Loading...
HomeMy WebLinkAboutProduct Approval (3) FLQSXkk0EIPAMWJW OP Business Regulation - BCIS Home i Log In I user Registration I Hot Topics ( Submit Surcharge Stats&Facts Publications j Contact Us I BCIS Site Map Links Search a = Product Approval db r Ir USER:Public User 3Fg Product Approval Menu>Product or Apylicatlon Search>Aoolication List>Application Detail • FL# FL6332-R8 Application Type Revision RECEIVED Code Version 2017 Application Status Approved D F r 12 9 j 9 Comments ST. L+asi�.,C.Qunty, Permitting Archived Q Product Manufacturer ICP Adhesives&Sealants,Inc. Address/Phone/Email 12505 NW 44th Street Coral Springs, FL 33065 (888)774-1419 Ext201 rylipelkonen@icpadhesives.com ile copy Authorized Signature Riku Ylipelkonen rylipelkonen@icpadhesives.com I REVIEWED FOR Technical Representative CODE C0 PLIA�CE i Address/Phone/Email C1 �® Quality Assurance Representative STa LUCIE COUNTY Address/Phone/Email BOCC Category Roofing Subcategory Roof Tile Adhesives Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer G Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/07/2021 Validated By John W. Knezevich, PE O Validation Checklist-Hardcopy Received Certificate of Independence FL6332 R8 COI 2017 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year SSTD 11 1997 Equivalence'of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/12/2017 Date Validated 10/14/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 6332.1 ICP Adhesives Polyset AH-160 Dual component expanding polyurethane roof tile adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL6332 R8 II 2017 10 FINAL ER ICP AH160 FL6332- Approved for use outside HVHZ:Yes R8.pdf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +n/a/-178 Created by Independent Third Party:Yes Other: 1.)The design pressure limitation in this application Evaluation Reports refers to hip and ridge tiles in one configuration. Refer to Table FL6332 R8 AE 2017 10 FINAL ER ICP AH160 FL6332- 2 of ER for all hip and ridge tile limitations. 2.) Field tiles are 118.pdf designed based on overturning moment resistance. Refer to Created by Independent Third Party:Yes Table 1 of ER for field tile limitations. 3.) Refer to ER Sections 5 for other Limitations of Use. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® ec8k M Credit Card Safe EXTERIOR RESEARCH&DESIGN, I.I.C. C)o Certificate of Authorization##9503 TRINITY ERD 353 CHRISTIAN STREET, UNIT 13 OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-118 12505 NW 44th Street FL6332-118 Coral Springs, FL 33065 Date of Issuance:08/08/2008 (888)774-1419 Revision 8:10/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition(2017) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset®AH-160 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation,Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: i,MJ Robert J.M. Nieminen,P.E. +,D'•.�,= 'trr'• ;' The facsimile seal appearing was authorized by Robert Florida Registration No.59166, Florida DCA ANE1983 ;�ss� ati Nieminen,P.E.on o/1z/zo17. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert,Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinitvl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. QOTRINITYIERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Roof Tile Adhesives Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the 6th Edition (2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Sections Property Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ERD(TST 6049) Static Uplift—SSTD 11 P39740.02.12 02/20/2012 ERD(TST 6049) Static Uplift—SSTD 11 P39740.11.13-R1 01/02/2015 ICC-ES(EVL2396) 2012 IBC Compliance ESR-1709 12/01/2016 Miami-Dade(CER 1592) HVHZ compliance 17-0322.03 04/27/2017 PRI(TST 5878) Static Uplift—SSTD 11 ECM-001-02-01 09/21/2001 PRI(TST 5878) Static Uplift—SSTD 11 PFI-006-02-01 05/09/2005 PRI(TST 5878) Static Uplift—SSTD 11 PFI-006-02-02 05/09/2005 PRI.