Loading...
HomeMy WebLinkAboutProduct Approval CREEK JOHNS MANVILLE CORPORATION PVC&TPO Single Ply Roofing Systems TECHNICAL SERVICES. LLC APPENDIX C —APPROVED ASSEMBLIES FOR JIM TPO SINGLE-PLY MEMBRANES Mechanically Fastened Assemblies over Steel Deck New, Existin , or Recover System Deck Base Base Top Top Insulation Membrane Membrane emrane Attachment MDP No. Detail Insulation Insulation Attachment (pso Attachment OPTIONAL Preliminarily 37.5 S-M-4 G33. F.L6, INSULATION Secured or OPTIONAL JM TPO Attached in-lap 12-inch o.c.with (Lim.7; S24 under min, secured with top Cover Board Preliminarily Secured HL Fasteners&Plat(Min.60 mil) es; 1.5-inch E3 layer Fastener rows max.90-inch inch o.c. H OPTIONAL Preliminarily HV 5 S-M-S G33, H1, INSULATION Secured or OPTIONAL JM TPO Attached in-lap 12-inch o.c.with (Lim.7; L6. SH24 under min. secured with top Cover Board Preliminarily Secured (Min.60 mil) HL Fasteners&Plates: Non- 1.5-inch E3 layer Fastener rows max. 90-inch o.c. HVHZ OPTIONAL Preliminarily (-30 S-M-6 G33. P, L6, INSULATION Secured or OPTIONAL JM TPO Attached in-lap 12-inch o.c.with Preliminarily Secured Extra HL Fasteners&Plates. Lim.7; S24 under min. secured with top Cover Board (Min.60 mil) 1.5-inch E3 layer Fastener rows max. 138-inch o.c. Non- HVHZ) OPTIONAL Preliminarily G33, P. L6, INSULATION Secured or OPTIONAL Attached in-lap 12-inch o.c.with S-M-7 Preliminarily Secured JM 60 HL Fasteners&Plates; (45 S24 under min. secured with top Cover Board (Min.60 mil) Lim 7) 1.5-inch E3 layer Fastener rows max.66-inch o.c. OPTIONAL Preliminarily Attached in-lap 12-inch o.c.with S-M-B G80, F2W. INSULATION Secured or OPTIONAL High Load Fasteners and JM -45 L6, S24 under min. secured with top Cover Board Preliminarily Secured JM TPO High Load Plus Plates; (Lim.7) OPTIONAL Preliminn 1-inch la Fastener rows max.90-inch o.c. arily S-M-9 G80.F1, INSULATION Secured or OPTIONAL JM TPO or Attached in-lap 12-inch o.c.with L6. S18 under min, secured with top Cover Board Preliminarily Secured JM TPO FB Extra HL Fasteners&Plates; -45 1.5-inch E3 layer Fastener rows max. 114-inch o.c. (Lim.7) OPTIONAL Preliminarily S-M-10 G80. F1. INSULATION Secured or OPTIONAL JM TPO or Preliminarily �5 Attached in-lap 6-inch o.c.with L6. S18 under min. secured with top Cover Board Secured JM TPO FB HL Fasteners&Plates: (Lim.7) 1.5-inch E3 layer Fastener rows max. 114-inch o.c. OPTIONAL Preliminarily S-M-11 G80, F1. INSULATION Secured or OPTIONAL Attached in-lap 6-inch o.c.with Preliminarily Secured JM TPO or -52.5 L6. S18 under min. secured with top Cover Board y JM TPO FB Extra HL Fasteners&Plates; (Lim.7) 1.5-inch E3 la er Fastener rows max. 114-inch o.c. OPTIONAL Preliminarily S-M-12 G80.F1, INSULATION Secured or OPTIONAL Attached in-lap 6-inch o.c.with 60 L6, S18 under min, secured with top Cover Board Preliminarily Secured JM TPO HL Fasteners&Plates; 1.5-inch E3 layer Fastener rows max.90-inch o.c. (Lim.7) OPTIONAL Preliminarily S-M-13 G33, P,L6 INSULATION Secured or OPTIONALAttached in-lap 6-inch o.c.with Preliminarily Secured HL Fasteners&Plates:JM TPO or -60 under min. secured with top Cover Board JM TPO F8 1-inch E3 layer Fastener rows max. 114-inch o.c. (Lim.7) JMC13003.13 FL16758-R13 Page 42 of 46 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. JOHNS MANVILLE CORPORATION CREEKPVC 8 TPO Single Ply Roofing Systems 14 TECHNICAL SERVICES. LLC, APPENDIX C —APPROVED ASSEMBLIES FOR JM TPO SINGLE-PLY MEMBRANES APPROVED ASSEMBLIES FOR JM TPO SINGLE-PLY MEMBRANES The following notes shall be observed when using the assembly tables below. 