HomeMy WebLinkAboutProduct Approvals NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Onduline North America, Inc. 4900 Ondura Drive Fredericksburg, VA 22407 Evaluation Report O39230.10.11-R4 FL4081-R5 (NON-HVHZ) Date of Issuance: 10/27/2011 Revision 4: 08/09/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words “NEMO|etc. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 22-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 08/09/2019. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. © 2018, NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL4081-R5 (NON-HVHZ) Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Revision 4: 08/09/2019 Page 2 of 4 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Products Introduced as the Result of New Technology Compliance Statement: Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems, as produced by Onduline North America, Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3 Wind UL1897 2012 1504.3 Wind FM 4474 2011 1504.6 Physical Properties ASTM G154 2006 3. REFERENCES: Entity Examination Reference Date FET (TST 1654) Wind T196-19 06/19/2019 ICC-ES (EVL 2396) 2015 IBC / IRC Compliance ESR-1957 06/01/2019 ITS (TST 1509) Wind 50484-C7-706400 10/11/1990 ITS (TST 1509) Physical properties 50484-C7-706400 10/11/1990 ITS (TST 1509) Wind 3181925COQ-003 08/26/2009 QAI (TST 9808) Physical properties & wind RJ3539-1 06/01/2015 QAI (QUA 7628) Quality Assurance Service Confirmation 07/03/2019 4. PRODUCT DESCRIPTION: 4.1 The following Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems are mechanically attached to an approved substrate, as outlined in the Limitations / Conditions of Use herein. 4.1.1 Ondura® Corrugated Asphalt Roofing Sheet are corrugated sheeting made from mineral and organic fibers impregnated with asphalt. Sheets are nominal 0.123-inch thick and measure nominal 48 x 79 inches with a finished weight of 0.68 lb/ft2. Sheets have continuous 1.375-inch deep corrugations spaced 4-inch o.c. along the sheet length. NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL4081-R5 (NON-HVHZ) Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Revision 4: 08/09/2019 Page 3 of 4 4.1.2 Ondura® Corrugated Asphalt Roofing Tile are the same as Ondura® Corrugated Asphalt Roofing Sheet, but 19.75- inch long. 4.1.3 Onduvilla® Corrugated Asphalt Roofing Tiles are corrugated sheeting made from mineral and organic fibers impregnated with asphalt. Sheets are nominal 0.113-inch thick and measure nominal 42 x 15.75 inches with a finished weight of 0.60 lb/ft2. Sheets have continuous 1.5-inch deep corrugations spaced 7.6-inch o.c. along the sheet length. NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL4081-R5 (NON-HVHZ) Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Revision 4: 08/09/2019 Page 4 of 4 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This evaluation report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 The minimum roof slope per manufacturer’s installation instructions is 3:12 (14°). 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 Appendix 1 outlines attachment requirements for design wind pressure resistance. “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind pressures. The MDP for the selected assembly shall meet or exceed the design wind pressure requirements for the project for each pressure zone of the roof. 5.6.1 Reference to “OK” indicates the system performance exceeds requirements for that pressure zone. Reference to “NO” indicates additional testing or rational analysis by a qualified design professional is required to address that particular pressure zone. 5.7 For existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. A qualified design professional shall review the data for comparison to the minimum requirements for the system. 5.8 Perimeter and ridge details shall be designed and installed to resist the wind load requirements of FBC Chapter 16. 5.9 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems shall be installed in accordance with Onduline North America, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. System components, including the sheets, tiles and fasteners shall be as supplied by Onduline North America, Inc. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: ✓ Ondura® Corrugated Asphalt Roofing Sheet & Ondura® Corrugated Asphalt Roofing Tile: Fredricksburg, VA ✓ Onduvilla® Corrugated Asphalt Roofing Tiles: Gallarta Vizcaya, Spain 9. QUALITY ASSURANCE ENTITY: Quality Auditing Institute, Ltd. – QUA7628; (604) 527-8378 - THE 22-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 1 of 22 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR DESIGN WIND PRESSURE RESISTANCE: TABLE SYSTEM PRODUCT FASTENING MAX DESIGN PRESSURE (PSF) PAGE A-1 1 Ondura® Corrugated Asphalt Roofing Sheet On every ridge (4-inch o.c.) and 24-inch o.c. vertically -30.0 2-4 A-2 2 Ondura® Corrugated Asphalt Roofing Sheet On every ridge (4-inch o.c.) and 12-inch o.c. vertically -60.0 5-7 B-1 3 Ondura® Corrugated Asphalt Roofing Tile Valley & Crown -47.0 8-10 B-2 4 Ondura® Corrugated Asphalt Roofing Tile All Crowns -54.5 11-13 C-1 5 Onduvilla®Corrugated Asphalt Roofing Tile All Crowns -35.0 14-16 C-2 6 Onduvilla® Corrugated Asphalt Roofing Tile Nails at head and screws at all crowns -86.0 17-19 C-3 7 Onduvilla® Corrugated Asphalt Roofing Tile Screws at and between all crowns -108.5 20-22 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted herein, fire barrier and/or underlayment materials may be any that meet FBC Table 1507.1.1, Onduline North America, Inc. minimum requirements, the QA requirements of F.A.C. Rule 61G20-3 and FBC 1505 when installed with the roof cover. 