(TST 5878) Static Uplift—SSTD 11 PFI-007-02-01 10/11/2005 PRI(TST 5878) Static Uplift—SSTD 11 PFI-008-02-04 02/21/2006 PRI(TST 5878) Static Uplift—SSTD 11 PFI-009-02-03 02/21/2006 PRI(TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI(TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI(TST 5878) Static Uplift—SSTD 11 PFPI-010-02-01 12/07/2006 PRI(TST 5878) Static Uplift—SSTD 11 PFPI-011-02-01 12/07/2006 PRI(TST 5878) Static Uplift—SSTD 11 PFPI-012-02-01 12/07/2006 PRI(TST 5878) Static Uplift—SSTD 11 PFPI-013-02-01 12/07/2006 PRI(TST 5878) Static Uplift—SSTD 11 PFPI-014-02-01 12/07/2006 PRI(TST 5878) Static Uplift—SSTD 11 ECM-003-02-01 06/13/2008 PRI(TST 5878) Static Uplift—SSTD 11 ECM-004-02-01 06/13/2008 PRI(TST 5878) Static Uplift—SSTD 11 ECM-005-02-01 06/13/2008 PRI(TST 5878) Static Uplift—SSTD 11 ECM-006-02-01 06/13/2008 PRI(TST 5878) Static Uplift—SSTD 11 ECM-007-02-01 06/13/2008 PRI(TST 5878) Static Uplift—SSTD 11 ECM-008-02-01 06/13/2008 UL LLC(QUA 9625) Quality Assurance Service Confirmation Exp.06/05/2018 4. PRODUCT DESCRIPTION: 4.1 ICP Adhesives Polyset®AH-160 is a two-component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders(ICP Adhesives ProPacko 30&100). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E.are,in anyway,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Exterior Research and Design,I.I.C. Evaluation Report 02768.03.06-R8 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-118 ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017 Page 2 of 9 QoTskINITYIERD 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset®AH-160 can be used with flat,low and high profile tiles or any rigid,discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local-level by the Authority Having Jurisdiction. 5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local-level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset®AH-160. 5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH-160 are limited to projects having an Aerodynamic Uplift Moment (Ma), determined in accordance with FBC 1609.5.3 or Tables 2A and 26 of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 1: FIELD TILES IN ICP ADHESIVES POLYSETO AH-160 ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA 2 TO 1 MARGIN OF SAFETYALREADYAPPUED FOR INDEPENDENT SINGLE OR CONTINUOUS PADDY)PLACEMENT 4 TO 1 MARGIN OFSAFETYALREADYAPPUED FOR INTERDEPENDENT TWO PADDY)PLACEMENT Tile(FBC 1609.5.3) Allowable Adhesive Paddy Placement Overturning Type Profile Moment(ft-Ibf) Independent;Single Paddy,Medium(2x7-inch,-30 gram) 60 Concrete Clay Flat Independent;Single Paddy,Large(2x10-inch,-45 gram) 112 Interdependent;Two Paddy(4x4-inch on underlayment,2x4-inch at tile overlap) 54 Independent;Single Paddy,Medium(2x7-inch,-30 gram) 39 Concrete te Medium Clay Low/ Independent;Single Paddy,Large(2x10-inch,-54 gram) 67 Interdependent;Two Paddy(4x4-inch on underlayment,2x4-inch at tile overlap) 58 Clay High Independent;Single Paddy,Large(2x10-inch,-45 gram) 134 Independent;Single Paddy,Medium(2x7-inch,-30 gram) 65 Concrete Clay High Independent;Single Paddy,Large(2x10-inch,-63 gram) 109 Interdependent;Two Paddy(4x4-inch on underlayment,2x4-inch at tile overlap) 40 Clay Barrel 2x10-inch x^35 gram for pans;2 @ 1x10-inch x-17 gram for cap 147 Concrete Barrel 2x10-inch x-35 gram for pans;2 @ WO-inch x-17 gram for cap 107 Cap atop 2x Clay