1. Allowable pressures were calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and NOMENCLATURE sections of this evaluation when using the table(s)below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system. 5. JM Vapor Barrier SA may be installed direct to deck prior to installing the roof assembly components for the following assembly types: C-M-#. C-W-#. LC-M-#, LC-W-#, LS-M-#, LS-W-#, S-M-#, S-W-#,W-M-#,and W-W-# 6. As Tested information for roof deck construction is provided for information only. The addition of the As Tested deck information does not obviate the requirement for rational design of the roof deck and roof deck attachment in accordance with FBC requirements. Assembly System Numbers and Definitions C-A-t Adhered Assemblies over Concrete Deck New or Existing) C-AM-# Assemblies with Adhered Membranes over Insulated Concrete Deck New,Existing,or Recover C-M_& Mechanically Fastened Assemblies over Concrete Deck C-W-tt Induction Welded Assemblies over Concrete Deck CW-A-# Adhered Assemblies over Cementitious Wood Fiber Decks New or Existing) G-A-# Assemblies with All Layers Adhered over Gypsum Deck New or Existing) G-AM-# Assemblies with Adhered Membranes over Insulated Gypsum Deck New or Existing) LC-A-# Adhered Lightweight Concrete Assemblies over Concrete Deck New or Existing) LC-AM-# Li htwei ht Concrete Assemblies with Adhered Membranes over Concrete Deck New or Existing) LC-M-# Mechanically Fastened Lightweight Concrete Assemblies over Concrete Deck New,Existing,or Recover LC-W-# Induction Welded Lightweight Concrete Assemblies over Concrete Deck New, Existing,or Recover LS-A-# Adhered Lightweight Concrete Assemblies over Steel Deck New or Existing) LS-AM-# I Lightweight Concrete Assemblies with Adhered Membranes over Steel Deck New or Existing) LS-M-# Mechanically Fastened Lightweight Concrete Assemblies over Steel Deck New,Existing,or Recover LS-W-# Induction Welded Lightweight Concrete Assemblies over Steel Deck New,Existing,or Recover R-A-# Adhered Recover Assemblies R-M-# Mechanically Fastened Recover Assemblies R-W-# Induction Welded Recover Assemblies -AM-# Assemblies with Adhered Membranes over Insulated Steel Deck(New,Existing,or Recover 0"4111111111140- 1 Mechanically Fastened Assemblies over Steel Deck New,Existing or Recover S-W-# Induction Welded Assemblies over Steel Deck W-M-## Mechanically Fastened Assemblies over Wood Deck New or Existing) W-W_# I Induction Welded Assemblies over Wood Deck New or Existing) JMC13003.13 FL16758-R13 Page 1 of 46 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK Certificate of Authorization 2gh Dr 17520 Edinburgh urgh Dr Tampa, FL 33647 TECHNICAL SERVICES. LLC. (813)4803421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: JOHNS MANVILLE CORPORATION Issued June 19, 2019 P.O. Box 5108 Denver, CO 80217 (303)978-2478 wwwlm,com Manufacturing Plants: Scottsboro,AL Pawtucket, RI Lancaster,SC Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Single Ply Roof System Code Sections: 1504.3.1, 1504.6, 1504.7, 1507.13, 1515.1.1 , 1515.1.4, 1515.2.4, 1523.1.1, 1523.6.2, 1523.6.5.2.9 Properties: Wind Resistance, Physical Properties, Impact Resistance PRODUCT DESCRIPTION Products Specification Description JM PVC-50 mil ASTM D 4434 Nominal 50-mil thick polyvinyl chloride with DuPont Elvaloy KEE single-ply roof membrane with polyester scrim reinforcement JM PVC-60 mil ASTM D 4434 Nominal 60-mil thick polyvinyl chloride with DuPont Elvaloy KEE single-ply roof membrane with polyester scrim reinforcement JM PVC-80 mil ASTM D 4434 Nominal 80-mil thick polyvinyl chloride with DuPont Elvaloy KEE single-ply roof membrane