HomeMy WebLinkAboutProduct Approval MIAMI-DADE FILEC0PR0yDcT'AM'_DADE COUNTY
CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCESLW
11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION `�j Miami,Florida 33175-2474
WF®RT(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade. ov/econom
Tarco Specialty Products,Inc. ST. LUCIE COU �
One Information Way,Suite 225
Little Rock,AR 72202 Bow ����
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Tarco Roofing Membranes and Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 16-1116.09 and consists of pages 1 through 15.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 18-1105.05
MIAMI-DADE COUNTY Expiration Date: 01/25/22
Approval Date: 09/26/19
Page 1 of 15
v
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: Asphalt, SBS,Polyester
SCOPE:
This acceptance is for Tareo Roofing Membrane and Underlayments,for use with approved prepared roof
assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved
adhesives,fasteners and fastener densities, as described in this Notice of Acceptance; designed to comply with the
Florida Building Code,including the High Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Specification Product Descrintion
30#ASTM 3' x 72"rolls ASTM D226 Type II Asphalt saturated felt underlayment
Specification Felt
Manufacturing
Location#1
EasyLay 3' x 133' 4"rolls ASTM D226 Type II Sheet material comprising a polyester
Manufacturing substrate coated with bituminous coating for
Location#2 use as an underlayment in roofing
applications. Designed as a shingle and metal
roofing underlayment and for use in tile
roofing assemblies when used with an
approved TAS 103 tile underlayment cap
sheet.
Fiberglass Mineral 3' x 36'rolls ASTM D3909 Mineral surfaced glass fiber reinforced,
Surfaced Roll asphalt coated roll roofing for hot mop or cold
Roofing process application.
Manufacturing
Location#1
ASTM Organic Tile 3' x 36'rolls ASTM D6380 Asphalt saturated granular surfaced felt
Underlayment Type II underlayment for hot mop application.
Manufacturing
Location#1
EasyMop SBS 3' x 36'rolls TAS 104 Granular surfaced polyester reinforced, SBS
Manufacturing modified bituminous membrane for hot mop or
Location#1 cold process application. Designed as a tile
roofing underlayment.
NOA No.: 18-1105.05
MIAMI-DADE COUNTY
...� � Expiration Date: 01/25/22
Approval Date: 09/26/19
Page 2 of 15
Fast90 3' x 36' rolls TAS 103 Granular surfaced,asphalt-impregnated
Manufacturing ASTM D249 organic felt reinforced, bituminous sheet
Location#1 ASTM D6380 material with a self-adhesive bottom layer, for
use as an underlayment in sloped roof
assemblies. Designed as a tile roofing
underlayment.
PS200HT 3' x 66'8"rolls TAS 103 Fabric surfaced,fiberglass reinforced,SBS
Manufacturing ASTM D1970 modified bituminous sheet material with a
Location#2 self-adhesive bottom layer,for use as an
underlayment in sloped roof assemblies.
Designed as a shingle,tile and metal roofing
underlayment.
PS200Mu 3' x 66'8"rolls ASTM D1970 Film surfaced,fiberglass reinforced, SBS
Manufacturing modified bituminous sheet material with a
Location#1  self-adhesive bottom layer,for use as an
underlayment in sloped roof assemblies.
Designed as a metal and shingle roofing
underlayment.
MS300 3' x 66'8"rolls ASTM D1970 Fine granular surfaced,fiberglass reinforced,
Manufacturing 3' x 33'4"rolls bituminous sheet material with a self-adhesive
Location#1  bottom layer, for use as an underlayment in
sloped roof assemblies. Designed as an ice
and water shield,and a shingle roofing
underlayment.
SS400 3' x 66'8"rolls ASTM D1970 Smooth surfaced,fiberglass reinforced,
Manufacturing 3' x 33'4"rolls bituminous sheet material with a self-adhesive
Location#1  bottom layer,for use as an underlayment in
sloped roof assemblies. Designed as an ice
and water shield, and a shingle and metal
roofing underlayment.
