HomeMy WebLinkAboutProduct Approval r
-
_BCIS Home Log In User Registration Hot Topics j Submit Surcharge j Stats&Facts Publications Contact Us BCIS site Maps Links Search
db
a
�.
I �`Product Approval
USER:Public User
G d !`l
Product Approval Menu>ProQud or Application Search>Applcation List>Application Detail
r FL# FL14317-R10 Z
Application Type Revision � �JEEQ FOH
Code Version 2017 x ,� fi—�d
Application Status Pending FBC L,NIME
Comments ST.a L I COUNTY
Archived 0 BOC 6'
Product Manufacturer Boral Roofing/MonierLifetile �v //
Address/Phone/Email 7575 Irvine Center Drive ( 2, !
Suite 100
Irvine,CA 92618
(602) 88 Ext 8320 File Copy
thomas.jememmett@boral.com
Authorized Signature Thomas Jemmett
thomas.jemmett@boral.com
Technical Representative Adrian Cooper
Address/Phone/Email 135 NW 20th Street
Boca Raton,FL 33431
(954)520-5461
acoopeer@minierlifetile.com
Quality Assurance Representative
Address/Phone/Email
I
Category Roofing
Subcategory Underlayments
i
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
L; Evaluation Report-Hardcopy Received
I
Florida Engineer or Architect Name who developed the Robert J.M.Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/21/2020
Validated By John W. Knezevich,PE
dj Validation Checklist-Hardcopy Received
FL14317 R10 COI 01$ 1 COI IEMIN N.pddf
Certificate of Independence 2 0 N E
P
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
FRSA/TRI(April 2012)04-12 2012
UL 1897 2012
Equivalence of Product Standards
i
Certified By
i
Sections from the Code
is
Product Approval Method Method 1 Option D
Date Submitted 10/12/2018
Date Validated 10/15/2018
Date Pending FBC Approval 10/22/2018
Summary of Products
FL# Model,Number or Name Description
14317.1 Boral Roof Underlayments Roof underlayments for use in prepared roof assemblies
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14317 R10 II 2018 10 FINAL ER BORAL Underlayments FL14317-
Approved for use outside HVHZ:Yes R1O.pdf
Impact Resistant:N/A Verified By: Robert J.M.Nieminen PE-59166
Design Pressure:+N/A/-210 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this application Evaluation Reports
pertains to a particular underlayment system for use FL14317 R10 AE 2018 10 FINAL ER BORAL Underlayments FL14317-
under foam-on tile systems. Refer to ER Section RiO.pdf
5.6.4.2.)Refer to ER Section 5 for Limits of Use. Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee Fl,32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.C-y_rjght 2007-2013 State of Florida.::Priv Statement::Accessibllity Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
--r--- - ` ' �
-'
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Concrete
Deck Tyne: Wood
1. SCOPE
This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as
manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations
where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure
values obtained by calculations in compliance with RAS 127 using the values listed in the installation section
herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Saxony 900-Slate Length= 17" TAS 112 Flat profile,interlocking,high-pressure extruded
Width= 13" concrete roof tile with two nail holes. For direct deck,
thickness= 1-5/32" batten,mortar set or adhesive set applications.
Saxony 900 Length= 17" TAS 112 Flat profile,interlocking,high-pressure extruded
Split Shake Width= 13" concrete roof tile with two nail holes. For direct deck,
thickness= 1-9/32" batten,mortar set or adhesive set applications. Top
surface produced with 4 different configurations:
1. Complete tile brushed
2. Right half brushed(shown in drawing)
3. Left half brushed
4. No brush
Saxon 900-Shake Length== 17" TAS 112 Flat profile,interlocking,high-pressure extruded
Y �
Width= 13" concrete roof tile with two nail holes. For direct deck,
thickness= 1-9/32" batten,mortar set or adhesive set applications.
Trim Pieces Length:varies TAS-112 Accessory trim,boosted Barcelona,concrete roof
Width:varies pieces for use at hips,ridges and rakes.
varying thickness
NOA No.: 18-0509.17
MIAM•DADECOUNTY Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 2 of 9
2.1 MANUFACTURING LOCATION
2.1.1 Lake Wales,FL
2.2 EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Renort Date
The Center for Applied 94-084 Static Uplift Testing May 1994
Engineering,Inc. TAS 101 (Mortar Set)
The Center for Applied 94-060A Static Uplift Testing March, 1994
Engineering,Inc. TAS 101 (Adhesive Set)
The Center for Applied 25-7183-6 Static Uplift Testing TAS 102 Feb. 1995
Engineering,Inc. (2 Quik-Drive Screws,Direct Deck)
The Center for Applied 25-7183-5 Static Uplift Testing TAS 102 Feb. 1995
Engineering,Inc. (2 Quik-Drive Screws,Battens)
The Center for Applied 25-7214-1 Static Uplift Testing TAS 102 March, 1995
Engineering,Inc. (1 Quik-Drive Screw,Direct Deck)
The Center for Applied 25-7214-5 Static Uplift Testing TAS 102 March, 1995
Engineering,Inc. (1 Quik-Drive Screw,Battens)
The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994
Engineering,Inc. Test#MDC-77 TAS 100
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix II&III TAS 108(Nail-On)
Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994
TAS 108 (Nail-On)
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
TAS 108(Mortar Set)
Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993
screw vs. smooth shank nails
Atlanta Testing& R1.894/R2.894/R3.894 Physical Properties Aug. 1994
Engineering, Inc. TAS 112
Celotex Corporation 520109-1 Static Uplift Testing Dec. 1998
Testing Service 520111-4 TAS 101
Celotex Corporation 520191-1 Static Uplift Testing March 1999
Testing Service TAS 101
Walker Engineering,Inc. Evaluation Calculations 25-7094 February 1996
Walker Engineering,Inc. Evaluation Calculations 25-7496 April 1996
Walker Engineering,Inc. Evaluation Calculations 25-7584/25-7804b-8/25-7804-4&5 December 1996
25-7848-6
Walker Engineering,Inc. Evaluation Calculations 25-7183 March 1995
Walker Engineering,Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16
Walker Engineering,Inc. Calculations Two Patty Adhesive Set System April 1999
Walker Engineering,Inc. Evaluation Calculations Restoring Moments Due to Gravity 09/01/16
American Test Lab of RT0617.04-16 TAS 112 06/29/16
South Florida
C
•DADE COUNTY
NOA No.: 18-0509.17
• Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 3 of 9
PRI Construction Material COPO-002-02-12 TAS 101 10/12/2016
COPO-002-02-06 TAS 101 10/12/2016
COPO-002-02-05 TAS 101 10/12/2016
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
the applicable Building Code.
