0000 PANumber:FL243 EnergyStar:NONE CondensationResistance:46.0000 UF:0.4200 SolarHeatGainCoeff:0.5700 VT:0.6500 VTCOG:0.7800 Location N otes o _. Products Ordered Total Quantity 1 SGD5570 1 PW5520 4 TOTAL LIST AMOUNT: $10988.13 TOTAL SALE AMT: $9,178.23: TOTAL CUSTOMER $550.69: TAX: $9,728.92: Quote# 5887438 Print Date 9/30/2019 Page 2 of 3 M IAM I-RADE MIAMI-DADS COUNTY a PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy PGT Industries,Inc. 1070 Technology Drive North Venice,FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). ThisNOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(m areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted manner; the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone. DESCRIPTION: Series"PW-5520 Vinyl"PVC Fixed Window—L.M.I. APPROVAL DOCUMENT: Drawing No. MD-5520.0 titled "Vinyl Fixed Window NOA (LM&SM)", sheets 1 through 11 of 11, dated 09/09/14, with revision B dated 06/06/17,prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "IvEami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#16-0629.12 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No. 17-0614.09 MIAMFDALIE COUNTY Expiration Date: April 30,2020 Approval Date: October 26,2017 10,17/17 Page 1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NDA No. 14-0930.25) 2. Drawing No. MD-5520.0 titled"Vinyl Fixed Window NOA(LM&SM)", sheets 1 through I 1 of 11, dated 09/09/14, with revision B dated 06/06/17,prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1)Uniform. Static Air Pressure Test, Loading per FBC, TAS 202-94 2)Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a PVC sliding glass door, a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS spacer system, Duraseal-' spacer system, Super Spacer®NXTTM spacer system and XL EdgeTM spacer system at insulated glass,prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-8717, FTL-8968 and FTL-8970, dated 11/16/15, 06/07/16 and 06/02/16 respectively, all signed and sealed by Idalmis Ortega,P.E. (Submitted under previous NOA No. 16-0629.12) 2. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1, and TAS 202-94 along with marked-up drawings and installation diagram of a PVC fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-7897, dated 08/01/14,signed and sealed by Idalmis Ortega,P.E. (Submitted under NOA No. 14-093 0.25) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-51h Edition (2014), dated 09/18/14 and 04/07/15,prepared by manufacturer,signed and sealed by Anthony Lynn Miller,P.E. (Submitted under NOA No. .14-0930.25) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). Manuel P ez, .E. Product Controlt iner NOA No. 1 4.09 Expiration Date: April 30,2020 Approval Date: October 26,2017 E-1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America,Inc. for their "Trosifol®Ultraclear, Clear and Color PVB Glass Interlayers"dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America,Inc. for their "SentryGlas®(Clear and White) Glass Interlayers"dated 06/25/15, expiring on 07/04/18. 3. Notice of Acceptance No. 16-0712.03 issued to ENERGI Fenestration Solutions USA for their"White Rigid PVC Exterior Extrusions for Windows and Doors" dated 08/10/17, expiring on 02/28/18. 4. Notice of Acceptance No. 16-0712.04 issued to ENERGI Fenestration Solutions USA, Inc. for their"Bronze and Lighter Shades of Cap Coated White Rigid PVC Exterior Extrusions for Windows and Doors"dated 09/15/16, expiring on 04/16/20. 5. Notice of Acceptance No. 16-0712.05 issued to ENERGI Fenestration Solutions USA, Inc. for their"Performance Core Rigid PVC Exterior Extrusions for Windows and Doors" dated 09/15/16, expiring on 04/16/20. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 51h Edition(2014) and FBC 6th Edition (2017), dated August 29, 2017, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated June 9, 2017,issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal issued by Product Control, dated 6/26/14, signed by Jaime Gascon, P.E. Supervisor,Product Control Section. (Submitted under NOA No. 14-0930.25) 4. Proposal No. 16-0125 issued by the Product Control Section, dated March 09, 2016, signed by Ishaq Chanda, P.E. (Submitted under previous NDA No. 16-0629.12) G. OTHERS 1. Notice of Acceptance No. 16-0629.12, issued to PGT Industries,Inc. for their Series "PW-5520 Vinyl"PVC Fixed Window—L.M.I. approved on 08/04/16 and expiring on 04/30/20. Manuel a ez,P.E. Product Contr4maminer NOA No. 7-0614.09 Expiration Date: April 30,2020 Approval Date: October 26,2017 E-2 M IAM IDDADE MIAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) mvw.miamidade.goy/economy PGT Industries,Inc. 1070 Technology Drive, North Venice,FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for.quality assurance purposes: If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series"5570/2770"Vinyl Sliding Glass Door(Reinforced)-L.M.I. APPROVAL DOCUMENT: Drawing No. MD-5570.0,titled"Vinyl Sliding Glass Door NOA(LM)", sheets 1 through 21 of 21,prepared by manufacturer,dated 10/05/15, with revision A dated 04/05/17,signed and sealed by A. Lynn Miller,P.E., bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami-Dade County Product Control Approved",noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#15-•1210.01 and consists of this page 1 and evidence pages E-1,E-2,E-3 &E-4 as well as approval document mentioned above. The submitted documentation was reviewed by Jorge M.Plasencia,P.E. NOA No. 17-0420.06 MfAMt•DADt:COUNTY ( , ;` f!/ r j Expiration Date: April 14,2021 8 f l Approval Date: September 28,2017 Page 1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitter)under NOA No. 11-0107.04) 2. Drawing No. MD-5570.0,titled"Vinyl Sliding Glass Door NOA(LM)", sheets 1 through 21 of 21,prepared by manufacturer, dated 10/05/15, with revision A dated 04/05/17, signed and sealed by A. Lynn Miller,P.E. B. TESTS 1. Test report on 1)Uniform Static Air Pressure Test,per FBC,TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc., Test Report No. FTL 8717, dated 12/07/15, signed and sealed by Idalmis Ortega,P. E. (Test report revised on 02/15/16 and 02/24/16) 2. Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,per FBC,TAS 202-94 3)Water Resistance Test,per FBC, TAS 202-94. 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test, per FBC,TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab, Inc., Test Report No. FTL 8546, dated 11/06/15, signed and sealed by Idalmis Ortega,P. E. (Test report revised on 01/04/16 and 02/11/2016) 3. Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2) Uniform Static Air Pressure Test,per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test, per FBC,TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc.,Test Report No.-FTL 8547, dated 12/04/15, signed and sealed by Idalmis Ortega,P.E. (Test report revised on 02/15/16) 4. Test report on 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test, per FBC,TAS 202-94 3) Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC, TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab, Inc.,Test Report No. FTL 8548, dated 12/04/15, signed and sealed by Idalmis Ortega,P. E. (Test report revised on 01/04/16 and 02/11/16) ,r orge M.Plasencia,P.E. Product Control Unit Supervisor NOA No.17-0420.06 Expiration Date: April 14,2021 Approval Date: September 28,2017 E-1 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (continued) 5. Test report on 1) Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test,per FBC,TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94. 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test,per FBC, TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab, Inc., Test Report No. FTL 8549, dated 11/06/15, signed and sealed by Idalmis Ortega,P. E. (Test report revised on 12/04/15 and 02/11/16) 6. Test report on 1) Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test, per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94. 