with polyester scrim reinforcement _ JM PVC Fleece Backed-50 mil ASTM D 4434 Nominal 50-mil thick polyvinyl chloride with DuPont Elvaloy KEE single-ply roof membrane with polyester scrim reinforcement and polyester fleece backing JM PVC Fleece Backed-60 mil ASTM D 4434 Nominal 60-mil thick polyvinyl chloride with DuPont Elvaloy KEE single-ply roof membrane with polyester scrim reinforcement and polyester fleece backing JM PVC Fleece Backed-80 mil ASTM D 4434 Nominal 80-mil thick polyvinyl chloride with DuPont Elvaloy KEE single-ply roof membrane with polyester scrim reinforcement and polyester fleece backing JM PVC SD Plus-50 mil ASTM D 4434 Nominal 50-mil thick polyvinyl chloride single-ply roof membrane with polyester scrim reinforcement _ JM PVC SD Plus-60 mil ASTM D 4434 Nominal 60-mil thick polyvinyl chloride single-ply roof membrane with polyester scrim reinforcement JM PVC SD Plus-80 mil ASTM D 4434 Nominal 80-mil thick polyvinyl chloride single-ply roof membrane with polyester scrim reinforcement JM TPO-45 ASTM D 6878 Nominal 45-mil thick thermoplastic polyolefin,heat-weldable, TAS 131 single-ply roof membrane with polyester scrim reinforcement JM TPO-60 ASTM D 6878 Nominal 60-mil thick thermoplastic polyolefin,heat-weldable, TAS 131 single-ply roof membrane with polyester scrim reinforcement JM TPO-80 ASTM D 6878 Nominal 80-mil thick thermoplastic polyolefin.heat-weldable, TAS 131 single-ply roof membrane with polyester scrim reinforcement JMC13003.13 FL16758-R13 Page 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. { CREEK JOHNS MANVILLE CORPORATION PVC&TPO Single Ply Roofing Systems TECHNICAL SERVICES, LLC APPENDIX A - INSTALLATION INSTALLATION Note-Refer to the APPROVED ASSEMBLIES section of this report for specific installation details of a selected assembly. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail #14 fasteners;Min.3/4-inch penetration through the top rib JM All Purpose Fastener of the steel deck or wood deck; Min. 1-inch penetration into concrete deck JM APB Plates 2-inch diameter;Galvalume steel plate with reinforcing ribs and barbs JM Extra High Load Fastener #21 fastener;Min. 314-inch penetration through the top rib of _ the steel deck, JM Extra High Load Plates 3-inch diameter,Galvalume steel plate with eyehooks JM High Load Plates 2 3/8-inch diameter;Galvalume steel plate with eyehooks JM High Load Plus Plates 2 314-inch diameter; Galvalume steel plate with barbs JM High Load Fastener #15 fastener,Min.3/4-inch penetration through the top rib of the steel deck or wood deck, JM High Load LH Fastener #15 fastener with oversized head,Min.3/4-inch penetration __ through the top rib of the steel deck or wood deck, JM UltraFast Fastener #12 fastener;Min. 3/4-inch penetration through the top rib of the steel deck or wood deck JM UltraFast Plate(Round) 3-inch diameter round,Galvalume steel plate Fasteners,Battens& JM UltraFast Plate(Square) 3-inch square;Galvalume steel plate Plates Min. 1.8-inch galvanized steel tube and coated-steel locking JM Ultra Lok Fastener staple pre-assembled with 2.7-inch diameter Galvalume steel plate JM Polymer Membrane Batten Membrane anchors and plastic strips JM Purlin Fastener Min.3/4-inch penetration through purlin Min. 3-inch diameter,Induction welded in the field of JM PVC RhinoPlate membrane,welds not permitted at lap seams;For use only with bareback membrane Min. 3-inch diameter;Induction welded in the field of JM TPO RhinoPlate membrane,welds not permitted at lap seams;For use only _ with min.60 mil thick bareback membrane Base sheet fastener with 1.75-inch galvanized steel shank