4. INSTALLATION
4.1 Saxony 900 (Slate, Shake& Split Shake) Concrete Roof Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118,RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight(W) and Dimensions (I x w)
Tile Profile Weight-W(Ibf) Length-1 (ft) Width-w(ft)
Saxony 900 10.9 1.417 1.08
Slate, Shake &Split Shake
Table 2: Aerodynamic Multipliers -X(ft3)
Tile % (ft3) X(ft3)
Profile Batten Application Direct Deck Application
Saxony 900 0.291 0.315
Slate, Shake &Split Shake
Table 3: Restoring Moments due to Gravity- M9 (ft-Ibf)
Tile 2":12" 3":12" 4"•12" 5":12" 6":12" 7":12" or
Profile greater
Saxony 900 Direct Deck Direct Deck Battens Direct Battens Direct Battens Direct Battens Direct
Slate, Shake & Deck Deck Deck Deck
Split Shake 7.70 7.62 6.61 7.50 6.48 7.34 6.31 7.16 6.13 6.95
MIAMI•DADE COUNTY NOA No.: 18-0509.17
� Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 4 of 9
Table 4: Attachment Resistance Expressed as a Moment- Mr(ft-Ibf)
for Mechanically Fastened Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" (min. 19/32"
plywood) plywood)
Saxony 900 2-10d Ring Shank Nails 30.9 38.1 17.2
Slate,Shake&Split 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9
Shake 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4
1 18 Screw 30.8 30.8 18.2
2 .#8 Screws 51.7 51.7 24.4
1-10d Smooth or Screw Shank Nail (Field 24.3 24.3 24.2
Clip)
1-10d Smooth or Screw Shank Nail(Eave 19.0 19.0 22.1
Clip)
2-10d Smooth or Screw Shank Nails (Field 35.5 35.5 34.8
Clip)
2-10d Smooth or Screw Shank Nails (Eave 31.9 31.9 32.2
Clip)
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-Ibf)
for Two Paddy Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Saxony 900 Slate, Shake &Split Shake Adhesive' 31.3 2&3
594
1 See foam adhesive manufacturer's component approval for installation requirements.
2 The Dow Chemical Company TileBond'one-component foam minimum weight per paddy 13.9 grams.
3. ICP Adhesives Polyset®AH-160 two-component foam,minimum weight per paddy 8 grams.
4. DAP Products Touch N'Seal Storm Bond 2 two-component foam minimum weight per paddy 8 grams.
Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-Ibf)
for Single Paddy Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Saxony 900 Slate, Shake &Split Shake ICP Adhesives Polyset®AH-160 118.9 3
Two-component foam 40.4 4
DAP Products Touch N' Seal Storm 935
Bond 2 two-component foam 45 6
3 Large paddy placement of 45 grams of Polyset®AH-160.
4 Medium paddy placement of 24 grams of Polyset®AH-160.
5
Large paddy DAP Products Touch N'Seal Storm Bond 2 two-component foam minimum weight per paddy 45 grams.
6 Medium paddy DAP Products Touch N'Seal Storm Bond 2 two-component foam minimum weight per paddy 24 grams.
C
•DADE
COUNTY
NOA No.: 18-0509.17
• Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 5 of 9
Table 7: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Mortar Set Systems
Tile Tile Minimum Attachment
Profile Application Resistance
Saxony 900 Slate, Shake &Split Shake Mortar Sets 43.96
7 Tile-Tite Roof Tile Mortar
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed
below,or following statement: "Miami-Dade County Product Control Approved".
LABEL FOR BORAL SAXONY 900 TILES(LAKE WALES FL PLANT
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
PROFILE DRAWINGS
NOA No.: 18-0509.17
MIAMI DARE COUNTY Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 6 of 9
NAIL HOLES "
1-5/32"(Slate)
k'
17" COVERLOCK
I
13 „
UNDERLOCK
SAXONY 900-SLATE
NOA No.: 18-0509.17
MIAMIFDADECOUNTY Expiration Date: 04126122
Approval Date: 08102118
Page 7 of 9
PROFILE DRAWINGS
NAIL HOLES
1-9/32"(Shake)
17.,, ti . _... 13
Note: Available Top Surface Finishes
6. Complete tile brushed
6. Right half brushed (shown in drawing)
7. Left half brushed
8. No brush
SAXONY 900-SPLIT SHAKE
NOA No.: 18-0509.17
MIAMI•DADE couNT r Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 8 of 9
PROFILE DRAWINGS
NAIL HOLES
1-9/32"(Shake)
17 "
J
1311
SAXONY 900-SHAKE
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
NOA No.: 18-0509.17
• Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 9 of 9