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab, Inc., Test Report No. FTL 8552, dated 12/04/15, signed and sealed by Idalmis Ortega,P. E. (Test report revised on 02/15/2016) 7. Test report on 1)Uniform Static Air Pressure Test,per FBC,TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc., Test Report No. FTL 6638 (samples A-1 thru A-22), dated 11/19/10, signed and sealed by Jorge A. Causo,P. E. (Submitted raider NOA No. 11-0107.04) 8 Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94. 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC, TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc.,Test Report No. FTL 6337(samples A-1 thru A-5), dated 12/06/10, signed and sealed by Jorge A. Causo, P. E. (Submitted under NOA No. 11-0107.09) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-2014,prepared by PGT, dated 12/09/15and last revised on 02/15/16, signed and sealed by Anthony L. Miller, P.E. y (Submitted under NOA No. 15-1210.01) Jorge M.Plasencia,P.E. Prod6t Control Unit Supervisor NOA No. 17-0420.06 Expiration Date: April 14,2021 Approval Date: September 28,2017 E-2 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS (cont.) 2. Glazing complies with ASTME-1300-09 D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 15-0528.14 issued to Vision Extrusion Limited for their"White Rigid PVC Exterior Extrusions for Windows and Doors", dated 08/13/15, expiring on 09/30/19. 2. Notice of Acceptance No. 16-0920.08 issued to Vision Extrusion Limited for their"VE 1000 Tan 202 and lighter Shades (Non-White)Rigid PVC Exterior Extrusions for Windows and Doors",dated 12/08/16, expiring on 12/29/21. 3. Notice of Acceptance No. 15-0528.15 issued to Vision Extrusion Limited for their"Brown Coated(Painted or Laminated)White Rigid PVC Exterior Extrusions for Windows and Doors",dated 08/13/15, expiring on 09/30/19. 4. Notice of Acceptance No. 16-0712.02 issued to ENERGI Fenestration Solutions USA, Inc. for their"TAN 3040 and Lighter Shades (Non-White)Rigid PVC Exterior Extrusions for Windows and Doors"dated 09/15/16, expiring on 02/04/21. 5. Notice of Acceptance No. 16-0712.04 issued to ENERGI Fenestration Solutions USA,Inc. for their"Bronze and Lighter Shades of Cap Coated Rigid PVC Exterior Extrusions for Windows and Doors"dated 09/15/16, expiring on 04/16/20. 6. Notice of Acceptance No. 16-0712.03 issued to ENERGI Fenestration Solutions USA, Inc. for their"White Rigid PVC Exterior Extrusions for Windows and Doors"dated 08/10/17, expiring on 02/28/18. 7. Test reports No(s). 10-002-792(A), 10-06-M0527, 535753-09,per ASTME-84,ASTMD1929 and ASTMD-635, issued by EXOVA to Vision Extrusion for cellulosic composite material. (Submitted under NDA No. 11-0-107.04) 8. Notice of Acceptance No. 14-0916.11 issued to Kuraray America., Inc. for their"SentryGlas© (Clear and White) Interlayer", expiring on 07/04/18. 9. Notice of Acceptance No.16-1117.01 issued to Kuraray America, Inc. for their"Trosifol® Ultraclear, Clear and Color PVB Interlayers", expiring on 07/08/19. Jorge M.Plasencia,P.E. P oduct Control Unit Supervisor NOA No. 17-0420.06 Expiration Date: April 14,2021 Approval Date: September 28,2017 E-3 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance with FBC-51h Edition(2014) and FBC-6t" Edition(2017), issued by manufacturer, dated 08/14/17, signed & sealed by Lynn Miller,P.E. 2. Statement letter of no financial interest, dated 04/18/17,issued by manufacturer, signed& sealed by Lynn Miller, P.E. 3. Letter of lab compliance,part of the above test reports. 4. RER Test Proposal No. 17-0387, dated 05/05/17, signed by Ishaq Chanda, P.E. G. OTHER 1. Notice of Acceptance No. 15-1210.01, issued to PGT Industries, for their Series"5570/2770" Vinyl Sliding Glass Door(Reinforced)—L.M.I.", approved on 03/03/16 and expiring on 04/14/21. Jorge M.Plasencia,P.E. P duct Control Unit Supervisor NOA No. 17-0420.06 Expiration Date: April 14,2021 Approval Date: September 28,2017 E-4