stringer Independent:Continuous Paddy(^'34 gram/ft) 135 Cap atop 2x Concrete stringer Independent:Continuous Paddy(^'34 gram/ft) 116 ClayCap atop 2x Interdependent: 105 stringer Head:One(1)#10 x 2Yz'screw;Overlap:1 x 6 inch(-10.5 gram) Cap atop 2x Interdependent: Concrete 76 stringer Head:One(1)#10 x 2W'screw;Overlap:1 x 6 inch(-10.5 gram) 5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April 2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local-level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Polyset®AH-160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent two-paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the'allowable overturning moment'. Exterior Research and Design,LLC. Evaluation Report 02768.03.06-R8 Certificate of Authorization#9503 6'EDmON(2017)FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017 Page 3 of 9 1"TINITY I ERD 5.7 Hip and ridge tiles using ICP Adhesives Polyset®AH-160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. TABLE 2:Hip&RIDGE TILES IN ICP ADHESIVES POLysET®AH-160 ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA 2 TO I MARGIN OF SAFETYALREADYAPPLIED FOR INDEPENDENT(CONTINUOUS PADDY)PLACEMENT 4 TO I MARGIN OF SAFETYALREADYAPPLIED FOR INTERDEPENDENT PLACEMENT Allowable Tile Substrate Attachment Method Design Pressure (psf) Clay 2x PT ridge board Independent:Continuous Paddy("34 gram/ft) 116 Concrete 2x PT ridge board Independent:Continuous Paddy(—34 gram/ft) 107 Clay 2x PT ridge board Interdependent: Head:One(1)#10 x 2%"screw; 90 Overlap:1 x 6 inch(-10.5 gram) Concrete 2x PT ridge board Interdependent:Head:One(1)#10 x 2%"screw; 56 Overlap:1 x 6 inch(-10.5 gram) Clay or Hip&Ridge Channel Metal(FL5374): Independent:Continuous Paddy("34 gram/ft) 169 Concrete galvanized only Clay or Trim Lock TM(FL5374): aluminum, Concrete galvanized,Galvalume0 or stainless steel Independent:Continuous Paddy(^34 gram/ft) 173 Clay or Trim LockT"Plus(FL5374): aluminum, Concrete galvanized,Galvalume11 or stainless steel Independent:Continuous Paddy(" 34 gram/ft} 178 PClay Top Notch(FL8095) Independent:Continuous Paddy(�32 gram/ft) 125 oncrete Top Notch(FL8095) Independent:Continuous Paddy(" 32 gram/ft) 146 6. INSTALLATION: 6.1 ICP Adhesives Polyset® AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section 5. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012(04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants,Inc. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Tomball,TX 9. QUALITY ASSURANCE ENTITY: UL, LLC.—QUA9625;(847)664-3623;LeAnna.Gradecki@ul.com Exterior Research and Design,I.I.C. Evaluation Report 02768.03.06-R8 Certificate of Authorization#9503 61"EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-118 ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017 Page 4 of 9 TOR INIIY`ERD 10. PADDY PLACEMENT DETAILS(FROM ICP ADHESIVES AND SEALANTS,INC.PUBLISHED LITERATURE): 10.1 Independent,Medium Paddy: Nail through plastic cement Paddy(Beneath Tile) (when required) Nail through plastic cement (when required) Underlayment Paddy(BeneathTlle) 1.: Underlayment ,2 in. Battens optional .�.� .