NR500HT 3' x 66'8"rolls ASTM D1970 Film surfaced,non-reinforced,bituminous
Manufacturing sheet material with a self-adhesive bottom
Location#3 layer,for use as an underlayment in sloped
roof assemblies. Designed as an ice and water
shield, and a shingle and metal roofing
underlayment.
NR600 Ultra 3' x 72' rolls TAS 103 Film surfaced,non-reinforced, SBS modified
bituminous sheet material with a self-adhesive
Manufacturing bottom layer, for use as an underlayment in
Location#1 sloped roof assemblies. Designed as a shingle,
tile and metal roofing underlayment.
NOA No.: 18-1105.05
hnaMi•uAne cout�7�r Expiration Date: 01/25/22
Approval Date: 09/26/19
Page 3 of 15
MANUFACTURING LOCATION:
1. Greencastle,PA
2. Belton,TX
3. Coshocton,OH
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/ReDort Date
Atlantic&Carribean Roof ACRC06-013 TAS 103 06/14/06
Consulting,LLC
PRI Asphalt Technologies TOT-003-02-01 ASTM D226 Type II 08/22/02
TOT-029-02-01 TAS 110,ASTM D249&D 6380 07/05/05
TOT-030-02-01 TAS 110,ASTM D249&D 6380 07/05/05
TOT-041-02-01 TAS 110,ASTM D226 Type 11 05/24/06
TOT-042-02-01 ASTM D4798&ASTM G155 05/22/07
Trinity I ERD T3580.10.06-2 TAS 103 10/26/06
T3580.10.06 TAS 103,ASTM D6380 10/12/06
T30160.08.09-R1 ASTM D1970 10/12/10
T10550.07.08 ASTM D4798&ASTM D1970 07/30/08
T32530.08.10 ASTM D1970 08/17/10
T33190.08.10 TAS 103 08/06/10
T43930.09.13-R2 TAS 104 09/11/13
T40790.04.12 ASTM D6380 04/06/12
T40780.04.12 ASTM D3909 04/06/12
T37610.07.11 TAS 114-D 07/29/11
IRT-Arcon IRT07-0006 ASTM D1970 07/11/07
IRT 07-0036 ASTM D1970 02/22/08
IRT08-0002 ASTM D1970 02/22/08
NEMOjetc. TAR-SC8020.06.18 TAS 103,D4798 06/05/18
4j-TAR-I9-SSUDL- TAS 110 08/27/19
OLA
NOA No.: 18-1105.05
MIAMI-DAD;COUNTY Expiration Date: 01/25/22
Approval Date: 09/26/19
Page 4 of 15
APPROVED ASSEMBLIES-30#ASTM SPECIFICATION FELT:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation Requirements and General Limitations below.
System E(1): See Installation Requirements and General Limitations below.
INSTALLATION REQUIREMENTS—30#ASTM SPECIFICATION FELT:
1. 30#ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations(NBCA)when installing 30#Felt.
3. During installation of 30#Felt, comply with Occupational Safety and Health Administration(OSHA)safety
standards;use common sense measures and adequate safety precautions to prevent accidents.
4. 30#ASTM Specification Felt shall be installed with a minimum 4"end lap in a shingle layer fashion and
fastened as required by applicable system assemblies NOA or FBC 1518.2.
GENERAL LIMITATIONS—30#ASTM SPECIFICATION FELT:
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. 30#ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing
ASTM D226 Type II felt as a component part of an assembly in the Notice of Acceptance.
4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
C-DADENOA No.: 18-1105.05
COUNTY Expiration Date: 01/25/22
Approval Date: 09/26/19
Page 5 of 15
REVIEWED FOR MIAMI-DADE COUNTY
*DE COMPLIANCE PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC URC dip ` ' '�'�/ 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION ' p L CO V N � ■ Miami,Florida 33175-2474
BOCC T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.nnamidade.gov/economy
L.V.Thompson,Inc. '
5015 E.Hillsborough Avenue COPTampa,FL.33610
BILE
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 5V Crimp Roof Panel
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this.NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 11-0808.09 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-1012.17
MIAMI•DADECOUNTY Expiration Date: 11/30721
Approval Date: 11/23/16
Page 1 of 5
ROOFING ASSEMBLY APPROVAL: "
Category Roofing.
