Loading...
HomeMy WebLinkAboutProduct Approval MIAMI-DADE FILEC0PR0yDcT'AM'_DADE COUNTY CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCESLW 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION `�j Miami,Florida 33175-2474 WF®RT(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade. ov/econom Tarco Specialty Products,Inc. ST. LUCIE COU � One Information Way,Suite 225 Little Rock,AR 72202 Bow ���� SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tarco Roofing Membranes and Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 16-1116.09 and consists of pages 1 through 15. The submitted documentation was reviewed by Freddy Semino NOA No.: 18-1105.05 MIAMI-DADE COUNTY Expiration Date: 01/25/22 Approval Date: 09/26/19 Page 1 of 15 v ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Underlayment Material: Asphalt, SBS,Polyester SCOPE: This acceptance is for Tareo Roofing Membrane and Underlayments,for use with approved prepared roof assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved adhesives,fasteners and fastener densities, as described in this Notice of Acceptance; designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Specification Product Descrintion 30#ASTM 3' x 72"rolls ASTM D226 Type II Asphalt saturated felt underlayment Specification Felt Manufacturing Location#1&#2 EasyLay 3' x 133' 4"rolls ASTM D226 Type II Sheet material comprising a polyester Manufacturing substrate coated with bituminous coating for Location#2 use as an underlayment in roofing applications. Designed as a shingle and metal roofing underlayment and for use in tile roofing assemblies when used with an approved TAS 103 tile underlayment cap sheet. Fiberglass Mineral 3' x 36'rolls ASTM D3909 Mineral surfaced glass fiber reinforced, Surfaced Roll asphalt coated roll roofing for hot mop or cold Roofing process application. Manufacturing Location#1 ASTM Organic Tile 3' x 36'rolls ASTM D6380 Asphalt saturated granular surfaced felt Underlayment Type II underlayment for hot mop application. Manufacturing Location#1 EasyMop SBS 3' x 36'rolls TAS 104 Granular surfaced polyester reinforced, SBS Manufacturing modified bituminous membrane for hot mop or Location#1 cold process application. Designed as a tile roofing underlayment. NOA No.: 18-1105.05 MIAMI-DADE COUNTY ...� � Expiration Date: 01/25/22 Approval Date: 09/26/19 Page 2 of 15 Fast90 3' x 36' rolls TAS 103 Granular surfaced,asphalt-impregnated Manufacturing ASTM D249 organic felt reinforced, bituminous sheet Location#1 ASTM D6380 material with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a tile roofing underlayment. PS200HT 3' x 66'8"rolls TAS 103 Fabric surfaced,fiberglass reinforced,SBS Manufacturing ASTM D1970 modified bituminous sheet material with a Location#2 self-adhesive bottom layer,for use as an underlayment in sloped roof assemblies. Designed as a shingle,tile and metal roofing underlayment. PS200Mu 3' x 66'8"rolls ASTM D1970 Film surfaced,fiberglass reinforced, SBS Manufacturing modified bituminous sheet material with a Location#1 &#2 self-adhesive bottom layer,for use as an underlayment in sloped roof assemblies. Designed as a metal and shingle roofing underlayment. MS300 3' x 66'8"rolls ASTM D1970 Fine granular surfaced,fiberglass reinforced, Manufacturing 3' x 33'4"rolls bituminous sheet material with a self-adhesive Location#1 &#2 bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield,and a shingle roofing underlayment. SS400 3' x 66'8"rolls ASTM D1970 Smooth surfaced,fiberglass reinforced, Manufacturing 3' x 33'4"rolls bituminous sheet material with a self-adhesive Location#1 &#2 bottom layer,for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. NR500HT 3' x 66'8"rolls ASTM D1970 Film surfaced,non-reinforced,bituminous Manufacturing sheet material with a self-adhesive bottom Location#3 layer,for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. NR600 Ultra 3' x 72' rolls TAS 103 Film surfaced,non-reinforced, SBS modified bituminous sheet material with a self-adhesive Manufacturing bottom layer, for use as an underlayment in Location#1 sloped roof assemblies. Designed as a shingle, tile and metal roofing underlayment. NOA No.: 18-1105.05 hnaMi•uAne cout�7�r Expiration Date: 01/25/22 Approval Date: 09/26/19 Page 3 of 15 MANUFACTURING LOCATION: 1. Greencastle,PA 2. Belton,TX 3. Coshocton,OH EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/ReDort Date Atlantic&Carribean Roof ACRC06-013 TAS 103 06/14/06 Consulting,LLC PRI Asphalt Technologies TOT-003-02-01 ASTM D226 Type II 08/22/02 TOT-029-02-01 TAS 110,ASTM D249&D 6380 07/05/05 TOT-030-02-01 TAS 110,ASTM D249&D 6380 07/05/05 TOT-041-02-01 TAS 110,ASTM D226 Type 11 05/24/06 TOT-042-02-01 ASTM D4798&ASTM G155 05/22/07 Trinity I ERD T3580.10.06-2 TAS 103 10/26/06 T3580.10.06 TAS 103,ASTM D6380 10/12/06 T30160.08.09-R1 ASTM D1970 10/12/10 T10550.07.08 ASTM D4798&ASTM D1970 07/30/08 T32530.08.10 ASTM D1970 08/17/10 T33190.08.10 TAS 103 08/06/10 T43930.09.13-R2 TAS 104 09/11/13 T40790.04.12 ASTM D6380 04/06/12 T40780.04.12 ASTM D3909 04/06/12 T37610.07.11 TAS 114-D 07/29/11 IRT-Arcon IRT07-0006 ASTM D1970 07/11/07 IRT 07-0036 ASTM D1970 02/22/08 IRT08-0002 ASTM D1970 02/22/08 NEMOjetc. TAR-SC8020.06.18 TAS 103,D4798 06/05/18 4j-TAR-I9-SSUDL- TAS 110 08/27/19 OLA NOA No.: 18-1105.05 MIAMI-DAD;COUNTY Expiration Date: 01/25/22 Approval Date: 09/26/19 Page 4 of 15 APPROVED ASSEMBLIES-30#ASTM SPECIFICATION FELT: Deck Type: See Installation Requirements and General Limitations below. Deck Description: See Installation Requirements and General Limitations below. System E(1): See Installation Requirements and General Limitations below. INSTALLATION REQUIREMENTS—30#ASTM SPECIFICATION FELT: 1. 