Loading...
HomeMy WebLinkAboutNOA, Tuscany Roof Tile RECEPM MIAMI-DADE COUNTY MIAMI-DADE DEC 12 2019 PRODUCT CONTROL SECTION am.- 11805 SW 26 Street,Room 208 .DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Permitting Department Miami,Florida 33175-2474 t)-$OARD AND CODE ADMINISTRATION DIVISION St' j e°U�'r®�T X786)315-2590 F(786)3'15-2599 NOTICE OF ACCEPTANCE (NOA) �L. y www.miamidade.aov/economy Crown Building Products of Florida,LLC ®� 6018 HwY 72 REVIEWED FOR Arcadia,FL 34266 CODE COMPLIANCE SCOPE: ST. LUCIE CO This NOA is being issued under the applicable rules and regulations govern �e on11%Scfnmaterials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Cl Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tuscany Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any iproduct, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 7. The submitted documentation was reviewed by Juan E.Collao,R.A. GLGIi�•(,�� NOA No.: 14-1006.02 miAMI•DADE COUNTY Expiration Date:01/29/20 Approval Date:01/29/15 Page 1 of 7 r ROOFING ASSEMBLY APPROVAL Category: Roofing i-Sub-Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Tuscany Roof Tile, as manufactured by Crown Building Products of Florida, LLC as described in Section 2 of this Notice of Acceptance. For,locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description Tuscany Roof Tile L= 17" TAS 112 Low profile,interlocking, concrete tile equipped W= 13" with two nail holes.For direct deck or battened H=2.3" nail-on,mortar or adhesive set applications. Thickness: 0.5" Trim Pieces L=varies TAS 112 Accessory trim,concrete roof pieces for use at W=varies hips,rakes,ridges and valley terminations. Varying thickness Manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description Manufacturer (With Current NOA) 3WT 2-Component Foam Roof Tile Two component polyurethane 3M Company Adhesive AH-160 foam adhesive. TILE BOND Roof Tile Adhesive Single component polyurethane The Dow Chemical Company foam roof tile adhesive. "Tile Tite"Roof Tile Mortar Premixed,pre-bagged roof tile Bermuda Roof Co. Inc. mortar. Bonsal Roof Tile Mortar Premixed,pre-bagged roof tile Bonsal American mortar. "Quikrete"Roof Tile Mortar,FL-15 Premixed,pre-bagged gray roof The Quikrete Companies,Inc. tile mortar. i 2.2 MANUFACTURING LOCATION 1. Arcadia,FL NOA No.: 14-1006.02 MIAMI•DAD,COUNTY Expiration Date: 01/29/20 Approval Date: 01/29/15 Page 2 of 7 1 2:3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date 'Redland Technologies 7161-03 PA 102&PA 102(A) Dec. 1991 Appendix III 1 7161-03 Appendix II PA 108 (Nail-On) Dec. 1991 Letter PA 108 (Nail-On) Aug. 1994 P0631-01 PA 108 (Mortar Set) July 1!994 P0402 Withdrawal'Resistance Testing of screw Sept. 1993 vs. smooth shank nails The Center for Applied. 94-083 PA 101 (Adhesive Set) April 1994 Engineering,Inc. 94-084 PA 101 (Mortar Set) May 1994 25-7094-(l,4, &7) PA 102 Oct. 1994 25-7183-(1, 2&7) PA 102 Feb. 1995 25-7214-(2&6) PA 102 March; 1995 25-7487-1 PA 102 Dec. 1995 25-7496-(2&3) PA 102 Dec. 1995 25-7804-5 PA 102 Sep. 11996 Celotex Corporation Testing 528454-2-1 PA 101 Sep. !1998 Service 520109-2 PA 101 Dec.11998 Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999 Evaluation Calculations 25-7183 March 1995 Evaluation Calculations 25-7094 February 1996 Evaluation Calculations 25-7496 April; 1996 Evaluation Calculations 25-7584 December 1996 Evaluation Calculations 25-7804b-8 December 1996 Evaluation Calculations 25-7804-4&5 December 1996 Evaluation Calculations 25-7848-6 December 1996 Evaluation Calculations Aerodynamic Multipliers April 1999 Evaluation Calculations Two Patty Adhesive Set System April 1999 American Test Lab of South RT0908.02-14 TAS 112 09/18/14 Florida RT0912.02-14 Restoring Moments 09/18/14 Aerodynamic Multiplier i NOA No.: 14-1006.02 MIAMI•DADE COUNTY Expiration Date: 01/29/20 Approval Date:01/29/15 Page 3 of 7 i 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami-Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance, audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Tuscany Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119,and RAS 120. 