Loading...
HomeMy WebLinkAboutCert for Design Load Compliance Planning&Development Services Department Building&Code Regulations Division I g 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance Project Name: WINDOW OPENING Project Address: 709EASY ST Permit#.- Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: •This certification must be completed,signed,and sealed by the.design professional of record. •Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. Note:Form not required for Interior renovations provided that no exterior structural elements are-affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that apply) L DESIGN CODE-Florida—Building Code 2017 Edition with 20 Supplements using ASCE 7-10 2.Structure Designed as(check one): X Enclosed Partially Enclosed Open 3.Risk Category:—1 XIIIllTV Exposure Category: —8 X C 'D 4.Design Wind Velocity 265 mph 128 ASD -N/A LRFD End Zone Width: 5 ft S.Mean Roof Height: 15.3 ft Roof Pitch: s :12 Parapet: N/A ft 6.Components&Cladding Design Pressures Used:(PSF,based on 10sqft @ IYMRHi dearly label on all plan openings): Zone L- 20.6 Zone 2: 20.6 Zone 3:' 20.6 Zone 4: 35.8 Zone 5: 35.8 Garage: N/A -32.7 -57.0 -84.2— -38.8 -47.9 N/A 7.Design Loads-Floor: N/A PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: NIA PSF Railings: N/A -PLF/CONCENTRATED 8.Were Shear Walls Considered For Structure? X Yes_Not Applicable Explain Why Not. 9.Is A Continuous Load Path Provided?. --2LYes_Not Applicable Explain Why Not: 10.Design Soil Bearing Pressure: 25QQ_PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to comply with the applicable:structurdp. o , rtions of the building codes currently adopted and enforced by St.Lucie CounW el on these plans provide adequate resistance to the design jtstr.CjtWral elements depicted A for Ve2g9as s1 Paul Welch P.E. Cert#&Co Cert Auth. Print Name Paul Welch Inc. UN- W.Biltmore St-Suite#114 Port St.Lucie,FL 40 1994S and-SeA S�l Company Name&Address i 53 "c StCCp1(-Form.4024-1ZtleYssed:3/1511L(JS)