3. “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 4. Tables are based on roof cladding design wind pressure requirements for gabled/hipped roofs in accordance with ASCE 7-10, multiplied by 0.6 (Pasd). 5. Tables are limited to projects having gable or hip roofs with a mean roof height between 0 and 60 feet, slopes between 14° and 45° (3:12 to 12:12 pitch), enclosed buildings (Internal Pressure Coefficient, GCPi = + 0.18), no load combinations (Kd = 1) and site conditions and location of the structure do not meet all conditions specified in Section 26.8.1 of ASCE 7-10 (Kzt = 1.0). Analysis for buildings falling outside these constraints shall be on a project-by-project basis by a Florida Registered PE. 6. Reference to “OK” indicates the system performance exceeds project requirements for that pressure zone. Reference to “NO” indicates additional testing or rational analysis by a Florida Registered PE is required to address that particular pressure zone. 7. The dimension of Zones 2 and 3 (perimeters and corners) shall be defined as 10% of the least horizontal plan -view dimension or 40% of the mean roof height, whichever is smaller, but not less than either 4% of the least horizontal plan-view dimension or 3 feet, as outlined in Figures 30.4-2B and 30.4-2C of ASCE 7-10. 8. For existing decks, fasteners shall be tested in the existing deck for withdrawal resistance in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. A qualified design professional shall review the data for comparison to the minimum requirements for the system. 9. Fasteners shall be as follows: Fastener Description Ondura® Nails Minimum 0.135-inch diameter, corrosion-resistant, ring-shank nails having a 7/16-inch diameter head with a 1/8-inch thick x 5/8-inch diameter EPDM rubber washer integral below the nail head, of sufficient length to penetrate the underside of the roof sheathing by not less than ¾-inch. roofing nails Minimum 11 ga. (0.125-inch diameter) x minimum 1¾-inch long, corrosion-resistant, ring-shank roofing nails having a minimum 0.410-inch diameter head, of sufficient length to penetrate the underside of the roof sheathing by not less than ¾-inch. Onduvilla® Screws Minimum #10-15 x 3-inch long, corrosion-resistant, hex head, “A” point with 5/8-inch diameter steel & EPDM sealing washer, of sufficient length to penetrate the underside of the roof sheathing by not less than ¾-inch. NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 2 of 22 TABLE A-1: SYSTEM 1: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 24-INCH ATTACHMENT) WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF), OR RECOVER (OVER EXISTING ASPHALT SHINGLES OR WOOD SHAKE/SHINGLE) System No. Deck (See Note 1) Fire Barrier / Underlay Sheet Attachment MDP (psf) Fasteners Fastener Placement 1. Min. 7/16” APA rated OSB or min. 15/32” APA rated plywood See Note 2 Ondura® Nails On every ridge (4-inch o.c.) and 24-inch o.c. vertically up the sheet. -30.0 Note: Fastening locations marked with an ‘X’ are not fastened until lapped by adjoining sheet; minimum 7-inch head-lap and minimum one-corrugation side-lap. TABLE A-1A: SYSTEM NO. 1: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 24 INCH ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK NO NO NO 2 OK OK NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK NO NO NO NO 2 OK NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK NO NO NO NO 2 OK NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE A-1B: SYSTEM NO. 1: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 24 INCH ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK NO NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang OK NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK NO NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK NO NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 3 of 22 TABLE A-1C: SYSTEM NO. 1: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 24 INCH ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK NO NO NO NO 2 OK NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK NO NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK NO NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE A-1D: SYSTEM NO. 1: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 24 INCH ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK NO NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK NO NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK OK NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK NO NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK NO NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 4 of 22 TABLE A-1E: SYSTEM NO. 1: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 24 INCH ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK NO NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK NO NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK NO NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK NO NO NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK NO NO NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE A-1F: SYSTEM NO. 1: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 24 INCH ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK OK NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK NO NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK NO NO NO NO NO NO NO 2 & 3 OK NO NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK NO NO NO NO NO NO NO 2 & 3 NO NO NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK NO NO NO NO NO NO NO NO 2 & 3 NO NO NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK NO NO NO NO NO NO NO NO 2 & 3 NO NO NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 5 of 22 TABLE A-2: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 12-INCH ATTACHMENT) WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF), OR RECOVER (OVER EXISTING ASPHALT SHINGLES OR WOOD SHAKE/SHINGLE) System No. Deck (See Note 1) Fire Barrier / Underlay Sheet Attachment MDP (psf) Fasteners Fastener Placement 2. Min. 7/16” APA rated OSB or min. 15/32” APA rated plywood See Note 2 Ondura® Nails On every ridge (4-inch o.c.) and 12-inch o.c. vertically up the sheet. -60.0 Note: Fastening locations marked with an ‘X’ are not fastened until lapped by adjoining sheet; minimum 7-inch head-lap and minimum one-corrugation side-lap. TABLE A-2A: SYSTEM NO. 2: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 12 INCH ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK OK NO NO NO NO 2 Overhang OK OK OK OK OK OK NO NO NO 3 Overhang OK OK OK NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK OK NO NO NO 3 Overhang OK OK NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang OK NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang OK NO NO NO NO NO NO NO NO TABLE A-2B: SYSTEM NO. 2: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 12 INCH ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 6 of 22 TABLE A-2C: SYSTEM NO. 2: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 12 INCH ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang OK NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK OK NO NO NO NO 3 OK OK NO NO NO NO NO NO NO 2 Overhang OK OK OK OK NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK OK NO NO NO NO 3 OK OK NO NO NO NO NO NO NO 2 Overhang OK OK OK OK NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK NO NO NO NO NO 3 OK NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK OK NO NO NO NO NO 3 OK NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE A-2D: SYSTEM NO. 2: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 12 INCH ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 7 of 22 TABLE A-2E: SYSTEM NO. 2: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 12 INCH ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK OK NO NO NO NO 3 OK OK NO NO NO NO NO NO NO 2 Overhang OK OK OK OK NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK NO NO NO NO NO 3 OK NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK OK NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK OK NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE A-2F: SYSTEM NO. 2: ONDURA® CORRUGATED ASPHALT ROOFING SHEET (4 X 12 INCH ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 8 of 22 TABLE B-1: ONDURA® CORRUGATED ASPHALT ROOFING TILE (VALLEY & CROWN ATTACHMENT) WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF), OR RECOVER (OVER EXISTING ASPHALT SHINGLES OR WOOD SHAKE/SHINGLE) System No. Deck (See Note 1) Fire Barrier / Underlay Tile Attachment MDP (psf) Fasteners Fastener Placement 3. Min. 15/32” APA rated plywood See Note 2 Valleys: corrosion- resistant roofing nails Crowns: Ondura® Nails -47.0 Note: For System 3, fastening locations marked with a ‘dot’ are fastened in the corrugation valley prior to placement of the overlapping tile; minimum 5¾-inch head-lap and minimum one-corrugation side-lap. TABLE B-1A: SYSTEM NO. 3: ONDURA® CORRUGATED ASPHALT ROOFING TILE (VALLEY & CROWN ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK OK NO NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK OK NO NO NO NO 3 OK OK NO NO NO NO NO NO NO 2 Overhang OK OK OK OK NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK NO NO NO NO NO 3 OK NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE B-1B: SYSTEM NO. 3: ONDURA® CORRUGATED ASPHALT ROOFING TILE (VALLEY & CROWN ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 9 of 22 TABLE B-1C: SYSTEM NO. 3: ONDURA® CORRUGATED ASPHALT ROOFING TILE (VALLEY & CROWN ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK NO NO NO NO NO 3 OK NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK OK NO NO NO NO NO 3 OK NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK NO NO NO 2 OK OK NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE B-1D: SYSTEM NO. 3: ONDURA® CORRUGATED ASPHALT ROOFING TILE (VALLEY & CROWN ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang OK OK NO NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 10 of 22 TABLE B-1E: SYSTEM NO. 3: ONDURA® CORRUGATED ASPHALT ROOFING TILE (VALLEY & CROWN ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK NO NO NO 2 OK OK NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK NO NO NO 2 OK OK NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK NO NO NO NO 2 OK NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK NO NO NO NO 2 OK NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE B-1F: SYSTEM NO. 1: SYSTEM NO. 3: ONDURA® CORRUGATED ASPHALT ROOFING TILE (VALLEY & CROWN ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK NO NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang OK NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK NO NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang OK NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK NO NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK NO NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 11 of 22 TABLE B-2: ONDURA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF), OR RECOVER (OVER EXISTING ASPHALT SHINGLES OR WOOD SHAKE/SHINGLE) System No. Deck (See Note 1) Fire Barrier / Underlay Tile Attachment MDP (psf) Fasteners Fastener Placement 4. Min. 15/32” APA rated plywood See Note 2 Ondura® Nails -54.5 Note: For System 4, fastening locations are at the corrugation crown after placement of the overlapping tile; minimum 5¾- inch head-lap and minimum one-corrugation side-lap. TABLE B-2A: SYSTEM NO. 4: ONDURA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK OK NO NO NO 3 Overhang OK OK NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang OK NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK OK NO NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE B-2B: SYSTEM NO. 4: ONDURA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 12 of 22 TABLE B-2C: SYSTEM NO. 4: ONDURA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK OK NO NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK OK NO NO NO NO 3 OK OK NO NO NO NO NO NO NO 2 Overhang OK OK OK OK NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK NO NO NO NO NO 3 OK NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK OK NO NO NO NO NO 3 OK NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK OK NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE B-2D: SYSTEM NO. 4: ONDURA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 13 of 22 TABLE B-2E: SYSTEM NO. 4: ONDURA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK OK NO NO NO NO NO 3 OK NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK OK NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK NO NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE B-2F: SYSTEM NO. 4: ONDURA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK OK NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK NO NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 14 of 22 TABLE C-1: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF), OR RECOVER (OVER EXISTING ASPHALT SHINGLES OR WOOD SHAKE/SHINGLE) System No. Deck (See Note 1) Fire Barrier / Underlay Tile Attachment MDP (psf) Fasteners Fastener Placement 5. Min. 15/32” APA rated plywood or OSB See Note 2 Onduvilla® Screws -35.0 Note: For System 5, fastening locations are at the corrugation crown after placement of the overlapping tile; minimum 3.5-inch head-lap and minimum one-corrugation side-lap. TABLE C-1A: SYSTEM NO. 5: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK OK NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK OK NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK OK NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK NO NO 2 OK OK OK NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK NO NO NO 2 OK OK NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE C-1B: SYSTEM NO. 5: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE B FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK NO NO 2 & 3 OK OK OK OK OK OK NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK OK NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK OK NO NO NO NO 2 & 3 Overhang OK OK NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang OK OK NO NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 15 of 22 TABLE C-1C: SYSTEM NO. 5: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK NO NO NO 2 OK OK NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang OK NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK NO NO NO 2 OK OK NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK NO NO NO NO 2 OK NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE C-1D: SYSTEM NO. 