4.2 Data For Attachment Calculations I Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight-W (lbf) Length-1 (ft) Width-w (ft) usca RoofTle 10.0 1.42 1.08 mw Table 2: Aerodynamic Multipliers -A (ft) Tile Profile A (ft ) A (ft ) Batten Application Direct Deck Application, Tuscany Roof Tile 0.289 0.313 Table 3: Restoring Moments due to'Gravity- M9 (ft-lbf) Tile 2":1211 3":12" 4 .12 ,5":12 6":12" 7":12" or Profile - - greater Tuscany Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Roof Tile Deck Deck Deck Deck Deck Deck 7.06 7.06 6.99 6.99 6.88 $ 6.73 6.74 6.57 6.57 6.38 6.39 i NOA No.: 14-1006.02 ri MIAMI•DADE COUNTY Expiration Date:01/29/20 1 Approval Date:01/29/15 Page 4 of 7 i Table 4: Attachment Resistance Expressed;as a Moment - Mf(ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Tuscany Roof Tile 2-10d Ring Shank Nails 27.8 37.4 28.8 1-10d Smooth or Screw Shank 8.8 11.8 4.1 Nail 2-10d Smooth or Screw Shank 16.4 21.9 7.1 , Nails 1 #8 Screw 25.8 25.8 22.9 ,2,,3 g�� ,Scare-W 47.1 x`467,.1 49.1 1-10d Smooth or Screw Shank 24.3 24.3 24.2 Nail (Field Clip) 1-10d Smooth or Screw Shank 19.0 19.0 22.1 Nail (Eave Clip) 2-10d Smooth or Screw Shank 35.5 35.5 34.8 Nails (Field Clip) 2-10d Smooth or Screw Shank 31.9 31.9 32.2 Nails (Eave Clip) 2-10d Ring Shank Nails 43.0 67.5 50.9 1 Installation with a 4"tile headlap and fasteners are located a min. of 2'/2"from head of tile. i Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Tuscany Roof Tile AdhesiveZ 26.13 2 See manufacturer's component approval for installation requirements. 3 TILE BOND T' Roof Tile Adhesive; Average weight per patty 11.4 grams. 3MTm 2-Component Foam Roof Tile Adhesive AH-160; Average weight per patty 8 grams. i i NOA No.: 14-1006.02 MIAMI-DARE COUNTY Expiration Date:01/29/20 Approval Date:.01/29/15 Page 5.of 7 II i Table 6: Attachment Resistance Expressed',as a Moment - Mf(ft-lbf) for Single Patty Adhesive Set Systems t Tile Tile Application Minimum Attachment Profile Resistance', Tuscany Roof Tile 3M 2-Component Foam Roof Tile Adhesive AH-160 86.61 3M 2-Component Foam Roof Tile Adhesive AH-160 45.5 4 Large paddy placement of 54 grams of 3MTm 2-Component Foam Roof Tile Adhesive AH-160. 5 Medium paddy placement of 24 grams of 3MTA4 2-Component Foam Roof Tile Adhesive AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance'! TuscanyRoof Tile Mortar Set6 20.6 6 Seespecific mortar manufacturer's Notice of Acceptance 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami-Dade County Product Control Approved". TU Q i C/-?- TuscANY ROOF TILE (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: ! 6.1.1 This Notice of Acceptance. j 6.1.2 Any other documents required by Building Official ,or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 14-1006.02 MIAMI-DADECOUNTY MUR Expiration Date:01/29/20 Approval Date:'01/29/15 Page 6 of 7 - - i I PROFILE DRAWINGS ' I FASTENER HOLE FASTENER HOLE i 1711 13" TuscANY RoOF TILE END OF THIS ACCEPTANCE NOA No.: 14-1006.02 MIAMI•DADE COUNTY Expiration Date: 01/29/20 Approval Date:'01/29/15 Page 7 of 7 i