St.Lucie County
FL# FL17491-R4
Application Type Revision
Code Version 2017
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
( Comments
Archived l^�
Product Manufacturer TAMKO Building Products,Inc. a Com:f�c ✓�
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(_4_U)624-6644 Ext 2305
kerri—eden@tamko.com
Authorized Signature Kerri Eden
kerri—eden@tzimko.com
Technical Representative Kerri EdenOR
pAB�® �
Address/Phone/Email PO Box 1404 VIF-WED1ANC
Joplin,MO 64802.' GOMPL
jg17)624-6644 Ext 2305 ��� ��� ��U14TY
kerri_eden@tamko.com �+ V
Quality Assurance Representative +�o`A
Address/Phone/Email
r Category Roofing
F10:
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Product Evaluation Entity
Evaluation Entity UL LLC
Quality Assurance Entity UL LLC
• Quality Assurance Contract Expiration Date 10/18/2021
Validated By Zachary R. Priest,P.E.
Q Validation Checklist-Hardcopy Received
Certificate of Independence L17 OI Standards o Bus'Business duct-Inde e de e
p R4��_ P
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D2178 2004
ASTM D2626 2004
ASTM D3019 2008
ASTM D3909 2012
ASTM D4601 2004
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGE...GgvjQiz6CDe6kBWHamOORZ5MGW9ggWv13gRZckVYA%3d%3d 11/14/19, 6:26 AM
Page 1 of 2
ASTM D6163 2008
i ASTM D6164 2011
I) ASTM G155 2005
i FM 4470 2012
I UL 1897 2012
UL 790 2004
Equivalence_of Product Standards
Certified By Approved Evaluation Entity
FL17491L_Equiv TAMKO Letter- FBC 2017 Referenced Standards
" 4 Equiva ency�R-df
FL17491 R4 Equiv UL Letter-TAMKO Code RefKE.pdf
(I L174 94 Equiv UL letter for standards for FBC 2017.pdf
Sections from the Code
I
Product Approval Method Method 1 Option C
1
Date Submitted 11/02/2018
I Date Validated 11/02/2018
Date Pending FBC Approval
Date Approved 11/06/2018
Summary of Products, .
I FL# Model,'Number,or Name Description -
17491.1 TAMKO Modified Bitumen Roof TAMKO Modified Bitumen Roof Covering Systems
Covering Systems
Limits of Use Installation Instructions
Approved for use in HVHZ: No F1_17491 R4 II ULFB.R3225 6-22-18.pdf
Approved for use outside HVHZ:Yes Verified By: UL LLC
Impact Resistant: N/A Created by Independent Third Party:
Design Pressure: +0/-120 Evaluation Reports
Other: 1.Acceptable for use on low slope roofs. 2.The F1_17491 R4 AE ULFB.R3225 6-22-18.pdf
design pressure noted herein pertains to one system over one
deck type, refer to evaluation report for all deck types and
maximum design pressures. 3. Refer to UL ER3225-01 Section
9 for Conditions of Use.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
C The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
•� 455,F.S. please click here.
Product Approval Accepts:
i
CreditCard.'__
Safe::
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGE...GgvjQiz6CDe6kBWHam0ORZ5MGW9g9Wvl3gRZckVYA%3d%3d 11/14/19,6:27 AM
Page 2 of 2
UL Evaluation Report
UL ER3225-01
Issued:July 28,2016
Revised:June 22,2018
Visit UL's On-Line Certifications Directory:www.ul.com/erdirectory
for,current status of Report.
UL Category Code: ULFB
CSI MasterFormat®
DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION
Sub-level 2: 07.60 00 r-Membrane.Roofing.
Sub-level 2: 07 61 00—Built-Up Bituminous.Roofing
Sub-level 3: 07 6113—Built-Up Asphalt Roofing
Sub-level 2: 07.62 00—Modified Bituminous Membrane Roofing
Sub-level 3: 07 6216—Styrene-Butadiene-Styrene Modified Bituminous Sheet Roofing
COMPANY:
TAMKO Building Products, Inc.
220 West 4t'Street
Joplin, MO 64802_
www.tamko.com
1.SUBJECT: AWAPLAN,AWASTAR SA,SA CAP,TAM-CAP,AWA-NAILBASE,AWABASE SA,
GLASS BASE,SA BASE,TAM-PLY IV,TAM-PRO 866 PREMIUM SBS ADHESIVE,
TYPE 43,AND VERSA-BASE
2.SCOPE OF EVALUATION
■2015, 2012,:2009 and 2006 International Building Code®(IBC)
■2015, 2012, 2009 and 2006 International Residential Code®.(IRC) .
■ICC ES Acceptance Criteria for Roof-Covering Systems(AC75), Dated July 2010 (Editorially revised
April 2014)
■ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated June 2014
Page 1 of 16
I, .