� Eave Course W Battens optional o,r� o 10 in. �`.t; 10 in. 2 in. Fascia / 2 in Eave Closure Eave Closure Eave Course Fascia Flat/Low Profile Tile Medium Profile Tile Nail through plastic ce (when required) Paddy(Beneath Tile) Underlayment o 2 in. Battens optional V Eave Course Fascia Weephole 10 in. 2 in. Eave closure Drip edge High Profile Tile Exterior Research and Design,U.C. Evaluation Report 02768.03.06-118 Certificate of Authorization#9503 6TH EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017 Page 5 of 9 f . QI TRINITY I ERD 10.2 Independent,Large Paddy: Nail through plastic cement Paddy(Beneath Tile) (when required) Nail through plastic cement (when required) Underlayment ° Paddy(a e neath Tile) 1 � Underlayment � I 10 in. Battens optional - 10 in.x P ° ` : 22 in.w� Eave Course Battens optional O M o` y 10 in. - 7 0 in. 2 in, / Fascia / 2 in Eave Closure Eave Closure Eave Course Fascia Flat/Low Profile Tile Medium Profile Tile Nail through plasticce (when required) Paddy(Beneath Tile) Underlayment o 10 in.x � 2 in.wide Battens o `�- optional Eave Course " Fascia Weephole 10 in. tin. Eave closure Drip edge High Profile Tile Exterior Research and Design,LLC. Evaluation Report 02768.03.06-R8 Certificate o/Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-118 ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017 Page 6 of 9 QOTRINi-rYIERD 10.3 Interdependent,Two PaddV: Nail through plastic cement Paddy(between tiles) (when required) Nail through plastic cement Single paddy under tile (when required) Battens optional ° Paddy(between tiles) ° Paddy(under tile) f Single paddy Battens Paddy(under tile) / on top oftile ,% optional r �. � 4 r by x 4 in. Single paddy .� Single padd \ 1 under tiles �.on top of file Singlepaddy `� / �4x4in. on underlayment �F 2 x 4 in. ` `�' / 2 x 4 in. -\ 7 Single paddy on underlayment 0 70 in. 3 / Fascia 10 in. �`� � Z in. 2 in. Eave Closure Eave Closure Eave Course Fascia Flat/Low Profile Tile Medium Profile Tile Nailthroughplasticce Single paddy under tile (when required) Paddy(between tiles) Battens optional o Paddy(under tile) Single paddy on underlayment 4x4in. Single 2 x 4in. paddyon top of tile �. Eave Course "� Fascia Weephole 70 in. in. Eave closure Drip edge High Profile Tile Exterior Research and Design,LLC. Evaluation Report 02768.03.06-R8 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017 Page 7 of 9 QOTRINITYIERD 10.4 Two Piece Barrel(Cap&Pan)Tile: 1)Place enough adhesive to achieve 6S to 70 sq.in. Steep pitch applications In contact with the pan tile. when required) 2)Turn Covers upside down.Place adhesive 1121n.to 1 inch in from outside edge of cover tile. Install cover tile. Ensure 20 to 25 sq.In.contactarea on each side of cover tile. Undedaymeht Sheathing Eave closure (motar shown) Weephole Fascia Board Remove top portion of the eave course cover tile.Abut to second course of pan tiles.Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel-High Proffldi ile 10.5 Hip and Ridge(independent placement): 2" r r r A bead of tCP PolyseMAH-160 may be applied above the field To attach hipf6d2p tiles,a bead of ICP PotysetfiAH-160 may To aaacb hiptid;e dam a bead of ICP PoIrwMAH-160 roof ale adhemm may tilt surface oa both sides of the hiplfte board or gal inized be applied doum the center of the Wridge board or gahinized be crypt ea aloyr the Em trngh of the nle extdmg L ncba eacl�g L Indus oa metal frame to provide%veathetblockiue. Mane. �� of rk. Exterior Research and Design,I.I.C. Evaluation Report 02768.03.06-R8 Certificate of Authorization#9503 6t"EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-R8. ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017 Page 8 of 9 Q0 TRINITY ERD 10.6 Hip and Ridge(interdependent placement): 1"X 6" Bead of ICP PolysetOAH-160 roof tile adhesive #10 x 2-1/2"Screw Code Approved --: Fastener Adhere starter tile with a 2"x 7" Paddy placed 3" down from head of tile -END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report 02768.03.06-118 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL6332-118 ICP Adhesives Polyset®AH-160;(888)774-1419 Revision 8:10/12/2017 Page 9 of 9