OMG CR Base Sheet Fastener coated with CR-10 and integrated 2 75-inch diameter Galvalume plate. Trufast Deep Well Batten Bar Galvalume steel membrane batten with recessed holes Trufast Straight Line Batten Bar Galvalume steel membrane batten for use with Twin-Loc Nail without integrated plate Trufast Twin Loc-Nail Min. 1.4-inch shank;Base sheet fastener with and without integrated 2.7-inch diameter plate. JM MBR Bonding Adhesive Fully adhered at a rate of 1.5-2.0 gal/100 ft2 JM One-Step Foamable Adhesive ICP Adhesives CR-20 OMG OlyBond 500 JM Two Part Urethane Insulation Adhesive Ribbon adhered in 3/4 to 1-inch wide beads Insulation Adhesives Canister or JM Two-Part UTA Canister JM Two Part Urethane Insulation Adhesive or JM Two-Part UTA JM Roofing System Urethane Adhesive JM Urethane Insulation Adhesive Ribbon adhered in 1/2-inch wide beads ASTM D 312,Type IV asphalt Fully adhered within the EVT range at a rate of 25-40 lbs/100 Min.0.5-inch, min. 1.8 pcf(HVHZ)or min. 1.5 pcf(non- Insulation/Cover EPS HVHZ)expanded polystyrene;Adhered boards shall be a Boards _ maximum 4-ft x 4-ft Georgia-Pacific DensDeck Min. 1/4-inch thick JMC13003.13 FL16758-R13 Pae 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK PVC JOHNS MANVILLE CORPORATION &TPO Single Ply Roofing Systems TECHNICAL SERVICES. LLC APPENDIX A- INSTALLATION Component Product i Installation Detail JM ENRGY 3 JM ENRGY 3 C1 JM ENRGY 3 AGF Min 1/2-inch thick,Min. 20 psi; Adhered boards shall be a JM ENRGY 3 CGF maximum 4 ft x 4 h JM ENRGY 3 C1 CGF JM ENRGY 3 FR JM Fesco Board Min.3/44nch thick;Min.20 psi JM Fesco Foam Min. 1.5-inch thick;Min.20 psi; Adhered boards shall be a maximum 4ftx4ft JM Invinsa Roof Board _ JM Invinsa Foam Roof Board 1/4-inch thick;Adhered boards shall be a maximum 4 ft x 4 ft Insulation/Cover JM Invinsa FR Roof Board Boards(Cont'd) JM ProtectoR HD _ 1/2-inch thick;Min.80 psi;Adhered boards shall be a JM ProtectoR HD FR maximum 4 ft x 4 ft JM Retro-Fit Board 1/2-inch thick;Adhered boards shall be a maximum 4 ft x 4 it JM RetroPlus Roof Board JM SECUROCK Glass-Mat Roof Board JM SECUROCK Gypsum-Fiber Roof Min. 1/4-inch thick Board National Gypsum DEXcell Cement Roof Min.7/164nch thick;Adhered boards shall be a maximum 4 Board ft x 4 ft National Gypsum DEXcell Glass Mat Roof Board Min 1l4-inch thick National Gypsum DEXcell FA Glass Mat Roof Board Base Ply and Vapor ADCO Millennium Hurricane Force Ribbon adhered in 3/4 to 1-inch wide beads Barrier Adhesives Membrane Adhesive ASTM D 312,Type IV asphalt Fully adhered within the EVT range at a rate of 2540 lbs/100 ft,For use only with JM PVC Fleece Backed membranes JM PVC Membrane Adhesive(Low VOC) Fully adhered at rate of 50-90 ft'/gal; Applied simultaneously to underside of membrane and substrate PVC Membrane Fully adhered at a rate of 90-130 ft2/gal;Two-side application Adhesives JM PVC Membrane Adhesive(Water required for bareback TPO;Applied only to substrate when Based) used with fleeceback TPO JM Roofing System Urethane Adhesive Ribbon adhered in 1/2 to 3/44nch wide beads _ JM MBR Bonding Adhesive Fully adhered at a rate of 1.5-2.0 gal/100 W ASTM D 312,Type IV asphalt Fully adhered within the EVT range at a rate of 2540 lbs/100 ft;For use only with JM TPO FB 150 and 175 membranes JM Roofing System Urethane Adhesive Ribbon adhered in 3/4 to 1-inch wide beads JM Membrane Bonding Adhesive(TPO& Fully adhered at rate of 50-90 /gal; Applied simultaneously EPDM) to underside of membrane and substrate JM TPO Membrane Adhesive(Low VOC) Fully adhered at rate of 50-90 /gal; Applied simultaneously TPO Membrane to underside of