5: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE C FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang OK OK NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK NO NO NO NO 2 & 3 OK OK OK OK NO NO NO NO NO 2 & 3 Overhang OK NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK NO NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK NO NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK NO NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 16 of 22 TABLE C-1E: SYSTEM NO. 5: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK NO NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK NO NO NO NO NO NO 2 NO NO NO NO NO NO NO NO NO 3 NO NO NO NO NO NO NO NO NO 2 Overhang NO NO NO NO NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE C-1F: SYSTEM NO. 5: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (CROWN ONLY ATTACHMENT) EXPOSURE D FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK NO NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK NO NO NO NO NO 2 & 3 OK OK OK NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK OK NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK OK NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK NO NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK NO NO NO NO NO NO 2 & 3 OK NO NO NO NO NO NO NO NO 2 & 3 Overhang NO NO NO NO NO NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 17 of 22 TABLE C-2: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (NAILS AT HEAD & SCREWS AT CROWN) WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF), OR RECOVER (OVER EXISTING ASPHALT SHINGLES OR WOOD SHAKE/SHINGLE) System No. Deck (See Note 1) Fire Barrier / Underlay Tile Attachment MDP (psf) Fasteners Fastener Placement 6. Min. 15/32” APA rated plywood See Note 2 At tile head: 11 ga. x min. 1¾-inch long rink shank roofing nails. At crowns: Onduvilla® Screws -86.0 Note: For System 6, fastening locations are nails at the head at the valleys between the crowns, prior to placement of the overlapping tile, and screws at the corrugation crowns after placement of the overlapping tile. Nails at the head are doubled at the outermost valleys. Minimum 3.5-inch head-lap and minimum one-corrugation side-lap. TABLE C-2A: SYSTEM NO. 6: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (NAILS AT HEAD & SCREWS AT CROWN) EXPOSURE B FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK OK 3 OK OK OK OK OK OK OK NO NO 2 Overhang OK OK OK OK OK OK OK OK NO 3 Overhang OK OK OK OK OK NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK OK OK NO NO 2 Overhang OK OK OK OK OK OK OK OK NO 3 Overhang OK OK OK OK OK NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK OK NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK OK NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK OK NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK OK NO NO NO NO NO TABLE C-2B: SYSTEM NO. 6: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (NAILS AT HEAD & SCREWS AT CROWN) EXPOSURE B FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 18 of 22 TABLE C-2C: SYSTEM NO. 6: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (NAILS AT HEAD & SCREWS AT CROWN) EXPOSURE C FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK OK NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK OK NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK NO NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK OK NO NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK OK NO NO NO 3 Overhang OK OK OK NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK OK NO NO NO 3 Overhang OK OK NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang OK OK NO NO NO NO NO NO NO TABLE C-2D: SYSTEM NO. 6: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (NAILS AT HEAD & SCREWS AT CROWN) EXPOSURE C FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO 15 < h < 20 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 20 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 19 of 22 TABLE C-2E: SYSTEM NO. 6: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (NAILS AT HEAD & SCREWS AT CROWN) EXPOSURE D FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK OK NO NO NO 3 Overhang OK OK OK NO NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK OK NO NO NO 3 Overhang OK OK NO NO NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang OK NO NO NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang OK NO NO NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK OK NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK NO 2 OK OK OK OK OK OK NO NO NO 3 OK OK OK NO NO NO NO NO NO 2 Overhang OK OK OK OK NO NO NO NO NO 3 Overhang NO NO NO NO NO NO NO NO NO TABLE C-2F: SYSTEM NO. 6: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (NAILS AT HEAD & SCREWS AT CROWN) EXPOSURE D FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 20 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK NO 2 & 3 OK OK OK OK OK OK OK NO NO 2 & 3 Overhang OK OK OK OK OK NO NO NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 20 of 22 TABLE C-3: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (SCREWS