"a
The products were evaluated for the following properties:
■Roofing Systems for Exterior Fire Exposure (ANSI/UL 790)
■Roofing Systems, Wind Uplift Resistance (ANSI/UL 1897, ANSI/FM 4474)
■Physical Properties(ASTM D1970, ASTM D2178 Type.IV, ASTM D2626, ASTM D4601. Type ll, _
ASTM D3019, ASTM D3909,ASTM-D6163 Type I Grade S, ASTM D6164 Type I Grade S and G,
and ASTM G155)
■Impact Resistance(FM 4470)
3. REFERENCED DOCUMENTS
■ ANSI/UL 790, Eighth Edition, Standard Test Methods for Fire Tests of Roof Coverings
■ ANSI/UL 1897, Seventh Edition, Standard for Tests for Uplift Tests for Roofing Systems
■ ASTM D1970-14, Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet
Materials Used as Steep Roofing Underlayment for Ice Dam Protection
■ ASTM D2178-04, Standard Specification for Asphalt Glass Felt Used in Roofing and Waterproofing
■ ASTM D2626-04, Standard Specification for Asphalt-Saturated and Coated Organic Felt Base Sheet
Used in Roofing _
■ ASTM D4601-04,Standard Specification for Asphalt-Coated Glass Fiber Base Sheet Used in Roofing
■ ASTM D3019-94, Standard Specification for Lap Cement Used with Asphalt Roll Roofing, Non-
Fibered, Asbestos-Fibered, and Non-Asbestos-Fibered
■ ASTM D3909-97b,Standard Specification for Asphalt Roll Roofing(Glass Felt)Surfaced With Mineral
Granules
■ ASTM D6163-00, Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous
Sheet Materials Using Glass Fiber Reinforcements
■ ASTM D6164-11, Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous
Sheet Materials Using Polyester Reinforcements
■ ASTM G155-05a, Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-
Metallic Materials
■ ANSI/FM 4470-2012, Single-Ply, Polymer-Modified Bitumen Sheet, Built-Up Roof(BUR) and Liquid
Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck.Construction
s ANSI/FM 4474-2004, Standard for Evaluating the Simulated Wind Uplift Resistance of Roof
Assemblies Using Static Positive and/or Negative Differential Pressures
■ ICC ES Acceptance Criteria for Membrane Roof-Covering Systems (AC75), Dated April 2014
■ ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated June 2014
4. USES
The styrene-butadiene-styrene (SBS) modified bitumen and built-up roofing felts and base sheets
described in this report are used as roof coverings in mechanically fastened or fully adhered Class A, B, or
C roof assemblies installed on combustible or non-combustible roof decks.
5. PRODUCT DESCRIPTION
Page 2 of 16
r •
The membrane roofing systems described in this report consist of asphaltic roofing membranes, base
sheets andply sheets, insulation where used, barrier board or slip sheet where used, flashing, mechanical
fasteners and adhesives that are installed on combustible or non-combustible roof decks.
The roofing assemblieg"incorporating the'niembranes comply with-the-following properties when installed
as described in this report.
Fire Classification: Roofing assemblies covered under this report have been tested for fire classification
Class A, B, or C in accordance with ANSI/UL790, as required by Section 1505.1 of 2015, 2012, 2009 and
2006 IBC and Section R902.1 of the 2015, 2012, 2009 and 2006 IRC.
The roofing assemblies incorporating the membranes comply with the following properties when installed
as described in this report.
Wind Uplift Resistance: Roofing assemblies covered in this report have been tested for wind uplift
resistance in accordance with ANSI/UL 1897 or ANSI/FM Approvals 4474 Appendix D: 12x24 Simulated
Wind Uplift Pressure Test Procedure and Florida Building Code Test Protocols for the High Velocity
Hurricane Zone (HVHZ) Testing Application Standard (TAS) No. 114-95, Appendix J: Test Procedure for
12 Foot By 24 Foot Simulated Uplift Pressure Resistance of Roof System Assemblies, and therefore qualify
for use as roofing systems under Section 1504.3.1 of the 2015, 2012, 2009 and 2006 IBC.
The roofing assemblies shall be designed to resist the design wind load pressures for components and
cladding in accordance with Section 1609.1 of the 2015, 2012, 2009 and 2006 IBC and Section R905.1 of
the 2015, 2012, 2009 and 2006 IRC.
Physical Properties: The roofing membranes covered under this Report have been tested for physical
properties in accordance with ASTM D2178 Type IV, ASTM D4601 Type II, ASTM D3019, ASTM D3909,
ASTM D2626,ASTM D 6163, Type I, ASTM D6164, Type I, and ASTM G155, and therefore qualify for use
under Section 1507.10.2 and Section 1504.6 of the 2015, 2012, 2009 and 2006 IBC and Section R905.9.2
of the 2015, 2012, 2009 and 2006 IRC.
Impact Test: The asphaltic roofing membranes covered under this report have been tested for impact
resistance in accordance with "Resistance.to Foot Traffic Test" in Section 5.5 of FM 4470 and therefore
qualify for use as low-slope roof coverings covered under Section 1504.7 of the 2015,2012,2009 and 2006
IBC.