Sub-Category: Non=Structural Metal�Roofing
Material: Steel
Deck Type: Wood
Maximum Design Pressure....., See Table A "
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Product
Specifications Description
"5V"Steel Roofing 1=varies TAS 125 Metal Roof Panel conforming with
Panel w=24" ASTM A792 coated with"Aluzinc.
h=%Z"
Min.Thickness 0.019"
Min yield strength:48ksi
Trim Pieces 1=varies TAS 110 Standard flashing and trim pieces.
w=varies Manufactured for each panel width. "
Thickness 0.0276.
MANUFACTURING LOCATION:
1. Tampa,FL.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Reyort Date
PRI Construction Materials LVTI-008-02-01 TAS-100 08/07/06
Technologies LLC LVTI-020-02-03 ASTM B 117/TAS 110 10/25/16
LVTI-021-02-01 TAS 125 10/26/16
LVTI-020-02-02 ASTM G 155 11/16/16
NOA No.:16-1012.17
rnarn•DADE COuNrr Expiration Date: 11/30/21
Approval Date: 11/23/16-
Page
1/23/16Page 2 of 5
- D
! APPROVED ASSEMBLIES:
System: 115V-Crimp"Metal Panels
Deck Type: Wood,Non-Insulated
Deck Description: 15/32" or greater plywood or wood plank.
Slope Range: 2": 12"or greater
Maximum Uplift See Table A below
Pressure:
Deck Attachment: In accordance with applicable Building Code,but in no case shall it be less than 8d annular
ring shank nails spaced 6"o.c.In reroofing,where the deck is less than 19/32"thick
(Minimum 15/3.2"). The above attachment method must be in addition to existing
attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type I installed with a minimum 19"
side-laps and 6"end-lap fastened with corrosion resistant tin-caps and 1'/4"annular ring-
shank nails,spaced 6"o.c.at all laps and two staggered rows 12"o.c. in the field of the roll;
TU Plus installed over the ASTM D 226
followed by one layer of Polyglass Type I. Refer
to Polyglass USA current published installation instructions.
Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation# 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with L.V.Thompson Inc.'s current published installation instructions.
Metal Panels and Install the "5V" Steel Roof Panels and accessories in compliance with LV Thompson Inc.'s
Accessories: current, published installation instructions and details. Flashing, penetrations, valley
construction and other details shall be constructed in compliance with the minimum
requirements provided in Roofing Application Standards RAS 133.
Panel fasteners shall be#911H self tapping screws with sealing washer of sufficient length
to penetrate through the sheathing a minimum of 3/16 inch.
Fasteners shall be installed at high points of panel ribs(see Detail A) at a maximum spacing
as listed in Table A below parallel to the slope.(see Detail B)
Fasteners shall be installed at a maximum of 12"o.c.at panel edge.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas Field Perimeter and Corners
Maximum Design Pressure -71.25 psf -127.5 psf
Maximum Fastener Spacing 16"o.c. 8"o.c.
1. Extrapolation shall not be allowed
NOA No.: 16-1012.17
MIAMI•oAUE courant .Expiration Date: 11/30/21
Approval Date: 11/23/16
Page 3 of 5
SYSTEM LIMITATIONS
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2• The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e. field,perimeters, '
and comers).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones(i.e.perimeters,extended comers and comers).
3. Panels may be rolls formed in continuous lengths from eave to ridge.Maximum lengths shall be as described in
Roofing Application Standard RAS 133
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement:
"Miami-Dade County Product Control Approved"or with the Miami-Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo,and/or model.
MIAMI•DADE COUNTY
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
MIAM4DADE COUNTY
NOA No.: 16-1012.17
• Expiration Date: 11/30/21
Approval Date: 11/23/16
Page 4 of 5
.+ PROFILE DRAWINGS:
DETAIL A
24"Coverage
112"
Minimum #9HHself tapping
screws w/ self sealing.
"Minimum penetration
through the deck
See Table A
Overlap
Overlap
END OF THIS ACCEPTANCE
NOA No.: 16-1012.17
QMIAMMUDADE coutvrr Expiration Date: 11/30/21
Approval Date: 11/23/16
Page 5 of 5