AT AND BETWEEN ALL CROWNS) WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF), OR RECOVER (OVER EXISTING ASPHALT SHINGLES OR WOOD SHAKE/SHINGLE) System No. Deck (See Note 1) Fire Barrier / Underlay Tile Attachment MDP (psf) Fasteners Fastener Placement 1. Min. 15/32” APA rated plywood See Note 2 Onduvilla® Screws -108.5 Note: For System 7, fastening locations are screws at and between the corrugation crowns after placement of the overlapping tile. Minimum 3.5-inch head-lap and minimum one-corrugation side-lap. TABLE C-3A: SYSTEM NO. 7: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (SCREWS AT AND BETWEEN ALL CROWNS) EXPOSURE B FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK OK 3 OK OK OK OK OK OK OK OK NO 2 Overhang OK OK OK OK OK OK OK OK OK 3 Overhang OK OK OK OK OK OK OK NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK OK 3 OK OK OK OK OK OK OK OK NO 2 Overhang OK OK OK OK OK OK OK OK OK 3 Overhang OK OK OK OK OK OK NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK OK 3 OK OK OK OK OK OK OK NO NO 2 Overhang OK OK OK OK OK OK OK OK NO 3 Overhang OK OK OK OK OK OK NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK OK 3 OK OK OK OK OK OK OK NO NO 2 Overhang OK OK OK OK OK OK OK OK NO 3 Overhang OK OK OK OK OK NO NO NO NO TABLE C-3B: SYSTEM NO. 7: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (SCREWS AT AND BETWEEN ALL CROWNS) EXPOSURE B FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK OK 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK OK 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK OK 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK OK NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 21 of 22 TABLE C-3C: SYSTEM NO. 7: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (SCREWS AT AND BETWEEN ALL CROWNS) EXPOSURE C FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK OK 3 OK OK OK OK OK OK OK NO NO 2 Overhang OK OK OK OK OK OK OK OK NO 3 Overhang OK OK OK OK OK OK NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK OK 3 OK OK OK OK OK OK OK NO NO 2 Overhang OK OK OK OK OK OK OK OK NO 3 Overhang OK OK OK OK OK NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK OK OK NO NO 2 Overhang OK OK OK OK OK OK OK OK NO 3 Overhang OK OK OK OK NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK OK NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK OK NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK OK NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK OK NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK NO NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK NO NO NO NO NO NO TABLE C-3D: SYSTEM NO. 7: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (SCREWS AT AND BETWEEN ALL CROWNS) EXPOSURE C FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK OK 15 < h < 20 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO 20 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK NO NO NEMO|etc. NEMO ETC, LLC Evaluation Report O39230.10.11-R4 for FL4081-R5 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 4: 08/09/2019 ©2018 NEMO ETC, LLC Ondura® and Onduvilla® Corrugated Asphalt Roofing Systems; (800) 777-7663 Appendix 1, Page 22 of 22 TABLE C-3E: SYSTEM NO. 7: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (SCREWS AT AND BETWEEN ALL CROWNS) EXPOSURE D FOR SLOPE RANGE 7° < SLOPE < 27° (3:12 < PITCH < 6.1:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK OK NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK OK NO NO NO NO NO 15 < h < 20 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK OK NO 3 OK OK OK OK OK OK NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK OK NO NO NO NO NO 20 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK OK NO NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK NO NO NO NO NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK OK NO NO NO NO 2 Overhang OK OK OK OK OK OK OK NO NO 3 Overhang OK OK OK NO NO NO NO NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK OK NO NO NO NO 2 Overhang OK OK OK OK OK OK NO NO NO 3 Overhang OK OK OK NO NO NO NO NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 OK OK OK OK OK OK OK NO NO 3 OK OK OK OK NO NO NO NO NO 2 Overhang OK OK OK OK OK OK NO NO NO 3 Overhang OK OK OK NO NO NO NO NO NO TABLE C-3F: SYSTEM NO. 7: ONDUVILLA® CORRUGATED ASPHALT ROOFING TILE (SCREWS AT AND BETWEEN ALL CROWNS) EXPOSURE D FOR SLOPE RANGE 27° < SLOPE < 45° (6.1:12 < PITCH < 12:12) Mean Roof Height (ft) Roof Pressure Zone Ultimate Wind Speed, Vult (mph) 110 115 120 130 140 150 160 180 200 0 < h < 15 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO 15 < h < 20 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK OK NO 20 < h < 30 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 30 < h < 40 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 40 < h < 50 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK OK 2 & 3 Overhang OK OK OK OK OK OK OK NO NO 50 < h < 60 1 OK OK OK OK OK OK OK OK OK 2 & 3 OK OK OK OK OK OK OK OK NO 2 & 3 Overhang OK OK OK OK OK OK OK NO NO