membrane and substrate Adhesives JM LVOC Membrane Adhesive(TPO& Fully adhered at rate of 0.55-0.83 gaill 001112 in two-sided EPDM) application(1.1-1.67 gal/100ft2 total) JM TPO Water Based Membrane Fully adhered at a rate of 0.6-0.8 gal/1 ;Two-side Adhesive application required for bareback TPO;Applied only to substrate when used with fleeceback TPO JM Two Part Urethane Insulation Adhesive Applied in spatter pattern at a rate of 0.32 gal/100112 or 112- Canister inch wide beads _ SA Primer JM SA Primer Low VOC Applied at rate of 0.5 gal/sq. JM DynaBase HW Min.3-inch wide side-laps;Min.6-inch end laps,Torch adhered to primed concrete deck Vapor Barriers JM DynaBase Min 3-inch wide side-laps;Min.6-inch end laps;Applied with hot or cold approved adhesives JM Vapor Barrier SA Self-adhered to primed wood,gypsum or concrete decks Min.3-inch sides laps;Min.64nch end laps JMC13003.13 FL16758-R13 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3 The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein CREEK JOHNS MANVILLE CORPORATION PVC 8 TPO Single Ply Roofing Systems TECHNICAL SERVICES. LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6"'Edition (2017)as evidenced in the referenced documents submitted by the named manufacturer. �� PaY R t111111111111,11, %%%% N 2019.06. 19 • SF �s� No 74021 13:10:53 -04'00' : 3 STATE OF 44/ '••.• G% Zachary R. Priest, P.E. SfON q!r� ` Organa ation No.ANE9641on No. 021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R Priest, P E does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation Zachary R Priest, P.E does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A—Installation (5 pages) 2) APPENDIX B—Nomenclature(4 pages) 3) APPENDIX C—Approved Assemblies for JM TPO Single-Ply Membranes(46 pages) 4) APPENDIX D—Approved Assemblies for JM PVC Single-Ply Membranes (26 pages) JMC13003 13 FL16758-Rl3 Page 6 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein, Docu5 ,t; ■ sscu..o Certificate Of Completion Envelope Id:5BEC233A788C4CD081E05E1077E7E8B6 Status:Completed Subject:Please DocuSign:3939 St.Lucie Blvd,Ft.Pierce FSC DSIGNED.pdf Source Envelope: Document Pages. 1 Signatures: 1 Envelope Originator: Certificate Pages:2 Initials:0 Jorge F.Gonzalez AutoNav:Enabled 10735 SW 216 St Envelopeld Stamping:Enabled Unit#416 Time Zone:(UTC-08:00)Pacific Time(US&Canada) Miami,FL 33170 jgonzalez@floridatec.net IP Address 98.211.218.250 Record Tracking Status:Original Holder:Jorge F Gonzalez Location:DocuSign 12/10/2019 12:48:05 PM jgonzalez@floridatec.net Signer Events Signature Timestamp Jorge F.Gonzalez Ej�ENCD20090]45 -L.._ Sent: 12/10/2019 12:48:15 PM jgonzalez@floridatec.net �°�"7�'�'7 Viewed:12/10/2019 12:48:21 PM Engineer Signed:12/10/2019 12:48:50 PM Florida TEC Freeform Signing Security Level:Email,Account Authentication Signature Adoption:Pre-selected Style (None) Using IP Address:98.211.218.250 Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Elthon COPIED Sent:12/10/2019 12:48:51 PM elthon@floridatec.net Security Level:Email,Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign Michael Sent: 12/10/2019 12:48:51 PM mwinant@tectaamerica.com CO PI E D J President Tecta America Southeast LLC Security Level:Email,Account Authentication (None) Electronic Record and Signature Disclosure: Not Offered via DocuSign Witness Events Signature Timestamp v 12/10/2019 Google Maps Go gle Maps 1 � 7 r y f le - �. t IL Imagery 02019 Google,Map data @2019,Map data 02019 10 ft haps://www.google.com/maps/place/Coca-Cola+Bottling+Col@27.4840858,-80.3642066,53a,35y,180.14h.45.07t/data=!3m 1!1 e3!4m6!3m5!1 sOx88def... 1/1