30#ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NBCA)when installing 30#Felt. 3. During installation of 30#Felt, comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents. 4. 30#ASTM Specification Felt shall be installed with a minimum 4"end lap in a shingle layer fashion and fastened as required by applicable system assemblies NOA or FBC 1518.2. GENERAL LIMITATIONS—30#ASTM SPECIFICATION FELT: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. 30#ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing ASTM D226 Type II felt as a component part of an assembly in the Notice of Acceptance. 4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. C-DADENOA No.: 18-1105.05 COUNTY Expiration Date: 01/25/22 Approval Date: 09/26/19 Page 5 of 15 REVIEWED FOR MIAMI-DADE COUNTY *DE COMPLIANCE PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC URC dip ` ' '�'�/ 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION ' p L CO V N � ■ Miami,Florida 33175-2474 BOCC T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.nnamidade.gov/economy L.V.Thompson,Inc. ' 5015 E.Hillsborough Avenue COPTampa,FL.33610 BILE SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 5V Crimp Roof Panel LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this.NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 11-0808.09 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. NOA No.: 16-1012.17 MIAMI•DADECOUNTY Expiration Date: 11/30721 Approval Date: 11/23/16 Page 1 of 5 ROOFING ASSEMBLY APPROVAL: " Category Roofing. Sub-Category: Non=Structural Metal�Roofing Material: Steel Deck Type: Wood Maximum Design Pressure....., See Table A " TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Specifications Description "5V"Steel Roofing 1=varies TAS 125 Metal Roof Panel conforming with Panel w=24" ASTM A792 coated with"Aluzinc. h=%Z" Min.Thickness 0.019" Min yield strength:48ksi Trim Pieces 1=varies TAS 110 Standard flashing and trim pieces. w=varies Manufactured for each panel width. " Thickness 0.0276. MANUFACTURING LOCATION: 1. Tampa,FL. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Reyort Date PRI Construction Materials LVTI-008-02-01 TAS-100 08/07/06 Technologies LLC LVTI-020-02-03 ASTM B 117/TAS 110 10/25/16 LVTI-021-02-01 TAS 125 10/26/16 LVTI-020-02-02 ASTM G 155 11/16/16 NOA No.:16-1012.17 rnarn•DADE COuNrr Expiration Date: 11/30/21 Approval Date: 11/23/16- Page 1/23/16Page 2 of 5 - D ! APPROVED ASSEMBLIES: System: 115V-Crimp"Metal Panels Deck Type: Wood,Non-Insulated Deck Description: 15/32" or greater plywood or wood plank. Slope Range: 2": 12"or greater Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable Building Code,but in no case shall it be less than 8d annular ring shank nails spaced 6"o.c.In reroofing,where the deck is less than 19/32"thick (Minimum 15/3.2"). The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type I installed with a minimum 19" side-laps and 6"end-lap fastened with corrosion resistant tin-caps and 1'/4"annular ring- shank nails,spaced 6"o.c.at all laps and two staggered rows 12"o.c. in the field of the roll; TU Plus installed over the ASTM D 226 followed by one layer of Polyglass Type I. Refer to Polyglass USA current published installation instructions. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation# 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with L.V.Thompson Inc.'s current published installation instructions. Metal Panels and Install the "5V" Steel Roof Panels and accessories in compliance with LV Thompson Inc.'s Accessories: current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Panel fasteners shall be#911H self tapping screws with sealing washer of sufficient length to penetrate through the sheathing a minimum of 3/16 inch. Fasteners shall be installed at high points of panel ribs(see Detail A) at a maximum spacing as listed in Table A below parallel to the slope.(see Detail B) Fasteners shall be installed at a maximum of 12"o.c.at panel edge. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corners Maximum Design Pressure -71.25 psf -127.5 psf Maximum Fastener Spacing 16"o.c. 8"o.c. 1. Extrapolation shall not be allowed NOA No.: 16-1012.17 MIAMI•oAUE courant .Expiration Date: 11/30/21 Approval Date: 11/23/16 Page 3 of 5 SYSTEM LIMITATIONS 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2• The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e. field,perimeters, ' and comers).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended comers and comers). 3. Panels may be rolls formed in continuous lengths from eave to ridge.Maximum lengths shall be as described in Roofing Application Standard RAS 133 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami-Dade County Product Control Approved"or with the Miami-Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo,and/or model. MIAMI•DADE COUNTY 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAM4DADE COUNTY NOA No.: 16-1012.17 • Expiration Date: 11/30/21 Approval Date: 11/23/16 Page 4 of 5 .+ PROFILE DRAWINGS: DETAIL A 24"Coverage 112" Minimum #9HHself tapping screws w/ self sealing. "Minimum penetration through the deck See Table A Overlap Overlap END OF THIS ACCEPTANCE NOA No.: 16-1012.17 QMIAMMUDADE coutvrr Expiration Date: 11/30/21 Approval Date: 11/23/16 Page 5 of 5