HomeMy WebLinkAboutCert for Design Load Compliance Planning&Development Services Department
Building&Code Regulations Division
I g 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553
Certification for Design Load Compliance
Project Name: WINDOW OPENING
Project Address: 709EASY ST
Permit#.- Occupancy Type: R Construction Type: V
INSTRUCTIONS FOR USE:
•This certification must be completed,signed,and sealed by the.design professional of record.
•Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
Note:Form not required for Interior renovations provided that no exterior structural elements are-affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED:(complete all that apply)
L DESIGN CODE-Florida—Building Code 2017 Edition with 20 Supplements using ASCE 7-10
2.Structure Designed as(check one): X Enclosed Partially Enclosed Open
3.Risk Category:—1 XIIIllTV Exposure Category: —8 X C 'D
4.Design Wind Velocity 265 mph 128 ASD -N/A LRFD End Zone Width: 5 ft
S.Mean Roof Height: 15.3 ft Roof Pitch: s :12 Parapet: N/A ft
6.Components&Cladding Design Pressures Used:(PSF,based on 10sqft @ IYMRHi dearly label on all plan openings):
Zone L- 20.6 Zone 2: 20.6 Zone 3:' 20.6 Zone 4: 35.8 Zone 5: 35.8 Garage: N/A
-32.7 -57.0 -84.2— -38.8 -47.9 N/A
7.Design Loads-Floor: N/A PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:. N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: NIA PSF Railings: N/A -PLF/CONCENTRATED
8.Were Shear Walls Considered For Structure? X Yes_Not Applicable Explain Why Not.
9.Is A Continuous Load Path Provided?. --2LYes_Not Applicable Explain Why Not:
10.Design Soil Bearing Pressure: 25QQ_PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to
comply with the applicable:structurdp. o
, rtions of the building codes currently adopted and enforced by St.Lucie
CounW el on these plans provide adequate resistance to the design
jtstr.CjtWral elements depicted
A
for
Ve2g9as s1
Paul Welch P.E.
Cert#&Co Cert Auth.
Print Name
Paul Welch Inc.
UN-
W.Biltmore St-Suite#114 Port St.Lucie,FL
40
1994S
and-SeA
S�l Company Name&Address i
53
"c
StCCp1(-Form.4024-1ZtleYssed:3/1511L(JS)