6.1 Built-up Roofing Felts and Membranes:
6.1.1 SA CAP: Self-adhering, granule surfaced roof covering with polyester mat reinforcement
coated in modified asphalt. The membrane is supplied in 142 mils thick rolls 3.28 Feet(1 m)
wide by 33.52 feet(10.22 m) long and complies with ASTM D6164, Type I.
5.1.2 AWAPLAN: Granule-surfaced modified bitumen roof covering with polyester mat
reinforcement coated in modified asphalt. The membrane is supplied in 141 mils thick rolls
3.28 Feet(1 m)wide by 33.42 feet(10.19 m) long and complies with ASTM D6164, Type I.
6.1.3 AWASTAR SA: Self-adhering, smooth surfaced roof covering with polyester mat
reinforcement coated in modified asphalt. The membrane is supplied in 141 mils thick rolls
3.28 Feet(1 m)wide by 33.42 feet(10.19 m) long and complies with ASTM D6164, Type I.
6.1.4 TAM-CAP: A mineral-surfaced BUR roofing cap sheet with nonwoven fiberglass
reinforcement coated with asphalt. The membrane is supplied in rolls 3.28 feet(1 m)wide
by 32.92 feet(10.03 m) long and complies with ASTM D3909.
6.1.6 VERSA-BASE: SBS-modified bitumen base sheet with asphalt coated fiberglass
reinforcement. The membrane is supplied in rolls 3.28 feet (1 m) wide by 48.17 feet
(14.68 m) long and complies with ASTM D6163, Type I.
Page 3 of 16
C6.1.66.1.6 GLASS BASE: Asphalt coated fiberglass reinforced base sheet with fiberglass mat
reinforcement coated with asphalt. The base sheet is supplied in rolls 3.28 feet (1 m)
wide by 97.5 feet(29.72 m) long and complies with ASTM D4601, Type II.
6.1.7 YAM-PLY sp orced G1 ply sheet. e s s
in rolls 3.28 feet(1 m)wide by 161.75 feet(49.30 m) long and complies with ASTM D2178,
Type IV.
6.1.8 TYPE 43: Asphalt coated felt Type 15 ply sheet. The base sheet is supplied in rolls 3 feet
(1 m)wide by 72 feet(21.95 m) long and complies with ASTM D2626.
6.1.9 AWA NAILBASE: SBS-modified bitumen base sheet with asphalt coated fiberglass
reinforcement. The membrane is supplied in rolls 3.28 feet (1 m) wide by 97.5 feet
(29.72 m) long and complies with ASTM D4601, Type II.
6.1.10 AWABASE SA: Self-adhering, smooth surfaced base sheet with fiberglass mat
reinforcement coated in modified asphalt. The base sheet is supplied in rolls 3.28 feet
(1 m)wide by 67.83 feet(20.68 m) long and complies with ASTM D4601, Type II.
6.1.11 $A BASE: Self-adhering, fiberglass reinforced SBS-modified bitumen membrane. The
membrane is supplied in rolls 3.26 feet(1 m)wide by 65.83(20.1 m) long and complies with
ASTM D1970.
6.2 Adhesive:
6.2.1 TAMPRO 866 PREMIUM SBS ADHESIVE: Brush"or squeegee applied Adhesive asphaltic
lap cement with reinforcing minifibers and rubberized polymers. The adhesive is supplied in 3, 5,
and 55-gallon containers, and is ASTM D3019 compliant.
6.3 Insulation:
Foam plastic insulation when used shall have a flame spread index of not more than 75 when
tested at the maximum thickness intended for the use in accordance with ANSI/UL 723 or ASTM E
84 to qualify for use under Section 2603.3 and Exception 3 of the 2015, 2012, 2009 and 2006 IBC.
To qualify for use under Section 2603.4.1.5 of the 2015,2012,2009 and 2006 IBC,a thermal barrier
is not required for foam plastic insulation that is part of a Class A, B or C roof-covering assembly,
provided the assembly with foam plastic insulation complies with FM 4450 or UL 1256.
6.4 Fasteners:
Fasteners used to mechanically fasten insulation, membranes, and base and ply sheets to the roof
deck, shall be corrosion resistant and shall be one.of the fasteners identified in the Tables of this
Report.
6.6 Asphalts and Adhesive:
When specified in the roofing assemblies,hot roofing asphalt shall conform to ASTM D312,Type III
or Type IV. TAM-PRO 856 Premium SBS adhesive used to bond TAMKO membranes to the
insulation or roofing substrate shall be as noted in the Tables of this Report.
G. INSTALLATION
TAMKO roofing felts, base sheets, membranes and cap sheets shall be installed in accordance with the
applicable code, this report and the manufacturer's published installation instructions. The roof covering
materials shall be installed in accordance with Section 1507.10 of the 2015, 2012, 2009 and 2006 IBC or
Section R905.9 of the 2015, 2012, 2009 and 2006 IRC as applicable, except as noted in this report.
Page 4 of 16